 Issue dateTitleTopic
HL-5657, Ro:On 980626,noted That Pami Channels Had Been Inoperable for More than Thirty Days.Cause Indeterminate.Licensee Will Replace Automatic Function W/Five Other Qualified Pamis of Like Kind in Drywell & Revised Procedures30 July 1998Ro:On 980626,noted That Pami Channels Had Been Inoperable for More than Thirty Days.Cause Indeterminate.Licensee Will Replace Automatic Function W/Five Other Qualified Pamis of Like Kind in Drywell & Revised ProceduresPost Accident Monitoring
HL-5278, Special Rept:On 961203,30 Days Elapsed Since Position Indication Light for MSIV 1B21-F022D Declared Inoperable. Caused by Limit Switch Out of Proper Adjustment for Power Conditions.Light Will Be Restored During Next Outage11 December 1996Special Rept:On 961203,30 Days Elapsed Since Position Indication Light for MSIV 1B21-F022D Declared Inoperable. Caused by Limit Switch Out of Proper Adjustment for Power Conditions.Light Will Be Restored During Next OutagePost Accident Monitoring
HL-5212, Special Rept:On 960721,flood-up Range Reactor Vessel Water Level Instrument 1B21-R605 Out of Svc for Greater than 30 Days.Caused by Packing Leak on Equalizing Valve.Packing Leak on Equalizing Valve Repaired30 July 1996Special Rept:On 960721,flood-up Range Reactor Vessel Water Level Instrument 1B21-R605 Out of Svc for Greater than 30 Days.Caused by Packing Leak on Equalizing Valve.Packing Leak on Equalizing Valve RepairedReactor Vessel Water Level
Packing leak
Post Accident Monitoring
HL-5096, Special Rept 1-95-004:on 951215,emergency Light 1R42-E125 Declared Inoperable for More than 14 Days.Caused by Result of Broken Battery Terminal Discovered During Routine Surveillance Testing.Battery Replaced9 January 1996Special Rept 1-95-004:on 951215,emergency Light 1R42-E125 Declared Inoperable for More than 14 Days.Caused by Result of Broken Battery Terminal Discovered During Routine Surveillance Testing.Battery ReplacedEmergency Lighting
Fire Protection Program
HL-5082, Special Rept I-95-003:on 951117,fire Door 1L-48-1C50 Remained Inoperable for Longer than 14 Days.Caused by Component Failure Resulting from High Usage.Appropriate Fire Detectors Verified7 December 1995Special Rept I-95-003:on 951117,fire Door 1L-48-1C50 Remained Inoperable for Longer than 14 Days.Caused by Component Failure Resulting from High Usage.Appropriate Fire Detectors VerifiedSafe Shutdown
Fire Barrier
Continuous fire watch
Fire Watch
Hourly Fire Watch
HL-5073, Special Rept 2-95-003:on 951029,fire Door 2L48-2R23 Had Remained Inoperable for More than 14 Days to Support Scheduled Refueling Outage Work.Fire Door 2L48-2R23 Restored to Operable Status on 95103128 November 1995Special Rept 2-95-003:on 951029,fire Door 2L48-2R23 Had Remained Inoperable for More than 14 Days to Support Scheduled Refueling Outage Work.Fire Door 2L48-2R23 Restored to Operable Status on 951031Safe Shutdown
Fire Barrier
Continuous fire watch
Hourly Fire Watch
HL-4876, Special Rept:On 950516,fire Doors Blocked Open in Controlled Manner to Provide Addl Cooling for Plant RPS motor-generator Set Rooms.Cause Due to Controlled Actions of Appropriate Personnel.Doors Restored to Operable Status21 June 1995Special Rept:On 950516,fire Doors Blocked Open in Controlled Manner to Provide Addl Cooling for Plant RPS motor-generator Set Rooms.Cause Due to Controlled Actions of Appropriate Personnel.Doors Restored to Operable StatusSafe Shutdown
Fire Barrier
Continuous fire watch
Hourly Fire Watch
