__
(v1
.?-
fc.) $f Commonwealth Edison Company 72 WEST ADAMS STREET
- C H I C A G O.
BLLINOIS l
Addr.se E. ply ser POST OfflCE tox 747
- CHICAGO, IL L f N OIS 4069 0 Dresden Nuclear Power Station i
R. R. #1 Morris, Illinois 60450
/~
S e
January 4, 1973 o fn-
~,h i
Ilf. Jr.
LJ e
l-- JAW 8 197F:,
Mr. A. Giambusso Deputy Director for Reactor Projects 9
p
- ggm g
Direc_torate of Licensing
\\f,
f g'
,d U. S. Atomic Energy Commission Washington, D. C.
20545
/plr
SUBJECT:
LICENSE DPR-19, DPESDEN NUCLEAR POWER STATION, UNIT #24 SECTION 5.6.B.3 CP THE TECH!;ICAL SPECIFICATIONS.
t
Reference:
Letter to Edward J. Bloch from W. P. Worden dated June 6,1972.
(l/{bf-())
I
Dear Mr. Giambusso:
1
[jf Af ter the failure of snap-lock limit switch SL4C-64L on May 27, p
1972, (Reference) an investigation was initiated to determine the cause h JI of the failure.
[I i
On corresponding with the vendor, National Acme Company, they
<J(
assured us that the snap-lock switches are the most reliable switelfes?
J '
available.
\\p L The vendor recommended the following to avoid the possibility of a similar type of failure 1.
Check snap-lock switches with slow lever arm movement for i
similar type of failure.
2.
Tag all National Acme snap-lock switches with a caution note to read:
Caution - when assembling liner onto shaf t, lever must be held stationary so that shaft does not rotate as pipe plug is tightened.
1
~
The above mentioned items have been completed on both Units 2 and 3, and are expected to minimize the potential for similar failures in the future.
.f 6
., Sincerely, f
ynrn em ri qmf[
~ _ _ _ _.,
(
21G
.J 83042200y7 739g94 DR ADOCK 05000237
\\'
i PDR W. P. Worden f9hth ctvrsdbww.v! bra