- 05000237/LER-1985-010-03, :on 850305,fire Door for 125-volt Battery Room Encl Found Open W/O Fire Watch Established within 1 H Per Tech Spec 3.12.F.2.Cause Under Investigation.Suppl Will Be Issued on 850410 W/Results of Investigation + (ML20113C001)
- 05000454/LER-1985-034, :on 850318,during MSIV Operability Test, Operator Accidentally Actuated Manual Safety Injection Handswitch Instead of Manual Main Steam Isolation Handswitch.Operators Reminded to Read Labels + (ML20113C017)
- RBG-42966, Submits Response to Violations Noted in Insp Rept 50-458/96-03.Corrective Actions:Maint Investigated Problem, Identified,Relay Removed from Base & After Coordination W/ Main Cr,Replaced Relay + (ML20113C038)
- 05000254/LER-1996-009-01, :on 960523,noted Discrepancy in Cable Length Modeled in Existing Degraded Voltage Calculations.Caused by Design Analysis Deficiency.Performed Design Changes to Correct Voltage Problems + (ML20113C043)
- ML20113C045 + (ML20113C045)
- 05000250/LER-1984-033, :on 841213,reactor Trip Occurred Due to Generator Trip & Subsequent Turbine Trip.Caused by Fault in Exciter Created by Shorting of Dc to Ac Side of Rotor. Exciter Rotor Replaced + (ML20113C052)
- L-96-158, Rev 2 to Jm Farley Nuclear Plant Units 1 & 2 Licensing Rept for TS Changes Associated W/Revised Core Limits,Revised Trip Setpoints & Inclusion of RAOC Control Strategy + (ML20113C053)
- ML20113C054 + (ML20113C054)
- ML20113C060 + (ML20113C060)
- ML20113C069 + (ML20113C069)
- 05000250/LER-1984-034, :on 841213,containment Isolation Valve CV-3-204 Remained Open.Caused by Malfunction of Solenoid Valve.Air Supply to Valve Secured.Solenoid Valve Removed,Tested & Replaced + (ML20113C073)
- ML20113C085 + (ML20113C085)
- ML20113C104 + (ML20113C104)
- ML20113C108 + (ML20113C108)
- ML20113C118 + (ML20113C118)
- 05000461/LER-1996-006, :on 960529,degraded Control Room HVAC Train Declared Inoperable.Caused by Personnel Error.Briefed Personnel Re Event & Developed Standing Order + (ML20113C128)
- ML20113C136 + (ML20113C136)
- ML20113C137 + (ML20113C137)
- ML20113C148 + (ML20113C148)
- NSD-NRC-96-4754, Forwards Westinghouse Responses to NRC Requests for for Addl Info on AP600 + (ML20113C149)
- ML20113C153 + (ML20113C153)
- PY-CEI-NRR-2060, Responds to Request for Addl Info Re GL 95-07, Pressure Locking & Thermal Binding of Safety-Related Power-Operated Gate Valves + (ML20113C156)
- ML20113C157 + (ML20113C157)
- ML20113C158 + (ML20113C158)
- ML20113C177 + (ML20113C177)
- LD-96-024, Transmits Finalized Package of Changes to Sys 80+ Std Plant Design Control Document + (ML20113C181)
- ML20113C188 + (ML20113C188)
- ML20113C192 + (ML20113C192)
- 05000397/LER-1985-021, :on 850307,reactor Recirculation Flow Control Valve B Hydraulic Power Unit (HY-HP-3B) Tripped Off & Valves HY-V-17B,18B,19B,20B,33B,34B,35B & 36B Closed. Investigations Yielded No Apparent Cause + (ML20113C194)
- ML20113C207 + (ML20113C207)
- 05000387/LER-1985-008-01, :on 850302,standby Gas Treatment Sys & Control Room Emergency Outside Air Supply Sys Actuated.Caused by Electricians Working on Mod to Reactor Protection Sys B Alternate Power Source Transformer + (ML20113C208)
- ML20113C212 + (ML20113C212)
- ML20113C213 + (ML20113C213)
- ML20113C214 + (ML20113C214)
- ML20113C217 + (ML20113C217)
- ML20113C220 + (ML20113C220)
- ML20113C221 + (ML20113C221)
- ML20113C222 + (ML20113C222)
- ML20113C225 + (ML20113C225)
- ML20113C231 + (ML20113C231)
- ML20113C234 + (ML20113C234)
- ML20113C237 + (ML20113C237)
- ML20113C239 + (ML20113C239)
- ML20113C240 + (ML20113C240)
- ML20113C245 + (ML20113C245)
- ML20113C254 + (ML20113C254)
- ML20113C256 + (ML20113C256)
- ML20113C259 + (ML20113C259)
- ML20113C261 + (ML20113C261)
- ML20113C263 + (ML20113C263)
- ML20113C270 + (ML20113C270)