Semantic search
Jump to navigation
Jump to search
Issue date | Title | Topic | |
---|---|---|---|
ML24018A014 | 17 January 2024 | Engine Systems, Inc., Report No. 10CFR21-0137, Rev. 1, 56913-EN 56913 | Dedication package |
ML24010A213 | 10 January 2024 | CFR 21.21 Final Report Regarding Siemens Medium Voltage Circuit Breakers | |
ML24008A069 | 4 January 2024 | Part 21 Report No. 10CFR21-0137, Rev. 0 for Reportable Notification for an Emo Cylinder Liner with Bore Deficiency, P/N 9318833 (Component of Power Assembly P/N 40124897), S/N 20M0938 | |
ML24018A095 | 4 January 2024 | Engine Systems, Inc., 10CFR21 Reporting of Defects and Non-Compliance Report No. 10CFR21-0137, Rev. 0 | |
ML24002A711 | 28 December 2023 | Interim Part 21 Report of a Deviation or Failure to Comply - Lube Oil Scavenging and Fuel Oil Engine Driven Pump | |
ML23279A061 | 5 October 2023 | Paragon Energy Solutions LLC, Part 21 Final Report Re Potential Defect with Eaton Jd and Hjd Series Molded Case Circuit Breakers (Mccbs) | Commercial Grade Dedication |
ML23060A041 | 1 March 2023 | Part 21 Interim Report of a Deviation or Failure to Comply Associated with a Limitorque Actuator | |
ML23025A253 | 25 January 2023 | Part 21 Final Report Regarding Siemens Medium Voltage Circuit Breakers | |
ML23024A029 | 24 January 2023 | Part 21 Interim Report of a Deviation or Failure to Comply Associated with a Limitorque Actuator | |
ML21225A081 | 4 August 2021 | Lake Engineering Co., Final Report Per 10 CFR Part 21 Degraded Snubber SF1154 Hydraulic Fluid Batch No. 17BLVS293 | |
ML21014A234 | 7 December 2020 | Fourth Interim Notification Per 10 CFR Part 21 Re Degraded Snubber SF1154 Hydraulic Fluid Batch No. 17BLVS293 | |
ML20049A075 | 11 February 2020 | C&D Technologies, Inc. -10 CFR Part 21 Evaluation Regarding Container Failure in KCR-07 Batteries | |
ML20042E252 | 31 January 2020 | EN 54485 Target Rock Redacted Update to Part 21 Report on Defect of Modification of Valve Component and Main Disc Lift Misadjustment | |
ML20029D161 | 21 January 2020 | 10 CFR Part 21 Report, Notification of a Defect Modification of a Valve Component and Main Disc Lift Misadjustment | |
ML20021A045 | 3 January 2020 | Lake Engineering Co. - Interim Notification Per 10 CFR Part 21, Degraded Snubber SF1154 Hydraulic Fluid Batch No. 16DLVS852 | |
ML19190A044 | 7 June 2019 | 10 CFR Part 21 Reporting of Defects for Introl Positioner 890265-010 - Cw SAS Initial Report No. 10CFR21-48 | Overspeed trip Overspeed |
ML19106A106 | 12 April 2019 | Ametek Solidstate Controls - Notification of Potential Defect - 10 CFR Part 21 | |
ML18087A002 | 21 March 2018 | Crane Nuclear, Inc. - Final Report for 10 CFR Part 21 Investigation Report Notification of Xomox Plug Valve High Torsional Stress in Stem | Condition Adverse to Quality |
ML18078A536 | 31 January 2018 | Crane Nuclear, Inc. - Interim Report for 10 CFR Part 21 Investigation Report Notification of Xomox Plug Valve High Torsional Stress in Stem (Update) | |
ML17311A909 | 31 October 2017 | Interim Report for Part 21 Investigation Report Notification of Xomox Plug Valve High Torsional Stress in Stem | |
ML17206A040 | 14 July 2017 | Part 21 - Defective Safety Related Valves | |
ML17179A378 | 7 June 2017 | TE Connectivity - Part 21 Transfer of Information TE-023 | |
ML17114A070 | 13 April 2017 | Part 21 Notification - Identified Fisher 546S Electro-Pneumatic Transducers Standard Mounting Brackets Failed Seismic Testing Standards | |
ML17081A453 | 20 March 2017 | Part 21 - Plastic Jar Dedication Sampling | |
