Search by property
Jump to navigation
Jump to search
This page provides a simple browsing interface for finding entities described by a property and a named value. Other available search interfaces include the page property search, and the ask query builder.
List of results
- ML20055A463 + (ML20055A463)
- ML20055A464 + (ML20055A464)
- ML20055A465 + (ML20055A465)
- ML20055A466 + (ML20055A466)
- ML20055A468 + (ML20055A468)
- ML20055A469 + (ML20055A469)
- ML20055A470 + (ML20055A470)
- ML20055A471 + (ML20055A471)
- ML20055A472 + (ML20055A472)
- ML20055A473 + (ML20055A473)
- ML20055A474 + (ML20055A474)
- ML20055A475 + (ML20055A475)
- ML20055A476 + (ML20055A476)
- NUREG-0712, Forwards Suppl 6 to SER,NUREG-0712.W/o Encl + (ML20055A478)
- ML20055A479 + (ML20055A479)
- ML20055A480 + (ML20055A480)
- ML20055A481 + (ML20055A481)
- ML20055A482 + (ML20055A482)
- ML20055A483 + (ML20055A483)
- ML20055A485 + (ML20055A485)
- ML20055A486 + (ML20055A486)
- ML20055A487 + (ML20055A487)
- ML20055A489 + (ML20055A489)
- ML20055A490 + (ML20055A490)
- ML20055A491 + (ML20055A491)
- ML20055A493 + (ML20055A493)
- IR 05000358/1982005 + (ML20055A494)
- IR 05000373/1982028 + (ML20055A496)
- ML20055A497 + (ML20055A497)
- ML20055A499 + (ML20055A499)
- ML20055A500 + (ML20055A500)
- IR 05000305/1982009 + (ML20055A501)
- ML20055A502 + (ML20055A502)
- 05000331/LER-1982-040, Forwards LER 82-040/03L-0 + (ML20055A503)
- 05000316/LER-1982-052, Forwards LER 82-052/03L-0 + (ML20055A505)
- 05000331/LER-1982-040-03, /03L-0:on 820610,during Cold Shutdown Surveillance Testing,Jacket Coolant Sys on Standby Generator Found Leaking.Caused by Brass Pipe Nipple Broken by Weight of Pressure Indicator & Piping.Nipple Replaced + (ML20055A507)
- 05000316/LER-1982-052-03, /03L-0:on 820611,work Bench Found Obstructing Path for Rollup Fire Door Between Two 600-volt Switchgear Areas. Personnel Responsible Not Located.Work Bench Removed.Video Film Being Prepared to Increase Awareness of Requireme + (ML20055A508)
- RBG-12-987, Interim Deficiency Rept Re Loose Mounting Screws or Fasteners Used to Assemble Position Switch Assembly on Limitorque Valve Motor Operators,Initially Reported 811211. Investigation Continuing.Next Rept Expected 820812 + (ML20055A509)
- ML20055A510 + (ML20055A510)
- ML20055A511 + (ML20055A511)
- 2CAN068203, Forwards Corrections to 820416 Response to IE Bulletin 80-06 Re Two Components Inadvertently Listed Incorrectly. Components Are Radiation Elements 2RE-8231-1 & 2RE-8271-2 + (ML20055A512)
- ML20055A513 + (ML20055A513)
- 05000247/LER-1982-023, Forwards LER 82-023/03L-0 + (ML20055A514)
- ML20055A516 + (ML20055A516)
- 05000373/LER-1982-039, Forwards LER 82-039/03L-0 + (ML20055A517)
- 05000247/LER-1982-023-03, /03L-0:on 820606,boron Injection Tank Level Channel 944E Drifted High.Caused by Failure of Bellows Assembly of Associated Level Transmitter.Transmitter Replaced.Failed Channel Replaced W/Spare Channel 944J + (ML20055A519)
- 05000331/LER-1982-043, Forwards LER 82-043/03L-0 + (ML20055A520)
- 05000295/LER-1982-021, Forwards LER 82-021/03L-0 + (ML20055A522)
- 05000373/LER-1982-039-03, /03L-0:on 820609,during Placement of RHR 1A Loop Into Shutdown Cooling Mode,Leakage Discovered at Pump 1A Suction Line.Caused Possibly by Thermal Growth.Leaking Spool Tightened & Leak Repaired + (ML20055A524)
- 05000331/LER-1982-043-03, /03L-0:on 820624,pressure Differential Switches Which Control Reactor Bldg to Suppression Chamber Vacuum Breakers Cv 4304 & Cv 4305 Tripped Out of Spec.Caused by Instrument Drift.Switches Recalibr.Surveillance Continuing + (ML20055A525)