13:

Mh 4

.y* _

AUG0 7 19g5 Note to W. T. Crow I

SUBJECT:

TELEPHONE SURVEY, LESSONS LEARNED, NUREG-1198 Per your request, telephone surveys were conducted on August 1 and 4, 1986. Enclosed is your " questionnaire" and the results.

Original si,;noc: *f George H. Bidinger George Bidinger

Enclosure:

1. Questionnaire
2. Results for: CE, 70-36 ENC, 70-1257 GE, 70- 1113 '

W, 70-1151 DISTRIBUTION: _m Docket Nost.70236 M 70-1257 70-1113-70-1151 VLTharoe GBidin'er(5) g FCUP r/f FC Central File NHSS r/f I

In OFC:FLUP :FCUF  :  :  :  :


yky------------------------------------------------

NAME:GBiding r:ht :VLTharpe  :  :  :  :

DATE:08/l/86 :08/'l/86  :  :  :  :

OFFICIAL RECORD COPY 8608180461 860807 PDR ADOCK 07000036 C PDR L

- ' /c wse e/w,, w. A c,e,e-,,is,,g/ac,.,< '

,,, e f ,

(b n h es A k A .se c / ./ 4y<>w / $ w,,,, ,,. a s d ,' , ,,

Seppe.S Au' & //e 4.sscns M ,.-d 2 , ns ':

fc p. / - 4c. / -

/& ps 47 - 7.use Gycr en C/f dues - s/- , ?

&c. 2 - & e w y,a.ss e ,whr/ W hei& J -

- 6 ,,n Ai,,

8e 3 --

fa ,c4 i/aurs c<.sc cf/ , f,Q a/j,/-

i3 uf 6 d.

S'e e s.g .

6./ -

ser 4 hey A & ase n 4+u p p d A,

of GS , , auss o f A Areleves Asno//ed ? Zacu/du Ae. s,,,J4,,,

.A ,aA, &/& .s,o.a<he e- da ,&.e Jdew ?

\

.6 M ac-/ H or 4,ev eece"ed<< y A dc.c.

wL,,y aagn eo J/e' .Aens&c Jeu >,.e>,6 aMz

? ep,

/gand-A,4E,

,,,e~/ so 4 x9 a/Adana n 14.reda. dou, Jk-

  1. Xey 4 /J'/Xj<' nuue1.,m c,vcxespy-d v.

fee .2. s' fa . < t J.,.A & 44dy t/Gx4na i n s ,>e ?

m as,,4-n 4- ?

_7fso, <3 .s4 ,oo A A - o 4,a in Jec.2.5, fee. 2jo A-d ,2 e

' .h . .

EXXON, Docket No. 70-1257 CMalody 08/01/86 2.1.2 (1) No instrumentation.

(2) No relief.

(3) No - Have electric heated air boxes.

2.3.2 (1) No movement; no objection to condition if heels excepted 2.4.2 (1) No cylinders received; would rffag same for resolution 2.5.1 (1) Smoke detectors are in valve box and in vaporization room.

(2) Alarms are in vaporization room and control room, automatic shut-off of room exhaust ventilation, i

4

A f

Combustion Engineering, Docket No. 70-36 H. Eskridge 08/01/86 2.1.2 (1) No instrumentation.

(2) No relief.

(3) No. A near atmospheric pressure steam chest is used.

2.3.2 (1) No movement; no objection to license condition.

2.4.2 (1) No cylinder received; would not apply heat if received.

2.5.2 (1) Steam condensate detector is used. .

(2) High conductivity condensate causes steam shut-off and steam chest atmospheric scrubber to come on line.

9

J f

s -

GE, Docket No. 70-1113 T. P. Winslow 08/04/86 f

ADU Line 2.1.2 (1) Yes.

(2) Yes, heat termination.

(3) No, electric heated air chests.

2.3.2 (1) Yes, occasionally move full cylinder (20/yr).

Yes, would object to 20 weeks of shut down.

2.4.2 (1) Have received some overfilled cylinders.

Place in quarantine and evaluate such cylinders in future.

2.5.2* (1 Yes, detector in chamber and room monitor.

(2 Yes, visual and audible alarm in control room.

GEC0 Lines 2.1.2 (1) Yes.

(2) Yes.

(3) GECO (FM0) Electrically heated hot air chest.

GEC0 (FM0X) HaVe steam autoclaves at 150 psig.

2.3.2 (1) Same as above.

2.4.2 (1) Same as above.

2.5.2* (1) GECO (FM0) Same as ADU lines.

GEC0 (FM0X) Air monitors and steam conductivity GEC0(FM0X)

(2) Visual and audible alarms with UF 6and steam valve closures.

  • Vaporizing and Hydrolysing Areas are designed to contain UF, releases.

Emergency exhaust system goes to recirculation mode without Yresh air intake.

1 1

4

i I , . .

  • Westinghouse, Docket No. 70-1151 EReitler 08/01/86 ADU Line 2.1.2 (1) No instrumentation.

(2) No relief.

(3) No - Have near atmospheric pressure steam chest.

2.3.2 (1) No movement; no objection to license condition.

7-2.4.2 (1) Have received one3 filled cylinder. Do not apply heat.

2.5.2 (1) Steam condensate detector and area airborne alarm in UFg Bay.

(2) Condensate alarm and automatic steam shut-off.

IDR Line 2.1.2 (1) No instrumentation.

(2) No relief.

(3) No. - Have hot water chest.

2.3.2 (1) Same as above.

2.4.2 (1) Same as above.

2.5.2 (1) Hot water conductivity probe.

(2) Conductivity probe alarm and automatic hot water shut-off.

e

.., I t

i i

,IHMSS/FuelCycle Material 1-FCUF_ #

FCAF--

pj;g ,o w 7 o-u s t Docket #_7 o-in3 ,o g157 Prclect #_

Other- _

PDR- /

LPDR_

Return to.+h L SS396

,