Forwards Safety Evaluation Supporting Licensee Response to Generic Ltr 83-28,Item 4.5.2, Reactor Trip Sys Reliability, On-Line Testing
ML18093B498
Person / Time
Site: Salem  PSEG icon.png
Issue date: 03/10/1989
From: Stone J
Office of Nuclear Reactor Regulation
To: Miltenberger S
Public Service Enterprise Group
Shared Package
ML18093B499 List:
References
GL-83-28, TAC-54021, TAC-54022, NUDOCS 8903200368
Download: ML18093B498 (3)


Text

Docket Nos. 50-272/311 Mr. Steven E. Miltenberger Vice President and Chief Nuclear Officer Public Service Electric & Gas Company Post Office Box 236 Hancocks Bridge, New Jersey 08038

Dear Mr. Miltenberger:

March 10, 99 DISTRIBUTION w/enclosure NRC PDR Local PDR PDI-2 Rdg.

GLainas BBoger WButler MO'Brien JStone MThadani OGC EJordan BGrimes ACRS (10)

DLasher AToalston Docket File

SUBJECT:

SAFETY EVALUATION REPORT FOR GENERIC LETTER 83-28, ITEM 4.5.2 (REACTOR TRIP SYSTEM RELIABILITY-ON-LINE TESTING)

(TAC NOS. 54021 AND 54022)

RE:

SALEM GENERATING STATION, UNITS 1 AND 2 Public Service Electric and Gas Company was requested by Generic Letter (GL) 83-28, Item 4.5.2, to confirm that Salem 1 and 2 were designed to permit periodic on-line testing of the Reactor Trip System; and if not, to justify not making modifications to permit such testing.

The enclosed SER documents our concurrence with the findings in our contractor's report (EG&G-NTA-7460),

which concludes that your response to GL 83-28, Item 4.5.2 is acceptable.

We, therefore, consider this item closed by this action.

Enclosure:

Safety Evaluation Report cc w/enclosure:

See next page Previously concurred*

PDI-2/LA*

MO'Brien 03/10/89 PDI-2/PM JStone:mr J I f0/89 Sincerely,

/s/

James C. Stone, Project Manager Project Directorate I-2 Division of Reactor Projects I/II Office of Nuclear Reactor Regulation

~p.R REG(J

.:;,c,'-

(.q,,_

/¥.'o.,,~

UNITED STATES

<(

0

<J>

  • ;: ii:

NUCLEAR REGULATORY COMMISSION WASHINGTON, D. C. 20555 0

~

,t

i._,

~o Docket Nos. 50-272/311 Mr. Steven E. Miltenberger Vice President and Chief Nuclear Officer Public Service Electric & Gas Company Post Office Box 236 Hancocks Bridge, New Jersey 08038

Dear Mr. Miltenberger:

March 10, 1989 SUB'-lECT:

SAFETY EVALUATION REPORT FOR GENERIC LEITER 83-28, ITEM 4."5.2 (REACTOR TRIP SYSTEM RELIABILITY-ON-LINE TESTING)

(TAC NOS. 54021 AND 54022)

RE:

SALEf.1 GENERATING STATION, UNITS 1 AND 2 Public Service Electric and Gas Company was requested by Generic Letter

{GL) 83-28, Item 4.5.2, to confirm that Salem 1 and 2 were designed to permit periodic on-line testing of the Reactor Trip System; and if not, to justify not making modifications to permit such testing. The enclosed SER documents our concurrence with the findings in our contractor's report (EG&G-NTA-7460),

which concludes that your response to GL 83-28, Item 4.5.2 is acceptable.

We,

  • therefore, consider this item closed by this action.

Enclosure:

Safety Evaluation Report cc w/enclosure:

See next page Sincerely,

~to:. P~Oger Project Directorate I-2 Division of Reactor Projects I/II Office of Nuclear Reactor Regulation

Mr. Steven E. Miltenberger Public Service Electric & Gas Company cc:

Mark J. Wetterhahn, Esquire Conner and Wetterhahn Suite 1050 1747 Pennsylvania Avenue, NW Washington, DC 20006 Richard Fryling, Jr., Esquire Law Department - Tower SE 80 Park Place Newark, NJ 07101 Mr. L. K. Miller General Manager - Salem Operations-Salem*Generating Station P.O. Box 236 Hancocks Bridge, NJ 08038 Mr. S. LaBruna Vice President - Nuclear Operations Nuclear Department P.O. Box 236 Hancocks Bridge, New Jersey 08038 Robert Traee, Mayor Lower Alloways Creek Township Municipal Hall Hancocks Bridge, NJ 08038 Kathy Halvey Gibson, Resident Inspector Salem Nuclear Generating Station U.S. Nuclear Regulatory Commission Drawer I Hancocks Bridge, NJ 08038 Richard F. Engel Deputy Attorney General Department of Law and Public Safety CN-112 State House Annex trenton, NJ 08625 Mr. David M. Scott, Chief Bureau of Nuclear Engineering Department of Environmental Protection State of New Jersey CN 411 Trenton, NJ 08625 Salem Nuclear Generating Station Richard B. McGlynn, Commission Department of Public Utilities State of New Jersey 101 Commerce Street Newark, NJ 07102 Regional Administrator, Region I U. S. Nuclear Regulatory Commission 475 Allendale Road King of Prussia, PA 19406 Lower Alloways Creek Township c/o Mary 0. Henderson, Clerk Municipal Building, P.O. Box 157 Hancocks Bridge, NJ 08038 Mr. Bruce A. Preston, Manager Licensing and Regulation Nuclear Department P.O. Box 236 Hancocks Bridge, NJ 08038 Mr. David Wersan Assistant Consumer Advocate Office of Consumer Advocate 1425 Strawberry Square Harrisburg, PA 17120 Scott B. Ungerer MGR. - Joint Generation Projects Atlantic Electric P.O. Box 1500 1199 Black Horse Pike Pleasantville, NJ 08232 Delmarva Power & Light Company c/o Jack Urban General Manager, Fuel Supply 800 King Street P.O. Box 231 Wilmington, DE 19899