ML20101T143

From kanterella
Jump to navigation Jump to search
Public Version of Revised Emergency Plan Implementing Procedures,Including Rev 2 to EP-278, Security Team Phone List & Rev 0 to EP-314, Emergency Radiation Exposure Guidelines & Controls. Related Correspondence
ML20101T143
Person / Time
Site: Limerick  
Issue date: 01/03/1985
From:
PECO ENERGY CO., (FORMERLY PHILADELPHIA ELECTRIC
To:
Shared Package
ML20101S937 List:
References
OL, PROC-850103-01, NUDOCS 8502050847
Download: ML20101T143 (19)


Text

_

Psgo 1 of 5 Revision 19 c

12/06/84 LIMERICK GENERATING STATION 3g43jjj33g EMERGENCY PLAN PROCEDURE INDEX PROCEDURE REV.

DATE SIGNED DATE OF LAST NUMBER NO.

TITLE BY SUPER.

PERIODIC REVIEW EP-101 2

Classification of Emergencies 09/27/84 EP-102 5

Unusual Event Response 10/10/84 EP-103 5

Alert Response 10/18/84 EP-104 5

Site Emergency Response 10/18/84 EP-105 5

General Emergency Response 10/05/84 EP-106 1

Written Summary Notification 06/08/84 EP-110 3

Personnel Assembly and Accountability 10/15/84 EP-120 1

Site Emergency Coordinator 06/08/84 EP-201 1

Technical Support Center (TSC) Activation 06/08/84 EP-202 2

Operations Support Center (OSC) Activatini 09/25/84 EP-203 2

Emergency Operations Facility (EOF) Activation 09/27/84 EP-208 3'

Security Team Activation 10/05/84 EP-210 1

Dose Assessment Team 06/08/84 EP-220 CANCELLED EP-221 1

Personnel Dosimetry, Bioassay, f(N4,.M)-

and Respiratory Protection Group 0640k/84 EP-222 2

Field Survey Group a

'4 EP-230 3

Chemistry Sampling and Analysis Team Activat M j(]e]T4'E% 3/20/84 2

EP-231 4

Operation of Post-

%4 "

(,./ q' N.i,

~, -

c f,

Accident Sampling S (PASS)

(08/07Z84

__.a kW EP-232 CANCELLED a

I EP-233 3

Retrieving and Changing

\\'(

Sample Filters and i

Cartridges from the

-Containment Leak Detector During Emergencies 07/20/84 8502050847 850103 PDR ADOCK 05000352 F

PDR

Page 2 of 5 Revision 19 4

12/06/84 LIMERICK GENERATING STATION EMERGENCY-PLAN PROCEDURE INDEX i.

PROCEDURE REV.

DATE SIGNED DATE OF LAST NUMBER NO.

TITLE BY SUPER.

PERIODIC REVIEW EP-234 3

Obtaining Containment l-Gas Samples from the Containment Leak Detector During Emergencies 07/20/84 EP-235 3

Obtaining Reactor Water Samples.from Sample Sinks Following Accident Conditions 07/20/84 l

EP-236 3-Obtaining Cooling Tower i

Blowdown Line Water Samples Following Radioactive Liquid Release after Accident Conditions 08/07/84 EP-237 3

Obtaining the Iodine /

Particulate and/or Gas Samples from the North Vent Wide Range Gas Monitor (WRGM) 07/20/84 EP-238 3

Obtaining Liquid Radwaste Samples from Radwaste Sample Sink Following Accident Conditions 07/20/84 j

EP-240 2

Obtaining Off-Gas Samples from the Air Ejector / Holdup Pipe Discharge Sample Station 06/08/84 i

EP-241 4

Sample Preparation and Handling of Highly Radioactive Liquid Samples 10/04/84 EP-242 3

Sample Preparation and Handling of Highly Radioactive Particulate Filters and Iodine Cartridges 07/20/84 EP-243 4

Sample. Preparation and Handling of Highly Radioactive Gas 08/06/84 l

Samples EP-244 0-Offsite Analysis of High Activity Samples 06/08/84' EP-250 1

Personnel Safety Team i

j Activation 06/08/84 n-

n__,

Page 3 of 5 Revision l19 i-12/06/84 i

LIMERICK GENERATING STATION j

EMERGENCY PLAN PROCEDURE INDEX J

PROCEDURE REV..

DATE SIGNED DATE OF LAST NUMBER NO.

