- ML20096F241 + (ML20096F241)
- ML20096F243 + (ML20096F243)
- ML20096F244 + (ML20096F244)
- 05000413/LER-1984-004-03, :on 840726-30,daily Surveillance of Unit Vent Flow Rate Monitor Channel Check Not Performed.Caused by Personnel/Administrative Error.Procedure Revised & Personnel Counseled + (ML20096F249)
- ML20096F250 + (ML20096F250)
- ML20096F251 + (ML20096F251)
- ML20096F252 + (ML20096F252)
- AECM-84-0407, Special Rept 84-029/0:on 840709,Div 1 Diesel Generator Tripped on Turbocharger Low Oil Pressure During 18-month Surveillance.Caused by High Lube Oil Filter Differential Pressure.Filter Replaced + (ML20096F253)
- 05000374/LER-1992-004-07, :on 920415,reactor Manually Scrammed as Conservative Measure Due to Main Turbine Control Valve Cycling.Cause Not Determined.Excessive Bypass Valve Cycling Initiated Scram.Speed Circuits Monitored + (ML20096F257)
- ML20096F258 + (ML20096F258)
- 05000296/LER-1984-007-01, :on 840616,diesel Generator 3B Inadvertently Started During Performance of Maint Instruction 37.Caused by Two Relays Shorting Together.Caused by Personnel Error & Procedural Deficiency.Procedure Revised + (ML20096F259)
- ML20096F260 + (ML20096F260)
- ML20096F262 + (ML20096F262)
- 05000259/LER-1984-027, :on 840627,main Steam Relief Valve Lifted & Leaked.Unit Manually Scrammed & Valve Replaced.Testing of Valve Revealed No Electrical/Mechanical Anomalies.No Further Action Necessary + (ML20096F263)
- ML20096F264 + (ML20096F264)
- ML20096F265 + (ML20096F265)
- ML20096F270 + (ML20096F270)
- 05000362/LER-1984-034-01, :on 840824,3.5 Ft of Conduit Fire Wrapping for Auxiliary Feedwater Pump Power & Control Cables Found Missing.Caused by Clerical Error.Hourly Fire Watch Initiated Until Conduit Wrapped + (ML20096F271)
- ML20096F272 + (ML20096F272)
- ML20096F273 + (ML20096F273)
- ML20096F274 + (ML20096F274)
- ML20096F275 + (ML20096F275)
- ML20096F276 + (ML20096F276)
- ML20096F278 + (ML20096F278)
- ML20096F279 + (ML20096F279)
- ML20096F281 + (ML20096F281)
- ML20096F284 + (ML20096F284)
- ML20096F285 + (ML20096F285)
- ML20096F286 + (ML20096F286)
- ML20096F289 + (ML20096F289)
- ML20096F291 + (ML20096F291)
- ML20096F292 + (ML20096F292)
- ML20096F295 + (ML20096F295)
- ST-HL-AE-4100, Advises That Investigation of Items 6.a & 6.b from Insp Repts 50-498/91-21 & 50-499/91-21 Completed & Files Available for NRC Review + (ML20096F296)
- ML20096F297 + (ML20096F297)
- ML20096F298 + (ML20096F298)
- ML20096F299 + (ML20096F299)
- ML20096F300 + (ML20096F300)
- ML20096F301 + (ML20096F301)
- ML20096F302 + (ML20096F302)
- 05000425/LER-1992-005-02, :on 920421,plant Vent Radiation Monitor Deenergized When ESFAS Testing Initiated.On 920422,noted That Grab Samples Not Taken for Noble Gases.Caused by Personnel Error.Foreman Counseled + (ML20096F303)
- ML20096F305 + (ML20096F305)
- ML20096F308 + (ML20096F308)
- ML20096F313 + (ML20096F313)
- ML20096F314 + (ML20096F314)
- ML20096F322 + (ML20096F322)
- ML20096F324 + (ML20096F324)
- ML20096F325 + (ML20096F325)
- ML20096F326 + (ML20096F326)
- ML20096F328 + (ML20096F328)
- ML20096F330 + (ML20096F330)