Search by property
Jump to navigation
Jump to search
This page provides a simple browsing interface for finding entities described by a property and a named value. Other available search interfaces include the page property search, and the ask query builder.
List of results
- ML20248E799 + (23:06:40, 1 December 2024)
- ML20248E800 + (23:06:40, 1 December 2024)
- ML20248E798 + (23:06:42, 1 December 2024)
- ML20248E797 + (23:06:42, 1 December 2024)
- ML20248E795 + (23:06:43, 1 December 2024)
- ML20248E794 + (23:06:43, 1 December 2024)
- ML20248E791 + (23:06:44, 1 December 2024)
- ML20248E789 + (23:06:45, 1 December 2024)
- ML20248E786 + (23:06:46, 1 December 2024)
- ML20248E788 + (23:06:46, 1 December 2024)
- ML20248E785 + (23:06:47, 1 December 2024)
- ML20248E783 + (23:06:48, 1 December 2024)
- ML20248E784 + (23:06:48, 1 December 2024)
- ML20248E780 + (23:06:49, 1 December 2024)
- ML20248E781 + (23:06:49, 1 December 2024)
- ML20248E778 + (23:06:50, 1 December 2024)
- ML20248E777 + (23:06:52, 1 December 2024)
- ML20248E775 + (23:06:53, 1 December 2024)
- ML20248E774 + (23:06:53, 1 December 2024)
- ML20248E773 + (23:06:56, 1 December 2024)
- 05000285/LER-1989-014, :on 890519,auxiliary Feedwater Panel Instrumentation Outside Design Basis Revealed.Caused by Deficiencies in Instrumentation.Fire Watch Established & Stated Abnormal Operating Procedure Modified + (23:07:02, 1 December 2024)
- ML20248E769 + (23:07:03, 1 December 2024)
- 05000352/LER-1989-051, :on 890831,control Room Emergency Fresh Air Supply Sys Inadvertently Secured from Chlorine Isolation Mode of Operation,Causing Sys Inoperability.Caused by Personnel Error.Isolation Manually Initiated + (23:07:06, 1 December 2024)
- ML20248E765 + (23:07:08, 1 December 2024)
- ML20248E764 + (23:07:09, 1 December 2024)
- ML20248E762 + (23:07:10, 1 December 2024)
- ML20248E761 + (23:07:11, 1 December 2024)
- ML20248E760 + (23:07:11, 1 December 2024)
- 05000254/LER-1989-001-03, :on 890106,RCIC Pump Discharge Inboard Isolation Valve Failed to Open from Full Closed Position. Caused by Binding of Torque Switch on Valve Operator.Switch Replaced.Reportability Per Part 21 Possible + (23:07:14, 1 December 2024)
- IR 05000416/1998005 + (23:07:17, 1 December 2024)
- ML20248E753 + (23:07:18, 1 December 2024)
- 05000254/LER-1989-002, :on 890109,total of Combined Local Leak Rate Test Interval on MSIV Exceeded Specified Surveillance Interval of 18 Months.Caused by Misinterpretation of Tech Specs.Tech Specs Revised + (23:07:20, 1 December 2024)
- ML20248E750 + (23:07:21, 1 December 2024)
- ML20248E748 + (23:07:22, 1 December 2024)
- ML20248E746 + (23:07:23, 1 December 2024)
- ML20248E743 + (23:07:23, 1 December 2024)
- ML20248E740 + (23:07:24, 1 December 2024)
- ML20248E742 + (23:07:24, 1 December 2024)
- ML20248E738 + (23:07:27, 1 December 2024)
- ML20248E737 + (23:07:28, 1 December 2024)
- ML20248E733 + (23:07:29, 1 December 2024)
- ML20248E729 + (23:07:30, 1 December 2024)
- ML20248E728 + (23:07:31, 1 December 2024)
- 05000354/LER-1989-017-01, :on 890830,reactor Scram Occurred Due to Result of Low Reactor Pressure Vessel Water Level Signal.Caused by Installation of Air Line Failure During Plant Const.Leak Check of All Soldered Connections Done + (23:07:32, 1 December 2024)
- 05000325/LER-1988-028, :on 881123,pipe Crack Indications Revealed Existence of 238 Indications in 19 of 65 Welds.Caused by IGSCC of Associated Welds.Addl Testing,Repair &/Or Mods Will Be Conducted Per Generic Ltr in Future Outages + (23:07:35, 1 December 2024)
- IR 05000260/1989036 + (23:07:59, 1 December 2024)
- IR 05000361/1998001 + (23:08:07, 1 December 2024)
- ML20248E718 + (23:08:07, 1 December 2024)
- ML20248E713 + (23:08:11, 1 December 2024)
- U-603011, Informs That MD Needles,License SOP-31108-1,LT Pickley, License SOP-31018-1,FE Worrel,License SOP-30547-2 & Me Mcclure,License OP-30894,no Longer Have Need for Operator/Senior Operator License + (23:08:12, 1 December 2024)
- IR 05000313/1989007 + (23:08:15, 1 December 2024)