HL-4773, Special Rept:On 950113,monitor Displayed Microcomputer Error Code Indicating Inoperability of Flow Transducer in Sampling Sys.Caused by Component Failure.Several Components Replaced or Adjusted in Accordance W/Mfg Recommendations27 January 1995Special Rept:On 950113,monitor Displayed Microcomputer Error Code Indicating Inoperability of Flow Transducer in Sampling Sys.Caused by Component Failure.Several Components Replaced or Adjusted in Accordance W/Mfg Recommendations
HL-0476, Special Rept 2-95-01:on 950110 Unit 2 Drywell High Range Radiation Inoperable Longer than 7 Days.Caused by Exceeding Procedural Limits of 34SV-SUV-019-2S.Technicians Checked High Voltage Power Supply Which Powers Radiation Detectors17 January 1995Special Rept 2-95-01:on 950110 Unit 2 Drywell High Range Radiation Inoperable Longer than 7 Days.Caused by Exceeding Procedural Limits of 34SV-SUV-019-2S.Technicians Checked High Voltage Power Supply Which Powers Radiation Detectors
HL-4727, Special Rept:On 941007,discovered That Required Hourly Fire Watch Patrol Initiated for Fire Area 0040 on 920629 Inappropriately Terminated Due to Personnel Error.Hourly Fire Watch Patrol for Affected Area re-established31 October 1994Special Rept:On 941007,discovered That Required Hourly Fire Watch Patrol Initiated for Fire Area 0040 on 920629 Inappropriately Terminated Due to Personnel Error.Hourly Fire Watch Patrol for Affected Area re-establishedSafe Shutdown
Continuous fire watch
Fire Watch
Hourly Fire Watch
HL-4693, Special Rept 1-94-001:on 940911,seven Days Elapsed Since Main Stack post-accident Effluent Monitoring Sys Declared Inoperable Due to Damage to Sys Electronics by Lightning. Sys Expected to Be Returned to Svc by 94092115 September 1994Special Rept 1-94-001:on 940911,seven Days Elapsed Since Main Stack post-accident Effluent Monitoring Sys Declared Inoperable Due to Damage to Sys Electronics by Lightning. Sys Expected to Be Returned to Svc by 940921Grab sample
HL-4590, Special Rept 2-94-001:on 940517,fire Rated Assembly Was Inoperable for Longer than 14 Days as Result of Planned Activities.Caused by Affected Assemblies & Sealed Devices17 May 1994Special Rept 2-94-001:on 940517,fire Rated Assembly Was Inoperable for Longer than 14 Days as Result of Planned Activities.Caused by Affected Assemblies & Sealed DevicesSafe Shutdown
Continuous fire watch
Hourly Fire Watch
HL-3434, Special Rept 1-93-004:on 930512,discovered That Cable Trays TFQ5-01 & TFR3-01 Were Not Enclosed in Thermo-Lag 330-1 Fire Barrier Matl,Per Safe Shutdown Analysis Rept.Caused by Inadequate Design.Appropriate Fire Detectors Verified30 August 1993Special Rept 1-93-004:on 930512,discovered That Cable Trays TFQ5-01 & TFR3-01 Were Not Enclosed in Thermo-Lag 330-1 Fire Barrier Matl,Per Safe Shutdown Analysis Rept.Caused by Inadequate Design.Appropriate Fire Detectors VerifiedSafe Shutdown
Fire Barrier
Continuous fire watch
Fire Watch
Hourly Fire Watch
HL-3054, Special Rept 2-92-005:on 921102,battery-powered Emergency Lighting Unit Inoperable for More than 72 H.Caused by Failure of Lighting Unit to Pass Regularly Scheduled Maint. Lighting Unit Replaced & Verified Operable2 December 1992Special Rept 2-92-005:on 921102,battery-powered Emergency Lighting Unit Inoperable for More than 72 H.Caused by Failure of Lighting Unit to Pass Regularly Scheduled Maint. Lighting Unit Replaced & Verified OperableEmergency Lighting
