- 05000328/LER-1984-006, :on 840406,high Radiation Alarm Actuated Causing Containment Ventilation Isolation.Caused by Electromagnetic Interference & Personnel Error.Spurious Radiation Alarm Reset + (ML20084G357)
- 05000327/LER-1984-023, :on 840402,alarm Indicating Lights on Bistables of PORV Appeared Reversed for Correct Bistable Action.Caused by PORV Modified to Inoperable State.Porv Rewired & Instruction Revised + (ML20084G360)
- ML20084G361 + (ML20084G361)
- ML20084G372 + (ML20084G372)
- ML20084G393 + (ML20084G393)
- ML20084G396 + (ML20084G396)
- ML20084G401 + (ML20084G401)
- ML20084G416 + (ML20084G416)
- ML20084G466 + (ML20084G466)
- ML20084G467 + (ML20084G467)
- ML20084G475 + (ML20084G475)
- RBG-17-686, Interim Deficiency Rept DR-129 Re Agastat Relays w/CR0095 Bases.Next Rept Will Be Submitted by 840516 + (ML20084G477)
- ML20084G479 + (ML20084G479)
- ML20084G482 + (ML20084G482)
- ML20084G483 + (ML20084G483)
- ML20084G485 + (ML20084G485)
- ML20084G488 + (ML20084G488)
- ML20084G505 + (ML20084G505)
- W3P84-0863, Responds to Concern Resulting from Emergency Preparedness Appraisal on 840130-0210 Re Accountability of Onsite Personnel Following Evacuation.Necessary Procedures & Hardware Will Be in Place Prior to Fuel Load + (ML20084G522)
- AECM-84-0047, Responds to NRC Re Violations Noted in IE Insp Rept 50-416/83-51.Util Denies Alleged Violation.Addl Guidance Added to Operating Procedures to Ensure Proper Control Maintained When Bypassing Control Rods + (ML20084G524)
- ML20084G527 + (ML20084G527)
- ML20084G536 + (ML20084G536)
- ML20084G539 + (ML20084G539)
- ML20084G548 + (ML20084G548)
- 05000219/LER-1984-002-01, :on 840302,unit Substation Circuit Breaker to Motor Control Ctr 1B32 Failed to Trip When Undervoltage Device Deenergized.Circuit Breakers to Shut Down Cooling Pump Failed to Trip.Shaft Bearings Cleaned + (ML20084G551)
- ML20084G562 + (ML20084G562)
- ML20084G563 + (ML20084G563)
- ML20084G569 + (ML20084G569)
- ML20084G578 + (ML20084G578)
- 05000272/LER-1984-010, :on 840401,discovered Disks Separated from Stems on 11 RTD Bypass Line Valves on 830129.Caused by Force Exerted on Joint When Valve Backseated + (ML20084G583)
- ML20084G590 + (ML20084G590)
- ML20084G591 + (ML20084G591)
- ML20084G594 + (ML20084G594)
- ML20084G604 + (ML20084G604)
- ML20084G606 + (ML20084G606)
- ML20084G609 + (ML20084G609)
- ML20084G610 + (ML20084G610)
- PLA-2180, Final Part 21/deficiency Rept Re Improper Relief Valve Settings,Design Pressures & Temps.Initially Reported on 831118.Calculations Performed Assure Lines Adequate for Intended Svc + (ML20084G615)
- ML20084G618 + (ML20084G618)
- ML20084G631 + (ML20084G631)
- ML20084G633 + (ML20084G633)
- ML20084G636 + (ML20084G636)
- ML20084G641 + (ML20084G641)
- ML20084G649 + (ML20084G649)
- ML20084G653 + (ML20084G653)
- ML20084G657 + (ML20084G657)
- ML20084G660 + (ML20084G660)
- ML20084G663 + (ML20084G663)
- ML20084G666 + (ML20084G666)
- ML20084G682 + (ML20084G682)
- ML20084G723 + (ML20084G723)