- ML20074A641 + (08:11:05, 15 December 2024)
- 05000255/LER-1983-025-03, /03L-0:on 830410,sample from T-82c Showed Boron Concentration Below Tech Spec Limit of 1720 Ppm.Caused by Minor Leakage Past Loop Check Valve & SIT Check Valve. Primary Coolant Leak Rate Being Closely Monitored + (08:11:07, 15 December 2024)
- 05000280/LER-1983-020, Forwards LER 83-020/03L-0 + (08:11:08, 15 December 2024)
- ML20074A634 + (08:11:08, 15 December 2024)
- 05000255/LER-1983-025, Forwards LER 83-025/03L-0 + (08:11:09, 15 December 2024)
- ML20074A631 + (08:11:09, 15 December 2024)
- ML20074A625 + (08:11:10, 15 December 2024)
- 05000254/LER-1983-019-03, /03L-0:on 830412,1A Loop Core Spray Discharge Piping Pressure Indicated Above Tech Specs.Caused by Operator Failure to Properly Bleed Down Core Spray Discharge Piping & Failure of High Pressure Alarm to Annunciate + (08:11:11, 15 December 2024)
- ML20074A619 + (08:11:12, 15 December 2024)
- 05000255/LER-1983-027-01, /01T-0:on 830428,w/safety Injection Tank D T-820 Inoperable,Tank T-82B Became Inoperable Due to Low Level. Caused by Leakage Past Fill & Drain Valve on Tank B.Fill & Drain Valves to Be Inspected & Repaired + (08:11:14, 15 December 2024)
- 05000254/LER-1983-019, Forwards LER 83-019/03L-0 + (08:11:15, 15 December 2024)
- ML20074A610 + (08:11:15, 15 December 2024)
- 05000255/LER-1983-027, Forwards LER 83-027/01T-0 + (08:11:16, 15 December 2024)
- ML20074A607 + (08:11:17, 15 December 2024)
- ML20074A606 + (08:11:17, 15 December 2024)
- ML20074A604 + (08:11:19, 15 December 2024)
- ML20074A602 + (08:11:22, 15 December 2024)
- 05000280/LER-1983-068, Forwards Updated LER 83-068/03X-1 + (08:11:27, 15 December 2024)
- ML20074A594 + (08:11:28, 15 December 2024)
- ML20074A587 + (08:11:31, 15 December 2024)
- 05000315/LER-1983-033-03, /03L-0:on 830409,during Normal Operation,Following Daily Routine Particulate Filter Change on Lower Containment Airborne Monitor,Train B ERS-1400 Failed to Operate. Cause Unknown.Flush Channel Cleared + (08:11:33, 15 December 2024)
- ML20074A584 + (08:11:34, 15 December 2024)
- ML20074A583 + (08:11:34, 15 December 2024)
- 05000324/LER-1983-044-03, /03L-0:on 830408 & 09,during Unit Startup & Power Operations,Control Rods 02-27(02),34-03(04),34-23(02) & 30-11(03) Had No Indications for Identified Positions.Caused by Failed Position Reed Switches.Reed Switches Replaced + (08:11:37, 15 December 2024)
- ML20074A578 + (08:11:38, 15 December 2024)
- ML20074A577 + (08:11:39, 15 December 2024)
- 05000302/LER-1983-019, Forwards LER 83-019/03L-0 + (08:11:40, 15 December 2024)
- ML20074A575 + (08:11:40, 15 December 2024)
- 05000315/LER-1983-033, Forwards LER 83-033/03L-0 + (08:11:41, 15 December 2024)
- 05000324/LER-1983-044, Forwards LER 83-044/03L-0 + (08:11:41, 15 December 2024)
- 05000324/LER-1983-046-03, /03L-0:on 830410,wires to Terminals 13 & 14 in Terminal Box for MSIV 2-B21-F028A Found Reversed.Cause Undetermined.Wires Reterminated to Proper Terminals + (08:11:43, 15 December 2024)
- ML20074A567 + (08:11:44, 15 December 2024)
- 05000324/LER-1983-046, Forwards LER 83-046/03L-0 + (08:11:49, 15 December 2024)
- ML20074A559 + (08:11:50, 15 December 2024)
- 05000324/LER-1983-045, Forwards LER 83-045/03L-0 + (08:11:51, 15 December 2024)
- ML20074A558 + (08:11:51, 15 December 2024)
- 05000316/LER-1983-035, Forwards LER 83-035/03L-0 + (08:11:52, 15 December 2024)
- ML20074A550 + (08:11:52, 15 December 2024)
- ML20074A547 + (08:11:53, 15 December 2024)
- ML20074A549 + (08:11:53, 15 December 2024)
- ML20074A545 + (08:11:54, 15 December 2024)
- ML20074A546 + (08:11:54, 15 December 2024)
- ML20074A543 + (08:11:55, 15 December 2024)
- ML20074A541 + (08:11:56, 15 December 2024)
- ML20074A542 + (08:11:56, 15 December 2024)
- ML20074A534 + (08:11:57, 15 December 2024)
- ML20074A533 + (08:11:57, 15 December 2024)
- ML20074A532 + (08:11:58, 15 December 2024)
- 05000255/LER-1983-026-01, /01T-0:on 830428,sample from T-82D (Safety Tank D) Showed Boron Concentration Below Tech Spec Limit.Caused by Boron Dilution Due to Minor Leakage Past Loop Check Valve. Primary Coolant Leak Rate Monitored + (08:11:59, 15 December 2024)
- ML20074A530 + (08:12:00, 15 December 2024)
- 05000260/LER-1983-017-03, /03L-0:on 830409,hydrogen Analyzer B,H2AN-76-104 Declared Inoperable Due to Receipt of loss-of-flow Light 76-88.Caused by Moisture Collecting in Sample Lines.Lines Blown Down & Dried.Moisture Collection Devices to Be Added + (08:12:02, 15 December 2024)
- 05000255/LER-1983-026, Forwards LER 83-026/01T-0 + (08:12:03, 15 December 2024)