Search by property
Jump to navigation
Jump to search
This page provides a simple browsing interface for finding entities described by a property and a named value. Other available search interfaces include the page property search, and the ask query builder.
List of results
- 05000348/LER-1983-025-03, Reactor Coolant Pump 2A Undervoltage Relay 27-3 Declared Inoperable Due to Out of Tech Spec Condition.Caused by Setpoint Drift.Relay Adjusted + (ML20076B352)
- ML20076B364 + (ML20076B364)
- 05000327/LER-1983-098-03, /03L-0:on 830718,glycol Containment Isolation Valve 1-FCV-61-191 Failed Closed.Caused by Failed Diaphragm in Valve Actuator.Diaphragm Replaced + (ML20076B385)
- ML20076B386 + (ML20076B386)
- ML20076B388 + (ML20076B388)
- ML20076B391 + (ML20076B391)
- ML20076B394 + (ML20076B394)
- ML20076B396 + (ML20076B396)
- ML20076B398 + (ML20076B398)
- ML20076B399 + (ML20076B399)
- ML20076B401 + (ML20076B401)
- ML20076B402 + (ML20076B402)
- ML20076B403 + (ML20076B403)
- ML20076B404 + (ML20076B404)
- ML20076B406 + (ML20076B406)
- ML20076B409 + (ML20076B409)
- ML20076B412 + (ML20076B412)
- ML20076B416 + (ML20076B416)
- 05000366/LER-1983-054-03, /03L-0:on 830713,offgas post-treatment Monitor 2D11-K615B Indicated Downscale.Caused by Failure of Scintillation Detector.Offgas post-treatment Monitor Replaced & Returned to Svc + (ML20076B419)
- ML20076B421 + (ML20076B421)
- ML20076B424 + (ML20076B424)
- ML20076B425 + (ML20076B425)
- ML20076B429 + (ML20076B429)
- ML20076B432 + (ML20076B432)
- ML20076B434 + (ML20076B434)
- ML20076B435 + (ML20076B435)
- B13867, Requests Relief from ASME Section XI Requirements for Interim Repair to Pipe 3SWP-030-334-3 at Millstone Unit 3. Addl Info Encl + (ML20076B446)
- ML20076B447 + (ML20076B447)
- ML20076B449 + (ML20076B449)
- ML20076B453 + (ML20076B453)
- ML20076B455 + (ML20076B455)
- 05000280/LER-1983-031-03, /03L-0:on 830710,w/Unit 1 at 100% Power, Containment Temp Exceeded 120 F for Approx 3 H.Caused by Incorrect Data Supplied by Unit 2 Computer.Data Corrected + (ML20076B457)
- ML20076B470 + (ML20076B470)
- 05000389/LER-1983-035-03, /03L-0:on 830712,two of Four Safety Injection Tanks Depressurized to Min Tech Spec Limit During Initial Power Ascension Testing.Cause Not Absolutely Determined. Depressurization Via V-3466 Suspected + (ML20076B472)
- BSEP-83-2702, Ro:On 830730,during Planned Release of Floor Drain Sample Tank A,Determined That Radiological Liquid Waste Effluent Recorder Not Indicating Release Flow Rate.Caused by Blown Protective Fuse + (ML20076B485)
- ML20076B489 + (ML20076B489)
- ML20076B493 + (ML20076B493)
- ML20076B497 + (ML20076B497)
- ML20076B498 + (ML20076B498)
- ML20076B501 + (ML20076B501)
- 05000321/LER-1979-021, Forwards Supplemental Narrative Summary to LER-79-021/03L-0, Rev 5 Re Tritium Levels in Groundwater for Second Quarter 1983 Exceeding ETS Levels + (ML20076B502)
- ML20076B505 + (ML20076B505)
- ML20076B508 + (ML20076B508)
- ML20076B509 + (ML20076B509)
- 05000416/LER-1983-068-01, While in Cold Shutdown, Discrepancy Identified Between Tech Specs & FSAR Re Secondary Containment Ventilation Isolation Damper Closure Time.Cause Unknown + (ML20076B513)
- ML20076B518 + (ML20076B518)
- 05000369/LER-1983-053-03, /03L-0:on 830701,quadrant Power Tilt Ratio Exceeded Tech Spec Limits During Startup Power Increase. Caused by in-core Xenon Imbalance of Unknown Origin.Neutron Flux Increased,Eliminating Xenon by Burnup + (ML20076B521)
- PMNS20200261, Closed Public Meeting to Discuss NEI 09-05 Unattended Opening + (ML20076B522)
- 05000327/LER-1983-090-03, /03L-0:on 830714,w/Unit 1 in Mode 1 & Unit 2 in Mode 1,while Performing SMI-1-SD1B-5,6,900-volt Shutdown Board 1B-B Deenergized.Caused by Personnel Failure to Reset Device 86S1B Before Replacing Trip Cut Blocks + (ML20076B524)
- ML20076B527 + (ML20076B527)
- ML20076B528 + (ML20076B528)