Search by property
Jump to navigation
Jump to search
This page provides a simple browsing interface for finding entities described by a property and a named value. Other available search interfaces include the page property search, and the ask query builder.
List of results
- ML20059E838 + (ML20059E838)
- ML20059E839 + (ML20059E839)
- PNO-V-93-001, on 930104,Licensee Notified Region V That Util Board Decided That Plant Will Not Be Restarted & Currently Shutdown for Insp & Repair of SG Tubes.Licensee Notified Media + (ML20059E840)
- ML20059E841 + (ML20059E841)
- ML20059E842 + (ML20059E842)
- 05000245/LER-1993-025, :on 931203,reactor Water clean-up Valves Declared Inoperable.Caused by Inadequate Design.Bypass Jumper Devices Installed on 1-CU-2 & 1-CU-3 to Electrically Bypass Torque Switches + (ML20059E843)
- PNO-V-93-014, on 930811,NRC Was Informed That APS Supervisor Declined to Hire Contract Employee Because Employee Raised Safety Concerns at Plant & Elsewhere.Judge Ruled APS Discriminated Against Employee + (ML20059E845)
- PNO-V-92-034, on 921106,M Debblie Notified Region V Ofc of Overexposure to Radiographer from 50 Ci Co-60 Source. Radiographer Came in Physical Contact W/Source & Undergone Preliminary Medical Exams.State of or Investigating Event + (ML20059E848)
- B14649, Discusses Changes to Reliance on Thermo-Lag,per 921001 Response to NRC Bulletin 92-001,Suppl 1 & 930416 Response to Generic Ltr 92-08 + (ML20059E849)
- ML20059E850 + (ML20059E850)
- ML20059E851 + (ML20059E851)
- ML20059E853 + (ML20059E853)
- 05000382/LER-1993-008-01, :on 931208,TS 3.0.3 Was Entered Due to Chiller a Tripping When Loose Connection Caused Chilled Water Pump a to Trip on Motor Overloads.Replaced B Overload Block for Chilled Water Pump a + (ML20059E855)
- ML20059E856 + (ML20059E856)
- IR 05000344/1990026 + (ML20059E857)
- ML20059E859 + (ML20059E859)
- ML20059E861 + (ML20059E861)
- ML20059E862 + (ML20059E862)
- ML20059E863 + (ML20059E863)
- ML20059E867 + (ML20059E867)
- ML20059E868 + (ML20059E868)
- IR 05000313/1990027 + (ML20059E870)
- ML20059E871 + (ML20059E871)
- ML20059E872 + (ML20059E872)
- ML20059E873 + (ML20059E873)
- ML20059E874 + (ML20059E874)
- ML20059E876 + (ML20059E876)
- 3F0992-13, Forwards Crystal River Unit 3 1992 Radiological Emergency Response Plan Exercise, Scheduled for 921105 + (ML20059E877)
- ML20059E880 + (ML20059E880)
- ML20059E881 + (ML20059E881)
- ML20059E882 + (ML20059E882)
- ML20059E883 + (ML20059E883)
- ML20059E884 + (ML20059E884)
- ML20059E885 + (ML20059E885)
- ML20059E886 + (ML20059E886)
- ML20059E888 + (ML20059E888)
- ML20059E889 + (ML20059E889)
- ML20059E890 + (ML20059E890)
- ML20059E893 + (ML20059E893)
- ML20059E894 + (ML20059E894)
- ML20059E895 + (ML20059E895)
- ML20059E896 + (ML20059E896)
- 05000328/LER-1993-006-01, :on 931203,reactor Tripped as Result of Generator Exciter Problems.Caused by Over Excitation of Generator.Exciter Replaced + (ML20059E897)
- ML20059E898 + (ML20059E898)
- ML20059E899 + (ML20059E899)
- LIC-93-0307, Provides Rept of Mod to Hardware & Software Affecting ERDS Data Point Library + (ML20059E900)
- ML20059E901 + (ML20059E901)
- ML20059E902 + (ML20059E902)
- ML20059E903 + (ML20059E903)
- ML20059E905 + (ML20059E905)
- ML20059E906 + (ML20059E906)