Search by property
Jump to navigation
Jump to search
This page provides a simple browsing interface for finding entities described by a property and a named value. Other available search interfaces include the page property search, and the ask query builder.
List of results
- ML20062G971 + (04:12:46, 17 December 2024)
- ML20062G969 + (04:12:47, 17 December 2024)
- ML20062G968 + (04:12:47, 17 December 2024)
- ML20062G967 + (04:12:49, 17 December 2024)
- ML20062G963 + (04:12:50, 17 December 2024)
- 05000254/LER-1982-019-03, /03L-0:on 820713,during Calibr of Reactor Automatic Relief Valves,Controllers for Valves 1-203-3B, 3D & 3E Found to Trip at Pressures in Excess of Tech Spec Limits.Caused by Setpoint Calibr Below Limits + (04:12:52, 17 December 2024)
- ML20062G960 + (04:12:53, 17 December 2024)
- ML20062G958 + (04:12:54, 17 December 2024)
- ML20062G957 + (04:12:54, 17 December 2024)
- 05000334/LER-1982-026-03, /03L-0:on 820725,during Investigation of Spurious Alarms from Subcooling Margin Monitor,Monitor Indicated All Eight Incore Thermocouples Spiking.Cause Unknown.Cable Connectors Cleaned + (04:12:55, 17 December 2024)
- 05000334/LER-1982-026, Forwards LER 82-026/03L-0 + (04:13:01, 17 December 2024)
- ML20062G950 + (04:13:01, 17 December 2024)
- ML20062G945 + (04:13:02, 17 December 2024)
- ML20062G944 + (04:13:03, 17 December 2024)
- 05000254/LER-1982-019, Forwards LER 82-019/03L-0 + (04:13:04, 17 December 2024)
- 05000318/LER-1979-008-03, /03L-0 on 790208:22B Safety Injection Tank Level & Pressure Were Below Tech Spec Min Due to Fill Valve Not Shutting Tightly After Being Opened for Drainage.Tank Refilled & Valve Successfully Cycled Several Times + (04:13:05, 17 December 2024)
- 05000331/LER-1982-047-01, /01T-0:on 820729,during Testing,Pressure Differential Switches Which Control Reactor Bldg to Suppression Chamber Vacuum Breakers CV-4304 & CV-4305 Tripped Out of Spec.Caused by Instrument Drift + (04:13:10, 17 December 2024)
- 05000318/LER-1979-008, Forwards LER 79-008/03L-0 + (04:13:11, 17 December 2024)
- ML20062G936 + (04:13:12, 17 December 2024)
- ML20062G935 + (04:13:12, 17 December 2024)
- IR 05000440/2019006 + (04:13:20, 17 December 2024)
- ML20062G928 + (04:13:21, 17 December 2024)
- 05000305/LER-1982-009, Forwards Updated LER 82-009/03X-1 + (04:13:22, 17 December 2024)
- ML20062G927 + (04:13:22, 17 December 2024)
- ML20062G925 + (04:13:23, 17 December 2024)
- ML20062G924 + (04:13:23, 17 December 2024)
- 05000331/LER-1982-047, Forwards LER 82-047/01T-0 + (04:13:24, 17 December 2024)
- ML20062G923 + (04:13:24, 17 December 2024)
- ML20062G917 + (04:13:25, 17 December 2024)
- 05000304/LER-1982-017-03, /03L-0:on 820708,during Hot Shutdown & After Taking MSIV 2B Out of Sequence,Msiv Drifted Open & Was Rendered Inoperable.Caused by Failure to Open Drain Valve. Signs Reminding Operators to Verify Drain Position Posted + (04:13:27, 17 December 2024)
- 05000254/LER-1979-005-03, /03L-0 on 790123:during Unit 1/2 Diesel Generator Monthly Load Test Qos 6600-1,pilot Solenoid Valve to Air Starting Motors Failed & Unit 1/2 Diesel Was Shutdown. Caused by Mechanical Failure of Valve.Valve Was Replaced + (04:13:29, 17 December 2024)
- IR 05000295/1990023 + (04:13:30, 17 December 2024)
- 05000265/LER-1982-012-03, /03L-0:on 820714,controllers for Valves 2-203-3A, 3B,3C & 3E Found to Trip at Pressures in Excess of Specified Tech Spec Limits.Caused by Improper Calibr of Pressure Switches + (04:13:32, 17 December 2024)
- ML20062G911 + (04:13:33, 17 December 2024)
- ML20062G907 + (04:13:34, 17 December 2024)
- ML20062G905 + (04:13:35, 17 December 2024)
- 05000304/LER-1982-017, Forwards LER 82-017/03L-0 + (04:13:36, 17 December 2024)
- IR 05000331/1990021 + (04:13:37, 17 December 2024)
- ML20062G903 + (04:13:37, 17 December 2024)
- ML20062G901 + (04:13:38, 17 December 2024)
- 05000265/LER-1982-012, Forwards LER 82-012/03L-0 + (04:13:39, 17 December 2024)
- ML20062G900 + (04:13:39, 17 December 2024)
- ML20062G896 + (04:13:40, 17 December 2024)
- ML20062G894 + (04:13:41, 17 December 2024)
- ML20062G893 + (04:13:41, 17 December 2024)
- ML20062G892 + (04:13:42, 17 December 2024)
- ML20062G891 + (04:13:43, 17 December 2024)
- ML20062G888 + (04:13:46, 17 December 2024)
- ML20062G887 + (04:13:48, 17 December 2024)
- ML20062G886 + (04:13:48, 17 December 2024)
- 05000254/LER-1982-013-03, /03L-0:on 820621,while Diesel Generator Cooling Water Pump Was Being Run in Conjunction W/Hpci Monthly Operability Surveillance,Qoc 2300-2 Pump Observed to Have No Flow by Local Indications.Caused by Pump Being Air Bound + (04:13:50, 17 December 2024)
- IR 05000255/2019006 + (04:13:51, 17 December 2024)