ML17026A414 | 20 January 2017 | C&D Technologies, Inc. - Part 21 - Plastic Jar Dedication Sampling | |
ML16188A374 | 30 June 2016 | Part 21 - Inadequate Swaging and Adherence of Silicone O-Ring and Silicone PAD Soft Seat Main Disc and Pilot Disc Assemblies | |
ML16154A206 | 18 May 2016 | Part 21 Report - Defect in a Signal Converter Transformer | |
ML15254A277 | 8 September 2015 | Part 21 Notification Re Westinghouse Corporation Deviation from Contract Service | Fuel cladding |
ML15223B264 | 6 August 2015 | Part 21 Report - Notification of Deviation Regarding Hk Circuit Breaker Pivot Pin | |
ML15103A244 | 6 April 2015 | Part 21 Report - Deviation of Hk Circuit Breaker Close Latch Spring | Commercial Grade Dedication |
ML15099A043 | 2 April 2015 | Amendment to Event Number 50299, 10 CFR Part 21 Notification, Potentially Defective Pressure & Temperature Switches | |
ML15099A042 | 2 April 2015 | Notification of Part 21 Report - Potentially Defective Pressure & Temperature Switches | |
ML15049A458 | 6 February 2015 | Thermo Gamma-Metrics, LLC - Part 21 Report Regarding Shutdown Margin Monitor Environmental Qualification Noncompliance | Shutdown Margin |
ML15022A650 | 20 January 2015 | Letter from Steven R. Eisenberg USNRC 10CFR Part 21 Notification | |
ML14274A052 | 22 September 2014 | Final Report 10CFR Part 21 Evaluation Regarding Misaligned Separators in LCR-25 Standby Batteries, Revision 1 - Original Letter Did Not Include the List of Affected Utilities | |
ML14213A099 | 24 July 2014 | Notification of Part 21 Report - Potentially Defective Pressure & Temperature Switches | |
ML14126A500 | 2 May 2014 | Part 21 Report Re Check Valves with Missing Jam Nuts | Anchor Darling |
ML13165A342 | 12 June 2013 | 60-Day Interim Report Involving an Evaluation of a Design Change to Magne-Blast Circuit Breakers | |
ML12348A136 | 13 December 2012 | Part 21 60-Day Interim Report Notification: Adequacy of Design Change in Am Magne-Blast Circuit Breakers | |
ML12352A123 | 13 December 2012 | 60-Day Interim Report Involving an Evaluation of a Design Change to Magne-Blast Circuit Breakers | |
ML12123A089 | 27 April 2012 | Abb, Inc., Notification of Potential Part 21 Report - Hk Circuit Breaker Studs Failed to Meet Specification | |
ML12094A371 | 2 April 2012 | Part 21 Report - Rosemount Pressure Transmitters with Nonzero Based Calibrations | |
ML12058A141 | 23 February 2012 | Part 21 Report - Rosemount Nuclear Instruments, Inc., Pressure Transmitter with Nonzero Based Calibrations | |
ML103500174 | 15 December 2010 | Notification of Potential Part 21 Re 60-Day Interim Report Notification: Failure to Include Seismic Input in Channel-Control Blade Interference Customer Guidance | Safe Shutdown Earthquake Operating Basis Earthquake Channel-control blade interference |
ML102930505 | 20 October 2010 | GE Hitachi Nuclear Energy - Notification of Potential Part 21 60-Day Interim Report: Crack Indications in Marathon Control Rod Blades | |
ML101530108 | 28 May 2010 | Notification of Potential Part 21 Re Interim Report - Inability to Complete 10 CFR Part 21 Evaluation Regarding Post Corrosion for Dcu Batteries | |
ML101530564 | 28 May 2010 | Part 21 Notification from C & D Technologies, Inc., Post Corrosion on Dcu Batteries | |
ML100920093 | 25 March 2010 | 10 CFR21 Notification of a Potential Weld Defect | |
ML090761188 | 11 March 2009 | Part 21 Notification - Defective Hk and K-Line Circuit Breaker Tension Springs | |
ML082390106 | 25 August 2008 | Notification of Potential Part 21 on Failure of F and G Switches | Test box |