TITLE BY SUPER.

PERIODIC. REVIEW EP-251' l-Plant Survey Group 06/08/84 EP-252 2

Search and Rescue /First.

j Aid 07/20/84 EP-254 1

Vehicle and Evacuee 1

Control Group 06/08/84 I

EP-255 1

Vehicle Decontamination 06/08/84

)

EP-260 1

Fire and Damage

, 06/08/84 l-Team Activation 4

EP-261 1

Damage Repair Group 06/08/84 EP-272 2

Philadelphia Electric 1

Company Officials l

Phone List 10/17/84 EP-273

-2 Limerick Station l

Supervision Call List 10/04/84-EP-275 CANCELLED EP-276 3

Fire and Damage Team Phone List 10/18/84 EP-277 4

Personnel Safety Team Phone List 10/30/84 EP-278 2

Security Team Phone List 12/06/84 EP-279 2

Emergency Operations l

Facility (EOF) Group Phone List 10/05/84 i

EP-280 3

Technical Support l

Center Phone List 10/18/84-EP-282 2

Government and Emergency Management Agencies 10/05/84 l

EP-284 2-Company Consultants j

and Contractors Phone List 09/27/84 EP-287 1

Nearby Public and Industrial Users of I

Downstream Water 06/08/84 EP-291 3

Staffing Augmentation 10/18/84 EP-292 4

Chemistry Sampling and Analysis Team Phone List 10/17/84 l.

Pcgm 4 of~5 Rsvision 19 12/06/84 LIMERICK GENERATING STATION EMERGENCY PLAN PROCEDURE INDEX PROCEDURE REV.

DATE SIGNED DATE OF LAST

]

NUMBER NO.

TITLE BY SUPER.

PERIODIC REVIEW EP-294 3

Dose Assessment Team Phone List 10/18/84 EP-301 0

Operating the Evacuation Alarm and River Warning System 11/11/83 EP-303 2

Local Evacuation 04/02/84 EP-304 2

Partial Plant Evacuation 07/09/84 EP-305 2

Site Evacuation 09/25/84 EP-306 0

Evacuation of the Information Center 12/27/83 EP-307 1

Reception and Orientation of Support Personnel 06/08/84 EP-312 0

Radioactive Liquid Release 11/30/83 EP-313 1

Distribution of Thyroid Blocking Tablets 06/08/84 EP-314 0

Emergency Radiation Exposure Guidelines and Controls 12/06/84 EP-315 1

Calculation of Offsite Doses During a Radiological Emergency Using RMMS in the Manual Mode 11/14/84 EP-316 1

Cumulative Population and Near Real-Time Emergency Dose Calculations for Airborne Releases Manual Method 07/24/84 EP-317 1

Determination of Protective Action Recommendations 10/17/84 EP-318 0

Liquid Release Dose Calculations Method for Drinking Water 11/30/83 EP-319 0

Fish Ingestion Pathway Dose Calculation 11/30/83 EP-325 1

Use of Containment Dose Rates to Estimate Release Source Term 10/17/84

Pcga 5 of 5 RDvision 19 12/06/84 LIMERICK GENERATING STATION EMERGENCY PLAN PROCEDURE INDEX PROCEDURE REV.

DATE SIGNED DATE OF LAST NUMBER NO.

TITLE BY SUPER.

PERIODIC REVIEW EP-330 2

Emergency Response Facility Habitability 07/20/84 EP-401 1

Entry for Emergency Repair and Operations 06/08/84 EP-410 l

_ Recovery Phase Implementation 06/08/84 EP-500 1

Review and Revision of Emergency Plan 06/08/84 O

l r

l l

l

[

e

~.-

l EP-278, Rev. 2

?s-3843111340

" 9"

'6 4

VAW MPG /rgs PHILADELPHIA ELECTRIC COMPANY LIMERICK GENERATING STATION EMERGENCY PLAN IMPLEMENTING PROCEDURE EP-278 SECURITY TEAM PHONE LIST 1.0 PURPOSE The purpose of this procedure is to provide guidelines and information to call in the Security Team.

2.0 RESPONSIBILITIES 2.1 The Security Team Leader shall be responsible to call in team members.

3.0 APPENDICES None 4.0 PREREQUISITES None 5.0 SPECIAL EQUIPMENT y'

  • 'v None s \\..,. ' *

-t

-..q.;:

f-$~Q v

6.0 SYMPTOMS

'a 4

None 7.0 ACTION LEVEL 7.1 This procedure can be used w en the S c'

eam is to be activated or when additional e

to be called in.

s.