HL-2937, Special Rept 1-92-002:on 920911,fire Barrier Assembly Inoperable for Longer than 14 Days Due to Cavity in 3 H Fire Rated Wall.Cause of Cavity Unknown.Cavity in Wall Repaired Under Mwo 1-92-4244 on 9209187 October 1992Special Rept 1-92-002:on 920911,fire Barrier Assembly Inoperable for Longer than 14 Days Due to Cavity in 3 H Fire Rated Wall.Cause of Cavity Unknown.Cavity in Wall Repaired Under Mwo 1-92-4244 on 920918Fire Barrier
Fire Watch
Hourly Fire Watch
HL-2380, Special Rept 1-92-001:on 920804,during Monthly Operability Test on Lighting Unit 1R42-E130,light Failed to Illuminate. Caused by Failure of battery-powered Emergency Lighting Unit to Pass Scheduled Surveillance.Subj Unit Replaced28 August 1992Special Rept 1-92-001:on 920804,during Monthly Operability Test on Lighting Unit 1R42-E130,light Failed to Illuminate. Caused by Failure of battery-powered Emergency Lighting Unit to Pass Scheduled Surveillance.Subj Unit ReplacedEmergency Lighting
HL-2341, Special Rept 2-92-004:on 920630,battery Powered Emergency Lighting Units Inoperable for Period Greater than 72 H.Event Had No Adverse Impact on Nuclear Safety.Battery Discharge Test Performed30 July 1992Special Rept 2-92-004:on 920630,battery Powered Emergency Lighting Units Inoperable for Period Greater than 72 H.Event Had No Adverse Impact on Nuclear Safety.Battery Discharge Test PerformedEmergency Lighting
HL-2247, Special Rept:On 920506,discovered That Annual 8 H Battery Discharge Test on Lighting Unit 2R242-E104 Had Not Been Performed in 1991.Caused by Personnel error.Battery-powered Emergency Lighting Demonstrated Operable5 June 1992Special Rept:On 920506,discovered That Annual 8 H Battery Discharge Test on Lighting Unit 2R242-E104 Had Not Been Performed in 1991.Caused by Personnel error.Battery-powered Emergency Lighting Demonstrated OperableEmergency Lighting
Missed surveillance
HL-2203, Special Rept 2-92-002:on 920407,signal from Triaxial Time History Accelerometer Contained Excessive Amount of Noise & Instrument Declared Inoperable for More than 30 Days.Cause Not Determined.Root Cause Analysis Underway11 May 1992Special Rept 2-92-002:on 920407,signal from Triaxial Time History Accelerometer Contained Excessive Amount of Noise & Instrument Declared Inoperable for More than 30 Days.Cause Not Determined.Root Cause Analysis UnderwayEarthquake
HL-1967, Special Rept 1-91-010:on 911121,discovered That Blue Pen of post-accident Effluent Monitoring Sys Recorder 1D11-R631 Spiking Upscale at Regular Interval.Caused by Failed Flow Transducer.Flow Transducer Replaced5 December 1991Special Rept 1-91-010:on 911121,discovered That Blue Pen of post-accident Effluent Monitoring Sys Recorder 1D11-R631 Spiking Upscale at Regular Interval.Caused by Failed Flow Transducer.Flow Transducer ReplacedGrab sample
HL-1941, Special Rept 1-91-009:from 910929-1029,all Fuel Removed from Reactor Vessel & Fire Barriers Inoperable for More than 14 Days.Caused by Need to Install Support Plates,Platforms & Conduits.Structural Beams Restored to Operable Status22 November 1991Special Rept 1-91-009:from 910929-1029,all Fuel Removed from Reactor Vessel & Fire Barriers Inoperable for More than 14 Days.Caused by Need to Install Support Plates,Platforms & Conduits.Structural Beams Restored to Operable StatusSafe Shutdown
Fire Barrier
Continuous fire watch
Hourly Fire Watch
