- 05000374/LER-1986-007-01, :on 860216,excessive static-o-ring Pressure Switch Drift Occurred.Caused by Rough Surface Finish on Piston in Pressure Switch,Which Caused Erratic Movement.All Relief Valve Setpoint Switches Recalibrated + (ML20083D626)
- ML20083D627 + (ML20083D627)
- 05000374/LER-1991-006, :on 910321,primary Containment Integrity Declared Inoperable During Surveillance Testing.Caused by Procedural Deficiency.Operator Determined Cause of Dual Indication & Valves Closed + (ML20083D628)
- ML20083D635 + (ML20083D635)
- ML20083D638 + (ML20083D638)
- ML20083D645 + (ML20083D645)
- ML20083D647 + (ML20083D647)
- HL-1845, Responds to NRC Re Violations Noted in Insp Rept 50-321/91-20 & 50-366/91-20.Corrective Actions:Design Change Request Implemented to Provide Alternate Power Supply for Controls for Air Conditioning Unit C + (ML20083D648)
- 05000281/LER-1983-055-03, /03L-0:on 831118,motor Driven Auxiliary Feed Pump B 2-FW-P-3B Unable to Develop Flow & Declared Inoperable. Caused by Leaking Check Valves Allowing Hot Water to Seep Into Pump Casing & Bind Pumps + (ML20083D650)
- 05000369/LER-1991-012-01, :on 910823,vital Battery Surveillance Missed. Caused by Inappropriate Actions.Planning & Personnel Will Evaluate Changing Day of Wk Surveillance Performed to Ensure Appropriate Interaction + (ML20083D651)
- ML20083D652 + (ML20083D652)
- 05000313/LER-1991-008-03, :on 910827,several Instrument Modules Noted W/O Vibration Dampening Matl or Module Guide Rails Installed on Foxboro Spec 200 Cabinets.Caused by Obsure Vendor Info. Training Module Will Be Developed + (ML20083D653)
- ML20083D654 + (ML20083D654)
- ML20083D656 + (ML20083D656)
- ML20083D657 + (ML20083D657)
- ML20083D660 + (ML20083D660)
- ML20083D662 + (ML20083D662)
- ML20083D663 + (ML20083D663)
- 05000395/LER-1983-131-03, /03L-0:on 831124,pressurizer Pressure Trip Bistable PB-455D Began Alternately Tripping & Resetting. Caused by Electronic Component Failure.Defective Circuit Board Replaced & Channel Returned to Svc + (ML20083D665)
- ML20083D667 + (ML20083D667)
- ML20083D668 + (ML20083D668)
- ML20083D669 + (ML20083D669)
- 05000321/LER-1983-104-03, /03L-0:on 831118,while Performing Hydraulic Shock & Sway Arrestor Insp & Functional Test,Snubber 1B31-SS-A7 Discovered W/Low Reservoir Fluid Level.Caused by Inadequate Fluid Reserve Due to Leakage.Snubber Rebuilt + (ML20083D672)
- ML20083D676 + (ML20083D676)
- A830026, Withdraws 830930 Request to Establish Six Crew Rotating Shift Providing Addl Crew Time for Training.Five Shift Basis Will Continue,Per 10CFR50.54(m)(2)(i),due to Operator Attrition & Poor Performances on Licensing Exams + (ML20083D677)
- ML20083D678 + (ML20083D678)
- 05000339/LER-1991-008-03, :on 910905,discovered That Five Fuses,Which Provide Secondary Protection for Pressurizer Heater Electrical Penetrations,Failed to Meet Acceptance Criteria on 910829.Fuses Replaced & Records Reviewed + (ML20083D679)
- ML20083D680 + (ML20083D680)
- ML20083D681 + (ML20083D681)
- 05000389/LER-1983-073-03, /03L-0:on 831114,while in Mode 1,outer Door on Escape Airlock Opened.Caused by Personnel Misunderstanding. Personnel Involved Counseled as to Importance of Adhering to Tech Spec Requirements + (ML20083D682)
- ML20083D683 + (ML20083D683)
- ML20083D684 + (ML20083D684)
- ML20083D685 + (ML20083D685)
- 05000395/LER-1983-130-03, /03L-0:on 831124,containment Bldg Internal Pressure Was Negative 1.2 Psig.Caused by Personnel Error & Inadequate Procedure.Exhaust Fan Secured & Supply Fan Started.Operating Procedure Revised + (ML20083D686)
- ML20083D688 + (ML20083D688)
- ML20083D689 + (ML20083D689)
- ML20083D692 + (ML20083D692)
- 05000278/LER-1991-013-03, :on 910825,high Pressure Coolant Injection Sys Discovered Inoperable.Caused by Room Cooler Fan Trip on Thermal Overloads.Operator Immediately Reset Thermal Overloads + (ML20083D693)
- BECO-83-299, Forwards Detailed Description of ALARA Program to Be Emplaced Should Recirculation Sys Piping Replacement or Repair Be Necessary.Alara Program Controls Include Formation of Dedicated Group W/Job Shutdown Authority + (ML20083D694)
- PY-CEI-NRR-1381, Application for Amend to License NPF-48,changing Tech Spec 3.1.3.3, Control Rod Scram Accumulators to Allow Alternate Method for Determining Whether CRD Pump Operating + (ML20083D695)
- ML20083D696 + (ML20083D696)
- ML20083D698 + (ML20083D698)
- ML20083D699 + (ML20083D699)
- ML20083D703 + (ML20083D703)
- 05000277/LER-1991-030, :on 910827,two Diesel Generators Discovered Inoperable Concurrently as Result of Generator Rectifier Ground.Cause Unknown.Appropriate Operating Procedures Reviewed & Revised + (ML20083D704)
- ML20083D706 + (ML20083D706)
- U-601883, Requests Withdrawal of 910906 Request for Regional Waiver of Compliance to Provide Addl Time to Effect Repairs in Response to Microbiologically Induced Corrosion in Jacket Water Heat Exchanger for 12-cylinder Engine of Standby EDG + (ML20083D709)
- ML20083D712 + (ML20083D712)
- ML20083D713 + (ML20083D713)
- ML20083D714 + (ML20083D714)
- 3F1283-13, Notifies of Revised Schedule to Install New Emergency Data Aquisition Sys Per Response to Suppl 1 to NUREG-0737,Item III.A.2.2.Sys Installation Will Be Completed on 840601. Testing & Training Will Be Completed 840702 + (ML20083D722)