Search by property
Jump to navigation
Jump to search
This page provides a simple browsing interface for finding entities described by a property and a named value. Other available search interfaces include the page property search, and the ask query builder.
List of results
- ML20071H687 + (11:29:59, 15 December 2024)
- 05000280/LER-1982-007, Forwards LER 82-007/03L-0 + (11:30:00, 15 December 2024)
- ML20071H685 + (11:30:00, 15 December 2024)
- HL-4620, Application for Amends to Licenses DPR-57 & NPF-5,revising TS to Improved Insertion Instructions,Consistent w/NUREG- 1433 + (11:30:01, 15 December 2024)
- ML20071H678 + (11:30:02, 15 December 2024)
- ML20071H679 + (11:30:02, 15 December 2024)
- ML20071H677 + (11:30:03, 15 December 2024)
- ML20071H674 + (11:30:03, 15 December 2024)
- ML20071H673 + (11:30:04, 15 December 2024)
- ML20071H671 + (11:30:04, 15 December 2024)
- 05000370/LER-1983-005-03, /03L-0:on 830413,procedure Review Revealed That Area Temp Monitoring Surveillance Not Performed within 12 H Limit.Caused by Revs to Tech Specs.Surveillance Interval Not Recorded.Procedures Revised + (11:30:06, 15 December 2024)
- NRC-94-4192, Informs That Review of NRC RAIs on AP600 Received in Ltr for Proprietary Matl,Indicates That RAIs Contains No Info That Westinghouse Considers Proprietary + (11:30:07, 15 December 2024)
- 05000280/LER-1982-010-03, /03L-0:on 820105,while Removing Unit from Svc, Spurious Safety Injection Signal Generated & Trip Valve Failed to Close.Cause Not Found.Investigation Continuing + (11:30:08, 15 December 2024)
- ML20071H661 + (11:30:09, 15 December 2024)
- ML20071H659 + (11:30:10, 15 December 2024)
- 05000302/LER-1982-007-03, /03L-0:on 820123,starting Air Pressure for Emergency Diesel Generator B Too Low for Automatic Start & Air Pressure Low Alarm Did Not Actuate.Caused by EGV-16,air Tank Blowdown Valve Not Fully Closed & Alarm Malfunction + (11:30:11, 15 December 2024)
- ML20071H656 + (11:30:12, 15 December 2024)
- AECM-83-0287, RO 83-031/0:on 830415,fire Doors Blocked Open for 21 Days, Exceeding 7-day Time Limit.Doors Closed & Restored to Operation + (11:30:13, 15 December 2024)
- ML20071H655 + (11:30:13, 15 December 2024)
- 05000328/LER-1983-059-03, /03L-0:on 830422,while in Mode 1,rod Position Indication for Rod C-5 in Shutdown Bank D Misaligned by 12 Steps & Declared Inoperable.Cause Unknown.Rod Position Indicator & Cable Verified + (11:30:17, 15 December 2024)
- ML20071H647 + (11:30:18, 15 December 2024)
- ST-HL-AE-4833, Responds to NRC Re Violations Noted in Insp Rept 50-498/94-18 & 50-499/94-18.Corrective Action:Increased Number of Personnel Per Shift + (11:30:19, 15 December 2024)
- ML20071H642 + (11:30:20, 15 December 2024)
- ML20071H641 + (11:30:21, 15 December 2024)
- ML20071H637 + (11:30:22, 15 December 2024)
- ML20071H639 + (11:30:22, 15 December 2024)
- 05000302/LER-1982-007, Forwards LER 82-007/03L-0 + (11:30:23, 15 December 2024)
- ML20071H636 + (11:30:23, 15 December 2024)
- ML20071H631 + (11:30:24, 15 December 2024)
- ML20071H628 + (11:30:25, 15 December 2024)
- ML20071H626 + (11:30:25, 15 December 2024)
- ML20071H625 + (11:30:26, 15 December 2024)
- ML20071H621 + (11:30:31, 15 December 2024)
- 05000302/LER-1982-006-03, /03L-0:on 820125,during Weekly Battery Check, SP-520,on Station Battery 3B,pilot Cell 115 Failed to Meet Acceptance Criteria.Caused by Dissipation of Charge Between Surveillances.Battery Recharged & Returned to Svc + (11:30:33, 15 December 2024)
- ML20071H618 + (11:30:34, 15 December 2024)
- ML20071H614 + (11:30:34, 15 December 2024)
- 05000302/LER-1982-006, Forwards LER 82-006/03L-0 + (11:30:35, 15 December 2024)
- 05000338/LER-1983-025-03, /03L-0:on 830429,while Conducting Surveillance Test,Conditioning Module TC-MM-100A to Meteorological 33-ft Temp Chart Recorder Drifted 1.6 F.Caused by Instrument Drift.Module Recalbr + (11:30:37, 15 December 2024)
- L-83-311, Clarifies 830418 Final Deficiency Rept Re Diesel Generator Start Relay Defect.Addl Indication Provided to Indicate to Control Room When Master Control Switch,Located in Diesel Generator Bldg,Is in Stop Position + (11:30:38, 15 December 2024)
- ML20071H610 + (11:30:38, 15 December 2024)
- 05000280/LER-1982-008-03, /03L-0:on 820121,instrument Malfunction Resulted in Loss of All Pressurized Heaters.Caused by Short in One Pressurized Level Comparator.Short Repaired & Pressurizer Control Sys Returned to Normal Condition + (11:30:40, 15 December 2024)
- ML20071H605 + (11:30:41, 15 December 2024)
- ML20071H604 + (11:30:42, 15 December 2024)
- 05000352/LER-1994-009, :on 940617,HVAC Exhaust Plenum High Radiation Monitor Inadvertently Tripped.Caused by Malfunction of Alarm Circuit Card within Monitor.Failed Alarm Circuit Will Be Returned to Manufacturer for Further Analysis + (11:30:44, 15 December 2024)
- 05000260/LER-1982-050, Forwards Updated LER 82-050/03X-1 + (11:30:45, 15 December 2024)
- ML20071H599 + (11:30:45, 15 December 2024)
- ML20071H598 + (11:30:46, 15 December 2024)
- ML20071H597 + (11:30:47, 15 December 2024)
- ML20071H596 + (11:30:48, 15 December 2024)
- 05000280/LER-1982-003-03, /03L-0:on 820122,loss of Boric Acid Flow to Blender Observed.Caused by Inadequate Insulation on FT-1113 & Adjacent Piping.Blockages Removed or Freed & Addl Insulation Added to Prevent Recurrence + (11:30:49, 15 December 2024)
- AECM-83-0280, Final RO 83-002/1:on 830201,smoke Detectors on Elevation 119 Ft of Auxiliary Bldg Covered to Perform Planned Maint. Hourly Fire Watch Established.Detectors Restored to Svc on 830509 + (11:30:50, 15 December 2024)
- NRC-94-0045, Responds to NRC Re Violations Noted in Insp Rept 50-341/94-07.Corrective Action:Individuals Involved Were Disciplined + (11:30:51, 15 December 2024)