- ML20027B252 + (ML20027B252)
- ML20027B253 + (ML20027B253)
- 05000366/LER-1982-086, Forwards LER 82-086/03L-0 + (ML20027B255)
- ML20027B256 + (ML20027B256)
- ML20027B257 + (ML20027B257)
- 05000331/LER-1982-051, Forwards LER 82-051/03L-0 + (ML20027B259)
- ML20027B261 + (ML20027B261)
- ML20027B262 + (ML20027B262)
- ML20027B263 + (ML20027B263)
- 05000331/LER-1982-051-03, /03L-0:on 820809,reactor Core Isolation Cooling Steam Line High Pressure Differential Indicating Switch PDIS-2442 Tripped Out of Spec at 98 Inches of Water.Caused by Instrument Drift.Switch Recalibr & Tested + (ML20027B265)
- 05000366/LER-1982-086-03, /03L-0:on 820814,following Control Rod Pattern Adjustment,Core Max Fraction of Limiting Power Density Found Greater than Tech Spec Limit.Caused by Reduction in Xenon Concentration Due to Increased Burnup + (ML20027B266)
- IR 05000456/1981014 + (ML20027B267)
- ML20027B270 + (ML20027B270)
- 05000324/LER-1982-088, Forwards LER 82-088/03L-0 + (ML20027B271)
- ML20027B272 + (ML20027B272)
- ML20027B274 + (ML20027B274)
- ML20027B275 + (ML20027B275)
- ML20027B277 + (ML20027B277)
- ML20027B278 + (ML20027B278)
- ML20027B279 + (ML20027B279)
- 05000281/LER-1982-047-03, /03L-0:on 820812,while at 100% Power,During Performance of PT 18.6B,trip Valve TV-CC-209B Would Not Close When Manually Operated.Caused by Sticking Pilot Valve. Air Supply to Pilot Valve Disconnected + (ML20027B280)
- ML20027B281 + (ML20027B281)
- RBG-13-308, Interim Deficiency Rept Re Installation of Nonseismic Pipe Supports Over Category I Components in Control Bldg. Initially Reported on 820615.Evaluation Not Yet Complete. Next Rept Expected by 821029 + (ML20027B282)
- 05000281/LER-1982-051-03, /03L-0:on 820816,at 100% Power,Heat Tracing Circuit 23C on Panel 8 Found Below Criteria.Cause of Loss Unknown.Defective Heat Tracing Replaced & Tested.Design Change Implemented + (ML20027B283)
- IR 05000424/1982016 + (ML20027B284)
- ML20027B285 + (ML20027B285)
- ML20027B289 + (ML20027B289)
- ML20027B290 + (ML20027B290)
- ML20027B291 + (ML20027B291)
- 05000280/LER-1982-048-03, /03L-0:on 820813,discovered That Uncollected Leakage of 2-CH-P-1C Was in Excess of Tech Spec Limit.Two Pumps Simultaneously Inoperable,Contrary to Tech Specs.Leak Caused by Loose Flange Bolt.Bolt Lubricated + (ML20027B292)
- 05000280/LER-1982-081-03, /03L-0:on 820823,steam Flow Transmitter FT-1-495 Failed Low.Caused by Faulty Power Supply.Power Supply Replaced.Affected Instrument Channel Checked Satisfactorily & Returned to Svc + (ML20027B293)
- ML20027B294 + (ML20027B294)
- 05000280/LER-1982-050-03, /03L-0:on 820817,charging Pump Svc Water Low Pressure Alarm Sounded.Svc Water Pump 10B Auto Started But Did Not Restore Sys Pressure.Caused by Insufficient Npsh. Svc Water to Chiller Reduced & Pump Vented + (ML20027B295)
- ML20027B297 + (ML20027B297)
- ML20027B301 + (ML20027B301)
- ML20027B304 + (ML20027B304)
- ML20027B306 + (ML20027B306)
- ML20027B309 + (ML20027B309)
- ML20027B311 + (ML20027B311)
- 05000339/LER-1982-051, Forwards LER 82-051/03L-0 + (ML20027B313)
- ML20027B315 + (ML20027B315)
- ML20027B316 + (ML20027B316)
- ML20027B317 + (ML20027B317)
- ML20027B318 + (ML20027B318)
- 05000339/LER-1982-051-03, /03L-0:on 820820 & 28,nitrogen Pressure in PORV Reservoir Dropped Below Min Pressure Required to Consider PORV Operable.Caused by Rapid Depletion of Nitrogen Supply Due to Leak in Nitrogen Supply Piping + (ML20027B319)
- 05000259/LER-1982-059, Forwards LER 82-059/03L-0 + (ML20027B320)
- ML20027B321 + (ML20027B321)
- 05000281/LER-1982-052, Forwards LER 82-052/03L-0 + (ML20027B322)
- ML20027B323 + (ML20027B323)
- 05000259/LER-1982-059-03, /03L-0:on 820818,during Calibr of Differential Pressure Switch That Initiates Pressure Suppression Chamber to Reactor Bldg Vacuum Breakers,Switch 1-PDIS-64-21 Operated Above Tech Specs.Caused by Calibr Drift.Switch Recalibr + (ML20027B325)
- 05000281/LER-1982-052-03, /03L-0:on 820812,charging Pump Lubricating Oil Cooler 2-CH-E-5C Found to Be Losing Svc Water Flow, Increasing Bearing Temps on 2-CH-P-1C.Caused by Sticking Float in Svc Water Flow Indicator.Sticking Float Freed + (ML20027B326)