$w-3

l EP-278, Rev. 2 Page 2 of 6 VAW/ MPG /rgs

^

8.0 PRECAUTIONS None 9.0 PROCEDURE 9.1 ACTIONS 9.1.1 The (Interim) Security Team Leader shall call people from the following list until an adequate number are able to respond in the appropriate i

groups.

l 9.1.2 Security Team Leader Telephone No.

l (Capt. of M

the Guards) i l

l 6 (Access Lt.)

( W )- M Security Junior Technical Assistant Telephone No.

6 (E)6 i

9.1.3 Security Team Members 9.1.3.1 Security Team Sergeants Telephone No.

ammmmmmme (mm)-a n= =

l

!6

( W )- M M

( W )- M

!.'2llllll:(E-"

1 I

l 1

I l

9.1.3.2 Securfty Team Corporals i

@)-M (m)-m

( M )- M 6

( 6 )- M 6

(W)6

( W )- m M

( W )-

g p: := $'

J' L

e m

h


,.-----.,-,,n-.-

-,.-,,--.-,-.,-.,---n,-


a--e-n---

--,,,,,--e,,

,,,,,,,_.-,,,n,

--,--.,,.w,

l EP-278, Rev. 2 Page 3 of 6 VAW/ MPG /rgs l

9.1.3.3 Security Team CAS and SAS I

( E )- 6 mummmmm.mme cas)-ammusus

)

enuunusumWI (e>-summmer lm!Y l

N (m)-N 6

(-)m l

E!!!=L'""

!S!g m

(m) l l

g

( - )-

l 9.1.3.

Security Team Guards i

I summusum e i

m i

N aman,.

t

\\

M l

-M

mmi:

m.,

m =:

mem=r M

i 6uu - -

"E:l'lm:

== u-i m

i sumupuuummunus i

N i

,,,----w_,----

,-%--,-,.u---_. - - - - - - - - - - - -w-----

---m

I I.

EP-278, Rev. 2 Page 4 of 6 VAW/ MPG /rgs l

9.1.3.,- Security Team Watchmen h_

  • !!!!HilHEL ie

' - mmmmmmmam

'm

_lm 1ET

,I EP-278, Rev. 2 j

Pace 5 of 6 VAW/ MPG /rgs

{.

(

?E l

.: qg.c.n. p. g -

3

?

l 1

W 8

j i

e m.c

~ h.fl::'$ ';b',f... ::

-l_

y

.a ym. e.e

\\

i l

l

- V.w+# -';.;,2. -

I l

&[ f f.J. f '.. W )

l l

%% lQ j

l p;g.f@p app.ty. i cfg I

' 5; ra 2,;-l. a y.'O,

l l

l I

l u,. x m a

- W".,i;.y :..; ~..;'.=

l y ;;.. g ; '.,,.h, f"y'.'."

, ?*

I.'G.Y i.*j -;- t;k ~'_[.9%

hji l

uu, m y

3 pt r a E R M i

.l j

EP-278, Rev. 2 Page 6 of 6 VAW/ MPG /rgs l

9.1.3.6 Watchmen Under Instruction M

\\

l

10.0 REFERENCES

l l

None l

l l

l PROPRIETARY l

EP-314 R3v. 0

, O>

3843111350 Page 1 of 8 WD/jck PHILADELPHIA ELELCTRIC COMPANY LIMERICK GENERATING STATION EMERGENCY PLAN IMPLEMENTING PROCEDURE EF-314 EMERGENCY RADIATION EXPOSURE GUIDELINES AND CONTROLS 1.0 PARTICIPANTS 1.1 The Emergency Director shall ensure that the actions outlined in this procedure are carried out.

1.2 The Personnel Safety Team Leader shall ensure that follow-up items are carried out.

2.0 ACTIONS-IMMEDIATE 2.1 The Emergency Director Shall:

2.1.1 Determine the need to perform specific tasks anticipated to result in exposures exceeding station administrative guidelines by evaluating the potential consequences resulting from not performing the tasks against the anticipated exposure.

2.1.2 Follow the guidelines for emergency exposure listed in EP-314-2.

2.1.3 Verify that the personnel selected to perform the task:

a).

are aware of the potential biological effects associated with the requested Emergency Exposure Guideline.

