ML20062G923

From kanterella
Jump to navigation Jump to search
Forwards Response to IE Bulletin 82-02, Degradation of Threaded Fasteners in RCPB of PWR Plants. Approx 70 Manhours Expended in Bulletin Preparation
ML20062G923
Person / Time
Site: Indian Point 
Issue date: 08/03/1982
From: Brons J
POWER AUTHORITY OF THE STATE OF NEW YORK (NEW YORK
To: Haynes R
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION I)
References
REF-SSINS-6820 IEB-82-02, IEB-82-2, IP-JAS-2711, NUDOCS 8208130234
Download: ML20062G923 (2)


Text

}

r

~

POWER AUTHORITY OF THE STATE OF NEW YORK INDIAN POINT NO. 3 NUCLEAR POWER PLANT P. O. BOX 215 BUCHANAN, N. Y. t 0511 TELEPHONE 2 914 739 8200 S

August 3, 1982 IP-JAS-2711 Ronald C. Haynes, Regional Administrator Office of Inspection and Enforcement Region I U. S. Nuclear Regulatory Commission 631 Park Avenue King of Prussia, Pennsylvania 19406

Subject:

I. E.Bulletin 82-02 Degradation of Threaded Fasteners In The Reactor Coolant Pressure Boundary of PWR Plants

Dear Mr. Haynes:

to this letter provides the information requested by Action Items 3 and 5 of the subject bulletin concerning closures and connections identified within the subject scope of your letter.

Approximately 70 man hours were expended in investigation and preparation of this report.

l Action Items 1, 2, and 4 will be completed, as required, af ter the com-l

.pletion of the current refueling outage.

l l

Very truly yours, l

n John C. Brons l

JAS:ms Resident Manager Enclosure SUBSCRIBED AND SWORN TO BEFORE ME THIS A/ O DAY j

OF Os M 9 9,,P 2

~

h N

b&

NICHOLAS A. CARLUCCf Notary Public. State of New York No. 4651851, Putnam County

't h l Commission Expires March 30, 1983 8208130234 820803 1

i PDR ADOCK 05000286 G

PDR

r-I ATTACINENT 1 ACTION ITEM 3a:

Identify those bolted: closures of the RCPB that have experienced leakage, particularly those locations.where leakage occurred during the most recent plant operating cycle.

Describe the inspections made and corrective measures taken to eliminate the problem.

If the leakage was attributed to gasket failure or its design, so indicate.

t

RESPONSE

During routine ISI inspection, 10" accumulator check valves 897-A (Accumulator #31) and 895-B (Accumulator #32) were found to have possible in-dications of leakage.

The Indian Point 3 plant is presently in a refueling outage and the extent of repair has not. yet been ascertained.

If required.

planned corrective action would require removal of the bonnet; visual in-spection of the seal, seal area, and closure studs; and repair or replacement as necessary In addition, as part of plant Preventive Maintenance, the steam generator primary manway closure studs are being replaced.

Although minor leakage has occurred at the primary manways it has not been attributable to closure stud degradation.

No other bolted closures of the RCP3 within the scope of I. E.Bulletin 82-02 have been discovered to have experienced leakage.

ACTION ITEM 3b:

Identify those closures and connections, if any, where fastener lubricants and injection sealant materials have been or are being used and report on plant experience with their application, particularly any instances of SCC of fasteners.

Include types and composition of materials used.

RESPONSE

For lubrication of RCPB closure studs, two products have been and are currently in use at IP3:

1.

Fel-Pro Nuclear Grade N-1000, a high purity coppergraphite anti-seizure lubricant.

2.

Fel-Pro Nuclear Grade N-5000, a high purity nickelgraphite anti-seizure lubricant.

These lubricants do not contain molybdenum disulfide (MoS ) and contain 2

less than 25 ppm sulfur.

IP3 has extensively employed the 'use of ithese lubricants and has experienced no noticeable degrading effects from any of its applications.

Injection sealant materials have not been used on any RCPB closures of the _ type identified in the scope of I.E. Bulletin No. 82-02.

_ _ _ _ _