- ML18139B315 + (ML18139B315)
- 05000280/LER-1981-010-03, /03L-0:on 810415,alarm Setpoints for RM-CC-105 & RM-CC-106 Found Greater than Tech Spec Limits on Several Occasions.Caused by Misinterpretation of Background & Insufficient Guidelines for Evaluation of Alarm Setpoint + (ML18139B316)
- 05000280/LER-1981-023-03, /03L-0:on 810422,PT-39B-2 Indicated Snubbers to Be Inoperable Per Tech Spec 4.17.Caused by Leakage Around Valve Block or Through Connections at Reservoir. Inoperable Snubbers Replaced + (ML18139B317)
- ML18139B318 + (ML18139B318)
- ML18139B319 + (ML18139B319)
- ML18139B321 + (ML18139B321)
- ML18139B322 + (ML18139B322)
- ML18139B323 + (ML18139B323)
- ML18139B324 + (ML18139B324)
- IR 05000280/1981004 + (ML18139B325)
- ML18139B326 + (ML18139B326)
- ML18139B327 + (ML18139B327)
- 05000281/LER-1981-026, Forwards LER 81-026/03L-0 + (ML18139B328)
- ML18139B329 + (ML18139B329)
- 05000281/LER-1981-026-03, /03L-0:on 810429,charging Pump Svc Water Pump 2-SW-P-10A Failed to Operate.Caused by Svc Water Splashing Down Into Motor,Causing Electrical Short & Damaging Windings.Motor Replaced + (ML18139B330)
- ML18139B331 + (ML18139B331)
- ML18139B332 + (ML18139B332)
- ML18139B333 + (ML18139B333)
- ML18139B334 + (ML18139B334)
- 05000280/LER-1981-011, Forwards LER 81-011/03L-0 + (ML18139B345)
- ML18139B346 + (ML18139B346)
- 05000280/LER-1981-011-03, /03L-0:on 810426 & 27,process Vent Radiation Monitors Flooded Due to Introduction of Water Into Process Vent Sys.Caused by Failure of Primary Drain Tank Level Control Sys.Monitors Drained & Vacuum Pump Replaced + (ML18139B347)
- ML18139B348 + (ML18139B348)
- ML18139B350 + (ML18139B350)
- ML18139B351 + (ML18139B351)
- ML18139B352 + (ML18139B352)
- ML18139B353 + (ML18139B353)
- ML18139B354 + (ML18139B354)
- ML18139B355 + (ML18139B355)
- IR 05000280/1981012 + (ML18139B357)
- ML18139B358 + (ML18139B358)
- ML18139B359 + (ML18139B359)
- ML18139B360 + (ML18139B360)
- 05000281/LER-1981-027, Forwards LER 81-027/03L-0 + (ML18139B361)
- ML18139B362 + (ML18139B362)
- 05000281/LER-1981-027-03, /03L-0:on 810501,TV-MS-201C Control Circuit Would Not Respond to Train B Actuation Signal.Caused by Shorting of Train B Coil Due to Moisture.Coil Replaced + (ML18139B363)
- ML18139B364 + (ML18139B364)
- ML18139B365 + (ML18139B365)
- ML18139B366 + (ML18139B366)
- ML18139B367 + (ML18139B367)
- 05000281/LER-1981-028-03, /03L-0:on 810502,emergency Diesel Generator Output Breaker Closed Inadvertently,Motorizing Generator 3.Caused by Inadequate Procedure Not Positively Controlling Generator Position.Generator Started & Loaded + (ML18139B368)
- 05000281/LER-1981-029-03, /03L-0:on 810502,leakage Monitoring Valve 2-CV-12 Found Open & Downstream Pipe Cap Missing Following Return to Power on 810428.Caused by Inadequate Procedure.Valve Closed & Pipe Cap Replaced + (ML18139B369)
- 05000281/LER-1981-030-03, /03L-0:on 810504,emergency Diesel Generator Output Breaker Opened on Overspeed.Caused by Misaligned Overspeed Trip Limit Switch.Limit Switch Adjusted & Generator Tested Satisfactorily + (ML18139B370)