Search by property
Jump to navigation
Jump to search
This page provides a simple browsing interface for finding entities described by a property and a named value. Other available search interfaces include the page property search, and the ask query builder.
List of results
- ML20062K035 + (03:40:57, 17 December 2024)
- IR 05000259/1982015 + (03:40:59, 17 December 2024)
- ML20062K031 + (03:40:59, 17 December 2024)
- ML20062K029 + (03:41:01, 17 December 2024)
- ML20062K026 + (03:41:01, 17 December 2024)
- ML20062K025 + (03:41:02, 17 December 2024)
- IR 05000261/1982025 + (03:41:18, 17 December 2024)
- ML20062K024 + (03:41:18, 17 December 2024)
- ML20062K022 + (03:41:20, 17 December 2024)
- ML20062K020 + (03:41:20, 17 December 2024)
- IR 05000275/1982024 + (03:41:21, 17 December 2024)
- ML20062K018 + (03:41:22, 17 December 2024)
- ML20062K016 + (03:41:23, 17 December 2024)
- ML20062K017 + (03:41:23, 17 December 2024)
- ML20062K014 + (03:41:24, 17 December 2024)
- ML20062K008 + (03:41:28, 17 December 2024)
- ML20062K007 + (03:41:29, 17 December 2024)
- ML20062K004 + (03:41:30, 17 December 2024)
- ML20062K005 + (03:41:30, 17 December 2024)
- IR 05000259/1982019 + (03:41:31, 17 December 2024)
- BVY-93-137, Forwards Vermont Yankee Nuclear Power Corp Third Interval ISI Program 930901-030831, Rev 0 + (03:41:32, 17 December 2024)
- ML20062K000 + (03:41:32, 17 December 2024)
- ML20062J998 + (03:41:33, 17 December 2024)
- 05000335/LER-1982-032-03, /03L-0:on 820708,MV-09-12 Discharge Valve for Steam Driven 1C Auxiliary Feedwater Pump to B Steam Generator Would Not Cycle Properly.Caused by Torque Limiter Switch Malfunction.New Motor Installed + (03:41:34, 17 December 2024)
- ML20062J996 + (03:41:35, 17 December 2024)
- 05000301/LER-1982-005-01, /01T-0:on 820727,discovered Two of Three Level Instruments on Boric Acid Storage Tank C Powered from Common Source.Cause Unknown Due to Lack of Maint Documentation.Wiring Will Be Charged to Correct Problem + (03:41:37, 17 December 2024)
- ML20062J992 + (03:41:38, 17 December 2024)
- ML20062J991 + (03:41:39, 17 December 2024)
- ML20062J987 + (03:41:41, 17 December 2024)
- 05000416/LER-1982-016-03, /03L-0:on 820702,during Review of Completed Surveillance,One Channel Found Out of Spec.Caused by Delayed Notification to Shift Supervisor of Failure Until 820707 When Test Results Identified as Unacceptable + (03:41:43, 17 December 2024)
- ML20062J984 + (03:41:44, 17 December 2024)
- ML20062J983 + (03:41:45, 17 December 2024)
- ML20062J982 + (03:41:46, 17 December 2024)
- ML20062J981 + (03:41:46, 17 December 2024)
- ML20062J980 + (03:41:47, 17 December 2024)
- ML20062J978 + (03:41:48, 17 December 2024)
- ML20062J979 + (03:41:48, 17 December 2024)
- ML20062J977 + (03:41:49, 17 December 2024)
- ML20062J976 + (03:41:50, 17 December 2024)
- ML20062J974 + (03:41:51, 17 December 2024)
- ML20062J975 + (03:41:51, 17 December 2024)
- ML20062J973 + (03:41:53, 17 December 2024)
- IR 05000302/1982013 + (03:41:59, 17 December 2024)
- 05000335/LER-1982-032, Forwards LER 82-032/03L-0 + (03:42:01, 17 December 2024)
- ML20062J969 + (03:42:01, 17 December 2024)
- ML20062J967 + (03:42:02, 17 December 2024)
- ML20062J964 + (03:42:03, 17 December 2024)
- ML20062J963 + (03:42:04, 17 December 2024)
- ML20062J960 + (03:42:05, 17 December 2024)
- ML20062J956 + (03:42:06, 17 December 2024)
- ML20062J954 + (03:42:07, 17 December 2024)