%,.....j SAFETY EVALUATION BY THE OFFICE OF NUCLEAR REACTOR REGULATION RELATED TO AMENDMENT NO.105 TO FACILITY OPERATING LICENSE NO. NPF-62 ILLIN0IS POWER COMPANY. ET AL.

CLINTON POWER STATION. UNIT NO. 1 DOCKET NO. 50-461

1.0 INTRODUCTION

On September 12, 1995, the U.S. Nuclear Regulatory Commission (NRC) approved issuance of a revision to 10 CFR Part 50, Appendix J, " Primary Reactor Containment Leakage Testing for Water-Cooled Power Reactors" which was subsequently published in the Federal Reaister on September 26, 1995, and became effective on October 26, 1995.

The NRC added Option B " Performance-Based Requirements" to allow licensees to voluntarily replace the prescriptive testing requirements of 10 CFR Part 50, Appendix J, with testing requirements based on both overall leakage rate performance and the performance of individual components.

By application dated May 1, 1996, Illinois Power Company, (IP, the licensee)

)

requested changes to the Operating License and Technical Specifications (TS) for the Clinton Power Station (CPS). The proposed changes would permit implementation of 10 CFR Part 50, Appendix J - Option B.

The licensee has established a " Containment Leakage Rate Testing Program" and proposed adding this program to the TS. The program references Regulatory Guide (RG) 1.163,

" Performance-Based Containment Leak Test Program," dated September 1995, which specifies a method acceptable to the NRC for complying with Option B.

2.0 BACKGROUND

Compliance with 10 CFR Part 50, Appendix J, provides assurance that the primary containment, including those systems and components which penetrate the primary containment, do not exceed the allowable leakage rate specified in the TS and Bases. The allowable leakage rate is determined so that the leakage assumed in the safety analyses is not exceeded.

On February 4,1992, the NRC published a notice in the Federal Reaister (57 FR 4166) discussing a planned initiative to begin eliminating requirements marginal to safety which impose a significant regulatory burden. Appendix J of 10 CFR Part 50 was considered for this initiative and the staff undertook a study of possible changes to this regulation. The study examined the previous performance history of domestic containments and examined the effect on risk of a revision to the requirements of Appendix J.

The results of this study are reported in NUREG-1493, " Performance-Based Leak-Test Program."

9606290218 960621 PDR ADOCK 05000461 P

PDR

~

Based on the results of this study, the staff developed a performance-based approach to containment leakage rate testing. On September 12, 1995-the NRC approved issuance of this revision to 10 CFR Part 50, Appendix J, which became effective on October 26, 1995.

The revision added Option B " Performance-Based Requirenents" to Appendix J to allow licensees to voluntarily replace the prescriptive testing requirements of Appendix J with testinit requirements based on both overall and individual component leakage rate performance.

Regulatory Guide 1.163, was developed as a method acceptable to the NRC staff for implementing Option B.

This regulatory guide states that the Nuclear Energy Institute (NEI) guidance document NEI 94-01, " Industry Guideline for Implementing Performance-Based Option of 10 CFR Part 50, Appendix J" provides methods acceptable to the NRC staff for complying with Option B with four exceptions which are described therein.

i Option B requires that the RG or other implementation document used by a licensee to develop a performance-based leakage rate testing program must be included, by general reference, in the plant TS.

The licensee has referenced RG 1.163 in the CPS TS.

Regulatory Guide 1.163 specifies an extension in Type A test frequency to at least one test in 10 years based upon two consecutive successful tests. Type l

l B tests may be extended up to a maximum interval of 10 years based upon completion of two consecutive successful tests and Type C tests may be i

1 extended up to 5 years based on two consecutive successful tests.

By letter dated October 20, 1995, NEI proposed TS to implement Option B.

After some discussion, the staff and NEI agreed on final TS which were j

1 attached to a letter from C. Grimes (NRC) to D. Modeen (NEI) dated November 2, 1995.

These TS are to serve as a model for licensees to develop plant specific TS in preparing amendment requests to implement Option B.

For a licensee to determine the performance of each component, factors that are indicative of or affect performance, such as an administrative leakage limit, must be established. The administrative limit is selected to be indicative of the potential onset of component degradation.

Although these limits are subject to NRC inspection to assure that they are selected in a reasonable manner, they are not TS requirements.

Failure to meet an administrative limit requires the licensee to return to the minimum value of the test interval.

Option B requires that the licensee maintain records to show that the criteria for Type A, B and C tests have been met.

