ML20083D698

From kanterella
Jump to navigation Jump to search
Proposed Tech Spec 3.1.3.3 Re Control Rod Scram Accumulators
ML20083D698
Person / Time
Site: Perry FirstEnergy icon.png
Issue date: 09/23/1991
From:
CENTERIOR ENERGY
To:
Shared Package
ML20083D697 List:
References
NUDOCS 9110010155
Download: ML20083D698 (1)


Text

--

PY-CE!/NRR-1381 L j

Page I of I REACTIVITY CONTROL SYSTEMS CONTROL ROD SCRAM ACCUMULATORS LIMITING CONDITION FOR OPERATION 3.1.3.3 All control rod scram accumulators shall be OPERABLE.

APPLICABILIE: OPERATIONAL CONDITIONS 1, 2 and 5*.

ACTION:

a.

In OPERATIONAL CONDITIONS 1 or 2:

1.

With one control rod scrae accumulator inoperable, withh 8 hour9.259259e-5 days <br />0.00222 hours <br />1.322751e-5 weeks <br />3.044e-6 months <br />s:

a)

Restore the inoperable accumulator to OPERABLE status, or b)

Declare the control rod associated with the inoperable accumulator inoperable.

Otherwise, be in at least HOT SHUTDOWN within the next 12 hours1.388889e-4 days <br />0.00333 hours <br />1.984127e-5 weeks <br />4.566e-6 months <br />.

2.

With more than one control rod scras accumulator inoperable, declare the associated control rods inoperable and:

a)

If the control rod associated with any inoperable scras accumulator is withdrawn, immediately verify that at least one control rod drive pump is operating by inserting at least one withdrawn control rod at least one notchQIf no m e

rod drive pump is operating:

contrr;l I6d % r

'ri Mer (1) If reactor pressure is > 900 psig, YErtDiaS

  • 1 N!g.

one control rod drive p~ ump within 20 minutes or place the reactor mode switch in the Shutdown position.

(2) If reactor pressurn is < 900 psig, place the reactor mode switch in the Shutdown position.

b)

Insert the inoperable control rods and disars the associated directional control valves either:

1)

Electrically, or 2)

Hydraulically by closing the drive water and exhaust water isolation valves.

Otherwise, be in at 'least HOT SHUTDOWN within 12 hours1.388889e-4 days <br />0.00333 hours <br />1.984127e-5 weeks <br />4.566e-6 months <br />.

b.

In OPERATIONAL CONDITION 5*:

er 1.

With one withdrawn control rod with its associated scram accumu-mo lator inoperabla, insert the affected control rod and disare the SP associated directional control valves within one hour, either:

oo gg a)

Electrically, or b)

Hydraulically by r. losing the drive water and exhaust water vuQ isolation valves.

30 O

Not o

U$

applicable to control rods removed per Specification 3.9.10.1 ar 3.9.10.2.

oA h.

PtRRY - UNIT 1 3/4 1-8

_ - __ _ _ _ _ _ _ _