(See r

Appendix EP-314-4) l b).

are not'(a) fertile female (s).

have not previously received emergency exposure, g.]hNi a'k ).

have been briefed of the situation, are volunteers, and a.,

N e).

are technically qualified to perform

%s the specific task.

l l

4

~. _.

EP-314 Rav. 0 Page 2 of 8 RWD/jek-.

INSTRUCTIONS ASSOCIATED WITH STEPS 2.1.4 THRU 2.1.6

.MAY BE DELEGATED BY THE EMERGENCY DIRECTOR, HOWEVER ONLY THE EMERGENCY DIRECTOR CAN SIGN AUTHORIZATION IN STEP 6 OF SECTION A OF ATTACHMENT EP-314-1.

2.1.4 Instruct personnel not to enter any area where dose rates are unknown and unmeasureable with dose rate instruments.

2.1.5 Ensure that reasonable precautions for minimizing the radiological consequences of the emergency action are taken (i.e.

protective clothing, respiratory protection, thyroid blocking. agent, etc.).

2.1.6 Complete Section A of attachment EP-314-1.

THE EMERGENCY DIRECTOR IS THE ONLY INDIVIDUAL WHO CAN SIGN SECTION A-AUTHORIZING THE EMERGENCY EXPOSURE.

SEE APPENDIX, EP-314-2.

2.2 The individual to receive Emergency Exposure Authorization shall complete Section B of j

Attachment EP-314-1.

l 2.3 The Personnel Safety Team Leader Shall complete Sections C and D of Attachment EP-314-1.

ALTHOUGH IT IS PREFERABLE TO PERFORM AND DOCUMENT THESE STEPS PRIOR TO THE EXPOSURE, THE EMERGENCY DIRECTOR MAY VERBALLY AUTHORIZE THE EXPOSURE AND l

COMPLETE THE DOCUMENTATION AT A LATER TIME.

t 3.0 ACTIONS - FOLLOWUP 3.1 The Personnel Safety Team Leader Shall:

3.1.1 Ensure that the exposure incident is brought i

to the attention of a physican,and/or the exposed individual-is examined by a i

physician based on the guideline in. Appendix EP-314-3.

i 3.1.2 Ensure that the exposure evaluation and a full report on the emergency exposure, including necessary reports in accordance with 10CFR 20.403 are completed.

l

- -. ~,

- ~.

=

EP-314 Rev. O

^

Paga 3 of 8 RWD/jek 4.0 APPENDICES 4.1 EP-314-1 Emergency Exposure Guidelines.

4.2 EP-314-2 Emergency Exposure Guidelines.

4.3 EP-314-3 Physician Attention For Emergency Exposure

. Individuals.

5.0 SUPPORTING INFORMATION 2

5.1:

Purpose - The purpose of this procedure is to provide guidelines and administrative controls for radiation exposures in excess of 10CFR 20 limits

'i during activities involving: life saving and/or reduction of injury, and operation or maintenance of equipment to mitigate an emergency.

5.2 Criteria for Use - This procedure is tc be initiated when emergency response actions to perform-life saving or accident mitigating functions are expected to result in radiation exposures in excess of 10 CFR 20 limits.

10 CFR 20 EXPOSURE LIMIT IS 1.25 REM /QTR.

IF AN i

INDIVIDUAL HAS AN UP-TO-DATE FORM 4 ON FILE, HE MAY r

BE EXPOSED TO A MAXIMUM OF'3 REM /QTR PROVIDED HIS LIFETIME EXPOSURE DOES NOT EXCEED S(N-18) REM.

IF 1

AN INDIVIDUAL DOES NOT EAVE AN UP-TO-DATE FORM 4 ON FILE, THIS PROCEDURE MUST BE USED PRIOR TO THAT 4

INDIVIDUAL EXCEEDING 1.25 REM.

4 5.3 Special Equipment I

None l

5.4 References i

None

,l.

l f

i i

EP-314 Rev. 0 Page 4 of 8 RWD/jek l

ATTACEMENT EP-314-1 EMERGENCY EXPOSURE AUTHORIZATION FORM SECTION A

1. Name (to receive exposure) :

Soc. Sec. No:

Sex Age 2.

Individual TLD Number:

Employee / LGS Department:

3. Task (s) to be Performed:
4. Date of Authorization:

Authorized Limit:

5. Conditions:

Individual is a volunteer Individual is familiar with radiological consequences of exposure.

