Search by property
Jump to navigation
Jump to search
This page provides a simple browsing interface for finding entities described by a property and a named value. Other available search interfaces include the page property search, and the ask query builder.
List of results
- ML20079P067 + (ML20079P067)
- ML20079P068 + (ML20079P068)
- L-83-103, Responds to IE Bulletin 82-04, Deficiencies in Primary Containment Electrical Penetration Assemblies. No Bunker- Ramo Electrical Penetrations Installed at Facility + (ML20079P071)
- ML20079P072 + (ML20079P072)
- ML20079P076 + (ML20079P076)
- 05000362/LER-1983-003, Forwards LER 83-003/03L-0 + (ML20079P090)
- ML20079P092 + (ML20079P092)
- ML20079P098 + (ML20079P098)
- ML20079P099 + (ML20079P099)
- ML20079P101 + (ML20079P101)
- 05000362/LER-1983-003-03, /03L-0:on 830118,pressurizer Safety Valve Position Indicators Declared Inoperable.Caused by Poorly Attached Position Indication Brackets.Brackets Replaced & After Functional Test & Calibr,Indicators Declared Operable + (ML20079P104)
- ML20079P105 + (ML20079P105)
- RBG-35-877, Forwards Nonproprietary Suppl 1 to EA-PT-91-0003-S, River Bend Station Plant Transient Analysis Methodology - Delta Methodology & Addl Benchmarks + (ML20079P106)
- ML20079P113 + (ML20079P113)
- ML20079P119 + (ML20079P119)
- ML20079P121 + (ML20079P121)
- ML20079P133 + (ML20079P133)
- ML20079P141 + (ML20079P141)
- ML20079P144 + (ML20079P144)
- ST-HL-AE-3921, Submits Special Rept Re Tube Plugged in SG 2D.Tube Experienced anti-vibration Bar Wear of 38% Through Wall Over Two Fuel Cycles of Operation.Tube Wear Did Not Exceed TS Limit of 40% + (ML20079P146)
- 05000416/LER-1983-041, Forwards LER 83-041/03L-0 + (ML20079P152)
- ML20079P154 + (ML20079P154)
- ML20079P157 + (ML20079P157)
- ML20079P158 + (ML20079P158)
- ML20079P159 + (ML20079P159)
- ST-HL-AE-3903, Suppl to Special Rept:On 901126,fuel Oil Leak Noted at Injection Pump 1L of Standby Diesel 23.Caused by Crack on Threaded Portion of Delivery Valve Holder.Injection Pump Delivery Valve & Valve Holder Replaced on 901127 + (ML20079P162)
- ML20079P165 + (ML20079P165)
- ML20079P166 + (ML20079P166)
- ML20079P167 + (ML20079P167)
- ML20079P169 + (ML20079P169)
- ML20079P170 + (ML20079P170)
- ML20079P173 + (ML20079P173)
- ML20079P175 + (ML20079P175)
- ST-HL-AE-3910, Special Rept:On 911006,standby Diesel Generator 21 Tripped & Coasted to Stop.Caused by Malfunction in Amerace Relays in 62CL Circuit Due to End Life.Relays Replaced + (ML20079P176)
- 05000416/LER-1983-041-03, /03L-0:on 830131,maint Personnel Began Opening Eight Penetrations in Control Bldg to Allow Conduit Routing. Caused by Planned Maint.Hourly Fire Watch Conducted on Each Penetration.Updated Rept Will Be Submitted on 830501 + (ML20079P177)
- ML20079P179 + (ML20079P179)
- ML20079P180 + (ML20079P180)
- ML20079P185 + (ML20079P185)
- ML20079P187 + (ML20079P187)
- ML20079P190 + (ML20079P190)
- ML20079P192 + (ML20079P192)
- 05000395/LER-1983-009, Forwards LER 83-009/03L-0.Detailed Event Analysis Encl + (ML20079P193)
- ML20079P195 + (ML20079P195)
- ML20079P198 + (ML20079P198)
- ML20079P200 + (ML20079P200)
- ML20079P202 + (ML20079P202)
- ML20079P204 + (ML20079P204)
- ML20079P211 + (ML20079P211)
- ML20079P222 + (ML20079P222)
- ML20079P224 + (ML20079P224)
- ML20079P227 + (ML20079P227)