Responds to NRC Re Violations Noted in IE Insp Repts 50-280/81-04 & 50-281/81-04.Corrective Actions:Safety Evaluation Will Be Performed by Engineering Staff Whenever Temporary Shielding Is Requested on safety-related Piping
ML18139B321
Person / Time
Site: Surry  Dominion icon.png
Issue date: 04/20/1981
From: Sylvia B
VIRGINIA POWER (VIRGINIA ELECTRIC & POWER CO.)
To: James O'Reilly
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION II)
Shared Package
ML18139B320 List:
References
205A, NUDOCS 8105260698
Download: ML18139B321 (2)


Text


**-**------=;- ~---**-~------ --- - ~--** --------**- -* ---~ ---------

VI.RGINIA. ELECTRIC A.ND POWER COMPANY RxcHMoN>>,Vrao:rNIA. 23261 April 20, 1981 Mr. James P. O'Reilly, Director Office of Inspection and Enforcement U. S. Nuclear Regulatory Commission Region II 101 Marietta Street, Suite 3100 Atlanta, Georgia 30303

Dear Mr. O'Reilly:

Serial No. 205A NO/RMT:ms Docket Nos. 50-280 50-281 License Nos. DPR-32 DPR-37 In our response to your letter of March 19, 1981 which forwarded Inspection and Enforcement Report Nos. 50-280/81-04 and 50-281/81-04 we stated that a response to the concern referenced in Paragraph 4 would be forthcoming in a follow-up letter. The purpose of this letter is to provide that information as requested.

The information contained in the attached. pages is true and accurate to the best of my knowledge and belief.

Should you require any further information, please contact this office.

Very truly yours,

~/2:.1:s~

~Manager - Nuclear Operations and Maintenance Attachment City of Richmond Commonwealth of Virginia

  • ~ --c,__
-, I Acknowledged before me this.,Zc day of,!:n,_,_,, 19~

Notary Public My Commission expires:

cc:

Mr. Steven A. Varga, Chief Operating Reactors Branch No. 1 Division of Licensing s1o526 o,q-g SEAL

SUPPLEMENTAL RESPONSE TO NRC INSPECTION REPORT NOS. S0-280/81-04 AND 50-281/81-04 Attachment Page 1 Reference the concern expressed in paragraph 4 of the cover letter to subject inspection, the following is our response:

On January 16, 1981, the Station Manager issued a memorandum to all Vepco and Contractual personnel requiring. -a safety evaluation be performed by the Engineering staff whenever temporary shielding is requested on safety related piping.

In order to document any requests and subsequent actions, the follow-ing administrative controls have been implemented.

(1) All requests for temporary shielding shall be originated by the Supervisor-Health Physics using the form generated specifically for this purpose.

Each request shall be dated and identified by number with the original sent to the Supervisor-Engineering Services and a copy retained in the H.P. office.

Note that the form will list the line and/ or component number, location, type shielding required (thickness, quantity, etc., if known) and any general comments concerning the request.

(2)

Engineering shall receive each request, logging the date received and number of each request.

The log shall specify the current disposition (working, cancelled, completed, etc.) of each request.

Engineering shall be responsible for analyzing the request to determine if, in fact, the shielding should and can be installed.

A safety* evaluation shall be documented for each request regardless of the final disposition.

The analysis shall be routed to the Super-visor-Health Physics with a copy retained in the Request Log.

No shielding shall be installed without a completed safety evaluation stating that such shielding does not constitute a safety hazard.

Engineering is investigating the possibility of generating a generic shielding procedure for use on both safety-related and non-safety related installed piping.

The intent of the procedure would be to allow workers in the field to install shielding in accordance with predetermined specifications stipulated in the procedure.

Situations not covered by the procedure would be handled by the shielding request system noted above.

Preliminary results of this investigation are expected to be complete by June 1, 1981.

In regard to the 50 shielding requests submitted during the period of December 1979 to January 1980, the following actions is planned:

The requests will be returned to Station Engineering from Corporate Engineering such that each

  • request can be clarified and re-evaluated.

Clarification will consist of specifying line numbers, more accurate locations, and more detailed descrip-tion of the shielding required.

Following clarification, each request will be re-evaluated to determine if the request. is still valid.

For those requests which are determined valid, they will be reinitiated, utilizing the system previously described.

For those determined as not necessary, the request will be cancelled with a memo stating the justification for cancella-tion.