List of results
- 05000373/LER-1991-012-03, :on 910729,RCIC Turbine Tripped on Mechanical Overspeed Due to Governor Valve Sticking Open.Work Requests L09337 & L09338 Initiated to Investigate & Repair Problem. Valve Replaced + (ML20082J111)
- 05000373/LER-1991-013-03, :on 910807,actuation of B Ve Charcoal Absorber Occurred.Caused by Defective Ionization Detector. Defective Ionization Detector Replaced & Charcoal Adsorber Realigned + (ML20082J114)
- PY-CEI-NRR-1940, Monthly Operating Rept for Mar 1995 for Perry Nuclear Power Plant,Unit 1 + (ML20082J117)
- ML20082J118 + (ML20082J118)
- NRC-91-0106, Withdraws Commitment to Replace Vent Line Isolation Valves on Scram Discharge Vol + (ML20082J123)
- ML20082J126 + (ML20082J126)
- ULNRC-03192, Monthly Operating Rept for Mar 1995 for Callaway Plant Unit 1 + (ML20082J129)
- 3F0891-06, Application for Amend to License DPR-72,consisting of Tech Spec Change Request 189,Rev 0,amending Definition of Channel Calibration to Address Alternate Techniques for Instrument Channels W/Resistance Temp Detectors & Thermocouple Sensors + (ML20082J133)
- NRC-95-0037, Monthly Operating Rept for Mar 1995 for Fermi 2 + (ML20082J135)
- ML20082J138 + (ML20082J138)
- RBG-35476, Provides Response to Generic Ltr 89-10,suppl 2,request for Addl Info Re Consideration of Results of NRC-sponsored Tests of motor-operated Valves + (ML20082J140)
- ML20082J143 + (ML20082J143)
- LIC-95-0081, Responds to Violations Noted in Insp Rept 50-285/95-03. Corrective Actions:Security Dept Organization & Procedures Should Prevent Event from Recurring + (ML20082J150)
- ML20082J152 + (ML20082J152)
- ELV-03043, Responds to NRC 910815 Discussion Re Inconsistent LCO Value Noted in Review of 910808 Application for Amend to Licenses NPF-68 & NPF-81,revising RCS Flow Measurement Uncertainity & LCO Value of RCS Flow + (ML20082J154)
- ML20082J155 + (ML20082J155)
- ML20082J159 + (ML20082J159)
- RBG-41408, Responds to Violations Noted in Insp Rept 50-458/95-01. Corrective Actions:Field Observations Will Be Conducted by Maint Planners to Critique Performance of Sample of Work Packages + (ML20082J163)
- ML20082J165 + (ML20082J165)
- 05000327/LER-1991-020, :on 910722,LCOs 3.7.11.2 & 3.7.11.4 Entered When Fire Protection Spray,Sprinkler Sys & Hose Stations Discovered Inoperable.Caused by Personnel Error.Operations Review Team Evaluating Event + (ML20082J169)
- ML20082J176 + (ML20082J176)
- ML20082J177 + (ML20082J177)
- ML20082J178 + (ML20082J178)
- ML20082J181 + (ML20082J181)
- 05000298/LER-1991-007, :on 910730,fan Coil Units Declared Inoperable. Caused by Inadequacies in Original Design.All Safety Related Fan Coil Units Verified to Be Correctly Supported + (ML20082J188)
- ML20082J199 + (ML20082J199)
- ST-HL-AE-5003, Potential Slight Degradation of Decay Heat Removal Capacity Via Natural Circulation + (ML20082J203)
- ML20082J205 + (ML20082J205)
- ML20082J215 + (ML20082J215)
- 05000499/LER-1995-001-01, :on 950119,potential Slight Degradation of Decay Heat Removal Capacity Via Natural Circulation Occurred.Caused by Failure to Fully Evaluate Thermodymanic TS Bases for Using Sg.Operators Briefed + (ML20082J221)
- LIC-95-0079, Responds to Questions in NRC 950302 RAI & Addl Questions Raised by NRC During 950323 Telcon,To Assist Closure of NRR Review of Plant Revised Evaluation of Control Habitability + (ML20082J225)
- ML20082J237 + (ML20082J237)
- ML20082J249 + (ML20082J249)
- ML20082J260 + (ML20082J260)
- ML20082J265 + (ML20082J265)
- ML20082J266 + (ML20082J266)
- ML20082J276 + (ML20082J276)
- LIC-95-0084, Informs That Util Completed eddy-current Testing of SG Tubes at Plant on 950317,during Fifteenth Refueling Outage + (ML20082J278)
- 05000373/LER-1983-127-03, /03L-0:on 831031,rod Block Monitor Channel a Generated Erratic & False Meter Indications for Local Power Range Monitor a & C Levels.Caused by Oscillations from Failed Capacitor.Capacitor Module Replaced + (ML20082J289)
- 05000373/LER-1983-125-03, /03L-0:on 831021,during Control Rod Movements,Rod Block Monitor Channel a Declared Inoperable & Rod Block Alarms Sounded When Control Rod Selected.Caused by Failed Logic Card.Card Replaced + (ML20082J291)
- ML20082J294 + (ML20082J294)
- ML20082J296 + (ML20082J296)
- 05000373/LER-1983-130-03, /03L-0:on 831021,stack wide-range Gas Monitor Alarm Received.Caused by Checksource Not Remaining Long Enough at Detector Window for Detector to respond.Mid-range Detector Manually Source Checked + (ML20082J298)
- ML20082J303 + (ML20082J303)
- ML20082J307 + (ML20082J307)
- ML20082J309 + (ML20082J309)
- 05000306/LER-1983-026-03, /03L-0:on 831021,sodium Hydroxide Concentration of 11.5% in Spray Additive Tank Exceeded Tech Spec Limit of 11%.Caused by Inadequate Mixing for Design Change.Tank Refilled.Solution Diluted & Recirculated + (ML20082J316)
- ML20082J317 + (ML20082J317)
- 05000373/LER-1983-131-03, /03L-0:on 831019,reactor Recirculation Sys Jet Pumps Did Not Meet Tech Spec Operability Criteria.Caused by Use of Data Obtained from Test Condition 3 Rather than Test Condition 6.Pumps Retested W/Proper Data + (ML20082J318)
- ML20082J323 + (ML20082J323)
- ML20082J325 + (ML20082J325)