HL-1916, Special Rept 1-91-008:on 911014,four Suppression Sys Flooding Valves in Fixed Water Suppression Sys Not Surveilled Once Per 18 Months.Caused by Less than Adequate Procedure.Valves Tested & Inspected Per Revised Procedures8 November 1991Special Rept 1-91-008:on 911014,four Suppression Sys Flooding Valves in Fixed Water Suppression Sys Not Surveilled Once Per 18 Months.Caused by Less than Adequate Procedure.Valves Tested & Inspected Per Revised ProceduresMissed surveillance
Continuous fire watch
HL-1891, Special Rept 2-91-003:on 911003,during Performance of Battery Discharge Test,Two Emergency Lighting Units Failed to Illuminate for 8 H & Could Not Be Restored within 72 H. Lighting Units Repaired & Discharge Test Performed31 October 1991Special Rept 2-91-003:on 911003,during Performance of Battery Discharge Test,Two Emergency Lighting Units Failed to Illuminate for 8 H & Could Not Be Restored within 72 H. Lighting Units Repaired & Discharge Test PerformedEmergency Lighting
HL-1682, Rev 2 to Special Rept 1-91-005:on 910515,discovered That Cable Penetration Seal Assembly Not Installed Per Mfg Instructions & Barrier Inoperable for More than 14 Days. Hourly Fire Watch Established & Thermolag Barrier Installed9 October 1991Rev 2 to Special Rept 1-91-005:on 910515,discovered That Cable Penetration Seal Assembly Not Installed Per Mfg Instructions & Barrier Inoperable for More than 14 Days. Hourly Fire Watch Established & Thermolag Barrier InstalledFire Barrier
Hourly Fire Watch
HL-1861, Special Rept 1-91-007:on 910909 & 16,fire Barrier Assemblies Inoperable for More than 14 Days When Unsealed Drilled Hole & Unsealed Penetration Discovered.Caused by Personnel Error.Hole Repaired & Penetration Sealed8 October 1991Special Rept 1-91-007:on 910909 & 16,fire Barrier Assemblies Inoperable for More than 14 Days When Unsealed Drilled Hole & Unsealed Penetration Discovered.Caused by Personnel Error.Hole Repaired & Penetration SealedSafe Shutdown
Fire Barrier
Temporary Modification
Hourly Fire Watch
ML20082B7309 July 1991Special Rept:On 910515 & 0613,cable Penetration Seals Discovered Inoperable & Left in Untested Configuration. Caused by Personnel Error.Hourly Fire Watch Initiated & Penetrations Covered W/Thermolag Fire Barrier MatlFire Barrier
Fire Protection Program
Hourly Fire Watch
HL-1691, Special Rept:On 910526,fixed Water Spray Nozzles Inoperable for Longer than 14 Days Identified During Insp of Fire Sprinkler Sys.Cause Indeterminate.Conduits Routed Away from Vicinity of Spray Nozzles21 June 1991Special Rept:On 910526,fixed Water Spray Nozzles Inoperable for Longer than 14 Days Identified During Insp of Fire Sprinkler Sys.Cause Indeterminate.Conduits Routed Away from Vicinity of Spray NozzlesSafe Shutdown
Fire Barrier
Continuous fire watch
ML20079B91814 June 1991Special Rept 1-91-005:on 910515,fire Barrier Assemblies Inoperable for Longer than 14 Days.Caused by Personnel Error.Penetration Declared Inoperable & Required Hourly Fire Watch EstablishedFire Barrier
Fire Protection Program
Fire Watch
Hourly Fire Watch
HL-1674, Special Rept 2-91-001:on 910320 & 0401,fire-rated Assemblies Inoperable for More than 14 Days Due to Reloading of Reactor Core & Planned Maint Activity,Respectively.Hourly Fire Watch Initiated & Set Room Walls Reinstalled7 June 1991Special Rept 2-91-001:on 910320 & 0401,fire-rated Assemblies Inoperable for More than 14 Days Due to Reloading of Reactor Core & Planned Maint Activity,Respectively.Hourly Fire Watch Initiated & Set Room Walls ReinstalledSafe Shutdown
Fire Barrier
Continuous fire watch
Fire Watch
Hourly Fire Watch
