- ML20209H939 + (ML20209H939)
- ML20209H940 + (ML20209H940)
- AECM-85-0344, Responds to Violations Noted in Insp Rept 50-416/85-33. Corrective Actions:Ltr Issued Re Compliance w/safety-related Procedures & Surveillance Procedures Revised to Include Test Port Flanges + (ML20209H942)
- ML20209H944 + (ML20209H944)
- ML20209H947 + (ML20209H947)
- ML20209H948 + (ML20209H948)
- ML20209H949 + (ML20209H949)
- 0CAN079901, Application for Amends to Licenses DPR-51 & NPF-6 to Change TS & Subsequent Relief Request from Post Accident Sampling Requirements of NUREG-0737.TS Administrative Control requirements,NUREG-0737 & RG 1.97,rev 3,affected + (ML20209H950)
- ML20209H953 + (ML20209H953)
- ML20209H955 + (ML20209H955)
- ML20209H956 + (ML20209H956)
- ML20209H957 + (ML20209H957)
- ML20209H958 + (ML20209H958)
- W3P87-1115, 1986 Annual Environ Operating Rept + (ML20209H959)
- ML20209H961 + (ML20209H961)
- ML20209H962 + (ML20209H962)
- ML20209H963 + (ML20209H963)
- ML20209H964 + (ML20209H964)
- ML20209H965 + (ML20209H965)
- ML20209H966 + (ML20209H966)
- ML20209H968 + (ML20209H968)
- ML20209H969 + (ML20209H969)
- ML20209H970 + (ML20209H970)
- ML20209H971 + (ML20209H971)
- ML20209H972 + (ML20209H972)
- ML20209H976 + (ML20209H976)
- ML20209H980 + (ML20209H980)
- ML20209H983 + (ML20209H983)
- ML20209H984 + (ML20209H984)
- ML20209H985 + (ML20209H985)
- ML20209H986 + (ML20209H986)
- ML20209H988 + (ML20209H988)
- 05000414/LER-1999-004-02, :on 990610,violation of TS 3.6.3 Was Noted Due to CIV 2NM-221A Being Returned to Service Without Testing. Caused by Procedure Deficiency.Civ 2NM-221A Was Tested & Returned to Operable Status + (ML20209H990)
- ML20209H991 + (ML20209H991)
- W3P86-3304, Forwards Gw Muench 860910 Executed Affidavit to Replace Unexecuted Affidavit Submitted w/ Re Tech Spec Changes + (ML20209H994)
- ML20209H997 + (ML20209H997)
- ML20209J000 + (ML20209J000)
- ML20209J001 + (ML20209J001)
- ML20209J003 + (ML20209J003)
- ML20209J004 + (ML20209J004)
- 05000285/LER-1987-006, :on 870327,unplanned Actuation of Channel B Containment Pressure High Signal (Cphs) Occurred.Caused When Instrument Tees Left Capped & Cphs Setpoints Exceeded by Technician.Technicians Instructed + (ML20209J007)
- ML20209J008 + (ML20209J008)
- ML20209J014 + (ML20209J014)
- 05000285/LER-1987-007, :on 870326,incorrect Wiring of Containment post-accident Water Level Transmitter Failed to Give Correct Indication During Surveillance Test.Caused by Technician Error.Procedures Revised + (ML20209J017)
- ML20209J018 + (ML20209J018)
- B17814, Special Rept:On 990612 B Train EDG Failed to Restart within 5 Minutes Following Completion of 18 Month 24 H Endurance Run Required by TS 4.8.1.1.2.g.7.Caused by Procedural inadequacy.Re-performed Hot Restart Via Manual Start + (ML20209J020)