Fertile females shall not take part.

Individual has not received an emergency exposure before.

Males over forty years of age, if available and capable of performing the task / Dose rates in area are known/measureable.

Life saving Action?

Corrective Action?

6. Emergency Director:

(Signature)

SECTION B I have been briefed in the radiological consequences of the proposed emergency exposure, and I have volunteered to perform the emergency measures during which I will receive the emergency exposure.

7. Signature:

Date:

EP-314 R3v. O Prga 5 of 8 l

RWD/jsk ATTACHMENT EP-314-1 (CONTINUED)

EMERGENCY EXPOSURE AUTHORIZATION FORM SECTION C (Attached exposure evaluation)

1. Dose equivalent assigned for entry:
2. TLD/ Dosimeter Results:
3. Bioassay Results:
4. Medical Evaluation / Action:

Doctor:

5. Personnel Safety Team Leader:

Date SECTION D

1. Disposition (Allow additional exposure, restricted access, etc.):
2. Individual assigned to follow up reports (s):
3. Personnel Safety' Team Leader:

Date:

I i

4

-EP-314 Rav. 0 Pag 216 of 8

.t RWD/jek APPENDIX EP-314-2 Emergency Exposure Guidelines Projected Whole Body Thyroid Authorized Function Dose Dose By

1. Life Saving and

'Redaction of Injury, 75 rem *'

375 rem Emergency **

Director

2. Operation of Equipment to mitigate an Emergency 25 rem
  • Emergency **

Director 1

1

3. Protection of Health and Safety of the 5 rem 25 rem Emergency Public Director
4. Other Emergency 10 CFR20***

10 CRF 20 Emergency Activities limits limits Director

5. Re-entry / Recovery Station Station Activities Administra-Adminin-tive Guide trative lines guide-lines N/A l

l

Reference:

EPA-520/2-75-001 Table 2.1

    • Such exposure shall be on a-voluntry basis
      • 10 CFR 20 Limits: 1.25 Rem /Qtr.

If completed up-to-date l

NRC Form-4 is on file, individual can be exposed to a maximum of 3 rem provided the individual does not exceed 5(N-18) rem. N is the individual's age in years.

[

i l

l i

{

\\

l

Page 7 of 8 RWD/jek APPENDIX EP314-3 1

PHYSICIAN ATTENTION FOR-EMERGENCY

' EXPOSURE INDIVIDUALS 4

The following criteria should be applied as a minimum to any individual potentially exposed to excessive. radiation levels:-

i -

a) If an individual's dose equivalent exceeds 10 rem for the whole body, 30 rem for the thyroid, 60 rem for the skin, and/or 150 rem to an extremity, the details of the exposure incident shall be brought to the attention of a physician.

The physician shall determine the need, extent, and nature of any clinical, biological, or biochemical examinations.

b) If an individual's dose equivalent exceeds 25 rem for the I

whole body, 75 rem to the thyroid.- 150 rem for the skin, and/or 375 rem for an extremity, the individual shall be examined by a physician.

The Physician shall determine the need,Jextent, and nature of any clinical, biological, or biochemical examinations'or necessary medical surveilence..

l' b

EP-314 Rav. 0

-4'.

Page 8 of 8 RWD/jek APPENDIX EP-314-4

)

i POTENTIAL BIOLOGICAL EFFECTS ASSOCIATED WITH EMERGENCY EXPOSED GUIDELINES Projected Biological Whole Body Effects Long Term Dose Summary Risks 4.5 Rem No Detectable

.0135% (or 13.5 ill effects additional cases) in 10,000 of contacting Cancer.

(See Note 1)

(See Note 2) 25 Rem Slight transient 0.75% (or 75 reduction in additional cases) white blood in 10,000 of cells.

May contacting experience cancer one or more (See Note 1) of the following:

nausea anorexia vomiting fatigue 75 Rem 2.25% (or 225 additional cases) in 10,000 of con-tacting Cancer.

(See Note 1)

Note 1: The normal incidence of Cancer is approximately 2500 in 10,000 (or 25%).

The long term risks indicate potential increases above the normqJ incidence, if 10,000 people received the projected whole body dose.

Note 2: The acute effects are similar over the range from 25 Rem to 75 Rem, but are more likely to be experienced as exposures increase.

/

_