- 2CAN028402, Notifies of 840120 Svc Water Leak in Containment Cooling Coil 2VCC-2B,identified During IE Bulletin 80-24 Insp. Leakage to Containment Sump Indicated Approx 0.3 Gpm.Blanks Installed to Isolate Leaking Coils + (10:06:59, 14 December 2024)
- ML20083R540 + (10:06:59, 14 December 2024)
- 05000237/LER-1976-048-03, /03L-0:on 760630,unit Operator Noticed Average Power Range Monitor Channel 5 Indication Dropped 54% to 31% Power.Caused by Broken Lead on Dc Amplifier Connection Due to Poor Soldering.Connection Repaired + (10:07:01, 14 December 2024)
- 05000237/LER-1976-049-03, /03L-0:on 760711,core Spray Outboard Injection Valve Mo 2-1402-24B Lost Open/Closed Indication & Could Not Be Electrically Reopened.Caused by Broken Contact Block in Valve Operator.Switch Replaced + (10:07:03, 14 December 2024)
- ML20083R523 + (10:07:04, 14 December 2024)
- 05000237/LER-1976-050-03, /03L-0:on 760710,diesel Generator Cooling Water Pump Breaker Found in Tripped Condition.Caused by Excessive Temp in Breaker Cubicle.Breaker Reset.Pump Manually Started for Testing + (10:07:09, 14 December 2024)
- 05000237/LER-1976-051-03, /03L-0:on 760727,during Routine Surveillance Testing,Diesel Fire Pump 2/3 Failed to Start.Caused by Defective Shutdown Solenoid Valve.Valve Replaced.Engine Manually Started for Testing Purposes + (10:07:13, 14 December 2024)
- 05000237/LER-1976-052-03, /03L-0:on 760727,drywell High Pressure ECCS Initiation Switch Ps 1632A Found to Actuate at Greater than Tech Spec Limit.Cause Unknown.Switch Setpoint Immediately Adjusted + (10:07:15, 14 December 2024)
- ML20083R509 + (10:07:18, 14 December 2024)
- ML20083R513 + (10:07:18, 14 December 2024)
- ML20083R507 + (10:07:19, 14 December 2024)
- ML20083R501 + (10:07:24, 14 December 2024)
- 05000237/LER-1976-055-03, /03L-0:on 760817,post-maint Surveillance Test Performed on Standby Gas Train a Discovered Max Attainable Flow Below Tech Spec Limit.Caused by Dirty pre-HEPA Filter. Pre-HEPA Filter Replaced + (10:07:26, 14 December 2024)
- ML20083R490 + (10:07:26, 14 December 2024)
- 05000237/LER-1976-057-03, /03L-0:on 760821,instrument Trip Point for Reactor Water Level Instrument 2-263-57B Isolation Found Above Tech Spec Limit.Caused by Instrument Setpoint Drift.Trip Point Adjusted + (10:07:28, 14 December 2024)
- ML20083R483 + (10:07:30, 14 December 2024)
- ML20083R475 + (10:07:30, 14 December 2024)
- ML20083R424 + (10:07:33, 14 December 2024)
- ML20083R423 + (10:07:34, 14 December 2024)
- ML20083R420 + (10:07:35, 14 December 2024)
- ML20083R421 + (10:07:35, 14 December 2024)
- 05000387/LER-1984-021, :on 840323,during Installation of Mod to Emergency Svc Water Sys,Fire Barrier Wrapping of Several Cable Raceways Overlooked.Fire Watch Established & Will Remain Until Fire Barrier Wrapping Complete + (10:07:37, 14 December 2024)
- ML20083R391 + (10:07:38, 14 December 2024)
- ML20083R379 + (10:07:38, 14 December 2024)
- ML20083R357 + (10:07:39, 14 December 2024)
- ML20083R345 + (10:07:40, 14 December 2024)
- ML20083R337 + (10:07:41, 14 December 2024)
- ML20083R331 + (10:07:42, 14 December 2024)
- NRC-95-4463, Forwards Proprietary & Nonproprietary Versions of AP600 Testing Program Rept PCS-T2R-050, Large-Scale Test Data Evaluation. Proprietary Version of Rept Withheld from Public Disclosure Per 10CFR2.790.Also See 9809300271 + (10:07:45, 14 December 2024)
- ML20083R307 + (10:07:46, 14 December 2024)
- ML20083R312 + (10:07:46, 14 December 2024)
- ML20083R248 + (10:07:50, 14 December 2024)
- ML20083R234 + (10:07:51, 14 December 2024)
- 05000249/LER-1984-001-06, :on 840323,during Reactor Startup,Reactor Water Level Decreased to Low Level Alarm Point,Causing High Neutron Flux Reactor Scram.Cause Not Stated.Bypass Steam Flow Will Be Minimized in Future + (10:07:52, 14 December 2024)
- ML20083R219 + (10:07:53, 14 December 2024)
- ML20083R204 + (10:07:54, 14 December 2024)
- ML20083R208 + (10:07:54, 14 December 2024)
- ST-HL-AE-5089, Application for Amends to Licenses NPF-76 & NPF-80,allowing Performance of 24 H Surveillance Test of DG During Power Operation + (10:07:55, 14 December 2024)
- ML20083R190 + (10:07:57, 14 December 2024)
- ML20083R175 + (10:07:58, 14 December 2024)
- ML20083R161 + (10:07:59, 14 December 2024)
- ML20083R144 + (10:08:02, 14 December 2024)
- ML20083R142 + (10:08:02, 14 December 2024)
- ML20083R137 + (10:08:04, 14 December 2024)
- ML20083R140 + (10:08:04, 14 December 2024)
- ML20083R129 + (10:08:05, 14 December 2024)
- ML20083R133 + (10:08:05, 14 December 2024)
- ML20083R115 + (10:08:06, 14 December 2024)
- ML20083R109 + (10:08:07, 14 December 2024)
- ML20083R112 + (10:08:07, 14 December 2024)
- ML20083R102 + (10:08:08, 14 December 2024)