- B10650, Interim Deficiency Rept Re Pipe Strap Design Specified for Installation W/O Qualification.Initially Reported on 821122. Evaluation to Determine Pipe Straps for Which Design Loads Exceed Allowable Limits Continuing + (10:51:02, 15 December 2024)
- TXX-3683, Forwards Audit Rept Re Environ Qualification Verification of Installed Equipment Per Request.No Model Identification Indicated on Recombiner,However,Ratings Info on Nameplate Sufficient to Establish Model Identify + (10:51:02, 15 December 2024)
- 1CAN018305, Requests Extension Until 830318 to Request Hearing on NRC 821210 Order Requiring Installation of Inadequate Core Cooling Instrumentation Sys.Technical Evaluation Underway to Ensure Requirements Can Be Fulfilled + (10:51:03, 15 December 2024)
- ML20072A955 + (10:51:03, 15 December 2024)
- TXX-3659, Forwards Final Response to NUREG-0612, Control of Heavy Loads at Nuclear Power Plants + (10:51:05, 15 December 2024)
- 05000296/LER-1983-030-03, /03L-0:on 830504,hydrogen Analyzer B Removed from Svc to Replace Defective Hydrogen Sample Inlet Pump Motor. Caused by Worn End Bell.Pump & Motor Assembly Replaced & SI 4.7.H Successfully Completed + (10:51:06, 15 December 2024)
- BECO-LTR-94-085, Forwards fitness-for- Duty Program Performance Data for Period Jan-June 1994 + (10:51:07, 15 December 2024)
- ML20072A936 + (10:51:08, 15 December 2024)
- ML20072A934 + (10:51:08, 15 December 2024)
- ML20072A933 + (10:51:12, 15 December 2024)
- ML20072A929 + (10:51:13, 15 December 2024)
- ML20072A923 + (10:51:13, 15 December 2024)
- ML20072A921 + (10:51:14, 15 December 2024)
- 05000255/LER-1982-049-03, /03L-0:on 821220,during Routine Shift Surveillance,Fire Sys Alarm Panel C-47 Found Inoperable Due to Loss of Power.Caused by Damaged Wires in Remote Flow Switch Resulting in Short Circuit.Wires & Contacts Repaired + (10:51:15, 15 December 2024)
- ML20072A916 + (10:51:16, 15 December 2024)
- 05000255/LER-1982-049, Forwards LER 82-049/03L-0 + (10:51:17, 15 December 2024)
- ML20072A915 + (10:51:17, 15 December 2024)
- ML20072A905 + (10:51:18, 15 December 2024)
- ML20072A898 + (10:51:19, 15 December 2024)
- ML20072A896 + (10:51:19, 15 December 2024)
- 0CAN048326, Advises That Addl Time Required to Review Annual Environ Operating Rept.Rept Will Be Submitted by 830531 + (10:51:20, 15 December 2024)
- ML20072A885 + (10:51:20, 15 December 2024)
- ML20072A878 + (10:51:21, 15 December 2024)
- ML20072A883 + (10:51:21, 15 December 2024)
- ML20072A876 + (10:51:22, 15 December 2024)
- ML20072A871 + (10:51:22, 15 December 2024)
- ML20072A867 + (10:51:23, 15 December 2024)
- ML20072A870 + (10:51:23, 15 December 2024)
- ML20072A862 + (10:51:24, 15 December 2024)
- ML20072A860 + (10:51:25, 15 December 2024)
- 05000348/LER-1983-021-03, /03L-0:on 830506,power Supply Breaker HBL7R Opened.Possibly Caused by Personnel Inadvertently Tripping Breaker by Closing Locker.Locker Moved + (10:51:27, 15 December 2024)
- ML20072A850 + (10:51:28, 15 December 2024)
- ML20072A847 + (10:51:29, 15 December 2024)
- ML20072A845 + (10:51:29, 15 December 2024)
- ML20072A844 + (10:51:30, 15 December 2024)
- ML20072A840 + (10:51:31, 15 December 2024)
- ML20072A835 + (10:51:33, 15 December 2024)
- ML20072A838 + (10:51:33, 15 December 2024)
- ML20072A832 + (10:51:34, 15 December 2024)
- ML20072A833 + (10:51:34, 15 December 2024)
- ML20072A825 + (10:51:35, 15 December 2024)
- ML20072A831 + (10:51:35, 15 December 2024)
- ML20072A823 + (10:51:36, 15 December 2024)
- ML20072A818 + (10:51:37, 15 December 2024)
- ML20072A821 + (10:51:37, 15 December 2024)
- ML20072A817 + (10:51:38, 15 December 2024)
- 05000395/LER-1983-040-03, /03L-0:on 830506,control Room Emergency Ventilation Sys Trains a & B Inoperable for 26 H.Caused by Failure in Implementing Procedural Controls.Personnel Counseled + (10:51:39, 15 December 2024)
- ML20072A811 + (10:51:40, 15 December 2024)
- ML20072A798 + (10:51:41, 15 December 2024)
- ML20072A803 + (10:51:41, 15 December 2024)
- TXX-3612, Forwards Comanche Peak Steam Electric Station Person-Motion Study of Post-Accident Sampling Activities to Demonstrate Compliance W/GDC-19 & NUREG-0737,Item II.B.3, Per SER Suppl 2 (NUREG-0797) + (10:51:42, 15 December 2024)
- AECM-83-0322, Final Deficiency Rept PRD-82/27 Re Potential for Plant Flooding Based on PMP Flood Level.Watertight Door Seals,Toe Plate & Curb to Be Installed & Two Penetrations Raised.Also Reportable Under Part 21 + (10:51:43, 15 December 2024)