NL-15-1483, Refueling Outage 1R26 Inservice Inspection Report

From kanterella
(Redirected from NL-15-1483)
Jump to navigation Jump to search
Refueling Outage 1R26 Inservice Inspection Report
ML15218A079
Person / Time
Site: Farley Southern Nuclear icon.png
Issue date: 08/04/2015
From: Pierce C
Southern Co, Southern Nuclear Operating Co
To:
Document Control Desk, Office of Nuclear Reactor Regulation
References
NL-15-1483
Download: ML15218A079 (190)


Text

Charles R. Pierce Southern Nuclear Regulatory Affairs Director Operating Company, Inc.

40 Inverness Center Parkway Post Office Box 1295 ,

Birmingham, AL 35242 7e,205.992.7872 SOUTH ERN Fax205.992.7601 NUCLEAR A SOUTHERN COMPANy August 4, 2015 Docket Nos. :50-348 NL-1 5-1483 U. S. Nuclear Regulatory Commission ATTN: Document Control Desk Washington, D. C. 20555-0001 Joseph M. Farley Nuclear Plant- Unit 1 Ref uelinqi Outa~qe 1 R26 Inservice Inspection Repjort Ladies and Gentlemen:

Southern Nuclear Operating Company (SNC) submits the Joseph M. Farley Nuclear Plant (FNP) - Unit 1, Interval 4, Period 3, Outage 1 Inservice Inspection Report (Enclosure). This report describes and summarizes the inservice inspection activities performed during the spring 2015 maintenance/refueling outage. Paragraph IWA-6240 of the American Society of Mechanical Engineers (ASME) Boiler and Pressure Vessel Code,Section XI, 2001 Edition with addenda through 2003, requires submittal of the enclosed report.

The supporting inservice inspection documentation (e.g., examination plans and schedules, examination results and reports, examination methods and procedures, evaluation results, and corrective action and repairs) is available for review upon request at FNP.

This letter contains no NRC commitments. If you have any questions, please contact Ken McElroy at (205) 992-7369.

Sincerely, ,) ,

C.R. Pierce Regulatory Affairs Director C RP/J MC/lac

Enclosure:

Joseph M. Farley Nuclear Plant - Unit 1, Inservice Inspection Report, Refueling Outage 1 R26, Owner's Report.

U. S. Nuclear Regulatory Commission NL-1 5-1483 Page 2 cc: Southern Nuclear Operating Company Mr. S. E. Kuczynski, Chairman, President & CEO Mr. D. G. Bost, Executive Vice President & Chief Nuclear Officer Ms. C. A. Gayheart, Vice President - Farley Mr. M. 0. Meier, Vice President - Regulatory Affairs Mr. D. R. Madison, Vice President - Fleet Operations Mr. B. J. Adams, Vice President - Engineering Ms. B. L. Taylor, Regulatory Affairs Manager - Farley RTYPE: CFA04.054 U. S. Nuclear Requlatory Commission Mr. V. M. McCree, Regional Administrator Mr. S. A. Williams, NRR Project Manager - Farley Mr. P. K. Niebaum, Senior Resident Inspector - Farley

Joseph M. Farley Nuclear Plant - Unit 1 Refueling Outage 1 R26 Inservice Inspection Report Enclosure Joseph M. Farley Nuclear Plant - Unit 1 Inservice Inspection Report Ref ueling Outage 1 R26 Owner's Report

INSERVICE INSPECTION REPORT REFUELING OUTAGE 26 INTERVAL 4 PERIOD 3 OUTAGE 1 JM. Farley Nuclear Plant Unit I Hwy 95 South Columbia, Alabama 36319 Southern Nuclear Operating Company 40 Inverness Center Parkway Birmingham, Alabama 35242 COMMERCIAL OPERATION DATE: December 1, 1977 DOCUMENT COMPLETION DATE: August 2015

FNP 1R26 FINAL REPORT INDEX SECTION TA__B VOLUME 1

  • FORM NIS-1 OWNER'S REPORT FOR INSERVICE INSPECTION A
  • BALANCE OF PLANT/REACTOR VESSEL EXAMINATION

SUMMARY

B

  • EXAMINATION PROGRAM PLAN C

SUMMARY

OF RECORDABLE INDICATIONS D

  • FORM NIS-2 OWNER'S REPORTS FOR REPAIRS AND REPLACEMENTS E VOLUME 2
  • EXAMINATION RESULTS F
  • INDICATION EVALUATION REPORTS G VOLUME 3
  • PERSONNEL CERTIFICATIONS H
  • EXAMINATION PROCEDURES (LISTING)
  • EQUIPMENT CERTIFICATIONS J
  • CALIBRATION BLOCKS (LISTING) K VOLUME 4
  • FLOW ACCELERATED CORROSION (FAC) EXAMINATION DATA VOLUME 1 CONTAINS THE INFORMATION TO MEET THE REQUIREMENTS OF ASME SECTION XI CODE, SUBSECTION IWA-6230 AND IWA-6240 OF THE 2001 EDITION THROUGH 2003 ADDENDA FOR SUBMITTAL OF A

SUMMARY

REPORT TO THE NRC FOLLOWING EACH REFUELING OUTAGE.

VOLUMES 2 AND 3 CONTAINS THE SUPPORTING DOCUMENTATION FOR THE EXAMINATIONS PERFORMED (RETAINED ON SITE BY FNP)

VOLUME 4 CONTAINS DOCUMENTATION OF THE FLOW ACCELERATED CORROSION (FAC)

INSPECTIONS PERFORMED (RETAINED ON SITE BY FNP)

SOUTHERN NUCLEAR OPERATING COMPANY INSER VICE INSPECTIONS J. M. FARLEY NUCLEAR PLANT UNIT I REFUELING OUTAGE 26 SPRING 2015 Volume 1 Owner's Report

TAB A FORM NIS-1 OWNER'S REPORT FOR INSERVICE INSPECTION

Page 1 of 4 FORM NIS-1 OWNER'S REPORT FOR INSERVICE INSPECTIONS, As required by the Provisions of the ASME Code Rules

1. Owner Southern Nuclear Operatincj Companv (As agent for Alabama Power Co.)

40 Inverness Center Parkway' Birminqham. AL. 35242

2. Plant J. M. Farley Nuclear Plant Hwy 95 South Columbia, AL. 36319
3. Plant Unit 1
4. Owner Certificate of Authorization (if required) N/A
5. Commercial Service Date 12/01/77
6. National Board Number for Unit see listed N. B. for each component
7. Components Inspected Manufacturer Component or Manufacturer or Installer State or National Appurtenance or Installer Serial No. Province No. Board No.

Reactor Vessel Combustion CE 69104 N/A ,21385 Englineering ________

Reactor Vessel Mitsubishi B-VH-N04 N/A 5846 Closure Head 'Heavy Industries,

___ _ __ _ _ Ltd...... _ __ _ __ _ __ _ __

Centrifugal Pacific Pumps 46354/355/356 NIA 'N/A Charging Pump C Class I Piping Daniel N/A N/A N/A

______________Construction Class 2 Piping Daniel N/A N/A N/A Construction ________________

8. Examination Dates 10/28/13 to 05/7/15.
9. Inspection Period Identification: Third Period - 12/0112014 to 11/30/17
10. Inspection Interval Identification: Fourth Interval - 12/01/07 to 11/30/17
11. Applicable Edition of Section XI 2001 Addenda 2003
  • 12. Date/Revision of Inspection Plan: Volume I - 12/17/14. Ver. 11: Volume 2 - 12/15/14, Ver. 8.0; Volume 3 -12115/14. Ver. 4.0; Volume 6 - 12123114. Ver. 6.0; Volume 7 -01/09/15. Ver. 5.0
13. Abstract of Examinations and Tests. Include a list of examinations and tests and a statement concerning status of wo~rk required for the Inspection Plan. See Tabs B and C
14. Abstract of Results of Examinations and Tests. See Tab B
15. Abstract of Corrective Measures. See Tab B Note: Supplemental sheets in the form of lists, sketches, or drawings may be used, provided (1) size is 8 1/2 in. x 11 in., (2) information in items 1 through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.

Page 2 of 4 FORM NIS-1 We certify that a) the statements made in this report are correct, b) the examinations and tests meet the inspection Plan as required by the ASME Code, Section Xl, and c) corrective measures taken conform to the rules of the ASME Code, Section Xl.

Certificate of Authorization No. (if applicable) NIA Expiration Date N/A Date 7l20Q_*_.Signed Southern Nuclear Operatingi Co. By 7.6? * (*

(Owner) &. /p~.lr u-*~, ,Jr CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of Florida and employed by HSB Global Standards of Hartord, CT have in pecteed the components described in this Owner's Report during the period jo/?.jj7-l too o/o7/z.oI and state that to the best of my knowledge and belief, the Owner has performed examinations and tests and taken corrective measures described in this Owner's Report in accordance with the Inspection Plan and as required by the ASME Code, Section Xl.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations, tests, and corrective measures described in this Owner's Report.

Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

" S ,.,~.l,*. Commissions I 2,L=34 i,4c.. *. s-Inspector's Signature National Board, State, Province, and Endorsements Date V"'t 201(

Page 3 of 4 OWNER'S REPORT FOR INSERVICE INSPECTION OWNER NAME AND ADDRESS: Southern Nuclear Operating Co.

40 Inverness Parkway Birmingham, Alabama 35242 (As agent for Alabama Power Co.)

NAME AND ADDRESS OF NUCLEAR GENERATING PLANT: Joseph M. Farley Nuclear Plant Hwy 95 South Columbia, Alabama 36319 NAME ASSIGNED TO NUCLEAR POWER UNIT: Joseph M. Farley Nuclear Plant Unit I OWNER CERTIFICATE OF AUTHORIZATION: N/A COMMERCIAL SERVICE DATE: 12/01/1977 NATIONAL BOARD NUMBER: See listed NB's for each component NAME OF COMPONENTS OR PARTS OF COMPONENTS INVOLVED: Representative samples of the following components and systems were examined using nondestructive examination techniques.

