ENCLOSURE 2 REVISED PAGES -
UNIT NO. 1 TECHNICAL SPECIFICATIONS
,_---::::.~.(-i:;-1-,;-(:->.-.. -* 1.*=-*.*::;.
..,-i*:::*c_i*=-..1
- =-=-........::. *-* - *=**=*
PDR ADOCK 05000272 p
ALTERNATE INSPECTION SAMPLING PLAN FOR SALEM UNIT 1 The following alternate action may be t'aken in place of that required*by Technical Specification Table 4.4-2 when the results of the initial sample requires that an additional sample or samples must be inspected and the condition for which the added inspection is required is limited to Row 1 and/or Row 2 tubes.
When examination results fall into a C-2 or C-3 Supplemental Sample Category, pursuant to Technical Specification Table 4.4-2 as a result of Row 1 and/or Row 2 U-bend defective or degraded tubes, additional samples may be limited to Rows 1 and 2.
The results of the examination of the Row 1 and Row 2 tubes will be exempt from the additional sampling requirements of Technical Specification Table 4.4-2.
SALEM -
UNIT 1 3/4 4-13a