HL-1667, Special Rept 1-91-004:on 910502 & 06,listed battery-powered Emergency Lighting Units Inoperable for More than 72 H. Affected battery-powered Emergency Lighting Units Verified Operable by Performing Monthly Insp6 June 1991Special Rept 1-91-004:on 910502 & 06,listed battery-powered Emergency Lighting Units Inoperable for More than 72 H. Affected battery-powered Emergency Lighting Units Verified Operable by Performing Monthly InspEmergency Lighting
HL-1649, Special Rept:On 910420,fire Barrier Assemblies Inoperable for Period Longer than 14 Days Discovered During Insp.Caused by Personnel Error.Penetrations 2Z43-H66OC & 2Z43-HO27C Resealed & Partially Drilled Hole Repaired21 May 1991Special Rept:On 910420,fire Barrier Assemblies Inoperable for Period Longer than 14 Days Discovered During Insp.Caused by Personnel Error.Penetrations 2Z43-H66OC & 2Z43-HO27C Resealed & Partially Drilled Hole RepairedSafe Shutdown
Fire Barrier
Hourly Fire Watch
HL-1547, Special Rept 1-91-003:on 910318,during Monthly Insp of Fire Door 1L48-1C22,discovered That Door Inoperable for More than 14 Days Due to Worn Hinges,Plates & Shins.Caused by Normal Wear.Fire Watch Established & New Door Ordered2 April 1991Special Rept 1-91-003:on 910318,during Monthly Insp of Fire Door 1L48-1C22,discovered That Door Inoperable for More than 14 Days Due to Worn Hinges,Plates & Shins.Caused by Normal Wear.Fire Watch Established & New Door OrderedSafe Shutdown
Continuous fire watch
Fire Watch
Hourly Fire Watch
HL-1542, Special Rept:On 910301,battery-powered Emergency Lighting Units Inoperable for Period Greater than 72 H.Caused by Personnel Error.Units Restored to Operable Status on 910302 & Surveillance Procedure 42SV-FPX-003-0S Revised25 March 1991Special Rept:On 910301,battery-powered Emergency Lighting Units Inoperable for Period Greater than 72 H.Caused by Personnel Error.Units Restored to Operable Status on 910302 & Surveillance Procedure 42SV-FPX-003-0S RevisedEmergency Lighting
Missed surveillance
HL-1492, Ro:On 910214,potential Malfunction of SRVs Suspected. Caused by Turbine Trip & Reactor Scram Valve Testing. Investigation of Malfunction Planned15 February 1991Ro:On 910214,potential Malfunction of SRVs Suspected. Caused by Turbine Trip & Reactor Scram Valve Testing. Investigation of Malfunction Planned
HL-1470, Special Rept:On 901119,discrepancy Noted in Number of SRM & IRM Detectors During Inventory.Caused by Inadequate Recordkeeping Controls.Responsibility for Control & Accountability of Detectors Returned to Reactor Engineering14 February 1991Special Rept:On 901119,discrepancy Noted in Number of SRM & IRM Detectors During Inventory.Caused by Inadequate Recordkeeping Controls.Responsibility for Control & Accountability of Detectors Returned to Reactor Engineering
HL-1488, Ro:On 910212,potential Malfunction of SRVs Suspected.Caused by Turbine Trip & Re Actor Scram.Investigation of Malfunction Planned13 February 1991Ro:On 910212,potential Malfunction of SRVs Suspected.Caused by Turbine Trip & Re Actor Scram.Investigation of Malfunction Planned
ML20062G36416 November 1990Special Rept:On 901108,reactor Bldg Ventilation Accident Range Radiation Monitor Inoperable for More than Seven Days. Caused by Component Failure.Reactor Bldg Accident Range Radiation Monitor Declared Inoperable
HL-1353, Special Rept 2-90-003 Re fire-rated Assemblies Inoperable W/O Hourly Fire Watch Maintained.Caused by Personnel Error. License Condition 2-90-332 Initiated15 November 1990Special Rept 2-90-003 Re fire-rated Assemblies Inoperable W/O Hourly Fire Watch Maintained.Caused by Personnel Error. License Condition 2-90-332 InitiatedSafe Shutdown
