n-

.t 1

d-OPERATING DATA REPORT DOCKET NO. 050-0261 DATE 09/00/83 COMPLETED DY H.

RAY NORPIS 1ELEPHONE (003)383-4524 OPERATING STATUS 1.

UNIT NAME: ROBINSON UNIT 2 I NOTES-There are presently 157l

2.. ItEPORTING PERIOD: AUGUST 83 1

spent fuel assemblies in the i

3. LILdNSED THERMAL FOWER (MWT)

,2300 i

Spent Fuel Pool.

l 4

NAMEPLATE RATING (GROSS MWE)

"39.0 l

I

'5.

DESIGN ELECTRICAL RATING (NET MWE) 700.0 I

i 6.

MAX DEPENDADLE CAPACITY (GROSS MUE) 700.0 1 1

7. MAX DEPENDABLE CAPACITY (NET MWE) 665.0.

O.

IF CHANGES OCCUR IN C@ACITY RATINGS (ITEMS 3 'fHRU 7) SINCE LAST REPORT, GIVE REASONS-No change

~

9. POWER LEVEL TO WHICH RESTRICTED IF ANY (NET MWL) 1955 MWt reactor power 10,. REASONS FOR RESTRICTION IF ANY:

Although the unit 'is not restricted by any outside agency, thq, power level is presently reduced due to steam generator, considerations.

/

THIS YR TO CUMUL MONTH DATE A'TIVE

]i'. HOURS IN REPORTING PERIOD 744.00 5831.00 109517.00 r2. NUMDER OF HOURS REACTOR CRITICAL 744.00 5028.09 81867.86 i2i.-REACTOR RESERVE SHUTDOWN HRS

.00 316.83 1624.60 4.

H'luRS GENERATOR DN LINE 744.00 4917.02 79753.06

5. ' UNIT RESERVE SHUTDOWN HO'JRS

.00

.00 23.20 6'.

GROSS THERMAL.' ENERGY GEN. (MWM) 133081i.20 8662127.52 159426719.04 7.

GROSS.ELEC. ENERtY GEN. ( tiWH )

41260'7.00 274059(7.00 51257362.00 D.

NET ELEC. ENERGY GENERATED (MWH) 387602.00 2572995.00 4044509~7.00

9. UNIT SERVICE FACTO,R 100.00 84.33 72.02
9. UNIT AVAILABILITY FACTUR 100.00 84.33 72.84
i. UNIT-CAP. FACTOR (USING MDC NET) 78.34 66.36 66.52 1

2.' UNIT CAP.' FACTOR (USING DER NET) 74.42 63.04 6a.19

.00 4.24 i3.66 3.

UNIT FORCLD OUTAGE RATE 24. SHUTDOWNS SCHED. CVER NEXT 6 MONTHS (TYPE, DATE, AND DURsTION OF EACH)

Type 3, 12-10-83, eight week refueling and maintenance outage.

15. IF SHUTDOWN AT END OF; REPORT PERIOD, ESTIMATED DATE OF STAfdT UP

- Q1 line

16. IJNITN :IN TEST STATUS (PRIOR F0 C0tiMERCIAL OPERAFION)

FORCAST ACHEIVED it 1NITIAL CRITICALITY

- ~ ~ -

i INITIAL ELECI'RICITY COMMERCIAt. OPERATION

- - - - ~

t i

8309130192 830909

[

PDRADOCK05000g L

R 1.16

-9

r---

k I

APPENDIX D i

AVERAGE DAIL POWEP LEVEL e

DOCKET NO. 050-0261 UNIT ROBINSON UNI 1 2 DATE 09/02/03 COMPLETED BY H.

RAY NORRIS TELEPHONE (B03)393-4524 AULUS1 1983 DAY AVG. DAILY POWER LEVEL DAY AVG. DAILY POWER LEVEL (MWE-NET)

(MWE-NET) 1 533 17 520 2

531 18 529 3

526 19 529 9

530 20 526 5

53i 2i 527 6'

532 22 526 i 7 533 23 526 8

532 24 525 9

529 25 526 ii0 527 26 527 f

L 1.

520 27 520 1

i 12 527 28 480

'13 455 29 526 ji4 434 30

' SS 15 529 31 525 16

$20

\\

'J 1.is 0

?

9 l-e s

I

---.----....e on----

- em-recy-,,,--

r

...rmy,..

s-m=.....---,-,,,,r-m m w-e - wv w em

-mww-w wrv,--

UNITSHUTDOWNS AND POWER REDUCTIONS DOCKET NO.

50-261 UNIT NAME H. B. Robinson DAM 830901 H.

Ra (803)y Norris, August COMPLETED BY REPORT MONTH 383-452%

TELEPHONE w.

E E

m 5_ E

$.Y 5 Licensee

,E *

$*3 Cause & Corrective No.

Date g.

gg

,g g 5 Event g?

c-Action to

$5

<5g Report e eU

,5 O Prevent Recurrence

~e; H

.a O

08-01 830801 S

0 A

4 HB HTEXCH Power reduction to approximately y

80% due to steam generator con-siderations.

s 2

3 4

F: F aced Reason:

Method:

Exhibit G - Instructions S: Scheduled A-Fquipment Failure (Explain) 1 Manual for Preparation of Data B-Maintenance of Test 2-Manual Serain.

Entry Sheets for tiensce C Refueling 3-Auto.natic Scram-Esent Ikport (LER) File (SUREG-D Regulatouy Restrietion 4-Ot!.cr (Explain) 0161)

E-Operator Trainin;;& License Examination F-Administiative 5

G-Operational Error (Explain)

Exhibit ! - Same Source (4/77)

Il-Ot! c r ( E xplain)

ev.4 CD&L Carolina Power & Light Company H. B. ROBINSON STEAM ELECTRIC PLANT POST OFFICE COX 790 HARTSVILLE, SOUTH CAROLINA 29550 SEP 0 1993 Robinson File No: -15505 Serial:

RSEP/83-1169 Mr. Richard C. DeYoung, Director Of fice of Inspection & Enforcement U. S. Nuclear Regulatory Commission Washington, DC 20555 H. B. ROBINSON STEAM ELECTRIC PLANT, UNIT NO. 2 DOCKET NO. 50-261 LICENSE NO. DPR-23 FONTHLY OPERATIONS REPORT

Dear Mr. DeYoung:

In accordance with Technical Specification 6.9.1.c for the H. B. Robinson Steam Electric Plant, Unit No. 2. Carolina Power & Light Company herewith submits the report of operation ' statistics and shutdown experience fer the month of August, 1983.

Very truly yours, f

l R. B. Starkey I

General Manager l

H. B. Robinson SEG Plant HRN/th Enclosure cc:

R. A. Hartfield (2)

J. P. O'Reilly (1)

SSY

///

lr n,

- - - - - - - - ~.. -.,

,,--.-,a.,~,,-,----_-,,---..

.w-

. -.. - - -.