Browse wiki
Jump to navigation
Jump to search
ML112140464 +
10 CFR 50.72 +, 10 CFR 20 +, 10 CFR 50 +, 10 CFR 50.63 +, 10 CFR 50 Appendix B +, 10 CFR 50.59 +, 10 CFR 61 +, 10 CFR 2.390 +, 10 CFR 20.1501 +, 10 CFR 20.1904 +, 10 CFR 20.2207 +, 10 CFR 50.54 +, 10 CFR 50 Appendix B Criterion V +, 10 CFR 50 Appendix B Criterion XVI +, 10 CFR 50 Appendix B Criterion XI +, 10 CFR 50 Criterion XVI +, 10 CFR 50 Appendix B Criterion III, Design Control +, 10 CFR 50.55a +, 10 CFR 50.73#a2v +, 10 CFR 20.1905#g +, 10 CFR 50.65#b +, 10 CFR 50.65#a1 +, 10 CFR 50.65#a4 +, 10 CFR 50.55a#g6iiD +, 10 CFR 50.65#aiv + and 10 CFR 50 Appendix B Criterion XVII, Quality Assurance Records +
James Anderson +, J. Lash +, Jack Giessner +, M. Milly +, K. Davison +, P. Huffman +, J. Hamilton +, M. Schimmel +, D. Potter +, S. Sharp +, B. Boyer +, T. Downing +, J. Wren +, T. Allen +, K. DeFusco +, Thomas Wengert +, C. Bough +, D. Goble +, J. Muth + and Roland Womack +
05000282/FIN-2011003-01 +, 05000282/FIN-2011003-02 +, 05000282/FIN-2011003-05 +, 05000282/FIN-2011003-06 +, 05000282/FIN-2011003-07 +, 05000282/FIN-2011003-08 +, 05000282/FIN-2011003-09 +, 05000282/FIN-2011003-10 +, 05000306/FIN-2011003-09 +, 05000282/FIN-2011003-04 +, 05000306/FIN-2011003-03 +, 05000306/FIN-2011003-04 +, 05000306/FIN-2011003-02 +, 05000282/FIN-2011002-04 +, 05000306/FIN-2011002-04 +, 05000306/FIN-2011003-05 +, 05000282/FIN-2010006-06 +, 05000306/FIN-2010006-06 +, 05000306/FIN-2011003-06 +, 05000306/FIN-2011003-07 +, 05000306/FIN-2011003-08 + and 05000306/FIN-2011003-10 +
Has query"Has query" is a predefined property that represents meta information (in form of a <a rel="nofollow" class="external text" href="https://www.semantic-mediawiki.org/wiki/Subobject">subobject</a>) about individual queries and is provided by <a rel="nofollow" class="external text" href="https://www.semantic-mediawiki.org/wiki/Help:Special_properties">Semantic MediaWiki</a>.
IR 05000282/2011003 +, IR 05000282/2011003 +, IR 05000282/2011003 +, IR 05000282/2011003 +, IR 05000282/2011003 +, IR 05000282/2011003 +, IR 05000282/2011003 +, IR 05000282/2011003 +, IR 05000282/2011003 +, IR 05000282/2011003 +, IR 05000282/2011003 +, IR 05000282/2011003 +, IR 05000282/2011003 +, IR 05000282/2011003 +, IR 05000282/2011003 +, IR 05000282/2011003 +, IR 05000282/2011003 +, IR 05000282/2011003 +, IR 05000282/2011003 +, IR 05000282/2011003 +, IR 05000282/2011003 +, IR 05000282/2011003 +, IR 05000282/2011003 +, IR 05000282/2011003 +, IR 05000282/2011003 +, IR 05000282/2011003 +, IR 05000282/2011003 +, IR 05000282/2011003 +, IR 05000282/2011003 +, IR 05000282/2011003 +...