CLASS 1 i SYSTEM COMPONENT OR SYSTEM DSGAINAPR SKETCH Reactor Vessel B11 1-1100 Reactor Vessel Closure Head B11 1-1300 Reactor Coolant System Bi13 1-4100, 1-4200, 1-4300, 1-4502, 1-4503 Chemical Volume and Control E1140 System Safey IjecionSystm Ei IE211-4103, 1-420,1, 1-4203, 1-4302, Safey SstemE11Inectin E211-4303, 1-4304, 1-4307 Control Rod Drive MechanismF1N/

Supports__________ ____________ ___

Page 4 of 4 CLASS 2 SYSTEM COMPONENT OR SYSTEM DSGAINAPR SKETCH Centrifugal Charging Pump E21 2-5120 2-4701, 2-4704, Containment Spray E13 2402-4705, 2-4707, Chmcl oue n onrlE21 2-4509, 2-4511, 2-4513, 2-4604 System Residual Heat Removal System ElI 2-4502, 2-4504, 2-4506, 2-4514, 2-4517, 2-4518 2-4533, 2-4537, 2-4538, 2-4615, Safety Injection System E21 2-4623, 2-4627, 2-4631, 2-4632,

_________________________2-4636 Main Steam System Nil 2-41 01 NAME OF AUTHORIZED NUCLEAR INSERVICE INSPECTOR: Rodney Senn NAME AND MAILING ADDRESS OF INSPECTOR'S EMPLOYER: Hartford Steam Boiler Inspection and Insurance Company of Connecticut One State Street Hartford, CT 06103

TAB B BALANCE OF PLANT/REACTOR VESSEL EXAMINATION

SUMMARY

J. M. FARLEY NUCLEAR PLANT UNIT NO 1 INTERVAL 4 PERIOD 3 OUTAGE 1 BALANCE OF PLANTIREACTOR VESSEL EXAMINATION

SUMMARY

INTRODUCTION The ASME Boiler and Pressure Vessel Code, Section Xl, 2001 Edition .(Code), 2003 Addenda, is the applicable code for conducting inservice inspection activities during the fourth ten-year inspection interval at Farley Unit 1. Examinations and tests required by the Code are scheduled in accordance with "inspection Program B" as defined in Code paragraphs IWB-2412 and IWC-2412. This "Owner's Report for Inservice Inspection" is for those third inspection period examinations and tests which were performed between October 28, 2013 (end of the twenty-fifth maintenance/refueling outage, 1R25 / 4-2-2) and May 7, 2015 (end of the twenty-sixth maintenance/refueling outage, 1R26 / 4-3-1).

The examinations were performed in accordance with the approved Outage Plan. The primary areas of examination included the Reactor Pressure Vessel (RPV) Bottom Head Mounted Instrumentation (BMI), RPV Closure Head Control Rod Drive Mechanism (CRDM) penetrations, and various Class 1 and Class 2 piping welds, supports and welded attachments. The tables documenting the Class 1 and 2 vessel, piping, and component support examinations are located in Tab C of this report.

Farley Nuclear Plant has implemented ASME Section XI, Appendix VIII, 'Performance Demonstration for Ultrasonic Examination Systems," as required by 10CFR 50.55a, amended by the Federal/RegisterNotices 64 FR 51370 dated September 22, 1999, as later modified by 69 FR 58804, dated October 1, 2004. The 2004 Rule incorporated the 2001 Edition with NRC caveats. Farley has, except where requests for relief, technical alternatives or exemptions have been approved complied with the requirements for expedited implementation of the applicable Appendix VIII supplements using the EPRI Performance Demonstration Initiative (PDI).

In addition to the summary of inservice inspection activities, this report addresses Code-applicable repairs and replacements documented at FNP-1 since 1R25 through the end of 1R26. Owner's Reports for Repairs or Replacements (Form NIS-2) are provided herein, It should be noted that an arrangement with an Authorized Inspection Agency was provided for those examinations and tests required by the Code. ASME Section XI examinations and tests are itemized in the applicable sections by reference to Examination Category. Examinations which do not meet the Code-required coverage either reference request(s) for relief or indicate that additional relief is required.

This report does not include a summary of the Steam Generator Tube Inspections which are required per FNP Technical Specification 5.6.10. This is normally provided in a separate report one hundred eighty (180) days after the initial entry into MODE 4 following completion of an inspection performed in accordance with Technical Specification 5.5.9. Steam Generator tube inspections were performed during the 2 6 th refueling outage.

-RESULTS If examinations resulted in recordable indication areas being noted on the basis of procedure recording criteria, which generally are more conservative than specified in the ASME Section XI Acceptance Standard, they are listed in a table under Tab D. SNC defines recordable indications as indications from a nondestructive examination that required evaluation to Code criteria or other applicable standards.

Reportable indications are defined as recordable indications that have been evaluated and are Code rejectable. If necessary and applicable, indications were evaluated and dispositioned by Indication Evaluation Reports (IER's). A listing of IER's is attached and the data sheets or evaluations are available at FNP for review. The results are summarized under Tab D.

SUMMARY

OF INDICATIONS CLASS I (A) VOLUMETRIC EXAMINATIONS

  • There were no reportable Class 1 Volumetric indications.
  • One (1) class 1 weld had limited volumetric coverage during UT examinations because of physical limitations due to the configuration of the welded area. More than ninety percent (90%)

of the required volume must be examined as addressed in ASME Section XI Code Case N-460 for adequate ASME Section XI Code-required examination coverage to be attained. As noted herein, the subject code case has been approved by the NRC for use as documented in NRC Regulatory Guide 1.147. It is impractical to achieve the ASME Section XI Code-required coverage due to the configuration of the welded area. These limited examinations will be submitted to the NRC through the relief request process as allowed by 10 CFR 50.55a.

(B) SURFACE EXAMINATIONS

  • There were no reportable Class 1 Surface indications.

(C) VISUAL EXAMINATIONS

  • There were no reportable Class 1 Visual examinations.

CLASS 2 (A) VOLUMETRIC EXAMINATIONS

  • There were no reportable Class 2 Volumetric indications.
  • No welds had limited volumetric coverage during UT examination.

(B) SURFACE EXAMINATIONS

  • There were no reportable Class 2 Surface indications.

(C) VISUAL EXAMINATIONS

  • There were no reportable Class 2 Visual indications.

2

ADDITIONAL EXAMINATIONS The following is a summary of additional examinations which were performed during this outage in accordance with the 2001 Edition, 2003 Addenda of ASME Section XIh

  • Class I System Leakage Testing In accordance with IWB-521 0(a), a system leakage test of the Class 1 Reactor Coolant System Pressure Boundary was performed prior to startup following the 26th refueling outage. To meet the requirements of IWA-5242(a), insulation was removed from all insulated Class 1 pressure retaining bolted connections for VT-2 visual examination after the system was depressurized. There was one (1) pressure retaining bolted connection which had minor boron accumulation. There were 11 other minor threaded connections which had some degree of boron accumulation. In each case, the boron was removed and any necessary corrective actions were taken. The results of this testing is also documented in FNP-1-STP-1 56.2 for the Farley 1R26 outage.
  • Class 2 System Leakage Testing In accordance with IWC-5210(a), system leakage testing was performed during the 2 6 th refueling outage on portions of the following systems: Residual Heat Removal, Chemical and Volume Control, Safety Injection, Containment Spray, Steam Generator Blow Down, Main Steam, Main Feedwater, Auxiliary Feedwater, Chemical Injection, and Sample System. There were 36 components with recorded indications (mainly minor packing leaks and end cap leaks and 6 gasket leaks, 2 pump seals, and one casing vent leak) associated with these tests. In each case, necessary corrective action was performed. The results of this testing is documented in FNP-1-STP-156.1.

In addition, the RPV flange leak-off line was examined for the first time after it was learned it had not been pressure tested in accordance with ASME Section Xl. NRC approval for the alternate examinations was granted under FNP-lSl-ALT-16.

  • IWE Examinations During the 1R26 refueling outage, General Visual, VT-3 and VT-i examinations were performed on the applicable Class MC pressure retaining components with their integral attachments and pressure retaining bolting. These examinations were performed in accordance with ASME Section Xl, Subsection IWE of the 2001 Edition through the 2003 Addenda and were performed using NMP-ES-024-207, "General Visual Examination (IWE)", NMP-ES-024-201, "Visual Examination (VT-i)', and NMP-ES-024-203, "Visual Examination (VT-3)".

During the examinations several indications were noted on the liner plate, those conditions consisted of surface rust, scratches, gouges, discolorations, etc. Most of these indications had been identified before in previous examinations but all were evaluated as not affecting the structural integrity or leak tightness of the containment pressure boundary. No corrective actions were required during the 1R26 refueling outage.

In addition, during the 1R26 refueling outage, General Visual examinations were performed on Class MC pressure retaining components with their integral attachments. These examinations were performed in accordance with ASME Section Xl, Subsection IWE of the 2001 Edition through the 2003 Addenda and were performed using NMP-ES-024-207, "General Visual Examination (IWE)"

Additionally, during 2R23 it was discovered that Farley was not meeting the intent of ASME Section Xl, Subsection IWE, specifically Category E-A, Item El1.30. Item El1.30 requires that 100% of the moisture barrier be examined each Inspection Period. It was discovered that Farley had only scoped in the moisture barrier along the outer periphery of containment and did not scope in the moisture barriers that are used in the expansion joints that are located radially around the containment floor between the containment wall, bioshield wall, and reactor vessel shield wall. In addition, the moisture barriers that are located around the bioshield wall and the steam generator and RCP platform were

not scoped scope; into the IWE Program further as well. These review,locations these arewere nowpreviously from however, evaluated to be excluded after internal being included. During 1R26 an examination of the newly identified areas was performed and several locations with degraded or missing moisture barrier were identified. In addition to the expansion joints, an examination of the leak chase test connections (LCTC) was being performed to satisfy IWE moisture barrier

'examinations that were added to the outage in response to IN 2014-07.

The following information has been provided to meet the requirement of 10 CFR 50.55a(b)(2)(ix)(A).

During the examination, several areas of degraded moisture barrier were identified. Levels of degradation varied from portions of the moisture barrier missing completely, cracking of the moisture barrier, and lack of adhesion to the concrete surface. In the areas with the missing sealant, the 1/2" compressible material below the sealant was still in place. Much of the sealant was still pliable to touch and still adhered to either side of the joint, but at the locations of degraded sealant, it was easily pushed down or pulled away. At four locations of missing sealant throughout containment, standing water was found at varying depths with dirt/sludge material at the bottom with two having depth to obtain chemistry samples. These locations were both inside and outside the bioshield wall at expansion joints in the floor and at the floor-to-wall expansion joint (not including the periphery of containment). Based on investigation into the issue, it was ultimately concluded that all the.

expansion joints had some level of moisture in them.

Because several sections of the moisture barrier are degraded and limit access to the liner, the method used to support the evaluation is to sample accessible areas to evaluate the overall integrity of the liner plate beneath the fill slab on the 104'-0" elevation. During the examination of the LCTCs, in which the covers for the LCTCs were removed to look at the pipe cap to pipe connection (moisture barrier), liquid was discovered in two of the recessed portions of the LCTC (4 & 23). Two LCTC's pipes and pipe caps were completely corroded through (10 & 52). After all initial examinations were performed, the conditions were assessed. Further investigation into the LCTC, resulted in the removal of the pipe cap on 47 locations of which 31 locations were noted to have varying levels of moisture in them; the remaining locations were noted as being dry. A videoprobe was utilized to look inside the LCTCs that had their pipe caps removed.

The degradation to the moisture barriers are believed to be a result of exclusion from the IWE scope when the program was developed in the 1998 to 1999 timeframe. Without inclusion into the program, examinations were not performed thus permitting degradation to occur without the additional chances to identify it. Degradation of the moisture barrier for the LCTC is also believed to be attributed to contact with moisture from spill events, equipment leakage, and other miscellaneous items which would present an opportunity for moisture to intrude upon the LCTC covers and gaskets.

The degradation of the sealant utilized as the moisture barrier is more so attributed to lack of attention and time. Like most sealant materials they have the potential to degrade over time and without identification of areas that are degrading to be repaired or replaced, conditions are likely to further degrade. For the most part, liquid in contact with the inaccessible portion of the liner plate in the expansion joints is believed to have gotten there through a degraded drain trench used as a drain path to the containment sumps. The drain trench has expansion joints from the placing of'the concrete floor slab and the sealant in those joints was degraded as well.

