Issue date | Title | Topic | |
---|---|---|---|
ML23066A221 | 7 March 2023 | Velan, Inc. - Revised Part 21 Notification Re Butterfly Valves Found to Have a Number of Fasteners Loose | |
ML21260A007 | 9 September 2021 | Ametek Solidstate Controls, Notification of Potential Defect - 10CFR Part 21 Report Re Omron Timer Relay | |
ML21225A081 | 4 August 2021 | Lake Engineering Co., Final Report Per 10 CFR Part 21 Degraded Snubber SF1154 Hydraulic Fluid Batch No. 17BLVS293 | |
ML21014A234 | 7 December 2020 | Fourth Interim Notification Per 10 CFR Part 21 Re Degraded Snubber SF1154 Hydraulic Fluid Batch No. 17BLVS293 | |
ML20366A047 | 18 November 2020 | Curtiss-Wright 10 CFR Part 21 Notification for SF-1154 Hydraulic Fluid Batch 17BLVS293 | |
ML19347A426 | 10 December 2019 | General Atomics - Reportable Occurrence Under 10CFR21: Reported Failure in Analog High Range Radiation Monitor (RP-2C) | Post Accident Monitoring |
ML19199A034 | 5 July 2019 | Lake Engineering Co., Third Interim Notification Per 10 CFR Part 21 Degraded Snubber SF1154 Hydraulic Fluid Batch No. ZJS1518 | |
ML18023A407 | 15 December 2017 | Part 21 Report Regarding Disposition of a Nonconformance on Westinghouse/Eaton Cutler Hammer Part Number KD2200U18 (with Trip Unit P/N KT200T and Terminals TA300k Factory Installed) for Palisades | |
ML17081A453 | 20 March 2017 | Part 21 - Plastic Jar Dedication Sampling | |
ML17026A414 | 20 January 2017 | C&D Technologies, Inc. - Part 21 - Plastic Jar Dedication Sampling | |
ML15187A031 | 1 July 2015 | Part 21 Report - Possible Safety Defect in Non-Installed Power Range Detector at Palisades | |
ML15162A027 | 9 June 2015 | Part 21 - Possible Safety Defect in Non-Installed Power Range Detector at Palisades | |
ML15022A650 | 20 January 2015 | Letter from Steven R. Eisenberg USNRC 10CFR Part 21 Notification | |
ML14329A062 | 13 November 2014 | Notification of Potential Part 21 Re Miller Air Cylinder Seals Dedication Issue | Anchor Darling |
ML14321A011 | 13 November 2014 | Notification of Potential Part 21 Re Miller Air Cylinder Seals Dedication Issue Assembly Drawing C06-42515-01 and C06-42515-04 | Anchor Darling |
ML14274A052 | 22 September 2014 | Final Report 10CFR Part 21 Evaluation Regarding Misaligned Separators in LCR-25 Standby Batteries, Revision 1 - Original Letter Did Not Include the List of Affected Utilities | |
ML14268A243 | 16 September 2014 | Final Report 10CFR Part 21 Evaluation Regarding Misaligned Separators in LCR-25 Standby Batteries | |
ML14266A509 | 16 September 2014 | Interim Part 21 Report - Misaligned Separators in LCR-25 Standby Batteries | |
ML14303A526 | 28 March 2014 | Interim Part 21 Report - Misaligned Separators in LCR-25 Standby Batteries | |
ML14094A444 | 28 March 2014 | Interim Part 21 Report - Misaligned Separators in LCR-25 Standby Batteries | |
ML14094A012 | 27 March 2014 | Interim Report - Inability to Complete 10CFR Part 21 Evaluation Regarding Misaligned Separators in LCR-25 Standby Batteries | |
ML14069A468 | 2 March 2014 | Part 21 Report - Defective Raw Material Used to Manufacture Valve Stems | |
ML13165A342 | 12 June 2013 | 60-Day Interim Report Involving an Evaluation of a Design Change to Magne-Blast Circuit Breakers | |
ML12352A123 | 13 December 2012 | 60-Day Interim Report Involving an Evaluation of a Design Change to Magne-Blast Circuit Breakers | |
ML12348A136 | 13 December 2012 | Part 21 60-Day Interim Report Notification: Adequacy of Design Change in Am Magne-Blast Circuit Breakers | |
ML12318A041 | 8 November 2012 | Part 21 Report - Commercial Grade Dedication Not Properly Applied to Butterfly Valves | Commercial Grade Dedication Condition Adverse to Quality |
ML11231A914 | 17 August 2011 | Notification of Potential Part 21 Pump Shaft Coupling Failure | |
ML103060102 | 29 October 2010 | Notification of Potential Part 21 Transfer of Information Concerning Control Components Inc. (CCI) Drag Valves | Boric Acid |
ML093561278 | 16 December 2009 | Hydroaire Services, Inc., Part 21 Involving a Pump Shaft Coupling Failure | |
ML093060395 | 30 October 2009 | Transnuclear, Inc. - Submittal of Thirty Day Written Report of a Potential Deviation and Failure to Comply Associated with Unsubstantiated Certified Materials Test Reports for Certain Small Parts Utilized in Products Fabricated | Operability Determination |
ML082390106 | 25 August 2008 | Notification of Potential Part 21 on Failure of F and G Switches | Test box |
ML080780470 | 13 March 2008 | Notification of Potential Part 21 Report Re Defect in Fairbanks Morse Emergency Diesel Generator Snubber Valve Material and Heat Treatment | Mission time |
ML073200086 | 9 November 2007 | Notification of Potential Part 21 Report Conval Valves Weld Qualifications | Commercial Grade |
ML072750470 | 21 September 2007 | MPR Associates, Inc. - Report of Defect in Accordance with 10 CFR 21 | Commercial Grade Dedication |
ML071370309 | 7 March 2007 | Velan, Inc., Piston Check Cv Information | |
ML040300254 | 28 January 2004 | 10CFR Part 21 Notification Regarding Wide Range Ion Chamber (Update) | |
ML030550248 | 17 February 2003 | 10CFR Part 21 Notification - Carboline Company | Coatings |