- 05000302/LER-1981-084, Forwards LER 81-084/03L-0 + (ML20040E782)
- 05000336/LER-1981-045-03, /03L-0:on 811230,during Refueling Operations in Mode 6,failure to Perform Surveillance Procedure 2610C-1 for Auxiliary Feedwater Motor Operated Valves Between 811115 & 811122 Discovered.Caused by Personnel Error + (ML20040E784)
- ML20040E785 + (ML20040E785)
- 05000302/LER-1981-084-03, /03L-0:on 811228,chemical Addition Pump 1-B Would Not Pump.Cause Being Investigated.Until Cause Known,Util Is Running Chemical Addition Pumps on Daily Basis to Reduce Possibility of Recurrence + (ML20040E786)
- LD-82-008, Forwards Formal Response to Eg&G Comments on Revision 2 to CENPD-255,revised Section 3.11 to CESSAR-F & Revision 3 to Class IE Qualification of Class IE Electrical Equipment + (ML20040E787)
- ML20040E789 + (ML20040E789)
- 05000324/LER-1982-009, Forwards LER 82-009/01T-0 + (ML20040E790)
- ML20040E792 + (ML20040E792)
- 05000324/LER-1982-009-01, /01T-0:on 820111,svc Water Bldg South Side Sprinkler & Standpipe Sys Isolated While Maint Performed on Fire Support Sys.Caused by Failure of Drawings to Reflect Required Position of Sys Isolation Valves Properly + (ML20040E793)
- ML20040E794 + (ML20040E794)
- ML20040E795 + (ML20040E795)
- ML20040E797 + (ML20040E797)
- IR 05000416/1981059 + (ML20040E801)
- 05000339/LER-1982-001, Forwards LER 82-001/03L-0 + (ML20040E804)
- ML20040E806 + (ML20040E806)
- IR 05000020/1981001 + (ML20040E808)
- IR 05000395/1981033 + (ML20040E809)
- 05000259/LER-1981-068, Forwards LER 81-068/03X-1 + (ML20040E811)
- 05000325/LER-1981-085, Forwards LER 81-085/03L-0 + (ML20040E815)
- 05000325/LER-1981-092-01, /01T-1:on 811226,discussion on 820106,determined That Action Statement 3.3.2b Was Not Entered When Required, When Instrument B21-LT-N017D-1 Failed Upscale.Caused by Personnel Error.Personnel Counseled Re Procedure Importance + (ML20040E817)
- 05000339/LER-1982-001-03, /03L-0:on 820101,RCS Leakage Increased to 15-30 Gpm.Caused by Missing Packing on RHR Isolation Valve. Packing Had Deteriorated & Passed Through Valve Leadoff Line.Valve Repacked,Leak Tested & Returned to Svc + (ML20040E818)
- 05000259/LER-1981-068-03, /03X-1:on 811106,while Transferring 1B 480-volt Shutdown Board to Normal Per Tech Specs,Normal Breaker Failed to close,de-energizing Board.Caused by Safety Pin Inserted in Push Rod.Board Breaker Replaced + (ML20040E819)
- ML20040E820 + (ML20040E820)
- 05000325/LER-1981-085-03, /03L-0:on 811228,820106,07 & 08,reactor Level Instrument 1-B21-LT-N017D-1 Indicated Upscale.Caused by Stem Packing Leak on N017D-1 Ref Leg Excess Flow Check Valve Bypass Valve.Leak Repaired by Adjusting Valve Packing + (ML20040E821)
- 05000328/LER-1981-153, Forwards LER 81-153/03L-0 + (ML20040E822)
- 05000328/LER-1981-153-03, /03L-0:on 811229,flow Control Containment Isolation Valve in Primary Water Makeup Sys Declared Inoperable Due to Failure to Meet Stroke Time Requirements. Caused by Tight Valve Packing.Valve Stem Lubricated + (ML20040E827)
- ML20040E828 + (ML20040E828)
- 05000316/LER-1981-075, Forwards LER 81-075/03L-0 + (ML20040E830)
- ML20040E832 + (ML20040E832)
- 05000316/LER-1981-075-03, /03L-0:on 811231,during Normal Operation,Flow Indicator for Turbine Gland Seal leak-off Failed Low.Cause Unknown.Indicator Installed in Wet Sys Could Be Contributing Factor.Indicator Replaced + (ML20040E834)
- 05000324/LER-1981-145, Forwards LER 81-145/03L-0 + (ML20040E835)
- ML20040E837 + (ML20040E837)
- ML20040E838 + (ML20040E838)
- ML20040E839 + (ML20040E839)
- 05000324/LER-1981-145-03, /03L-0:on 811230,during Quick Start Operability Test,Number 4 Diesel Generator Tripped on Low Lube Oil Pressure.Caused by Oil Sludge Blockage in Instrument Sensing Line to Oil Pressure Switch DG-PS-6534-4.Line Cleared + (ML20040E840)
- ML20040E841 + (ML20040E841)
- ML20040E842 + (ML20040E842)
- ML20040E843 + (ML20040E843)
- IR 05000518/1981020 + (ML20040E844)
- ML20040E845 + (ML20040E845)
- ML20040E846 + (ML20040E846)
- ML20040E847 + (ML20040E847)
- ML20040E848 + (ML20040E848)
- ML20040E849 + (ML20040E849)
- ML20040E853 + (ML20040E853)
- ML20040E855 + (ML20040E855)
- ML20040E857 + (ML20040E857)
- ML20040E858 + (ML20040E858)
- IR 05000416/1981046 + (ML20040E859)
- IR 05000293/1982026 + (ML20040E860)
- ML20040E861 + (ML20040E861)