In addition, the licensee must maintain performance comparisons of the overall containment system and individual components to show that the test intervals are adequate.

These records are subject to NRC inspection.

3.0 EVALUATION In its May 1,1996, letter, the licensee proposed establishing a " Containment Leakage Rate Testing Program" and proposed adding this program to the TS.

The program references RG 1.163, which specifies a method acceptable to the NRC

j

},.

for complying with Option B.

The proposal requires a change to existing TS Section 1.1, " Definitions;" TS 3.6.1.1, " Primary Containment;" TS 3.6.1.2,

" Primary Containment Air Locks;" TS 3.6.1.3, " Primary Containment Isolation i

Valves (PCIVs);" and the addition of the " Primary Containment Leakage Rate Testing Program" to TS Section 5.5, " Programs and Manuals." Corresponding i

bases will also be modified.

j i

Option B permits a licensee to choose Type A; or Type B and C; or Type A, B and C; testing to be done on a performance basis. The licensee has elected to j

perform Type A, B and C testing on a performance basis.

1 j

The TS changes proposed by the licensee are in compliance with the j

requirements of Option B and consi-tent with the guidance of RG 1.163, and the generic TS of the November 2,1995, letter and are, therefore, acceptable to the staff, i

In addition to the TS changes discussed above, the licensee proposed changes to the CPS Operating License relating to its current exemptions to 10 CFR 50, 2

j Appendix J, Option A.

Paragraph V.B.1 of 10 CFR Part 50, Appendix J - Option B, states that specific exemptions to Option A are still applicable to Option j

B, if necessary, unless specifically revoked by the NRC.

k Paragraph 2.0 of the CPS Operating License currently lists four exemptions from the requirements of 10 CFR Part 50, Appendix J - Option A.

The licensee evaluated these existing exemptions from Option A against the new requirements of Option B and determined that two of the exemptions are no longer applicable. These exemptions are: (1) an exemption from paragraph l

III.D.2(b)(ii) to permit substituting the air lock door seal leakage for the i

entire primary containment air lock test; and (2) an exemption from paragraph III.D.I.(a) pertaining to the requirement to conduct the third Type A test i

during the last outage within the 10-year inservice inspection interval.

The licensee determined that the other two exemptions remain applicable to i

Option B.

These exemptions are:

(1) an exemption from paragraph III.C.3 of i

Option A (III.B of Option B) which exempts main steam isolation valve (MSIV) leakage from inclusion in the combined Type B and C test total leakage; and 1

(2) an exemption from paragraph III.B.3 of Option A (III.B of Option B)

{

pertaining to valve IE51-F374 which permits the packing and body-to-bonnet leakage to be excluded from the local leak rate test boundary, and instead allows the valve to be subjected to a soap solution test during each integrated leak rate test (ILRT).

t The staff has reviewed the licensee's proposed disposition of its existing (Option A) Appendix J exemptions as they relate to the Option B requirements, and pursuant to the provisions of 10 CFR Part 50, Appendix J - Option B, i

paragraph III.V.B.1, finds it acce > table. Also, the staff finds that the licensee's proposed revisions to tte CPS Operating License paragraph 2.D l

accurately reflect the changes discussed above.

4.0 STATE CONSULTATION

In accordance with the Commission's regulations, the Illinois state Official was notified of the proposed issuance of the amendment. The state official had no comments.

a

= -

5.0 ENVIRONMENTAL CONSIDERATION

The ame~ndment changes a requirement with respect to installation or use of a facility component located within the restricted area as defined in 10 CFR Part 20 and changes surveillance requirements. This also changes surveillance requirements. The NRC staff has determined that the amendment involves no significant increase in the amounts, and no significant change in the types, of any effluents that may be released offsite, and that there is no significant increase in individual or cumulative occupational radiation exposure. The Commission has previously issued a proposed finding that the amendment involves no significant hazards consideration, and there has been no public comment on such finding (61 FR 25708). Accordingly, the amendment meets the eligibility criteria for categorical exclusion set forth in 10 CFR 51.22(c)(9).

Pursuant to 10 CFR 51.22(b) no environmental impact statement or environmental assessment need be prepared in connection with the issuance of the amendment.

6.0 CONCLUSION

The Commission has concluded, based on the considerations discussed above, that (1) there is reasonable assurance that the health and safety of the public will not be endangered by operation in the proposed manner, (2) such activities will be conducted in compliance with the Commission's regulations, and (3) the issuance of the amendment will not be inimical to the common defense and security or to the health and safety of the public.