Search by property
Jump to navigation
Jump to search
This page provides a simple browsing interface for finding entities described by a property and a named value. Other available search interfaces include the page property search, and the ask query builder.
List of results
- 05000277/LER-1991-030, :on 910827,two Diesel Generators Discovered Inoperable Concurrently as Result of Generator Rectifier Ground.Cause Unknown.Appropriate Operating Procedures Reviewed & Revised + (ML20083D704)
- ML20083D706 + (ML20083D706)
- U-601883, Requests Withdrawal of 910906 Request for Regional Waiver of Compliance to Provide Addl Time to Effect Repairs in Response to Microbiologically Induced Corrosion in Jacket Water Heat Exchanger for 12-cylinder Engine of Standby EDG + (ML20083D709)
- ML20083D712 + (ML20083D712)
- ML20083D713 + (ML20083D713)
- ML20083D714 + (ML20083D714)
- 3F1283-13, Notifies of Revised Schedule to Install New Emergency Data Aquisition Sys Per Response to Suppl 1 to NUREG-0737,Item III.A.2.2.Sys Installation Will Be Completed on 840601. Testing & Training Will Be Completed 840702 + (ML20083D722)
- ML20083D723 + (ML20083D723)
- ML20083D726 + (ML20083D726)
- RBG-16-573, Interim Deficiency Rept DR-129 Re Agastat Relays w/CR0095 Bases.Investigation Incomplete.Next Rept by 840228 + (ML20083D727)
- ML20083D729 + (ML20083D729)
- ML20083D730 + (ML20083D730)
- ML20083D733 + (ML20083D733)
- ML20083D736 + (ML20083D736)
- ML20083D745 + (ML20083D745)
- ML20083D747 + (ML20083D747)
- AECM-83-0798, RO 83-111/0:on 830328,fire Penetration CE-519D Opened to Implement Design Change Package.Penetration Reopened to Install Conduits Per Package.Fire Watch Established & Will Continue Until Penetration Sealed + (ML20083D750)
- ML20083D754 + (ML20083D754)
- AECM-83-0784, RO 83-108/0:on 831111 & 17,fluctuating Temps in Upper Control Room Exceeded Tech Spec Limit of 77 F for More than 8 H.Max Recorded Temp Was 79 F.Equipment Operability Unaffected + (ML20083D756)
- ML20083D758 + (ML20083D758)
- ML20083D762 + (ML20083D762)
- ML20083D765 + (ML20083D765)
- 05000298/LER-1991-008, :on 910826,valve RHR-MO-M057 Exceeded TS Closure Time During Surveillance Testing.On 910917,valve Not Deactivated During Period of Inoperability.Caused by Personnel Failure.Personnel Counseled + (ML20083D770)
- ML20083D771 + (ML20083D771)
- ML20083D772 + (ML20083D772)
- ML20083D774 + (ML20083D774)
- 05000370/LER-1983-073-03, /03L-0:on 831026,main Steam PORVs 2SV-1,7,13 & 19 Did Not Receive Close Signal from Solid State Protection Sys Train A.Caused by Disconnected Wire.Wire Reconnected + (ML20083D776)
- 05000250/LER-1983-022-03, /03L-0:on 831002,during Scheduled Refueling Shutdown Operations,Motor Operated Valves 843A,843B & 869 Not Verified Closed W/Breakers Racked Out.Caused by Not Adhering to Procedures + (ML20083D782)
- ML20083D784 + (ML20083D784)
- ML20083D785 + (ML20083D785)
- 05000327/LER-1983-174-03, /03L-0:on 831121,ESF for Steam Line Pressure Function Failed to Meet Surveillance Requirements & Declared Inoperable.Caused by Dirty Contacts on Universal Logic Card A206 + (ML20083D788)
- 05000482/LER-1991-011, :on on 910718,determined That Quarterly CCW Inservice Valve Test Not Completely Performed on 910514. Caused by Status Sheet Incorrectly Initialed to Signify Test Completed.Individual Counseled + (ML20083D794)
- ML20083D797 + (ML20083D797)
- ML20083D800 + (ML20083D800)
- ML20083D802 + (ML20083D802)
- ML20083D813 + (ML20083D813)
- 05000296/LER-1983-059-01, /01T-0:on 831208,during Refueling outage,crack- Like Indication Detected.Caused by Intergranular Stress Corrosion Cracking on Weld DSHS-3-2.Head Spray Piping Will Be Removed Before Startup + (ML20083D814)
- ML20083D816 + (ML20083D816)
- RBG-35-679, Forwards Results of UT Conducted on N4A-2 Feedwater Nozzle to safe-end Weld During mid-cycle Outage of Fourth Fuel Cycle.Circumferential Indication in Buttered Area of Safe End Side of Weld Noted During Second Refueling Outage + (ML20083D819)
- 05000321/LER-1983-112-03, /03L-0:on 831117,two Vacuum Breakers Would Not Open & Close Properly.Caused by Inadequate Design of Vacuum Breaker Hinge Pin.Safety Relief Valve Discharge Line Vacuum Breakers Replaced + (ML20083D821)
- ML20083D822 + (ML20083D822)
- ML20083D827 + (ML20083D827)
- TXX-9128, Supplemental Deficiency Rept CP-85-054 Re Discrepancies in Seismic Qualification Documents for HVAC Supports.Design Basis Document Established to Ensure That Seismic Qualification Requirements Maintained + (ML20083D834)
- ML20083D835 + (ML20083D835)
- ML20083D840 + (ML20083D840)
- RBG-16-594, Forwards Description of ASME III Subsection Nf Support Program Per 831213 Telcon.Info Will Be Included in Future FSAR Amend + (ML20083D842)
- ML20083D844 + (ML20083D844)
- 05000456/LER-1991-009-04, :on 910805,gas Decay Tank Sample Not Obtained. Caused by Procedure Deficiency.Alarm Response & Operating Procedures Will Be Revised to Provide More Guidance.W/ + (ML20083D845)
- 05000280/LER-1983-052-03, /03L-0:on 831118,both Charging Pump Component Cooling Water Intermediate Seal Coolers Isolated.Caused by Inadvertent Isolation of Cooler A.Component Cooling Water to Coolers Unisolated + (ML20083D851)
- ML20083D855 + (ML20083D855)
- ML20083D856 + (ML20083D856)