ML20195J90424 September 1998Rev 0 to TR-VQ1500-02, Clean ECCS Suction Strainer Head Loss Test Rept
ML20129K33218 October 1996Cycle 15 Startup Test ResultsShutdown Margin
ML20100C04424 January 1996Secondary Containment Leak Test Summary
ML20093K77212 October 1995Quad-Cities Nuclear Power Station Unit 2 Cycle 14 Startup Test Results SummaryShutdown Margin
ML20078M90423 November 1994Quad-Cities Nuclear Power Station Unit One Cycle Fourteen Startup Test Results SummaryShutdown Margin
ML20078B92220 October 1994Reactor Containment Bldg Integrated Leak Rate Test,Quad- Cities Nuclear Power Station,Unit 1,940723-24
ML20059G00329 October 1993Revised Quad-Cities Nuclear Power Station Unit 2 Cycle 13 Startup Test Results
ML20056F71624 August 1993Quad-Cities Nuclear Power Station,Unit 2 Cycle 13 Startup Test Results ReptShutdown Margin
ML20056F06219 August 1993Quad-Cities Nuclear Power Station,Unit 1 Cycle 12 Startup Test ResultsShutdown Margin
ML20056F06319 August 1993Quad-Cities Nuclear Power Station,Unit 2 Cycle 12 Startup Test ResultsShutdown Margin
ML20046B57819 May 1993Reactor Containment Bldg Integrated Leak Rate Test Quad- Cities Nuclear Power Station.Packing leak
ML20044C0639 March 1993Cycle 13 Startup Test Rept Summary. W/930309 LtrShutdown Margin
ML20102A69323 July 1992Quad-Cities Nuclear Power Station,Unit 2,Cycle 12 Startup Test ResultsShutdown Margin
ML20099H0526 April 1992Reactor Containment Bldg Integrated Leak Rate Test, Quad-Cities Nuclear Power Station Unit II for Period 920401-06
ML20085A95519 July 1991Quad-Cities Nuclear Power Station Unit 1 Cycle 12 Startup Test ResultsShutdown Margin
ML20077G7942 March 1991Reactor Containment Bldg Integrated Leak Rate Test. W/
ML20011F51426 February 1990Quad-Cities Nuclear Power Station Unit 1 Cycle 11 Startup Test Results. W/900226 LtrShutdown Margin
ML20011E7166 February 1990Reactor Containment Bldg Integrated Leak Rate Test,Quad Cities Nuclear Power Station Unit 1,891114-15.
ML20055C85931 October 1989Special Neutron Attenuation Test for High Density Spent Fuel Racks (Wet), Final ReptFire Protection Program
ML20045H56419 September 1989Equipment Qualification Rept for Moore,Isolator,Moore Signal Transmitter & Marathon Fuse Block,CWE-3840,890919. W/930713 Ltr
ML20206F46416 November 1988Reactor Containment Bldg Integrated Leak Rate Test, 880612-13
ML20205H10719 October 1988Cycle 10 Startup Test ResultsShutdown Margin
ML20153G04213 June 1988Reactor Containment Bldg Integrated Leak Rate Test
ML20150C1546 December 1987Reactor Containment Bldg Integrated Leak Rate Test
ML20153G34825 November 1987Rev 1 to Irradiation Study of Boraflex Neutron Absorber Interim Test Data, Interim Technical Rept
ML20238E29125 June 1987Rev 0 to Irradiation Study of Boraflex Neutron Absorber, Interim Test Data
ML20205K14026 March 1987Quad-Cities Nuclear Power Station Unit 2 Cycle 9 Startup Test ResultsShutdown Margin
ML20210C85915 October 1986Reactor Containment Bldg Integrated Leak Rate Test, Quad-Cities Nuclear Power Station,Unit 2,861014-15
ML20199F13217 June 1986Quad-Cities Nuclear Power Station Unit 1 Cycle 9 Startup Test ResultsShutdown Margin
ML20197A76223 March 1986Reactor Containment Bldg Integrated Leak Rate Test, Quad-Cities Nuclear Power Station,Unit 1,860322-23
ML20134N78728 August 1985Quad-Cities Nuclear Power Station Unit 2,Cycle 8,Startup Test ResultsShutdown Margin
ML20135F12128 May 1985Reactor Containment Bldg Integrated Leak Rate Test, for 850526-28Exemption Request
ML20108A4928 November 1984Cycle 8 Startup Test Results
ML20100N10931 August 1984Reactor Vessel Irradiation Surveillance Program Analysis of Capsule 8, Final Rept
ML20107F09924 July 1984Reactor Containment Bldg Integrated Leak Rate Test, Quad-Cities Nuclear Power Station,Unit One,840724-27
ML20084N0348 May 1984Cycle 7 Startup Test ResultsShutdown Margin
ML20100N11531 March 1984Reactor Vessel Irradiation Surveillance Program Analysis of Capsule 18, Final Rept
ML20084F70910 February 1984Reactor Containment Bldg Integrated Leak Rate Test
ML20082V23813 December 1983As-Found Type B & C Local Leak Rate Test Results for Unit 1 During Last Three Refueling Outages
ML20069P27115 November 1983Environmental Qualification of SC-1300 & ET-1200 Families of Signal Transmitters & Electronic Trips & EI-4400 Analog Isolator SysWeak link
ML20023D26611 May 1983Preliminary Test Rept on Dynamic Testing of Dresden 2 Mechanical Pipe Snubbers.
ML17194B5579 May 19832 Main Steam Monitoring Procedure 7-Day Data Evaluation.
ML20071A83717 February 1983Quad-Cities Nuclear Power Station,Unit 1,Cycle 7 Startup Test ResultsShutdown Margin
ML20028F11520 January 1983Reactor Containment Bldg Integrated Leak Rate Test, Quad-Cities Nuclear Power Station,Unit One,821216-17.Packing leak
ML20042A64115 March 1982Quad-Cities Nuclear Power Station Unit 2,Cycle 6 Startup Test Results.Shutdown Margin
ML19341D6713 April 1981Quad-Cities Nuclear Power Station,Unit 1,Cycle 6 Startup Test Results.Shutdown Margin
ML19318B66519 June 1980Cycle 5 Startup Test Results.Shutdown Margin
ML19321B17112 March 1980Reactor Containment Bldg Integrated Leak Rate Test.
ML19257D15731 December 1979Quad-Cities Nuclear Power Station Units 1 & 2 Secondary Containment Leak Rate Test Summary, Per Tech Specs Section 6.6.C.3
ML19209A79325 September 1979Startup Test 1:Core Loading Verification.