Search by property
Jump to navigation
Jump to search
This page provides a simple browsing interface for finding entities described by a property and a named value. Other available search interfaces include the page property search, and the ask query builder.
List of results
- 05000382/LER-1984-001, :on 841225,while in Mode 6,first of Five Automatic Actuations of Control Room Ventilation Sys Occurred.Caused by Electrical Spikes on Control Room Outside Air Intake Radiation Monitors.Signals Cleared + (ML20101T125)
- ML20101T126 + (ML20101T126)
- 05000416/LER-1984-060, :on 841228,main Turbine Overspeed Protection Sys Surveillance Not Performed within 14 Days as Required When Plant Operation in Modes 1 & 2.Caused by Personnel Error.Item Included in Computer Tracking Sys + (ML20101T129)
- ML20101T131 + (ML20101T131)
- ML20101T138 + (ML20101T138)
- ML20101T143 + (ML20101T143)
- ML20101T156 + (ML20101T156)
- ML20101T161 + (ML20101T161)
- 05000317/LER-1992-003-01, :on 920521,MSIV Pipe Tunnel Fire Damper Found Inoperable Due to Surveillance Test Procedure Omission. Inoperable Fire Damper Repaired.Findings Re Inoperable Spring Latch Will Be Reported in Rept Suppl + (ML20101T166)
- ML20101T169 + (ML20101T169)
- NRC-92-0078, Monthly Operating Rept for June 1992 for Fermi Unit 1.W/ + (ML20101T188)
- ML20101T191 + (ML20101T191)
- ML20101T194 + (ML20101T194)
- ML20101T195 + (ML20101T195)
- ML20101T199 + (ML20101T199)
- 05000298/LER-1992-008-01, :on 920611,HPCI Sys Discovered Inoperable Due to Stem Nut Wear of Mov.Worn Stem Nut Replaced.Independent Failure Evaluation of Stripped Stem Nut Being Performed.W/ + (ML20101T206)
- 05000443/LER-1992-007, :on 920617,A Train Containment Encl Emergency Air Cleanup Sys Discovered Inoperable Due to Personnel Error.Appropriate TS Statement Entered & Inoperable Equipment Returned to Operable Status + (ML20101T212)
- 05000338/LER-1984-013, :from 840910-25,liquid Radwaste Discharged W/O Treatment W/Projected Doses to Unrestricted Areas in Excess of Limits Specified in Tech Spec 3.11.1.3.Caused by Inadequate Checking of Demineralizers + (ML20101T213)
- ML20101T217 + (ML20101T217)
- ML20101T284 + (ML20101T284)
- ML20101T302 + (ML20101T302)
- 05000454/LER-1985-002, :on 850109,gas Monitor Channels on Radiation Monitor OPR33J Went Into High Radiation.Caused by Externally Generated Electrical Noise.Source of Noise Spike Unknown. Investigation Underway + (ML20101T315)
- ML20101T326 + (ML20101T326)
- ML20101T328 + (ML20101T328)
- ML20101T335 + (ML20101T335)
- ML20101T339 + (ML20101T339)
- ML20101T346 + (ML20101T346)
- ML20101T349 + (ML20101T349)
- ML20101T353 + (ML20101T353)
- ML20101T357 + (ML20101T357)
- ML20101T358 + (ML20101T358)
- ML20101T359 + (ML20101T359)
- ML20101T370 + (ML20101T370)
- ML20101T372 + (ML20101T372)
- ML20101T380 + (ML20101T380)
- ML20101T382 + (ML20101T382)
- ML20101T387 + (ML20101T387)
- 2CAN079208, Monthly Operating Rept for June 1992 for Ano,Unit 2 + (ML20101T391)
- ML20101T392 + (ML20101T392)
- ML20101T393 + (ML20101T393)
- 05000278/LER-1985-016, :on 841224,HPCI Turbine Exhaust Rupture Diaphragm Alarm Annunciated During Operation of HPCI Turbine.Caused by Failure of Inner Rupture Disk PSD3-23-6. Rupture Disk Replaced + (ML20101T398)
- ML20101T399 + (ML20101T399)
- ML20101T400 + (ML20101T400)
- ML20101T405 + (ML20101T405)
- ML20101T407 + (ML20101T407)
- 1CAN079203, Monthly Operating Rept for June 1992 for Ano,Unit 1 + (ML20101T408)
- ML20101T409 + (ML20101T409)
- ML20101T417 + (ML20101T417)
- ML20101T422 + (ML20101T422)
- ML20101T424 + (ML20101T424)
- ML20101T426 + (ML20101T426)