- BSEP-82-2811, Ro:On 821209,while Performing Corrective Maint on Main Steam Line High Flow Isolation Instrument,Group I Isolation Signal Mistakenly Reset.Placement of Jumpers in Control Logic Allowed Resetting of Isolation.Signal Reinserted + (ML20070E342)
- 05000249/LER-1982-046, Forwards LER 82-046/03L-0 + (ML20070E344)
- ML20070E346 + (ML20070E346)
- ML20070E351 + (ML20070E351)
- 05000416/LER-1982-122, Forwards LER 82-122/99X-0 + (ML20070E352)
- ML20070E358 + (ML20070E358)
- 05000249/LER-1982-046-03, /03L-0:on 821112,water Discovered Spraying from 1-inch Drain Line Off Bottom of Feedwater Regulator Isolation Valve 3A.Caused by Cracked Weld at 1-inch Chain Line Due to Stresses from Thermal Effects + (ML20070E362)
- ML20070E364 + (ML20070E364)
- 05000416/LER-1982-122-99, /99X-0:on 821104,during Shutdown,Cover to HVAC Chase on Elevation 148 Ft in Control Bldg Lower Cable Spreading Room Found Removed.Cause Unknown.Cover Reinstalled.Investigation Continuing + (ML20070E366)
- 05000316/LER-1982-092-03, /03L-0:on 821109,during Normal Operation,Auxiliary Cable Vault (Zone 11) Experienced Inadvertent Carbon Dioxide Discharge & Pyralarm Detector Alarming.Caused by Water Entering Base.Detector & Base Replaced + (ML20070E371)
- ML20070E372 + (ML20070E372)
- 05000373/LER-1982-147, Forwards LER 82-147/03L-0 + (ML20070E380)
- ML20070E383 + (ML20070E383)
- ML20070E385 + (ML20070E385)
- 05000316/LER-1982-094-03, /03L-0:on 821122,during Mode 5 Operation,Rcs Temp Decreased Below Tech Spec Limit for Charging Pump Operation. Caused by Loss of Four Reactor Coolant Pumps & RHR Trains. Two of Three Pumps Racked Out + (ML20070E386)
- 05000373/LER-1982-147-03, /03L-0:on 821111,offgas B Train Hydrogen Analyzer Began Operating Erratically.Caused by Moisture Entering Sensitive Hydrogen Sensors in Units.Hydrogen Sensors Removed,Dried Out & Replaced + (ML20070E389)
- ML20070E390 + (ML20070E390)
- ML20070E391 + (ML20070E391)
- ML20070E393 + (ML20070E393)
- ML20070E395 + (ML20070E395)
- ML20070E396 + (ML20070E396)
- ML20070E403 + (ML20070E403)
- ML20070E406 + (ML20070E406)
- ML20070E407 + (ML20070E407)
- B14888, Proposed Tech Specs Re EDG Fuel Oil Storage Capacity + (ML20070E410)
- NRC-94-4193, Forwards Proprietary Quick Look 00238RP93, SPES-2 Cold Pre- Operational Test Results. Rept Provides NRC W/Info on AP600 Matrix Tests of Sufficient Depth to Enable Early Evaluation & Analysis of Test Results.Rept Withheld (Ref 10CFR2.790) + (ML20070E412)
- ML20070E414 + (ML20070E414)
- ML20070E419 + (ML20070E419)
- ML20070E421 + (ML20070E421)
- ML20070E426 + (ML20070E426)
- ML20070E428 + (ML20070E428)
- ML20070E430 + (ML20070E430)
- ML20070E433 + (ML20070E433)
- ML20070E434 + (ML20070E434)
- ML20070E436 + (ML20070E436)
- 05000416/LER-1982-125, Forwards LER 82-125/03L-0 + (ML20070E439)
- 05000373/LER-1982-150, Forwards LER 82-150/03L-0 + (ML20070E443)
- ML20070E448 + (ML20070E448)
- 05000316/LER-1982-095, Forwards LER 82-095/03L-0 + (ML20070E451)
- ML20070E456 + (ML20070E456)
- 05000316/LER-1982-095-03, /03L-0:on 821111,door to U-2 Cd Diesel Engine Fuel Oil Day Tank Room Designated as Tech Spec Related Fire Door Found Held Open.Cause Not Determined.Door Secured & Redesignated as nonsafety-related Fire Door + (ML20070E457)
- 05000373/LER-1982-150-03, /03L-0:on 821111,RCIC Flow Controller Failed to Control RCIC Sys Flow During Performance of STP-14.Caused by Loose Leads at Square Root Converter 1E51-K601.Leads Tightened.Rcic Sys Successfully Run + (ML20070E461)
- ML20070E465 + (ML20070E465)
- ML20070E467 + (ML20070E467)
- 05000416/LER-1982-125-03, /03L-0:on 821113,200 Gallons of Potentially Contaminated Plant Svc Water Drained to Storm Drains. Effluent Not Sampled Prior to Release.Caused by Personnel Error.Personnel Instructed + (ML20070E470)
- AECM-82-603, Comments on BWROG-8260, NUREG-0737,Item II.K.3.18,Mod of Automatic Depressurization Sys Logic. Option 4,providing Bypass Timer Delay,Will Assure Adequate Core Cooling During Worst Case Conditions + (ML20070E475)
- ML20070E484 + (ML20070E484)
- ML20070E485 + (ML20070E485)
- ML20070E496 + (ML20070E496)
- ML20070E497 + (ML20070E497)
- 05000346/LER-1982-059-03, /03L-0:on 821108,containment post-accident Radiation Monitor,Channel 2 Read Low.On 821116 & 22 Equipment Fail Alarm Received.Caused by Failed High Voltage Power Supply Board.Board Replaced & Declared Operable + (ML20070E502)