Due to the conditions identified and challenges presented to gain access to the inaccessible_ portions of the liner plate ih order to assure that the integrity of the liner plate has been maintained, the evaluation consists of both qualitative and quantitative data. The quantitative data came from UT thickness measurements taken in various areas, while the qualitative information would come from chemistry analysis of the liquid, previous Integrated Leak Rate Test (ILRT) results, design of the drain trench to help understand how liquid moved around, the potential sources for the liquid, the potential for future corrosion and what the design function is of the inaccessible liner and what thickness is required to continue to meet that design function. The conclusion drawn was that the liner plate has maintained its ability to perform its specified design function, which was based on the following summarization of the evaluation.

-The UT thickness measurements for the three locations were taken in areas where degradation would be expected to be seen and the results of those examinations indicate that no appreciable loss of liner plate thickness has occurred.

-In 2009, an ILRT was performed on the containment structure and the results of that test showed that the containment structure was performing its specified design function as well.

- The qualitative visual inspections performed did not show any significant degradation of the liner plate directly below the test connections, which would have expected to be observed.

- Rate of corrosion for one outage is minimal, 0.0022 in/yr.

- Design analysis supports a minimal thickness of 1/32" for the liner plate under the fill slab.

- Observations performed during the investigation process, and during and after the repair to the trench support the conclusion that the liquid seen occurs during the refueling outage, which aids to the expectation that minimal, if any corrosion would occur during the operation cycle.

- Examination results indicate that no appreciable corrosion has occurred since the last ILRT in 2009, so there is no reason to expect the liner plate has degraded to a point in which it can no longer perform its intended design function since the 2009 ILRT.

Definitive corrective actions have yet to be fully vetted, however necessary actions will be taken to ensure that prior to repiacement of the degraded sections of the moisture barrier the inaccessible portion of the liner plate will be verified to not be susceptible to a corrosive environment. In addition the inaccessible portions of the liner plate below the leak chase test connections will be inspected to ensure that the potential for corrosion has been removed.

It is realized by SNC that in order to fully address the issue with the degraded moisture barrier, including the leak chase test connections that it will take more than one outage to resolve the issue and significant planning will need to take place to ensure the corrosive environment has been removed. The development of a corrective action plan will be presented to the Plant Health Committee for approval. The need for the development of a corrective action plan has been entered into the Farley CAP for tracking and documentation as CR 10025966.

  • IWL Examinations No IWL examinations were performed during this reporting period.

STATUS OF EXAMINATIONS REQUIRED FOR CURRENT INTERVAL The 1R26 Outage was the 1 st Outage in the 3 rd Period of the 4 th Interval. The results from this outage, combined with the "completed" examinations from the following refueling outage 1R27 (Fall 2016) will represent 100% of the total Class 1 and 2 scope for the third period of the fourth interval.

Farley Unit 1 is within ASME Code compliance, pending NRC approval of the volumetric and/or surface examination limitations. Requests for relief will be submitted within the required time frame specified by 10 CFR 50.55a. See Table 1 for completion percentages.

As a note, Farley received approval to implement EPRI Risk-Based ISI (RISB) starting in the 2 na Period of the 4 th Interval. Approval was documented in a NRC Safety Evaluation on January 18, 2012 (ADAMS Number ML12012A135). Farley's ISI Plan Documents have been revised to reflect such implementation for Section Xl Examination Categories B-F, B-J, C-F-i, and C-F-2 and as a result the "Total Exams Required During 4 th Interval" will reflect what the requirements were at the beginning of the interval and the "% of Total Exams Completed for Interval" will reflect the completion percentage for the First Period.

  • Applicable Code Cases The applicable Code Cases for the 1R26 Outage included:

N-460 N-648 N-663 N-695 N-696 N-700 N-706 N-722 N-729 5

Table 1 Farley Unit I - 1R26 Outage

________ ~Completion Percentages__________________

Code Percent of Population Total Exams _____________..R2 Ca. te Cae/ N. Poultin eqirdTo Be Required During *No. of Exams  % of Total Exams Ca.tte N.,CaetePpuaton ReuiedCompleted for

. ,ALT 'Examined 4t ItrvlCompleted Inera B-A B1.11 3 100% 3 0 0%

B-A B1.12 4 100% 4 0 0%

B-A B1.21 2 100% 2 0 0%

B-A 81.22 6 100% 6 0 0%

B-A Bl.30 1 100% 1 0 0%

Total: 10 10 0 0%

B-B B2.11 2 100% 2 0 50%

B-B B2.12 2 100% 2 0 50%

B-B B2.40 3 33.33% 1 0 100%

Total: 7 5 0 60%

B-D B3.100 N-648-1 6 100% 6 0 0%

8-0 B3.110 6 100% 6 0 84%

B-D 83.120 6 100% 6 0 84%

B-0 83.140 6 100% 6 0 34%

8-0 83.90 6 100% 6 0 0%

Total: 30 30 0 40%

B-F 85.70 N-6 '6 100% 6 016.6%

__________ ALT-12 Total: 6 6 16.6%

B-G-1 86.10 1 0%1 0 100%

B-G-1 86.180 3 33%1 0 100%

B-G-1 86.190 3 %0 0 0%

B-G-1 B6.20 1 0%1 0 100%

B-G-1 86.40 1 0%1 0 0%

B-G-1 B6.50 1 0%1 0 100%

Total: 105 0 80%

8-G-2 87.20 10% 0 00%

6

Table 1 Farley Unit I - 1R26 Outage Completion Percentages Code P ercent of Population "Total Ex=amsIR6 Cat. Item No. Case I Population Required To Be Required During No. of Exams % of Total Exams ALT Examined,  ; 4 t~hInterval- Completed Copee-o

" " *, *,. * " ...

  • Interval, B-G-2 87.30 6 0% 0 0 0%

B-G-2 87.50 9 33.33% 2 0 100%

B-G-2 B7.60 3 0% 0 0 0%

B-G-2 87.70 24 25% 1 0 100%

    • Total: 43 3 0 334%

8-J 89.11 360 25% 90 0 20%

B-J 89.21 55 25% 14 0 36%

B-J 89.31 N-6/14 25% 4 0 0%

ALT- 12 B-J B9.32 24 25% 6 0 33%

B-J B9.40 244 25% 61 0 13%

Total: 697 175 0 18.8%

B-K B10.10 1 100% 1 0 100%

B-K B10.10(R) N-700 3 33.33% 1 0 100%

B-K B10.20 371%4 0 50%

Total: 416 0 66.6%

B-L-2 B12.20 3 %0 0 0 Total: 30 0 0 B-M-2 B12.50(1) 42%1 0 100%

B-M-2 B12.50(2) 6 %0 0 0 B-M-2 B12.50(3) 5__________0 0 0 8-M-2 B12.50(4) 3

______000 0%

B-M-2 812.50(5) 6

______000 0%

Total: 241010 B-N-i 813.10 1 0%306.%

Total: I306.%

B-N-2 813.60 4100% 4%

7

Table 1 Farley Unit I - 1R26 Outage Completion Percentages Code Percent of Population Total Exams I1R26 Cat. Item No. Case I Population Required To Be Required NofEas Cuig

%ompleted form ALT .Examined 4 th Interval ComletdlIted fal Total: 440 0%

B-N-3 B13.70 1 100% 1 0 0%

Total: 1 1 0 0%

B-0 B14.10(1) 38 18.3% 7 0 0%

Total: 38 7 0 0%

C-A C1.20 3 33.33% 1 0 0 C-A 01.30 3333%100%

Total: 6205%

C-B 02.21 3 3.3 C-B C2.22 3333%100%

Total: 6205%

C-C 03.10 6 16.66% 100 C-C C3.20 N-700 210 1.%22 6 91%

C-C C3.30 121%2 2 100%

Total: 2825 8 88%

C-F-i 05.11 87 .%66 0 10%

C-F-i 05.21 N-663 / 0 75 31 0 3.2%

C-F-i 05.30 ALT-12 338 7.%26 0 50%

C-F-I 05.41 17.%2 0 50%

Total: 148-125 0 16.8%

C-F-2 05.51 201.%25 0 20%

N-663 /

C-F-2 05.60 12T12

_8.33%______1 0 0%

C-F-2 05.81 2483%2 0 50%

Total: 2628 0 21.4%

D-A 01.10 N-700 944%2100%

8

Table I Farley Unit I - 1R26 Outage

________Completion Percentages Code Percent of Population Total Exams 12 Ca. o.tm Cse/ oultin Required To Be Required During *No.,of Exams  % of Total Exams ALT Examined 4 th interval Competedintedrfal 0-A 01.20 256 11.5% 34 9 84%

Total: 265 38 11 86%

F-A F1,10A(1) 7 25% 2 0 50%

F-A F1.10B(1) 57 26% 15 0 63%

F-A F1.10C(1) 32 25% 8 0 75%

F-A F1.10D(1) 65 27% 18 1 78%

F-A F1.10E(1) 41 24% 10 0 70%

F-A F1.10F(1) 1 0% 0 0 0%

F-A F1.10S(1) 55 27% 15 4 124%

F-A F1.20A(1 ) 63 15% 10 4 90%

F-A F1.20B(1) _____ 139 14% 20 7 105%

F-A F1.20C(1) 17 28% 5 2 84%

F-A F1.20D(1) 138 15.7% 22 8 96%

F-A F1.20E(1) 81 15% 13 4 100%

F-A F1.20F(1) 27 14.8% 4 0 75%

F-A F1.20G(1) 14 20% 3 0 100%

F-A F1.20S(1) 53 16.9% 9 8 200%

F-A F1.30A(1) 75 9.5% 8 1 84%

F-A F1.30B(1) 127 9.8% 13 1 82%

F-A F1.30C(1) 5 20% 1 0 100%

F-A Fl1.300(1) 332 10.7% 36 2 77%

F-A F1.30E(1) 119 12.5% 15 1 87%

F-A F1.30F(1) 111 10.6% 12 4 100%

F-A Fl.30H(1) 31 9.5% 3 1 67%

F-A F1.30S(1) 9 21% 2 1 100%

F-A Fl1.40(1) 72 45.5% 33 10 76%

Total: 1671 277 59 88%

R-A R1.11 ALT-12 171 21 7 66.7 9

Table 1 Farley Unit I - 1R26 Outage Completion Percentacies Percent of Population 1R26 Code Total Exams Cat. Item No. Case / Required To Be Required During  % of Total Exams Population Examined th Interval No. of Exams completed for ALT 4 Completed-Interval R-A R1.11H ALT-12 57 3 0 100%

R-A R1.16 ALT-12 9 2 0 100%

R-A R1.11/16 ALT-12 7 0 0 0%

R-A R1.20 ALT-12 615 27 14 77.8%

R-A R1.20BER ALT-12 199 16 0 81.3%

Total: 69 76.5%

  • THE COMPLETION PERCENTAGE FOR THIS Examination Category, B-G-2, is above the 100% completion percentage due to the way these exams are counted in the ISI Program. This is due to Exam Category B-G-2 exams being performed on components as they are disassembled instead of scheduling examinations ahead of time. Program requirements for this Examination Category are being met.