TI 2515/183 + and TI 2515/177 +
IP 71111.12 +, IP 71111.18 +, IP 71111.01 +, IP 71111.04 +, IP 71111.06 +, IP 71111.22 +, IP 71111.05 +, IP 71111.13 +, IP 71124.05 +, IP 71124.03 +, IP 71111.19 +, IP 71151 +, IP 71124.02 +, IP 71111.15, Operability Determinations and Functionality Assessments +, IP 71153, Event Followup +, IP 71111.11, Licensed Operator Requalification Program and Licensed Operator Performance +, IP 71111.11Q +, IP 71124.01, Radiological Hazard Assessment and Exposure Controls +, IP 71111.07, Heat Sink Performance +, IP 71111.05A +, IP 71111.05Q +, IP 71111.12Q +, IP 71111.08P +, IP 71111.20, Refueling and Other Outage Activities + and IP 71152, Problem Identification and Resolution (PI&R) +
NRC Inspection Manual 0609 +, NRC Inspection Manual 0609.04 +, NRC Inspection Manual 0609 Appendix H +, NRC Inspection Manual 0609, Appendix K +, NRC Inspection Manual 0609, Appendix G +, NRC Inspection Manual 0609/Appendix C, Occupational Radiation Safety Significance Determination Process +, NRC Inspection Manual 0612, Power Reactor Inspection Reports +, NRC Inspection Manual 0609/Appendix M, Significance Determination Process Using Qualitative Criteria +, NRC Inspection Manual 0612 Appendix E, Examples of Minor Issues + and IMC 0310, Aspects within the Cross-Cutting Areas +
IP 71111.22 +, IP 71111.11, Licensed Operator Requalification Program and Licensed Operator Performance +, IP 71111.04-05 +, IP 71111.05-05 +, IP 71111.12-05 +, IP 71111.13-05 +, IP 71111.15-05 +, IP 71111.18-05 +, IP 71111.19-05 +, IP 71151-05 +, IP 71152-05 +, IP 71111.01-05 +, IP 71111.07-05 +, IP 71111.06-05 +, IP 71124.01-05 +, IP 71124.02-05 +, IP 71124.05-05 +, IP 71153-05 +, IP 71111.20-05 +, IP 71111.08-05 + and IP 71124.03-05 +
August 1, 2011 +
Modification date"Modification date" is a predefined property that corresponds to the date of the last modification of a subject and is provided by <a rel="nofollow" class="external text" href="https://www.semantic-mediawiki.org/wiki/Help:Special_properties">Semantic MediaWiki</a>.
10:07:50, 13 January 2025 +
92 +
Processing error"Processing error" is a predefined property provided by <a rel="nofollow" class="external text" href="https://www.semantic-mediawiki.org/wiki/Help:Special_properties">Semantic MediaWiki</a> and represents errors that appeared in connection with improper value annotations or input processing.
SR-3.0.3 + and SR-3.4.15.1 +
August 1, 2011 +
Minnesota + and Washington +
Steam Generator +, Reactor Coolant System +, Secondary containment +, Emergency Diesel Generator +, Auxiliary Feedwater +, Main Turbine +, Reactor Pressure Vessel +, Residual Heat Removal +, Shield Building +, Circulating Water System +, Main Steam Safety Valve +, Emergency Core Cooling System +, Decay Heat Removal + and Containment Spray +
IR 05000282-11-003; 05000306-11-003, on 04/01/2011 - 06/30/2011; Prairie Island Nuclear Generating Plant, Units 1 and 2; Refueling and Outage Activities; Radiation Monitoring Instrumentation; Event Followup; Other Activities +
Xcel Energy + and Schimmel M +
Unanalyzed Condition +, Boric Acid +, High Radiation Area +, Non-Destructive Examination +, Offsite Dose Calculation Manual +, Water Inventory Control +, Internal Flooding +, Past operability +, Temporary Modification +, B.5.b +, Significance Determination Process +, Design basis earthquake +, Shift Technical Advisor +, Large early release frequency +, Stress corrosion cracking +, Operability Determination +, Severe Accident Management Guideline +, Earthquake +, Through-Wall Leakage +, Fire Protection Program +, Scaffolding +, Substantial potential for an overexposure +, Operability Assessment +, Overexposure +, Water hammer + and Gas accumulation +
URL"URL" is a <a href="/Special:Types/URL" title="Special:Types/URL">type</a> and predefined property provided by <a rel="nofollow" class="external text" href="https://www.semantic-mediawiki.org/wiki/Help:Special_properties">Semantic MediaWiki</a> to represent URI/URL values.
WCAP-17271-P + and WCAP-17276-P +