- ML20214P587 + (ML20214P587)
- DCL-86-334, Responds to IE Bulletin 86-003, Potential Failure of Multiple ECCS Pumps Due to Single Failure of Air-Operated Valve in Min Flow Recirculation Line. Problem Does Not Exist at Facilities.Eccs Composite Drawing Encl + (ML20214P589)
- 05000443/LER-1987-014, :on 870429,vital Bus E6 Tripped,Resulting in Starting & Loading of Diesel Generator 1B.Caused by Deficiency in Procedure Used to Measure Relay Response Time. Procedure Revised + (ML20214P590)
- ML20214P591 + (ML20214P591)
- ML20214P595 + (ML20214P595)
- ML20214P597 + (ML20214P597)
- ML20214P598 + (ML20214P598)
- ML20214P599 + (ML20214P599)
- ML20214P600 + (ML20214P600)
- 05000325/LER-1986-021, :on 860819,automatic Scram Occurred Due to Main Turbine Trip/Stop Valve Fast Closure from Main Turbine Master Trip Signal.Caused by Electrical Grounding of Dc Power Supply of Limit Switch + (ML20214P601)
- ML20214P602 + (ML20214P602)
- ML20214P606 + (ML20214P606)
- 05000275/LER-1986-016-01, :on 861027,fiberscope Insp Revealed That Retainer Nut That Attaches Check Valve Disc to Tail Link Loose or Missing on Two of Four Check Valves.Caused by Poor Mfg Design.Design Change Implemented + (ML20214P608)
- ML20214P609 + (ML20214P609)
- 05000244/LER-1986-006, :on 860816,boric Acid Transfer Pump Inoperable. Caused by Valve V-331 Misalignment.Valves V-331 & V-345 on Transfer Pumps a & B Locked Open.Technician Reminded to Receive Permission + (ML20214P610)
- ML20214P612 + (ML20214P612)
- B12530, Application for Amend to License DPR-21,revising Tech Specs 3.4,4.4 & Associated Bases to Comply W/Atws Rule (10CFR50.62) That Requires All BWRs to Have Standby Liquid Control Sys W/Min Flow Capacity.Fee Paid + (ML20214P614)
- IA-86-687, Forwards SER Re Licensee 860917 & 19 Ltrs Proposing one-time Change to Tech Specs,Removing Operability Requirements from Automatic Isolation Valve in 3/4 Line That Bypasses RCIC Inboard Isolation Valve.Salp Input Also Encl + (ML20214P615)
- ML20214P615 + (ML20214P615)
- ML20214P616 + (ML20214P616)
- ML20214P619 + (ML20214P619)
- ML20214P621 + (ML20214P621)
- TXX-5011, Interim Deficiency Rept CP-86-55 Re Seismic Air Gap Design Adequacy.Initially Reported on 860814.Review of Calculations for Acceptability of Existing Design Gap Scheduled for Completion by 861031.Next Rept Expected by 861121 + (ML20214P622)
- ML20214P623 + (ML20214P623)
- ML20214P625 + (ML20214P625)
- ML20214P626 + (ML20214P626)
- ML20214P631 + (ML20214P631)
- IR 05000374/1986023 + (ML20214P632)
- ML20214P636 + (ML20214P636)
- ML20214P639 + (ML20214P639)
- ML20214P642 + (ML20214P642)
- ML20214P643 + (ML20214P643)
- ML20214P646 + (ML20214P646)
- ML20214P647 + (ML20214P647)
- ML20214P648 + (ML20214P648)
- ML20214P649 + (ML20214P649)
- 05000298/LER-1986-017, :on 860818,HPCI Steam Supply Valve Isolation Challenged During Normal Operation.Caused by Troubleshooting W/Inadequate Guidance.Instrument & Control Supervisor Emphasized Need for Preplanning to Personnel + (ML20214P652)
- ML20214P653 + (ML20214P653)
- ML20214P654 + (ML20214P654)
- ML20214P655 + (ML20214P655)
- ML20214P656 + (ML20214P656)
- ML20214P657 + (ML20214P657)
- ML20214P659 + (ML20214P659)
- ML20214P660 + (ML20214P660)
- ML20214P661 + (ML20214P661)
- IR 05000285/1986005 + (ML20214P663)
- ML20214P664 + (ML20214P664)
- ML20214P665 + (ML20214P665)
- ML20214P668 + (ML20214P668)
- 05000219/LER-1987-019, :on 870330,limiting Safety Sys Setpoint for Total Recirculation Flow Exceeded Tech Specs.Caused by Personnel Error.Surveillance Procedure Revised to Specify Use of More Accurate Flowmeter + (ML20214P670)
- ML20214P671 + (ML20214P671)