Note:

Categories B-F, B-J, C-F-i, C-F-2 and R-A are or have been affected by NRC approval of FNP-ISI-ALT-12, which allowed the implementation of Risk Informed Inservice Inspections. Due to the utilization of Risk-Informed the completion percentages for B-F, B-J, C-F-i, and C-F-2 will only reflect one Period of exams being completed for the entire Interval. Category R-A exams will account for two Periods of examinations, however, completion percentage will reflect as if the two Periods made up the interval instead of the normal three Periods.

10

TAB C EXAMINATION PROGRAM PLAN

Farley Unit 1 Class 1 Cornponents ASME ExamintoIxmCaI Seto IExamination/A rea ExaminatReaion Seto lProcedure(s) Sheet No(s). ReutRmak N-722 ALA1 -1100C-BMI-BMV B1.0 RPV BOTTOM HEAD MOUNTED NMP-ES-024-208 NA Sat N/A B15.80 INSTRUMENTATION BMV N-729 ALA1 -1300-UPPER HEAD-VOL WDI-PJF-B.0 REPLACEMENT RPV CLOSURE HEAD CRDM VENDOR 131 3702-FRS- Sat N/A B.0 EXAMINATIONS 001 N-722 ALA1 -41 00-1 DM-BMV NM-S0422N a o e B15.90 RPV HOT LEG SAFE END BMVNM-S0422ASa HoLe R-A ALAI-4103-10-RB NMP-ES-024-501 S15F1U075 NRI N/A R1.20(1) PIPE TO ELBOW R-A ALA1-4103-l11-RB NMP-ES-024-501 S15F1 U076 NRI N/A R1.20(1) ELBOW TO PIPE R-A ALA1-4103-12-RB NMP-ES-024-501 S15F1U077 NRI N/A Ri1.20(1) PIPE TO ELBOW R-A ALA1-4103-13-RB NMP-ES-024-501 S15F1U078 NRI N/A RI1.20(1) ELBOW TO PIPE R-A ALA1-4103-14-RB NMP-ES-024-501 S15F1U079 NRI N/A Ri1.20(1) PIPE TO ELBOW_________________

R-A ALAI-4103-9-RB NMP-ES-024-501 S15FIU074 NRI N/A RI1.20(1) ELBOW TO PIPE R-A ALA1-4108-14BW-RB NMP-ES-024-501 S15F1U097 NRI 50% Code Coverage. Relief Request Ri1.20(1) TEE TO PIPE required.

N-722 ALA1 -4200-1 DM-BMVNM-S0422ASa HoLe B1 5.90 RPV HOT LEG SAFE END BMVNMES0422ASa HoLe R-A ALA1-4201-8-RB NMP-ES-024-501 S15FiU001 NRI N/A R1.20(1) ELBOW TO PIPE R-A ALA1-4201-9-RB NMP-ES-024-501 S15F1U002 NRI N/A RI1.20(1) PIPE TO ELBOW F-A ALA1 -4203-SI-RI178 NPE-2-0 1FV7 a /

Fl .10D(1) TWO DIRECTIONAL RESTRAINT NPE-2-0 i5iV7 a /

N-722 ALA1-4300-1DM-BMVNM-S0422ASa HoLe B15.90 RPV HOT LEG SAFE END BMVNME-0422ASa HoLe R-A ALA1-4302-11-RB NMP-ES-024-501 S15FIU090 NRI N/A RI1.20(1 ) ELBOW TO PIPE R-A ALAI-4302-12-RB NMP-ES-024-501 S15F1UO9i NRI N/A RI1.20(1) PIPE TO ELBOW R-A ALA1-4302-2-RB NMP-ES-024-501 S15F1U080 NRI N/A Ri.20(1 ) ELBOW TO PIPE

Farley Unit 1

________ ~~~~~~Class 1 Cornponents______________

ASMEcin Examination/Area Examination Ea/a eut eak Seto lProcedure(s) Sheet No(s). ReutRmak R-A ALA1-4302-3-RB NMP-ES-024-501 S15F1U08i NRI N/A Ri1.20(1 ) PIPE TO ELBOW R-A ALA1-4302-4-RB NMP-ES-024-501 S15F1U092 NRI N/A R1.20(1) ELBOW TO PIPE F-A ALA1-4302-SI-R129 NMP-ES-024-203 S15F1V042 Accept N/A FI.S10S1 HYDRAULIC SNUBBER R-A ALA1-4303-3-RB NMP-ES-024-501 S15F1U070 NRI N/A R1.1i(1) ELBOW TO PIPE R-A ALA1 -4303-4-RB NMP-ES-024-501 S15F1U069 NRI N/A R1.11(1) PIPE TO ELBOW R-A ALAI-4303-5-RB NMP-ES-024-501 S15F1U071 NRI N/A R1.1i(1) ELBOW TO PIPE R-A ALA1-4303-6-RB NMP-ES-024-501 S15F1U072 NRI N/A R1.1i(1) PIPE TO ELBOW R-A ALA1-4304-18-RB NMP-ES-024-501 S15F1U066 NRI N/A R1.11(1) ELBOW TO PIPE R-A ALA1-4304-19-RB NMP-ES-024-501 S15F1U067 NRI N/A Ri.11(1) PIPE TO ELBOW F-A ALA1-4307-SS-4103 NMP-ES-024-203 S15F1V053 Accept N/A Fl. 10S(1) HYDRAULIC SNUBBER F-A ALA1-4502-RC-R219 NMP-ES-024-203 515FIV061 Accept N/A Fi.1S(1) HYDRAULIC SNUBBER F-A ALA1-4503-RC-R226 N MP-ES-024-203 $15FIV072 Accept N/A Fi.S 10S1 HYDRAULIC SNUBBER F-A QIF13D001NP-S04-0O15107 a /

Fi.40(1) CRDM SEISMIC SUPPORT PLATFORM NPE-2-0 1FV6 a /

F-A QIFI3D0002 NPE-2-0 1FV6 a /

Fl1.40(1) CRDM SEISMIC SUPPORT TIE ROD NPE-2-0 i5iV6 a /

F-A QIFI 3DOOO3 CRDM SEISMIC SUPPORT VERTICAL NMP-ES-024-203 S15F1V069 Sat N/A F1 .40(i) LIFTINGLEGS_____________________________

2

Farley Unit 1 Class 2 Components ASME Examination Exam/Cal Section Xl ExaminationlArea Procedure(s) Sheet No(s). Results Remarks F-A ALA2-4101-MS-R1 33 NMP-ES-024-203 S15F1V005 Sat N/A F1.20E(1) SWAY STRUT (2)________

C-C ALA2-4502-SI-R291 (W)NMP-ES-024-301 S15FIP007 NRI N/A 03.20 WELDED ATTACHMENT S15F1P008 C-C ALA2-4504-RHR-R98X (W8) NMP-ES-024-301 $15F1P005 NRI N/A C3.20 WELDED ATTACHMENT F-A ALA2-4504-RHR-R98XANM-S0423 S5V01 Acp NA F1.20S(1) HYDRAULICSNUBBER W/ATTACHNM--0-23 SF1OI Acp N/

F-A ALA2-4504-RHR-R98XBNM-S0423 15V02 Acp N/

F1.20(1) HYDRAULIC SNUBBER W/ATTACHNM-S0423 1FV02 Acp N/

C-C ALA2-4506-RHR10-R21 (W4) NMP-ES-024-301 S15F1P004 NRI N/A C3.20 WELDED ATTACHMENT F-A ALA2-4506-RHR10-.R21 NPE-2-0 1FV0 a /

F1 .20D(1) TWO DIRECTIONAL RESTRAINT W/ATTACHNM--0-23 S5FV6 Sa N/

F-A ALA2-4509-CVC-R326 NPE-2-0 1FV0 a /

F1 .20D(1) TWo DIRECTIONAL RESTRAINTNME-0423 S5FV7 Sa N/

C-C ALA2-4511-CMC-R15 (W6) N MP-ES-024-301 S15F1P006 NRI N/A 03.20 WELDED ATTACHMENT F-A ALA2-4511I-CVC-R1 5 NPE-2-0 1FV7 a /

F1.20D(1) TWo DIRECTIONAL RESTRAINT W/ATTACH NPE-2-0 1FV7 a /

F-A ALA2-4513-CVC-R40 NMP-ES-024-203 S15F1V009 Sat N/A Fl .20B(1) ONE DIRECTIONAL RESTRAINT F-A ALA2-4513-CVCS-A22 NMP-ES-024-203 $I5F1VOO8 Sat N/A Fl1.20A(1) ANCHOR W/ATTACH C-C ALA2-4514-SI-R87 (W8) NMP-ES-024-301 $15F1 PO01 NRI N/A 03.20 WELDED ATTACHMENT F-A ALA2-451 4-SI-R87 NPE-2-0 1FV1 a /

F1.20B(1) ONE DIRECTIONAL RESTRAINT W/ATTACH NPE-2-0 1FV1 a /

F-A ALA2-4517-RH R8-R52 N MP-ES-024-203 $15F1V011 Sat N/A Fl1.20E(1 )SWAY STRUT F-A ALA2-451 7-SIl-R99 NPE-2-0 1FV1 a /

Fl1.20B(1) ONE DIRECTIONAL RESTRAINT NPE-2-0 15IO a /

F-A ALA2-451 8-S l-R23 NPE-2-0 1FV1 a /

Fl1.20B(1) ONE DIRECTIONAL RESTRAINT W/ATTACHNM-S0423 15FVl3 Sa N/

C-C ALA2-4533-CVC-RS0 (WS) N MP-ES-024-301 S$15F1 P011 NRI N/A 03.20 WELDED ATTACHMENT F-A ALA2-4533-CVC-R80 NPE-2-0 1FV1 a /

Fl1.20D(1) TWO DIRECTIONAL RESTRAINT W/ATTACHNM-S0-23 15FVl4 Sa N/

3

.:* . . . . " *,*. ~Farley U nitlI ! ~ * " ,. . . .. ... .. . .

ASM i "~aiainAe"Examination *-Exam/Cal *- ..

Section XI Examinaionl-re ProcedUre(s), SheetNo s)."Results;
*,, ,- 'Remar~ks "

F-A ALA2-4537-SS-2058 NMP-ES-024-203 S15F1V015 Sat N/A F1 .20A(1) ANCHOR 2 U-BOLTS F-A ALA2-4538-SS-2061 NMP-ES-024-203 SI5FIV016 Sat N/A FI.20A(1) ANCHOR F-A ALA2-4604-SI-R2 NPE-2-0 1FV1 a /

Fl.20D(1) TWO DIRECTIONAL RESTRAINT NPE-2-0 IFVI a /

F-A ALA2-4615-SS-4001 NMP-ES-024-203 S15F1V058 Sat N/A Fl1.20D(1) TWo DIRECTIONAL RESTRAINT F-A ALA2-461 5-SS-4008NM-S0423 15V59 Sa N/

F1.20B(l) ONE DIRECTIONAL RESTRAINT NPE-2-0 IFV5 a /

F-A ALA2-4623-SS-1975A NMP-ES-024-203 S15F1V043 Accept N/A Fl1.20S(1) HYDRAULIC SNUBBER___________________________

F-A ALA2-4623-SS-1975B NMP-ES-024-203 S15FIV044 Accept N/A F1.20S(1) HYDRAULIC SNUBBER ___________________

F-A ALA2-4623-SS-1975C NMP-ES-024-203 S15FIV047 Unsat AceR-0tbeA-IS0034.