Continuous fire watch
Fire Watch
Hourly Fire Watch
ML20059G3134 September 1990Special Rept 90-004:on 900810,fire-rated Assembly Inoperable for Longer than 14 Days.Caused by Component Failure.Hourly Fire Watch Maintained & Fire Damper ReplacedSafe Shutdown
Fire Barrier
Continuous fire watch
Fire Watch
Hourly Fire Watch
HL-1259, Special Rept 90-001:on 900730,fire-rated Assembly Declared Inoperable for More than 14 Days.Caused by Personnel Error. Hourly Fire Watch Initiated29 August 1990Special Rept 90-001:on 900730,fire-rated Assembly Declared Inoperable for More than 14 Days.Caused by Personnel Error. Hourly Fire Watch InitiatedSafe Shutdown
Continuous fire watch
Fire Watch
Hourly Fire Watch
ML20246J28428 August 1989Special Rept 1-89-002:on 890803,power Cables to Battery Powered Emergency Lighting Units Disconnected.Caused by Plant Mod Activity Which Resulted in Inoperability of Several Battery Powered Emergency Lighting Units for 72 HEmergency Lighting
ML20246F7545 July 1989Special Rept 89-004:on 890525,sealing Devices for Penetrations in 3 H fire-rated East Wall Breached in Excess of 14 Days.Breach Necessitated by Scheduled Work Activities. Penetrations Sealed,Inspected & Declared Operable on 890608Continuous fire watch
Hourly Fire Watch
ML20244B8068 June 1989Special Rept 89-003:on 890509,smoke Detectors Left Inoperable W/O Compensatory Measures Being Taken.Caused by Failure to Reset Alarm at Slave Panel.Smoke Detectors in Battery Rooms Replaced W/Heat DetectorsSafe Shutdown
Fire Barrier
Fire Watch
ML20247K41224 May 1989Special Rept 89-002:on 890414,signal from Triaxial Time History Accelerograph Located Inside Drywell Determined to Contain Excessive Amount of Noise & Declared Inoperable for More than 30 Days.Cause of Event Not DeterminedEarthquake
ML20236B50714 March 1989Special Rept 89-001:on 890216,fire Door Not Restored to Operable Status within 14 Days.Caused by Use of Structural Grouting Procedure Instead of Cosmetic Grouting Procedure. Grouting Placed Underneath Door & Individuals CounseledSafe Shutdown
Fire Barrier
Hourly Fire Watch
ML20235U82028 February 1989Special Rept 89-001:on 890120,fire-rated Assemblies Inoperable for More than 14 Days.Caused by Inadequate Design.Limiting Condition for Operation Established for Each Identified DeficienciesSafe Shutdown
Fire Barrier
Continuous fire watch
Fire Watch
Hourly Fire Watch
ML20196F0187 December 1988Special Rept 88-008:on 881101,fire Watch Not Established & Fire Rated Assembly Not Restored to Operable Condition within 14 Days as Required.Event Had No Adverse Impact on Plant Safety.Personnel Counseled & Cable Tray Encl ModifiedFire Barrier
Continuous fire watch
Fire Watch
Hourly Fire Watch
ML20196E4722 December 1988Special Rept 88-005:on 881105,emergency Light Inoperable for Longer than 24 H Period.Caused by Depleted/Dead Battery. Maint Personnel Replaced Dead Battery Under MWO-2-88-4353Emergency Lighting
ML20151F00821 July 1988Special Rept 88-005:on 880505,fire Wrap Not Installed on Cable Raceways.Caused by Inadequate Guidance Re Application of App R Requirements.Limiting Condition for Operation Established for Each Individual RacewaysFire Barrier
Hourly Fire Watch
ML20196C28722 June 1988Special Rept 88-004:on 880523,determined That Fire Doors W/ Automatic hold-open & Release Mechanisms Were Not Being Verified to Be Free of Obstructions at Least Once Per 24 H as Required.Caused by Inadequate Administrative ControlsSafe Shutdown
Fire Barrier