Search by property
Jump to navigation
Jump to search
This page provides a simple browsing interface for finding entities described by a property and a named value. Other available search interfaces include the page property search, and the ask query builder.
List of results
- GO2-82-380, Forwards Final Response to NRC IE Bulletin 79-02,Revision 2 + (ML20071J831)
- ML20071J853 + (ML20071J853)
- 05000272/LER-1982-015, Forwards LER 82-015/03L-0.Detailed Event Analysis Encl + (ML20071J854)
- ML20071J860 + (ML20071J860)
- ML20071J867 + (ML20071J867)
- 05000272/LER-1982-015-03, /03L-0:on 820316,vital Bus 1A Tripped Resulting in Loss of Component Cooling Water & Svc Water Flows.Caused by Shorted Wire in TD5 Undervoltage Relay to Feeder Cubicle Door,Causing Vital Bus 1A to Trip W/O Transfer + (ML20071J879)
- B14906, Forwards Rev 1 to Request for Relief from Section XI of ASME Code Exam Requirements Re 10-yr ISI Program + (ML20071J880)
- 05000443/LER-1994-009, :on 940504,SIP Had Potential to Exceed run-out Flow Rate,Hence Resulting in SIPs Becoming Inoperable.Caused by Loss of SIPs During Hot Leg.Rebalanced Hot Leg Recirculation Flow + (ML20071J895)
- 05000311/LER-1982-025, Forwards LER 82-025/03L-0.Detailed Event Analysis Encl + (ML20071J896)
- ML20071J914 + (ML20071J914)
- 05000277/LER-1983-012-01, /01P:on 830511,insp of Fire Barrier Penetrations Revealed Inadequacies in Penetration Seals.Caused by Const or Design Error & Inadequate Initial Insp.Fire Watches Posted & Addl Insps Initiated + (ML20071J921)
- ML20071J926 + (ML20071J926)
- ML20071J927 + (ML20071J927)
- ML20071J931 + (ML20071J931)
- ML20071J934 + (ML20071J934)
- 05000311/LER-1982-025-03, /03L-0:on 820402,after Closing RHR Pump 22,pump Supply Breaker Opened Due to Phase a Overcurrent Rendering Pump & Related ECCS Subsystem Inoperable.Cause of Breaker Overcurrent Trip Unknown.Pump Tested Satisfactorily + (ML20071J941)
- ML20071J946 + (ML20071J946)
- JAFP-83-0513, Annual Summary of Plant Mods,Changes & Experiments for 1982 + (ML20071J947)
- ML20071J949 + (ML20071J949)
- ML20071J951 + (ML20071J951)
- ML20071J953 + (ML20071J953)
- 05000333/LER-1982-004, Forwards LER 82-004/03X-1 + (ML20071J961)
- ML20071J962 + (ML20071J962)
- ML20071J969 + (ML20071J969)
- ML20071J972 + (ML20071J972)
- ML20071J980 + (ML20071J980)
- 05000305/LER-1983-012-03, /03L-0:on 830420,containment Vent Activity Monitor (R-21) Discovered Out of Svc.Caused by Inadequacy in Administrative & Procedural Controls.Refueling Operations Suspended Per Tech Specs.R-21 Returned to Svc + (ML20071J984)
- ML20071J986 + (ML20071J986)
- 05000333/LER-1982-004-03, /03X-1:on 820227,during Normal Shutdown,Part of Logic Sys Functional Tests Required by Tech Spec Table 4.2.1 Had Not Been Performed.Caused by Procedure Error.Procedure Revised & Surveillance Performed + (ML20071J988)
- 05000318/LER-1982-015, Forwards LER 82-015/03L-0 + (ML20071J992)
- ML20071J998 + (ML20071J998)
- 05000316/LER-1982-023, Forwards LER 82-023/03L-0 + (ML20071K003)
- ML20071K012 + (ML20071K012)
- 05000316/LER-1982-023-03, /03L-0:on 820323,during Containment Spray Nozzle Air Flow Surveillance Test Three Spray Nozzles Found Obstructed.Caused by Duct Tape Over Two,W/Third Covered by Rubber Glove Held W/Tape.Obstructions Removed + (ML20071K018)
- 05000318/LER-1982-015-03, /03L-0:on 820320,during Normal Operation,Negative Limit Setpoint for Channel a of Reactor Protection Sys Axial Shape Index Failed to Operate.Caused by Failure of Axial Power Distribution Module.Module Replaced + (ML20071K028)
- ML20071K032 + (ML20071K032)
- ML20071K034 + (ML20071K034)
- ML20071K057 + (ML20071K057)
- ML20071K064 + (ML20071K064)
- ML20071K071 + (ML20071K071)
- ML20071K077 + (ML20071K077)
- ML20071K078 + (ML20071K078)
- ML20071K085 + (ML20071K085)
- ML20071K086 + (ML20071K086)
- 05000316/LER-1983-043-03, /03L-0:on 830425,review of Train a & B Lower Containment Airborne monitors,ERS-2300 & 2400,revealed Incorrect Wiring Per Approved Physical Prints.Monitors Removed from Svc & Corrections Made + (ML20071K089)
- ML20071K093 + (ML20071K093)
- 05000316/LER-1983-044-03, /03L-0:on 830421,20 Psig Difference Between Pressurizer Pressure Channels Existed.Caused by Pressure Transmitters for NPP-152 & 153 Drifting.Transmitters Satisfactorily Calibr + (ML20071K098)
- ML20071K102 + (ML20071K102)
- ML20071K114 + (ML20071K114)
- ML20071K116 + (ML20071K116)
- ML20071K123 + (ML20071K123)