FI.20C(1) SPRING CAN AcceptableAS-IS F-A ALA2-4623-SS-1975D NMP-ES-024-203 S15F1V048 Accept N/A Fl1.20S(1) HYDRAULIC SNUBBER_____________

F-A ALA2-4627-.SS-1980 NMP-ES-024-203 S15F1V049 Sat N/A F1 .20A(l) ANCHOR 2 U-BOLTS F-A ALA2-4631-SI-R59 NMP-ES-024-203 S15F1V019 Unsat IER-003 -CR 10046437.

F1.20E(1) SWAY STRUT _____________Acceptable AS-IS.

F-A ALA2-4631 -SI-R64 NMP-ES-024-203 S$15FI V020 Sat N/A Fl1.20B(l) ONE DIRECTIONAL RESTRAINT F-A ALA2-4632-SI-R68 NPS-2-0 S1F04 Acet IER-002 - CR 10046426.

F1 .20S(1) HYDRAULIC SNUBBER NM-S0423 55104 Acp Visually degraded, tested SAT.

F-A ALA2-4636-SS-1 987NM-S0423 15V50at N/

Fl1.200(1) TWO DIRECTIONAL RESTRAINT NPE-2-0 1FV5 a /

F-A ALA2-47O1-CS-R297 'NMP-ES-024-203 $15F1V021 Sat N/A Fl .20E(1) SWAY STRUT F-A ALA2-4704-CS-BR100 NMP-ES-024-203 $15F1V022 Sat N/A F1 .20C(1) SPRING CAN_____________

F-A ALA2-4705-CS4-R8 NPE-2-0 1FV2 a /

F1.20D(l) TWO DIRECTIONAL RESTRAINT NPE-2-0 1FV2 a /

F-A ALA2-4707-CS-R142ANM-S0423 15V51 Acp N/

F1.20S(1) HYDRAULIC SNUBBER W/ATTACHNM-S0423 1FV51 Acp N/

F-A ALA2-4707-CS-R1 42B NPE-2-0 1FV5 cet Vsal erdd etdST Fl.20S(l) HYDRAULIC SNUBBER W/ATTACH NPE-2-0 1FV5 cet Vsal erdd etdST 4

  • ASME* xmnto/ra Examination , *:ExamICal, " Results 'r" iR-"*.

emarKs

    • r*' .

Section XI Exa.. .inlre. Procedure(s)*' Sheet No~s). ,-..., . ...

F-A ALA2-4708-CS5-RI 7 NPE-2-0 1 V2 a /

Fl.20B(1) ONE DIRECTIONAL RESTRAINT NPE-2-0 1FV2 a /

C-C ALA2-5120-CS-1 (WI) N MP-ES-024-301 S 15F1P002 NR] N/A C3.30 WELDED ATTACHMENT F-A ALA2-51 20-CS-I M-S0423 S1FV2 a /

Fl.40(1) CENTRIF CHRGING PMP (C) Q1E21P002C NPE-2-0 1FV2 a /

C-C ALA2-5120-CS-2 (WI) NMP-ES-024-301 S15F1PO03 NRI N/A C3.30 WELDED ATTACHMENT F-A ALA2-5120-CS-2 -NPE-2-0 1FV2 a /

Fl1.40 1) CENTRIF CHRGING PMP (C) QIE21PO02CNM--0-23 S5FV6 Sa N/

F-A ALA2-51 20-CS-3 NPE-2-0 1FV2 a /

F1 .40(1) CENTRIF CHRGING PMP (C) Q1E21P002C NPE-2-0 1FV2 a /

F-A ALA2-5120-CS-4 NPE-2-0 1FV2 a /

F1 .40(1) CENTRIF CHRGING PMP (C) QIE21P002C NPE-2-0 IFV2 a /

5

TAB D

SUMMARY

OF RECORDABLE INDICATIONS

SUMMARY

OF RECORDED INDICATIONS 2015 UNIT 1 REFUELING OUTAGE - 1R26 SEC IDITEM INDICATION ACCEPTED PER MNTR IER SEC IDDESCRIPTION DESCRIPTION MNTRNUMBER EVALUATIONREPAIRJREPL ALA2-4632 F-A ALA2.-4632-SI-R68 Vsal erdd 0 ALA2-4632__ F1 .20S(1) Hydraulic Snubber Visuallyderaded._X_ 00 F-A AA-61thread ALA2-4631-SI-R59 Paddleengagement ends have insufficient in barrel X 003 AA-61 F1.20E(1) Sway Strut assembly. ____

F-A ALA2-4623-SS-1 975C Iproper load settings and AA-23rod is misaligned X 004 AA-63 F1.20C(1) Spring Can approximately 15'"____ ____

Degraded and missing 0176201 WE Containment Moisture portions of the moisture -

U165855 Barrier barrier identified duringX

_________ ___________________ examination.

TAB E FORM NIS-2 OWNER'S REPORTS FOR REPAIRS AND REPLACEMENTS

OWNER'S REPORTS FOR REPAIRS OR REPLACEMENTS (FORM NIS-2)

The following Owner's Reports for Repairs or Replacements (Form NIS-2) are provided for work activities documented at FNP-1 since the last maintenance/refueling outage (1R25) through the completion of the twenty-sixth maintenance/refueling outage (1R26). Reports are identified by their respective job number which is denoted on each of the NIS-2 reports. The originals of the NIS-2 reports are filed with their respective packages at the plant site. Only those NIS-2 reports applicable to FNP-1 are included in this report document. Any attachments, e.g., code data reports, etc., referenced in the NIS-2 reports will be made available for review upon request at the plant site.

The NIS-2s for the following job number packages are included herein:

SNC51727 SNC401237 SNC509550 SNC555691 - SNC55571B SNC556283 SNC637465 SNC53666 SNC431379 SNC509578 SNC555692 SNC555721 SNC566968 SNC645570 SNC55180 SNC482146 SNC512081 SNC555693 SNC555723 SNC580719 SNC645669 SNC55186 SNC482608 SNC512082 SNC555707 SNC555726 SNC595300 SNC647950 SNC55187 SNC496768 SNC512253 SNC555708 SNC555727 SNC595307 SNC651188 SNC57187 SNC505849 SNC527228 SNC555709 SNC555733 SNC595865 SNC653114 SNC61572 SNC505856 5NC544347 SNC555710 5NC555746 5NC595867 5NC657815 SNC61575 SNC505860 SNC555657 SNC555711 SNC555748 SNC599493 SNC61576 SNC505862 SNC555661 SNC555713 SNC555759 SNC601311 SNC61578 SNC505863 SNC555666 SNC555716 SNC555760 SNC602640 SNC61580 SNC509544 SNC555675 SNC555717 SNC555761 SNC633702______

SNC401189 SNC509547 SNC555690 SNC555719 SNC555790 SNC637037______

0 FORM NIS-2 OWNER'S REPORT FOR REPAIRJREPLACEMENT ACTIVITY As Required By The Provisions Of The ASME Code Section Xl

1. Owner Southern Nuclear Operating Company Date 6/4/2015 Name 40 Inverness CtrPkwy, Birmingham, AL, 35242 Sheet I of 2 Address
2. Plant Joseph M4.Fauley Nuclear Plant (IFNP) Unit FNPUNIT1 Name 7388 N. State Hwy 95._Columbia, AL 36319 WO#: SNC51727 Address RepairdReplacement Organization P.O. No., Job No., etc.
3. Work Performed by FNP Maintenance Department Type Code Symbol N/A Stamp Name Authorization N/A No.

7388 N. State Hwy. 95, Columbia, AL. 36319 Expiration N/A Date Address

4. Identification of System N3, Auxilary FeedwaterSystern, Q1N23P002, Class 3
5. (a) Applicable Construction Code ASME Sect. III 1971 Edition, Summer 1971 Addenda, N/A Code Case (b) Applicable Edition of Section Xl Used for Repair/Replacement Activity 2001 EDI12003 ADD (c) Applicable Section Xl Code Case(s) N/A 6, Identification Of Components ASERPod National Beard NatAoaE Corrected, Name of Name of Manufacturer Other Year Removed, or

=o

~omponen: iwanuracturer ~enai rio. Board rio. Iaentitlcatlon ~uIIt Installed (YES Stamped or rioj GLAND SEAL ARMCO STEEL 51664 N/A PC: FNP2.35 1975 REMOVED NO PLATE CORP.

(INBOARD) ____________ __________ _______________ ___________

GLAND SEAL FLOWSERVE RLSA 12485-2 N/A P0: QP080493 2008 INSTALLED NO PLATE ___________ __________

7. Description of Work Replace pump glland seal plate due to normal wear.
8. Test Conducted: [J PneumaticC-'

0 Other [] Pressure Hydrostatic _ ___psi NominalTest Operating Temp. Prossure[x-J

____F__ Exempt[]

Page 1 of 2

0 FORM NIS-2 (Back)

9. Remarks Ceriict af-Comface. VT-2 Exam, NPV-1 Form. t-f,4Form Applicable Manufacturer's Data Reports to be attached SNC51727 CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and that this Reolacemen~t conforms to the rules of the ASME Code, Section Xl.

Type Code Symbol Stamp N/A N/A Certificate of Authorization N/ANo. N/A xiainDt Date  :* -- ,f Signed OwerorOwers esgneTil I Owner or Owner's Designee, Thie CERTiFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel inspectors and the state or Province of Florida. and employed by HSB Global.Standards of _ HrfrCT JiitinX.have inspected the components described in this Owner's Report during the period o,/ /-J to__,_____-

S'-aminations and taken corrective i" measures described and statein that to the best this Owner's Reportof inmyaccordance knowledgewithandthebelief, the Owner requirements hasASMVE of the performed Code, By signing examinations this certificate and corrective measuresneither the Inspector described nor his in this Owner's employer Report. makes any Furthermore, warranty, neither expressed the Inspector nor or hisimplied, employerconcerning the shell be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

  • fj4 7 IiZL §--_..* Commissions I2bO3A,*c. *k44-r l-* ilW iii w .... * ...... ... - -- * * -v 6" National Board, State, Province and Endorsements Inspector's Signature Date Page 2 of 2

FORM NIS-2 OWNER'S REPORT FOR REPAIRIREPLACEMENT ACTIVITY AS Required By The Provisions Of The ASME Code Section Xl' 1.Owner Southern Nuclear Operating Company Date 6/22/2015 Name 40 Inverness Ctr Pkwy, Birmingham, AL, 35242 Sheet Iof2 Address

2. Plant Joseph M. Farley NuclearPlant (FNP) Unit FNP UNIT 1 Name 7388 N. State Hwy/ 95, Columbia, AL 36319 WO#: SNC53686 Address Repair/Replacement Organization P.O. No., Job No., etc.
3. Work Performed by FNP Maintenance Department Type Code Symbol N/A Stamp Name Authorization N/A No.

