Search by property
Jump to navigation
Jump to search
This page provides a simple browsing interface for finding entities described by a property and a named value. Other available search interfaces include the page property search, and the ask query builder.
List of results
- ML18153B963 + (ML18153B963)
- ML18153B964 + (ML18153B964)
- ML18153B965 + (ML18153B965)
- ML18153B966 + (ML18153B966)
- IR 05000280/1989029 + (ML18153B968)
- IR 05000280/1989028 + (ML18153B969)
- ML18153B971 + (ML18153B971)
- ML18153B972 + (ML18153B972)
- ML18153B973 + (ML18153B973)
- ML18153B974 + (ML18153B974)
- ML18153B975 + (ML18153B975)
- ML18153B976 + (ML18153B976)
- ML18153B977 + (ML18153B977)
- ML18153B978 + (ML18153B978)
- ML18153B979 + (ML18153B979)
- ML18153B980 + (ML18153B980)
- ML18153B981 + (ML18153B981)
- ML18153B982 + (ML18153B982)
- PNO-II-89-075, on 891106 During post-maint Pressure Testing, Pressurizer Safety Valve C Lifted & Reclosed at 2,255 Psig Rather than 2,335 Psig.Loss of Loop Seal Identified as Possible Cause.Util Developing Corrective Actions + (ML18153B983)
- ML18153B984 + (ML18153B984)
- ML18153B985 + (ML18153B985)
- 05000281/LER-1989-013-02, :on 891017,tests Determined That Required Lift Setpoints of 2485 +/- 1% Exceeded on All Tested Valves. Caused by Incorrect Setting of Valve Setpoints.Settings Adjusted to Proper Setpoint & Tolerance + (ML18153B986)
- 05000280/LER-1989-037, :on 891017,steam Generator a Steam Line to Steam Header High Differential Pressure Safety Injection Channel IV Declared Inoperable.Caused by Failure of Pressure Comparator.Comparator Replaced + (ML18153B987)
- ML18153B988 + (ML18153B988)
- ML18153B989 + (ML18153B989)
- ML18153B990 + (ML18153B990)
- ML18153B991 + (ML18153B991)
- ML18153B992 + (ML18153B992)
- 05000281/LER-1989-015-02, :on 891025,slow Boron Dilution of RCS Occurred W/O Containment Integrity.Caused by Misinterpretation of Tech Spec by Senior Reactor Operator Involved.Blender Properly Set Up Using Nomographs + (ML18153B993)
- ML18153B995 + (ML18153B995)
- ML18153B996 + (ML18153B996)
- ML18153B998 + (ML18153B998)
- ML18153B999 + (ML18153B999)
- ML18153C001 + (ML18153C001)
- ML18153C002 + (ML18153C002)
- ML18153C003 + (ML18153C003)
- IR 05000280/1989016 + (ML18153C004)
- ML18153C005 + (ML18153C005)
- ML18153C006 + (ML18153C006)
- ML18153C007 + (ML18153C007)
- 05000280/LER-1989-040, :on 891029,attempts to Reopen Inside Containment Isolation Trip Valve Resulted in Valve Being Declared Inoperable.Caused by Loss of Continuity in Electrical Circuit.Connections Tightened + (ML18153C008)
- 05000281/LER-1989-017-01, :on 891106,pressurizer Safety Valve C Lifted Below Tech Spec Limit.Cause Not Stated.Valve Reset to Required Lift Setpoints W/Steam & Reinstalled W/Loop Seal. Emergency Tech Spec Change Approved by NRC + (ML18153C009)
- 05000281/LER-1989-016-02, :on 891030,main Feedwater Regulating Valve Bypass Valve Closed & Main Feedwater Pump Breakers Tripped Open.Caused by Personnel Error & Procedure Deficiency. Feedwater Control Reset & Components Aligned + (ML18153C010)
- ML18153C011 + (ML18153C011)
- 05000280/LER-1989-042, :on 891031,leak Detected Through Crack in Fillet Weld on Socket Tee Connecting Drain Line to Letdown Line Which Exceeded Allowable Type C Leakage.Caused by Vibration.Line & Valve Configuration Changed + (ML18153C012)
- 05000280/LER-1989-039, :on 891114,steam Generator a Header to Line Differential Pressure Input to Safety Injection Inoperable. Caused by Malfunctioning Relay Contact.Leads Removed from Contacts & Placed on Spare Contacts on Relay + (ML18153C013)
- ML18153C014 + (ML18153C014)
- ML18153C015 + (ML18153C015)
- ML18153C016 + (ML18153C016)
- ML18153C020 + (ML18153C020)
- 05000281/LER-1989-014-02, :on 891117,results of Containment Purge Leak Test Indicated That Containment Purge Supply Penetration Exceeded 10CFR50,App J Leakage Value.Caused by Worn Rubber Seating Matl.Seat Replaced & Surface Cleaned + (ML18153C021)