- B12416, Discusses Implementation Status of App R Mods Required by Current App R Fire Protection Analysis.All Nonoutage Mods Completed & Remaining Mods to Be Completed Prior to End of 1987/1988 Refueling Outage + (ML20211H339)
- ML20211H340 + (ML20211H340)
- 05000318/LER-1986-004, :on 860521 & 27,reactor Manually Tripped from 100% Power Due to Low Steam Generator Water Level. Caused by Erroneous Control Signal from Double Ground. Grounded Components Repaired + (ML20211H342)
- ML20211H345 + (ML20211H345)
- ML20211H346 + (ML20211H346)
- 05000461/LER-1997-009-01, Forwards LER 97-009-01 Re Identification of Surveillance Procedure Which Does Not Adequately Consider Accuracy of Installed Instrumentation in Meeting TS Requirements for Reactor Core Isolation Cooling Pump.Commitments,Liste + (ML20211H348)
- ML20211H349 + (ML20211H349)
- ML20211H350 + (ML20211H350)
- ML20211H353 + (ML20211H353)
- ML20211H355 + (ML20211H355)
- 05000423/LER-1986-036, :on 860519,facility Operating Under Tech Spec 3.8.2.1.b Action Statement W/Battery Bank 301a-2 Inoperable Due to Unperformed Mod to Battery Charger.Seismic Bracing Designed & Installed on Battery Charger + (ML20211H356)
- ML20211H357 + (ML20211H357)
- ML20211H359 + (ML20211H359)
- ML20211H362 + (ML20211H362)
- 05000249/LER-1986-005-09, :on 860519,emergency Diesel Generator Automatically Started & Closed 4-kV Bus 34-1 Due to Undervoltage Condition on Bus.Caused by Personnel Error. Individual Counseled + (ML20211H363)
- U-602843, Provides Revised Response to Violations Noted in Insp Rept 50-461/97-06.Corrective Actions:Replaced Deformed Piping on B RR Loop Drain Line,Performed Review of Similar Freeze Seal Incidents & Contracted Freeze Seal Activity to Vendor + (ML20211H364)
- NG-97-1348, Submits QA Program Description for DAEC in Accordance W/ Requirements of 10CFR50.54(a)(3).Program Description Relocates Listed Info from Current Ts,None of Which Is Reduction in Commitment + (ML20211H368)
- ML20211H373 + (ML20211H373)
- ML20211H374 + (ML20211H374)
- ML20211H376 + (ML20211H376)
- ML20211H377 + (ML20211H377)
- ML20211H379 + (ML20211H379)
- 05000286/LER-1986-004-01, :on 860519,source-range (SR) high-flux Reactor Trip Initiated Automatically by Nuclear Instrumentation Sys. Caused by Operator Failure to Block SR Instrumentation During Startup.Operator Counseled + (ML20211H380)
- ML20211H381 + (ML20211H381)
- ML20211H383 + (ML20211H383)
- ML20211H384 + (ML20211H384)
- TXX-6296, Interim Deficiency Rept CP-86-36 Re Large Bore Piping & Supports.Initially Reported on 860609.Continued Engineering Evaluation Has Not Identified Addl Reportable Instances.Next Rept Will Be Submitted by 870410 + (ML20211H385)
- U-602826, Requests Withdrawal of License Amend Application & Exemption from Requirements of 10CFR50,App a General Design Criterion 17, Electric Power Systems + (ML20211H386)
- ML20211H387 + (ML20211H387)
- ML20211H392 + (ML20211H392)
- ML20211H393 + (ML20211H393)
- TXX-6290, Interim Deficiency Rept CP-86-67 Re Preoperational Vibrational Test Criteria.Initially Reported on 860926. Evaluation Continuing.Next Rept Expected by 870319 + (ML20211H394)
- ML20211H396 + (ML20211H396)
- ML20211H397 + (ML20211H397)
- ML20211H398 + (ML20211H398)
- 05000311/LER-1987-002-01, :on 870118,wile Performing Troubleshooting on Nuclear Instrument Sys intermediate-range Channel N36, Reactor Trip Occurred.Caused by Personnel Error.Signs Placed to Caution Personnel Re Pulling Fuses + (ML20211H399)
- ML20211H400 + (ML20211H400)
- 05000219/LER-1986-010-01, :on 860513,while in Cold Shutdown,Hydraulic Snubbers NE-1-S4,NE-1-S5 & NE-2-S13 Found to Have Associated Pipe Clamp to Shear Lug Welds Missing.Caused by Personnel Error Due to Inadequate Vendor Followup + (ML20211H401)
- ML20211H402 + (ML20211H402)
- ML20211H404 + (ML20211H404)
- ML20211H405 + (ML20211H405)
- ML20211H406 + (ML20211H406)
- ML20211H407 + (ML20211H407)
- IR 05000508/1986012 + (ML20211H410)
- ML20211H412 + (ML20211H412)
- ML20211H413 + (ML20211H413)
- TXX-6063, Interim Deficiency Rept CP-85-26 Re Steam Generator Upper Lateral Restaint Embedment Design.Initially Reported on 850719.Analysis of Issue Based on Revised Loadings on Beams & Beam Connections.Next Rept Expected by 861203 + (ML20211H414)
- ML20211H415 + (ML20211H415)
- 05000271/LER-1986-006, :on 860521,unanticipated Full Scram Signal Received While Testing/Troubleshooting Local power-range Monitor (LPRM) Cables.Caused by Connection of LPRM Test Instrument Detector to APRM Electronics + (ML20211H416)
- ML20211H420 + (ML20211H420)
- ML20211H421 + (ML20211H421)