7388 NV.State Hwy. 95, Columbia, AL. 36319 Expiration N/A Date Address

4. Identification of System NIl, Main Steam System, QINi 1V004D, Class 2
5. (a) Applicable Construction Code ASME B&PV Code 1968 Edition, N/A Addenda, N/A Code Case (b) Applicable Edition of Section Xi Used for Repair/Replacement ActIvity 2001 ED:/2003 ADD (c) Applicable Section Xl Code Case(s) N/A
6. Identification Of Components National Corrected, ASME Code Name of Name of Manufacturer Board Other Year Removed, or Stamped Component Manufacturer Serial No. No. Identification Built Installed (Yes or No) 6" GA TE PACIFIC 1021 N/A PO: FNP-190 1974 REMOVED YES VALVE SCIENTIFIC________ ____ ____ _______

6" GATE FLOWSERVE BJ965 N/A P0: QP100320 2011 INSTALLEO YES VALVE _____________ _______ ___

7. Description of Work Valv reo e..de

.. . odvleea

. ino a1 set

8. Test Conducted: Hydrostatic [] PneumaticE'- Nominal Operating Pressurei-i ExemptL-"

Other [] Pressure _____psi Test Temp. _____

Page 1 of 2

FORM NIS-2 (Back)

Certificate of Compliance, NPV-1 Form, VT-2 Exam, Radiographic Inspection Report, Equivalency Determination: C092556601 Rev. 3.0.

SN.SRCm3rk6 Applicable Manufacturer's Data Reports to be attached SNCSNC53666 CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and that this. Replacement conforms to the rules of the ASME Code, Sect~ion Xl.

Type Code Symbol Stamp WA Certificate of Authorization N/A Expiration Date N/A No.

Signed

  • j /A4JIJg LAW. It:~~, Date I I I I Owner or Owner's Designee, Title CERTIFICATE OFINSERVICE INSPECTiON I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the state or Province of Flordda and employed by HSB Global Standards .of HrfdCT have Inspected the components described in this Owner's Report during the period o/_l'zt to t* D*/7.o and state that to the best of my knowledge and belief, the owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section Xl.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

  • .* eJVJ *7 (QP *, Commissions *.7OJIC *'.-'"-

Inspector's Signature National Board, State, Province and Endorsements Date .0 , Zb(Oil*

Page 2 of 2

FORM NIS-2 OWNER'S REPORT FOR REPAIR/REPLACEMENT ACTIVITY As Required By The Provisions Of The ASME Code Section XI

1. Owner Southern Nuclear Operatinq Company Date 6/15/2015 Name 40 Inverness Ctr Pkwy, Birminaham, AL, 35242 Sheet 1of 2 Address
2. Plant Joseph MA.Farley Nuclear Plant(FNP) Unit FNPUNIT 1 Name 7388 N. State Hwy 95. Columbia, AL 36319 WO#: SNC55180 Address Repair/Replacement Organization P.O. No., Jab No., etc.
3. Work Performed by FNP MaintenanceDepartment Type Code Symbol N/A Stamp Name ' ~Authorization N/A No.

7388 N. State Hwy. 95, Columbia, AL. 36319 Expiration N/A Date Address

4. Identification of System Eli. Residual Heat Removal, Q1El11HO00 IA, Class 2
5. (a) Applicable Construction Code ASME Sect. IIl 1971 Edition, Summer 1971 Addenda, N/A Code Case (b) Applicable Edition of Section Xl Used for Repair/Replacement Activity 2001 ED/12003 ADD (c) Applicable Section Xl Code Case(s) N/A
6. Identification Of Components National corrected, ASME Code Name of Name of Manufacturer Board Other Year Removed, or Stamped Cmoet Manufacturer Serial No. No. Identification Built Installed IYes or No) 1" STUDS (3) UNK UNK N/A UNK UNK REMOVED NO AND NUTS (6) _____ ___ ____

1" STUDS (3) NOVA N/A N/A HT: 229173 2010 INSTALLED NO 1" HEX(NUTS NOVA N/A N/A HT. 871132 2005 INSTALLED NO (6) _________ PO: QP100611

7. Description of Work Replaced bolting due to corrosion.
8. Test Conducted:

Other El El Hydrostatic Pressure Pneumatic E--

____psi NominalTest Operating Temp. Pressurel-J ExemptE[

Page 1 of 2

FORM NIS-2 (Back)

Certificate of Compliance, VT-2 Exam, Piping Specification: SS-1 109-02, Appendix A Table 19 NRemark Applicable Manufacturer's Data Reports to be attached 9.

SNC551 80 CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and that this Replacement conforms to the rules of the ASME Code,Section XI.

Type Code Symbol Stamp N/A Certificate of Authorization N/A Expiration Date No. N/A Signed Date Owner or Owner's Designee, Title CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the state or Province of Florida and employed by HSB Global Standards of Hrod.CT ,-

have inspected the components described in this Owner's Report during the period /'/ -

  • ____ to_7_,/-t' and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code,Section XI.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected With this inspection.

-*b*.= -IIkr*

  • Commissions I2-t6,5i>j*, e.., r'i-445, National Board, State, Province and Endorsements Date O-//zt20 *>

Page 2 of 2

FORM NIS-2 OWNER'S REPORT FOR REPAIRIREPLACEMENT ACTIVITY As Required By The Provisions Of The ASME Code Section XI 0 1. Owner Southern Nuclear Operating Company 4E kwemess C* Pkwv*,

Name m AL~q

,35242 Date:

Sheet 5/1/2015 1 of2 Address Unit FNP Unit I WO# SNC 55186

2. Plant Joseph M. FarleyNuclear Plant(FNP) Repair/Replacement Organization P.O. No., Job No., etc.

Name 7388 N. State Hwy 95. Columbia,AL 36319 Type Code Symbol Stamp N/A Address Authorization No. N/A

3. Work Performed By Expiration Date N/A Williams PlantServices Name 7388 N. State Hwy 95. Columbia, Al. 36319 Address
4. Identification of System E11. Residual Heat Removal/Low HeadSafety Injection. QIE11-ECB-13 (South Flange. Drop Out Sp~ool).

Class 2 S. (a) Ap~plicabie Construction Code 1971 Edition, Summer 1971 Addenda, N/A Code Case (b) Applicable Edition of Section XIUsed for Repair/Replacement Activity 2001 Edition. 2003 Addendo (c) Applicable Section XI Code Case(s) N/A

6. Identification of Components___________

National ASME Code Name of Name of Manufacturer Board Year Corrected, Removed, Stamped (Yes or Component Manufacturer Serial No. No. Other Identification Built or Instalied No) 1-1/8" Stud Unknown Unknown N/A Unknown Uink Removed No (20) _______ ____

1-i /8" Nut Unknown Unknown N/A Unknown Unk Removed No 0 (40) _______ ____ __________

1-1/8" Stud Nova NF12I02435 N/A SNA10066065 2013 Installed No (8) _____________ ___________

1-1/8" Stud Nova 3005167 N/A QP100720 2010 Installed Na (12) ______________________

1-1/8" Nut Nova 3012026 N/A QP110243 2011 Installed Na 1-1/8" Nut Nova 223422 N/A QP100618 2010 Installed No (8) _______ ___________

7. Description of Work S. Test Conducted: Pneumatic LI Lii Other El Hydrostatic []

Pressure _______psi Nominal Operating Pressure []

Test Temp. _____F___

Exempt 0

FORM NIS-2 (Back)

9. Remarks Certificatesof Conformance. CertifiedMaterial Test Reports, VT-2 Examination Applicable Manufacturer's Data Reports to be attached 0 WO# $NC $$186 CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and that this replacement conforms to the rules of the ASME Code, section Xl. repair or replacement Type Code Symbol Stamp N/A Cetfce NAExpiration Date N/A Owner or Owner's Designee CERTIFICATE OF INSER VICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the state or Province of Florida and employed by HSS Global Standards of , hartford. CT have inspected the components described in this Owner's Report during the period e*--/* (* / Zo *5 .

to e>*'"/z*/'7J-ole- , and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section Xl.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer SHALL 0

be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

Inspector's Signatui(* National Board, State, Province and Endorsements Date "/ / l '

0

FORM NIS-2 OWNER'S REPORT FOR REPAIRIREPLACEMENT ACTIVITY As Required By The Provisions Of The ASME Code Section XI

1. Owner Date: 5/112015 0 Name Sheet 1 of 2 Address Unit FNP* Unit t
2. Plant WO# SNC 55187 Joseph M. FarleyNuclear Plant (FNP) Repair/Replacement Organization P.O. No., Job No., etc.

Name 7358 N. State Hwy 95. Columbia, AL 36319 Type Code Symbol Stamp N/A Address Authorization No. N/A

3. Work Performed By Expiration Date N/A Williams Plant Services Name 7388 N. State Hwy 95. Columbia, AL 36319 Address
4. Identification of System Ell. Residual Heat Removal/Low Head Safety Injection. QIE11-ECB-13 (North Flanqe. DropOut Spool).

Class 2 S. (a) Appllcable Construction Code 1971 Edition, Summer 1971 Addenda, N/A Code Case (b) Applicable Edition of Section Xl Used for Repair/Replacement Activity 2001 EdItion. 2003 Addenda (c) Applicable Section XI Code Case(s) N/A

6. identification of Components ____________

National ASME Code Name of Name of Manufacturer Board Year Corrected, Removed, Stamped (Yes or Component Manufacturer Serial No. No. Other Identification Built or Installed No) 1-1/8" Stud Unknown Unknown N/A Unknown Link Removed No (20) _______

1-1/8" Nut Unknown Unknown N/A Unknown Link Removed No 0 (40) _____ __________ _______

1-1/8" Stud Nova 3005167 N/A 0P100720 2010 Installed No (20) 1-1/8" Nut Nova 223422 N/A QP1OO618 2010 Installed No (40) ________ ___________________

7. Description of Work Replaced studs and nuts on removable soool piece due to insufficlent threadengogement durina gasket replacement.
8. Test Conducted: Hydrostatic I] Pneumatic Q] Nominal Operating Pressure [] Exempt LI Other [] Pressure _______psi Test Temp. _____F___

0

FORM NIS-2 (Back)

9. Remarks .Certificates of Conformance, Certified Materialrest Reports. VT-2 Examination C 7)

WSNC 5187Applicable Manufacturer's Data Reports to be attached CERTIFICATE OF COMPLIANCE ient conforms to the rules of the We certify that the statements made in the report are correct and that this replacetr ASME Code, Section Xl. repair or rep )lacement Type Code Symbol Stamp N/A N/A

Owner or Owner's Designee CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boi!ler and Pressure Vessel Inspectors and the state or Province of Florida and employed by HSB Global Standards -of .- arfd CT have inspecte¶I thejcmponents described in this Owner's Report during the period to Oid/ci / Zc * , and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requ lirements of the ASME Code, Section Xl.

By signing this certificate neither the Inspector nor his employer makes any warren ity, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neithiier the Inspector nor his employer SHALL

(> be liable in any manner for any personal iniury or property damage or a loss of any kind arisi ing from or connected with this inspection.

