- ML20235W758 + (ML20235W758)
- ML20235W759 + (ML20235W759)
- ML20235W760 + (ML20235W760)
- ML20235W764 + (ML20235W764)
- PNO-I-87-094, on 871013,explosion & Fire Occurred in Main Transformer Phase a Causing Turbine Generator Trip.Cause of Fire Unknown.Licensee Fire Dept Responded & Automatic Water Deluge Sys initiated.One-wk Outage Anticipated + (ML20235W765)
- IR 05000321/1988031 + (ML20235W767)
- ML20235W768 + (ML20235W768)
- ML20235W769 + (ML20235W769)
- ML20235W771 + (ML20235W771)
- ML20235W772 + (ML20235W772)
- ML20235W774 + (ML20235W774)
- ML20235W776 + (ML20235W776)
- ML20235W777 + (ML20235W777)
- ML20235W781 + (ML20235W781)
- ML20235W782 + (ML20235W782)
- ML20235W783 + (ML20235W783)
- ML20235W787 + (ML20235W787)
- LD-87-145, Provides Supplemental Info Re Decontamination of NAC-1E Spent Fuel Shipping Cast.All Removable Cast Parts Exposed to Decontamination Procedure Replaced & O-ring Annulus Pressure Tested to Verify Containment + (ML20235W789)
- ML20235W791 + (ML20235W791)
- ML20235W797 + (ML20235W797)
- ML20235W801 + (ML20235W801)
- ML20235W802 + (ML20235W802)
- ML20235W804 + (ML20235W804)
- ML20235W806 + (ML20235W806)
- PY-CEI-NRR-0685, Forwards Rept of Changes to Initial Test Program,Per License Condition 2.C(4) & 10CFR50.59(b).Rept Includes All Such Changes Made from 870612-0702 + (ML20235W809)
- ML20235W810 + (ML20235W810)
- ML20235W811 + (ML20235W811)
- ST-HL-AE-2343, Requests Schedular Exemption from 10CFR50.71(e) Requirements to Allow Delay in Submittal of Updated FSAR Until 1 Yr After Issuance of Unit 2 Ol.Maint of FSAR as Description of Both Units Requested.Amends for Submittal Listed.Fee Paid + (ML20235W813)
- ML20235W815 + (ML20235W815)
- ML20235W816 + (ML20235W816)
- ML20235W820 + (ML20235W820)
- ML20235W821 + (ML20235W821)
- ML20235W822 + (ML20235W822)
- ML20235W825 + (ML20235W825)
- ML20235W826 + (ML20235W826)
- ML20235W827 + (ML20235W827)
- ML20235W832 + (ML20235W832)
- ML20235W833 + (ML20235W833)
- ML20235W835 + (ML20235W835)
- ML20235W838 + (ML20235W838)
- 05000282/LER-1987-009-01, :on 870618,safety Injection Pump 11 Did Not Start When Given Start Signal.Caused by Failure to Leave Ite Type 5HK250 4160V Breaker Completely Racked in & Lack of Specific Procedures for Racking Breakers + (ML20235W839)
- ML20235W840 + (ML20235W840)
- ML20235W841 + (ML20235W841)
- PNO-II-87-068, on 871009,auxiliary Nuclear Operator Removed Lead Brick Shielding from Reactor Cavity Access in Order to Facilitate Leak Detention & Dose Rate Instrument Pegged Offscale.Nrc Radiation Specialist Dispatched to Site + (ML20235W842)
- L-87-295, Forwards Rept of Brief Description of Plant Changes/Mods (Pcms) Made Under Provisions of 10CFR50.59,including Summary of Safety Evaluation for Each.Rept Includes PCMs Completed Between 860123-870122 & Correlates W/Rev 6 of Updated FSAR + (ML20235W844)
- ML20235W846 + (ML20235W846)
- ML20235W847 + (ML20235W847)
- ML20235W849 + (ML20235W849)
- ML20235W852 + (ML20235W852)
- ML20235W855 + (ML20235W855)
- ML20235W856 + (ML20235W856)