Search by property
Jump to navigation
Jump to search
This page provides a simple browsing interface for finding entities described by a property and a named value. Other available search interfaces include the page property search, and the ask query builder.
List of results
- ML18093B450 + (ML18093B450)
- ML18093B452 + (ML18093B452)
- ML18093B454 + (ML18093B454)
- 05000272/LER-1989-003, :on 881010,discovered That Relay Room Penetrations,Identified in Sept 1988 Special Rept,Not Addressed Per Tech Specs.Caused by Personnel Not Including Seals in Special Rept.Individuals Counseled + (ML18093B455)
- ML18093B456 + (ML18093B456)
- ML18093B457 + (ML18093B457)
- ML18093B458 + (ML18093B458)
- ML18093B460 + (ML18093B460)
- ML18093B461 + (ML18093B461)
- ML18093B462 + (ML18093B462)
- ML18093B463 + (ML18093B463)
- ML18093B464 + (ML18093B464)
- ML18093B466 + (ML18093B466)
- 05000272/LER-1989-005, :on 890127,Tech Spec Action Statement 3.0.5 Entered Due to Both Trains of ECCS Being Inoperable.Caused by Equipment Problem.Blind Flange Installled on Component Cooling HX Svc Water Inlet Piping 12A + (ML18093B469)
- ML18093B471 + (ML18093B471)
- 05000272/LER-1989-008, :on 890207,blackout Loading on Vital Bus 1C Occurred.Caused by Personnel Error.Personnel Involved Counseled.Lessons Learned Will Be Incorporated Into Appropriate Training Programs + (ML18093B472)
- ML18093B473 + (ML18093B473)
- ML18093B475 + (ML18093B475)
- ML18093B476 + (ML18093B476)
- ML18093B477 + (ML18093B477)
- ML18093B479 + (ML18093B479)
- ML18093B480 + (ML18093B480)
- 05000311/LER-1989-003-01, :on 890205,unit Experienced Rx Trip on Steam Generator 23 Low Level Concurrent W/Steam Flow/Feed Flow Mismatch.Caused by Inadequate Procedures Associated W/ Operating Plant.Procedure AOP-COND-2 Revised + (ML18093B481)
- 05000272/LER-1989-007, :on 890206,reactor Tripped on Steam Generator Low Level Concurrent W/Steam Flow/Feed Flow Mismatch.Caused by Nuclear Control Operator Not Selecting Correct Channel During Performance of Procedure 1PD-2.6.060 + (ML18093B482)
- 05000272/LER-1989-006, :on 890204,1R41C RMS Channel Began Spiking High Resulting in Actuation Signal for Containment Purge/Pressure Vacuum Relief Sys Isolation.Caused by Failed Electrical Components.Monitor Replaced + (ML18093B483)
- ML18093B484 + (ML18093B484)
- ML18093B485 + (ML18093B485)
- ML18093B486 + (ML18093B486)
- ML18093B487 + (ML18093B487)
- ML18093B488 + (ML18093B488)
- ML18093B489 + (ML18093B489)
- ML18093B490 + (ML18093B490)
- ML18093B491 + (ML18093B491)
- ML18093B492 + (ML18093B492)
- ML18093B494 + (ML18093B494)
- ML18093B496 + (ML18093B496)
- ML18093B498 + (ML18093B498)
- ML18093B500 + (ML18093B500)
- 05000272/LER-1989-009, :on 890206,discovered Inadequate Sampling of Plant Vent Effluent Releases.Caused by Inadequate Procedures & Personnel Error.New Composite Sampling Alignment Completed & Procedures Modified + (ML18093B501)
- 05000272/LER-1989-010, :on 890209,two Trains of ESF Sys Made Inoperable by Common Mode.Caused by Equipment Problem.Air Sample Pump Replaced,Monitors Declared Operable on 890210 & Event Will Be Reviewed by Nuclear Training Ctr + (ML18093B502)
- ML18093B503 + (ML18093B503)
- ML18093B504 + (ML18093B504)
- ML18093B505 + (ML18093B505)
- 05000272/LER-1988-017, :880919,steam Flow Channels I & II for Steam Generators 12 & 14 & Channel II for Steam Generator 13 Declared Inoperable Due to Low Reading.Cause Not Determined. Steam Flow Channel Recalibr + (ML18093B507)
- ML18093B508 + (ML18093B508)
- ML18093B509 + (ML18093B509)
- ML18093B510 + (ML18093B510)
- ML18093B511 + (ML18093B511)
- ML18093B512 + (ML18093B512)
- ML18093B513 + (ML18093B513)
- ML18093B514 + (ML18093B514)