"-eJ*A--y *,4 *-r'*~------------- Comm isions ' 1 3/I t*C Inspector's Signature National Board, State, Province and Endorsements Date &0O* Z. It' 0

FORM NIS-2 OWNER'S REPORT FOR REPAIR/REPLACEMENT ACTIVITY AS Required By The Provisions Of The ASME Code Section XI

1. Owner Southern Nuclear Op~erating Company Date: .. 5/4/2015 Name Sheet 1 of 2 40 Inverness CtrPkwvt Birninqham,A4135242 Unit FNP Unit 1 Address
2. Plant Joseoh M. FarleyNuclear Plant(FNP)

WO# SNC 57187 RepaIr/Replacement OrganIzatIon P.O. No., Job No., etc.

Name 7388 N. State Hwy 95. Columbia. Al. 36319 Type Code Symbol Stamp N/A Address Authorization No. N/A

3. Work Performed By Expiration Date N/A .

FNP Mainten#ance..Department Name 73,88 N. Staet Hwy 95. Columbia. Al. 36319 Address

4. Identification of System P16. Service Water S~ystem. Q1P16HBC29-56. Class 3
5. (a) Applicable Construction Code 1971 Edition,. Summer 1971 Addenda, N/A Code Case (b) Applicable Edition of Section Xl Used for Repair/Replacement Activity .2001 Edition. 2003 Addenda Ic) Applicable Section Xi Code Case(s) N/A
6. Identification of Components__________________

National ASME Code Name of Name of Manufacturer Board Year Corrected, Removed, Stamped (Yes or Component Manufacturer Serial No. No. Other Identification Built or Installed _ No)

Cone. IlTTGrinnell ADYN N/A FNP-210 1974 Removed No Reducer

,Conc. CPS Mfg., Inc KSF-2 N/A -"QP090461 2008 Installed No Reducer

7. Description of Work ,Replaced 6 x 3 concentrIc,reducer
8. Test Conducted: Hydrostatic Other []

I] Pneumatic EIJ Pressure _______psI Nominal Operating Pressure []

Test Temp. _________

Exempt F

Q]

FORM NIS-2 (Back)

9. Remarks Certificateof Conformance. Certified Material Test Report. NPP-1 Data Report. VT.2 Examination Applicable Manufacturer's Data Reports to be attached

.WO# SNtC 5718 CERTIRiCATE OF COMPLIANCE We certify that the statements made in the report are correct and that this realacement conforms to the rules of the ASME Code, Section Xl, repair or replacement Type Code Symbol Stamp N/A CertificateofA iion th No. -//_ IN/A Expiration Date N/A Signed - , * .*- [ ,. , ,]" Date *- -o. ) &-

Owner or Owner's Designee CERTIFICATE OF INSER VICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler end Pressure Vessel Inspectors and the state or Province of .Florida .and employed by .HSB GlobalStandards of _,Hprfford. CT.

have inspected/ the cpmponents described in this Owner's Report during the period oq-/i I4,*//Zo y C" to D O~0f .*- 5 . and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code,Section XI.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer SHALL be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this Inspection.

SInspector's Signet~n' National Board, State, Province and Endorsements Date t / l-a~-E-z-

FORM NIS-2 OWNER'S REPORT FOR REPAIR/REPLACEMENT ACTIVITY As Required By The Provisions Of The ASME Code Section Xi

1. Owner Southern Nuclear OperatinqCompany Date: 5/10/2015 Name Sheet 1 2 40 Inverness Ctr Pkwy. Birmingqham, AL 35242 A,.,A...~. Unit FNPUniti 2 of dtl Jo~~Anh M. Fnrlnv Nwnlanr Plnnt (FNIPi Wflh SNC 61572
2. Plant Repair/Replacement Organization P.O. No., Job No., etc.

Name 7368 N. State Hwy 95. Columbia, Al. 36319 Type Code Symbol Stamp N/A Address Authorization No. N/A

3. Work Performed By Expiration Date N/A FNP Maintenance Department Name 7308 N. State Hwy 95. Columbia, Al. 36319 Address
4. Identification of System Nl., Main Steam System. QIN11VOO10C. Class 2
5. (a) Applicable Construction Code .1971 Edition, Winter 1971 Addenda, 1574 Code Case (b) Applicable EdRiton of Section Xl Used for Repair/Replacement Activity 2001 EditIon. 2003 Addenda (c) Applicable Section XI Code Case(s) N/A
6. Identification of Components _______

National ASME Code Name of Name of Manufacturer Board Year Corrected, Removed, Stamped (Yes or Component Manufacturer Serial No. No. Other Identification Built or Installed No)

Value Body Dresser BP09806 N/A FNP-316 1974 Removed Yes Disc Dresser AAD03 N/A FNP-316 1974 Removed Na Compression Dresser AAC25 N/A FNP.316 1974 Removed No Screw Spindle Dresser AAC3S, AAC32 N/A FNP-316 1974 Removed No 1-3/8" Stud UN/C UNK N/A UN/C UNK Removed No (12) ___________________________________

1-3/8" Nut UNK UN/C N/A UN/C UNKC Remove No (24) _______

Value Body Dresser BP09807 N/A 5NA10092494 1974 Installed Yes Disc Dresser AJM61 N/A 5NA10092494 2014 Installed No Compression Dresser AIMBO N/A $NA10092494 2014 Installed No Screw Spindle Dresser AJL78 N/A 5NA10092494 2014 Installed No 1-3/8" Stud Curtis-Wright 3047857 N/A $NA36031-0081 2014 Installed No (12) 1-3/8" Nut Dubose 217575 N/A 5NA31710-0109 2014 Installed No (24) _________ __________ ______________________

7. Description of Work Replaced Main Steam Safety Valve NIN~l VOG10C with a rotation from stock. The replacement valve was reworked to include the extended wear modification pro vided in ED)SNc328243ED. Boitina was also realaced.
8. Test Conducted: Hydrostatic I] Pneumatic 5] Nominal Operating Pressure [] Exempt El Other El Pressure _______psi Test Temp. "F_______'

FORM NIS-2 (Back)

9. Remarks Code data reports,Certificatesof Conformance, Certified MaterialTest Reports, VT-2 Examination Applicable Manufacturer's Data Reports to be attached woI. sNC 61572 CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and that this .eplacement conforms to the rules of the ASME Code, Section Xl. repair or replacement Type Code Symbol Stamp N/A Certificate of Authorization No. N/A Expiration Date N/A Owner or Owner's Designee CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the state or Province of Florida and employed by HSB Global Standards of Hartford. CT have inspected the* components described in this Owner's Report during the period ' 4*/\'

1 / ;*ol' to o'*" / *"' / 2z.0' " , and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report In accordance with the requirements of the ASME Code,Section XI.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer SHALL be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

) 2.~AL'i Commisions \2--1 e 0-- tr-I... -'=* "

Inspector's Signature National .Board, State, Province and Endorsements Date OJZ'? ZO)*

Page 2 of 2

FORM NIS-2 OWNER'S REPORT FOR REPAIR/REPLACEMENT ACTIVITY As Required By The Provisions Of The ASME Code Section XI

1. Owner Southern Nuclear Operating Company Date: 5/10/2015 Name Sheet 1 of 2 40 Inverness Ctr Pkwv, Birminaqham, Al. 35242 Unit FNP Unit 1 M
  • UUaI U*T:

WON SNC 61575

2. Plant Joseph M. Farley Nuclear Plant (FNP)

Repair/Replacement Organization P.O. No., Job No., etc.

Name 7388 N. Sitat Hwv, gs. Columbia. ALl 38319 Type Code Symbol Stamp

  • N/A Address Authorization No. N/A
3. Work Performed By Expiration Date N/A FNP Maintenance Department Name 7388 NV.State Hwy 95. Columbia, Al. 36319 Address
4. Identification of System Nl., Main Steam System. O1N11VO0IOE. Class 2
5. (a) Applicable Construction Code 1971 Edition, Winter 1971 Addenda, 1574 Code Case (b) Applicable Edition of Section XI Used for Repair/Replacement Activity 2001 Edition. 2003 Addenda (c) Applicable Section Xl Code Case(s) N/A
6. Identification of Components National ASME Code Name of Name of Manufacturer Board Year Corrected,Removed, Stamped (Yes or Component Manufacturer Serial No. No. Other Identification Built or Installed No)

Valve Body Presser BP09812 N/A FNP-316 1974 Removed Yes Disc Dresser AAC57 N/A FNP-316 1974 Removed No ,

Compression Presser AABA7 N/A FNP-316 1974 Removed No Screw Spindle Dresser AAC02, AAB8S N/A FNP-316 1974 Removed No 1-3/8" Stud LUNK UINK N/A UNK UINK Removed No (12) 1-3/8" Nut UINK UNK N/A UNK UINK Remove No (24) ________ ___________________

Value Body Dresser BP09827 N/A 5NA10092494 1974 Installed Yes Disc Dresser AJM22 N/A SNA10092494 2014 Installed No Compression Dresser AJMB9 N/A 5NA10092494 2014 Installed No Screw Spindle Dresser AJL79 N/A 5NA10092494 2014 Installed No 1-3/8" Stud Curtis-WrIght 3047857 N/A 5NA36051-OOB1 2014 Installed No (12) _______________

1-3/8" Nut Dubose 217575 N/A 5NA3171 0-01 09 2014 Installed No (24) ______________________________

7. DescriptIon of Work Replaced Main Steom Safety Valve NitulliVODIOE wIth a rotation from stock. The replacement valve was reworked to include the extended wear modificationprovided In ED)5NC328243ED. Bolitngq was also replaced.

B. Test Conducted: Hydrostatic El Pneumatic I] Nominal Operating Pressure [] Exempt []

Other El Pressure ________psi Test Temp. F

r *1 ,J L~UUC SC! IUUIuu[f.UI. b. L.UFUU!lfIUrILC. t.Cl LItCU IV1UUlC55U ,CI rC~fl*IUI flOJn[Ui*I) V IS* CAU!UIFrUIlUU 6ss emark

w. Applicable Manufacturers Data Reports to be attached WO# SNC 61575 CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and that this renlacement conforms to the rules of the ASME Code,Section XI. repair or replacement Type Code Symbol Stamp N/A Certificate of Authorization No. N/A Expiration Date N/A Owner or Owner's Designee CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the state or Province of Florida and employed by HSB Global Standards of
  • Hartford. CT have inspected the components described in this Owner's Report during the period c*l/ / *op=

to r*Z/2l/ 2.'tg- and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section Xl.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer SHALL be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

Commisions t2-4oDAi*C., j-L 4- 4 S' National Board, S~tate, Province and Endorsements or' Inspect"// Sin" br Date Page 2 of 2

FORM NIS-2 OWNER'S REPORT FOR REPAIR/REPLACEMENT ACTIVITY As Required By The Provlsions Of The ASME Code Section Xl

1. Owner . Southern Nuclear OperatinprCompany Date: 5/9/2015 NaeSheet ___________of 2 40 Inverness Ctr Fkwv, Birmingham, Al. 35242 Unit FNP Unit 1 Aaorees WO# SNC 81576
2. Plant Josnnh M. Fnrlnv Nudlear Plnnt (FNPJ Repair/Replacement Organization P.O. No., Job No., etc.

