- 05000277/LER-1995-004-02, :on 950814,TS Violation Occurred When RWCU Temp Switch Was Inoperable Due to Design Deficiency.Revised Calibr Sheet for TIS-2-12-099 to Add Note to Ensure Proper Installation of Thermistor + (ML20092F851)
- 05000412/LER-1995-006, :on 950813,RT Occurred Due to Main Generator Loss of Field.Voltage Regulator Inspected.Current Limiting Resistors Were Satisfactory & Ctr Tap Clamps Were Removed + (ML20092F858)
- ML20092F862 + (ML20092F862)
- ML20092F874 + (ML20092F874)
- ML20092F875 + (ML20092F875)
- ML20092F876 + (ML20092F876)
- ML20092F881 + (ML20092F881)
- NRC-95-0087, Requests Reduced NRC Insp Activity in Svc Water Sys Operational Performance Insp Area of Emphasis + (ML20092F885)
- ML20092F887 + (ML20092F887)
- ML20092F888 + (ML20092F888)
- ULNRC-03267, Forwards Addl Info Re 941209 Application for Amend to License NPF-42,revising TS 4.3.2.2 & 4.7.1.2.1 & Bases for TS 3/4.7.1.2 for Auxiliary Feedwater Sys,Per Telcon + (ML20092F895)
- ML20092F899 + (ML20092F899)
- ML20092F903 + (ML20092F903)
- ML20092F904 + (ML20092F904)
- ML20092F910 + (ML20092F910)
- ML20092F914 + (ML20092F914)
- ML20092F916 + (ML20092F916)
- ML20092F917 + (ML20092F917)
- ML20092F924 + (ML20092F924)
- ML20092F927 + (ML20092F927)
- ML20092F937 + (ML20092F937)
- ML20092F942 + (ML20092F942)
- ML20092F949 + (ML20092F949)
- ML20092F956 + (ML20092F956)
- ML20092F968 + (ML20092F968)
- ML20092F969 + (ML20092F969)
- ML20092F972 + (ML20092F972)
- 05000265/LER-1994-008, Informs of Commitments Being Made Re LER 94-008,rev 0 + (ML20092F973)
- ML20092G011 + (ML20092G011)
- ML20092G017 + (ML20092G017)
- ML20092G036 + (ML20092G036)
- 05000370/LER-1995-003-04, :on 950815,containment Integrity Was Lost Momentarily Due to Degraded Subcomponent.Developed Interim Measures for Personnel Airlock Door Operation Until Door Alignment Corrected + (ML20092G037)
- ML20092G050 + (ML20092G050)
- 05000456/LER-1995-008-05, :on 950818,ECCS Equipment Room Differential Pressure Was Not Maintained Due to Mgt Deficiency & Personnel Error.Revised Barrier Impairment Procedure to Be More Descriptive + (ML20092G051)
- ML20092G057 + (ML20092G057)
- LIC-95-0167, Application for Amend to License DPR-40,revising TS 2.7 Extending Allowed Outage Time from 7 Days Per Month to 7 Days W/Addl Once Per Cycle 10 Day Allowed Outage Time + (ML20092G063)
- ML20092G066 + (ML20092G066)