- 05000373/LER-1983-096-01, /01T-0:on 830824,RHR Pump B & Shutdown Cooling HX B Secured & RHR Pump a Shutdown Cooling Loop Started.Caused by Lack of Adequate Moderator Temp Indications.Mod to Install Addl Temp Indicator Requested + (ML20077N399)
- ML20077N401 + (ML20077N401)
- ML20077N411 + (ML20077N411)
- ML20077N422 + (ML20077N422)
- ML20077N423 + (ML20077N423)
- ML20077N428 + (ML20077N428)
- 05000251/LER-1983-008-03, /03L-0:on 830806,automatic Turbine Runback to 70% Power Occurred When Rod Cluster N-9 in Shutdown Bank a Dropped.Caused by RCS Leakage from Upper Control Rod N9 Drive Mechanism Housing Vent Valve + (ML20077N430)
- ML20077N442 + (ML20077N442)
- ML20077N445 + (ML20077N445)
- ML20077N451 + (ML20077N451)
- 05000247/LER-1983-025-03, Flow Control Valve 406A on Auxiliary Feedwater Pump 21 Discharge Line to Steam Generator 21 Did Not Open During Surveillance Test.Caused by Chipped Valve Cage.Cage & Gaskets Replaced + (ML20077N454)
- ML20077N459 + (ML20077N459)
- ML20077N461 + (ML20077N461)
- ML20077N463 + (ML20077N463)
- ML20077N481 + (ML20077N481)
- ML20077N482 + (ML20077N482)
- ML20077N493 + (ML20077N493)
- 05000366/LER-1983-075-03, /03L-0:on 830802,hydrogen Recombiner Suction Isolation Valve 2T49-F002A Would Not Pressurize.Caused by Normal Wear & Tear.Valve Repaired + (ML20077N496)
- ML20077N506 + (ML20077N506)
- 05000302/LER-1983-031, Supplementary LER 83-031/03L-1:on 830725,containment Isolation Valve CAV-6 & -7 Would Not Close Under Sys Pressure of 1,000 Psi.Caused by Insufficient Design &/Or Inadequate Maint Procedures + (ML20077N509)
- ML20077N531 + (ML20077N531)
- 05000296/LER-1983-050-03, /03L-0:on 830809,reactor Bldg Vacuum Breakers, Barton Model 289 Differential Pressure Switch,Operated at 0.511 Psid.Caused by Calibr Drift.Switch Recalibr + (ML20077N555)
- ML20077N568 + (ML20077N568)
- ML20077N569 + (ML20077N569)
- ML20077N573 + (ML20077N573)
- ML20077N583 + (ML20077N583)
- ML20077N587 + (ML20077N587)
- ML20077N590 + (ML20077N590)
- NRC-94-4383, Comments on Review of Draft NUREG-1512 for Proprietary Info + (ML20077N600)
- ML20077N615 + (ML20077N615)
- ML20077N624 + (ML20077N624)
- ML20077N630 + (ML20077N630)
- 05000387/LER-1983-106-03, /03L-0:on 830802,during Quarterly Surveillance for HPCI Flow Verification,Pump Did Not Reach Required Speed & Discharge Pressure for Gpm Flow.Caused by Gain on Ramp Generator Signal Converter Drifting Low + (ML20077N639)
- ML20077N663 + (ML20077N663)
- ML20077N667 + (ML20077N667)
- ML20077N673 + (ML20077N673)
- ML20077N679 + (ML20077N679)
- ML20077N685 + (ML20077N685)
- 05000302/LER-1983-032-03, /03L-0:on 830805,meteorological Monitoring Instrumentation Found Inoperable.Caused by Lightning Strike.Components Replaced & Recalibr + (ML20077N705)
- 05000318/LER-1983-033-03, Fire Detection Instrumentation in Containment Southeast Electrical Penetration Area Determined Inoperable.Caused by Pinched Protecto Wire.Wire Repaired + (ML20077N726)
- ML20077N727 + (ML20077N727)
- ML20077N739 + (ML20077N739)
- ML20077N751 + (ML20077N751)
- B13911, Provides Response Re Issue 2 of RI-91-A-0103 + (ML20077N757)
- 05000267/LER-1983-029-03, /03L-0:on 830730,level in Liquid Nitrogen Storage Tank Dipped Below 650 Gallons.Caused by Load of Liquid Nitrogen Not Dispatched from Supplier.Shipment Received on 830730 + (ML20077N763)
- 05000247/LER-1983-031-03, /03L-0:on 830729,during Review of Nonlicensed Operator Log Sheets,Isolation Valve Seal Water Sys Tank Pressure Logged at Pressures Lower than Tech Spec.Caused by Procedural Error.Procedures Revised + (ML20077N777)
- 05000250/LER-1983-012-03, /03L-0:on 830804,auxiliary Feedwater Pump a Failed to Deliver Flow to Steam Generators.Caused by Failed Differential Pressure Transmitter.Transmitter Replaced + (ML20077N783)
- ML20077N798 + (ML20077N798)
- ML20077N799 + (ML20077N799)
- ML20077N810 + (ML20077N810)
- ML20077N817 + (ML20077N817)