- 05000272/LER-1981-091-03, /03L-0:on 810929 & 1001,Channel 3 Pressurizer Level Read Higher than Other Channels.Caused by Transmitter Drifting Out of Calibr.Transmitter Recalibr + (ML20011A953)
- ML20011A955 + (ML20011A955)
- 05000272/LER-1981-090, Forwards LER 81-090/03L-0.Detailed Event Analysis Encl + (ML20011A957)
- ML20011A958 + (ML20011A958)
- PNO-I-81-118, on 811025,abnormal Gaseous Release Occurred Involving 4.5 Curies of Noble Gas Activity.Cause Still Under Investigation,Suspected That Offgas Recombiner Condensate Drain Tank Was Drained to Sys Sump + (ML20011A959)
- IR 05000344/1981022 + (ML20011A960)
- 05000272/LER-1981-090-03, /03L-0:on 810922,svc Water Found Leaking from Drain Valve 12SW124 Between Valve & Component Cooling Water Heat Exchanger 12.Caused by Crack in Dissimilar Metal Weld Between Valve Body & Carbon Steel Pipe.Pipe Plugged + (ML20011A961)
- ML20011A962 + (ML20011A962)
- 05000318/LER-1981-044, Forwards LER 81-044/03L-0 + (ML20011A964)
- ML20011A965 + (ML20011A965)
- IR 05000312/1981023 + (ML20011A966)
- 05000318/LER-1981-044-03, /03L-0:on 810922,pressurizer Level Had Deviated from Program Level by More than +/-5% Several Times Over 30- Day Period.Cause Attributed to Temp Swings During Startup Operations.Possible Relaxation of Limit Under Review + (ML20011A967)
- 05000334/LER-1981-088, Forwards LER 81-088/03L-0 + (ML20011A968)
- ML20011A969 + (ML20011A969)
- 05000277/LER-1981-026-03, /03L-0:on 810921,during Switching for Loss of Power test,E-4 Diesel Generator Failed to Start.Cooling Water Leak Found from Turbocharger Into Intake Manifolds. Caused by Closed Cooling Water Outlet Valve Left Open + (ML20011A970)
- 05000334/LER-1981-088-03, /03L-0:on 810922,during Normal operation,138 Kv Bus 1 Was Lost.Caused by Inadvertent Operation of Bus Backup Timer Relay 62Z41.Investigation Underway.Details to Follow + (ML20011A971)
- 05000344/LER-1981-023, Forwards LER 81-023/03L-0.Detailed Event Analysis Encl + (ML20011A972)
- 05000277/LER-1981-041-03, /03L-0:on 810923,during HPCI Surveillance Tests, Leak Developed in Gland Seal Condenser Bottom Head Gasket. Caused by Gasket Failure at Bottom Head of Graham Mfg Co Vertical Gland Seal Condenser.Gasket Replaced + (ML20011A974)
- 05000344/LER-1981-023-03, /03L-0:on 810922,during Normal Operation, Containment Atmosphere Sample Return Valve Closed in 10.8-s. Cause Undetermined.Alara Guidelines Restrict Valve Access for Insp During Operation.Insp at Next Refueling Outage + (ML20011A975)
- IR 05000277/1981017 + (ML20011A976)
- ML20011A977 + (ML20011A977)
- IR 05000344/1981021 + (ML20011A979)
- ML20011A980 + (ML20011A980)
- ML20011A981 + (ML20011A981)
- ML20011A983 + (ML20011A983)
- ML20011A984 + (ML20011A984)
- ML20011A985 + (ML20011A985)
- IR 05000272/1981022 + (ML20011A986)
- ML20011A987 + (ML20011A987)
- ML20011A988 + (ML20011A988)
- ML20011A989 + (ML20011A989)
- ML20011A990 + (ML20011A990)
- ML20011A995 + (ML20011A995)
- 05000259/LER-1981-055, Forwards LER 81-055/03L-0 + (ML20011A997)
- ML20011A998 + (ML20011A998)
- ML20011A999 + (ML20011A999)
- 05000259/LER-1981-055-03, /03L-0:on 810927,while Timing New Degraded Voltage Time Delay Relays,Contact on Diesel Generator C Start Relay Failed to Close When Relay Energized.Cause Not Given.Time Delay Relay Replaced + (ML20011B000)
- ML20011B002 + (ML20011B002)
- ML20011B009 + (ML20011B009)
- ML20011B011 + (ML20011B011)
- 05000321/LER-1981-112, Forwards LER 81-112/01T-0 + (ML20011B012)
- ML20011B013 + (ML20011B013)
- ML20011B014 + (ML20011B014)
- IR 05000358/1981024 + (ML20011B016)
- 05000321/LER-1981-112-01, /01T-0:on 811009,during steady-state Power, Discovered Torus to Reactor Containment Bldg Differential Pressure Switches & Static O-ring Had Proof Pressures of 10 & 20 Psig.Caused by Switch Misapplication + (ML20011B018)
- IR 05000029/1981014 + (ML20011B019)
- 05000327/LER-1981-121, Forwards LER 81-121/03L-0 + (ML20011B020)
- ML20011B021 + (ML20011B021)
- ML20011B022 + (ML20011B022)
- ML20011B024 + (ML20011B024)
- 05000327/LER-1981-121-03, /03L-0:on 810925,flux Imbalance Penalty Function Generator XM-92-5005K Found Inoperable.Caused by Module Drift.Module Recalibr + (ML20011B025)