Name 7388 N. State Hwy 95. Columbia, AL 36319 Type Code Symbol Stamp -N/A .. .

Address Authorization No. N/A

3. Work Performed By Expiration Date N/A

.FNP Maintenance Denartment Name 7388 N. State Hwy 95, Columbia, Al. 36319 Address

4. Identification of System Nl.,Main Steam Sys;tem. QIN11VOO1IE. Class 2 S. {a) Applicable Construction Code .1971 EditIon, Winter 1971 Addenda, 1574 Code Case (b] Applicable Edition of Section Xi Used for Repair/Replacement Activity _2001 Edition. 2003Addenda (c) Applicable Section Xl Code Case(s) NIA
6. Identification of Components_____

National ASME Code Name of Name of Manufacturer Board Year Corrected, Removed, Stamped (Yes or Component Manufacturer Serial No. No. Other Identification Built or Installed No)

Valve Body Dresser BP09R13 N/A FNP-316 1974 Removed Yes Disc Dresser AACS5 N/A FNP-316 1974 Removed No Compression Dresser AAB94 N/A FNP-E16 1974 Removed No screw Spindle Dresser AACO3, AAB9J N/A I:NP-316 1974 'Removed No 1-3/B" Stud UiNK UiNK N/A UiNK UNKC Removed No (12) ________ _________

1-3/8" Nut liNK UiNK N/A liNK UINK Removed No (24) ________________ __________

Valve Body Dresser BP09821 N/A SNA1O092494 1974 Installed Yes Disc Dresser AJP79 N/A 5NA10092494 2014 Installed No Compression Dresser A1M87 N/A 5NA10092494 "2014 Installed No Screw Spindle Dresser AJL76 N/A 5NA10092494 2014 Installed No 1-3/8' Stud Curtis-WrIght 3047857 N/A SNA36051-OO81 2014 Installed No (12) _________________

1.3/8" Nut Dubose 217575 N/A 5NA31710-0109 2014 Installed No (24) ______________________________________

7. Description of Work Replaced Main Steam Safety Valve NNIll VOOIIE with a rotation from stock. The replacementvalve was reworked to indlude the extended wear modificatIonprovided In ED)SNC32B243ED. Boltina was also replaced.
8. Test Conducted: Hydrostatic Q] Pneumatic [] Nominai Operating Pressure [] Exempt 0]

Other C] Pressure _______psi Test Temp. ____F___

FORM NIS-2 (Back)

9. Remarks Code data reports. Certificatesof Conformance. Certified Material Test Reports. VT-2 Examination Applicable Manufacturer's Data Reports to be attached WO# SNC 61576 CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and that this reolacement conforms to the rules of the ASME Code, Section Xl. repair or replacement Type Code Symbol Stamp N/A Certificate of Authorization No. N/A Expiration Date N/A Sonde*,,. 4 .i'~/ 31 ,,. 6i/A~ ae 5* ~/

Owner or Owner's Designee CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the state or Province of Florida and employed by HSB Global Standards of Hartford. CT have inspected the Fomponents described in this Owner's Report during the period ['}4/ 14 7/,-,o a*-

to 05"/?-.)/7-o I'* , and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code,Section XI.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer SHALL be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection. -

?O~fLI Commisions (~~ ~~~44 Inspector's Signature National Board, State, Province and Endorsements Date 0 2.'7 ZA~1~

Page 2 of 2

FORM NIS-2 OWNER'S REPORT FOR REPAIR/REPLACEMENT ACTIVITY As Required By The Provisions Of The ASME Code Section XI

1. Owner Southern Nuclear Operating Company Date: 5/10/2015 Name Sheet 1 of 2 40 Inverness Ctr pkw, Birmingham, Al. 35*24 Unit FNP~nit1

... . . .. . . . * ..e s. .afr . . .. . .. WO# SNC 61578

2. Plant Repair/Replacement Organization P.O. No., Job No., etc.

Name 7388 N. State Hwy 95. Columbia, AL 36319 Type Code Symbol Stamp -_ __N/A Address Authorization No. N/A

3. Work Performed By Expiration Date N/A FNP Maintenance Department Name 7386 N. State Hwy 95. Columbia, Al. 36319 Address
4. Identification of System Nl., Main Steam System. QIN11VOO10B. Class 2
5. (a) Applicable Construction Code 2971 Edition, Winter.1971 Addenda, 1574 Code Case (b) Appllcable Edition of Section Xi Used for Repair/Replacement Activity 2001 Edltion. 2003 Addenda (c) Applicable Section XI Code Case(s) N/A
6. Identification of Components _______ ____ _______________ _________________

'National ASME Code N eof Name of Manufacturer Board Year Corrected, Removed, Stamped (Yes or Camponent Manufacturer Serial No. No. Other Identification Built or Installed No)

Valve Body Dresser BP09820 N/A FNP2-64 1974 Removed Yes DicDresser AAC93 N/A FNP2-64 1974 Removed No 1-3/8" Stud UNK UNK N/A UINK UNK Removed No (12) ________ ______________

1-3/8" Nut UINK UNK N/A UINK UINK Remove No (24) ___ _______

Value Body Dresser BP09828 N/A 5NA10092494 1974 Installed Yes Disc Dresser AiM58 N/A $NA10092494 2014 installed No 1-3/8" Stud Curtis-Wright 3047857 N/A SNASSO051-0081 2014 installed No (12) ________ ____

1.3/8" Nut Dubose 217575 N/A $NA31710-0109 2014 Installed No (24) _________

7. Description of Work Replaced Main Steam Safety Valve NI N1/01VOlO with a rotation from stock. The replacement valve was reworked to replace the disc. Baiting was also replaced.

B. Test Conducted: Hydrostatic 5] Pneumatic [] Nominal Operating Pressure [] Exempt []

Other 0] Pressure _______psI Test Temp. _____F___

FORM NIS-2 (Back)

9. Remarks Code data reports.Certificatesof Conformance. Certified Material Test Reports. VT.2 Examination Applicabie Manufacturer's Data Reports to be attached WONl SNC 61578 CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and that this renlacement conforms to the rules of the ASME Code, Section Xl. repair or replacement Type Code Symbol Stamp NIA Certificate of Authorization No. N/A Expiration Date N/A Owner or Owner's Designee CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the state or Province of Florida and employed by HSB Global Standards of ,Hartford. CT have inspected the cgmponents described in this Owner's Report during the period 04./f /2 I/'**

to fl S*/Z7 */"* ,and state that to the best of my knowledge and belief, the Owner has performed examinations arnd taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section Xl.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer SHALL be liable In any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

inspector's Signature National Board, State, Province and Endorsements Date 0 "2i-'Z/o, "-

Page 2 of 2

FORM NIS-2 OWNER'S REPORT FOR REPAIRIREPLACEMENT ACTIVITY As Required By The Provisions Of'The ASME Code Section Xi

1. Owner Southern Nuclear OperatinaConmpany Date: 5/9/2015 NaeSheet 1 of 2 40 Inverness Ctr-Pkwyr Birmingham, AL 35242

^.. .. Unit FNPUnit I WON SNC 61580

2. Plant Joseph M. Farley Nuclear Plant(FNPJ Repalr/Replacement Organization P.O. No., Job No., etc.

Name 7388 N. State Hwv, 95. Columbia. Al. 36319 Type Code Symbol Stamp N/A Address Authorization No. N/A

3. Work Performed By Expiration Date N/A FNPMaintenance Deaartment Name 7358 N. State Hwy 95. Columbia. Al. 36319 Address
4. identification of System Nll, Main Steam Sys;tem. QNIN1VO011B, Class2 S. (a) Applicable Construction Code 1971 Edition, Winter 1971 Addenda, 1574 Code Case (b) Applicable Edition of Section Xl Used for Repair/Replacement Activity 2001 Editlon. 2003Addenda Cc)Applicable Section Xl Code Case(s) N/A
6. Identification of Components National ASME Code Name of Name of Manufacturer Board Year Corrected, Removed, Stamped (Yes or Component Manufacturer Serial No. No. Other identification Built or Installed No)

Valve Body Dresser BP09819 N/A FNP2-64 1974 Removed Yes Disc Dresser AAD03 N/A FNP2-64 1974 Removed No Compression Dresser AAC2S N/A FNP2-64 1974 Removed No Screw Spindle Dresser AAC3S, AAC32 N/A FNF2-64 1974 Removed No 1-3/8" Stud UNK UNK N/A UNK UNK Removed No (12) _________ _

1-3/B" Nut UINK UNK N/A UNK UNK Remove No (24) _______

Valve Body Dresser BP09804 N/A SNA10092494 1974 Installed Yes Disc Dresser AJMS5 N/A SNA10092494 2014 Installed No Compression Dresser A1M86 N/A 5NA10092494 2014 Installed No Screw Spindle Dresser A1L77 N/A SNA10092494 2014 Installed No 1-3/8'" Stud Curtis-Wright 3047857. N/A 5NA36051-OOB1 2014 Installed No (12) ________ ___________ _______________________________

1-3/B" Nut Duhose 217575 N/A 5NA5171 0-01 09 2014 Installed No

7. Description of Work Replaced Main Steam Safety Valve NiN11VO0lIB with a rotationfrom stock. The replacement valve was reworked to include the extended wear modification pravidedin ED SNC32B243ED. Salting was also replaced.
5. Test Conducted: Hydrostatic [] Pneumatic 5] Nominal Operating Pressure [] Exempt 0]

Other I] Pressure________psi Test Temp. _____F___

(af~

FORM NIS-2 (Back)

9. Remarks Code data reports. Certificates of Conformnance, Certified MaterialTest Reports. Vtr-2 Examination Applicable Manufacturer's Data Reports to be attached WO# SNC 61580 CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and that this replacement conforms to the rules of the ASME Code, Section Xl. repair or replacement Type Code Symbol Stamp N/A Certificate of Authorization No. N/A Expiration Date N/A
  • ,. (§ L-,}u-. Owner or Owner's e~signee .

CERTIFICATE OF INSERVICE INSPECTION - __

I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the state or Province of, Florida and employed by HSB Global Standards of Hartford. CT have inspected the 9ompenents described in this Owner's Report during the period. O,4-/i *q la.o "

to- oi.~ /- ) //. ' . and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section Xl.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer SMALL be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection. * -

Commislons tZ.C,,oA ti*c,,F* '>

' Inspector's Signatur 6 / .. National Board, State, Province and Endorsements O.Z Da~te -t

FORM NIS-2 OWNER'S REPORT FOR REPAIR/REPLACEMENT ACTIVITY As Required By The Provisions Of The ASME Code Section XI

1. Owner .Southern Nuclear OperatingCompany Date 6/22/2015 Name 40 Inverness Ctr Pkwy, Birmingham, AL, 35242 Sheet 1of 2 Address
2. Plant .Joseph M. Farley Nuclear Plant (FNP) Unit FNP UNIT 1 Name 7388 N. State Hwy 95, Columbia, AL 36319 WO#: SNC4O1 189 Address Repair/Replacement Organization P.O. No., Job No., etc.
3. Work Performed by FNP MaintenanceDepartment Type Code Symbol N/A Stamp_____________

Name Authorization N/A No. _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

7388 N. State Hwy. 95, Columbia, AL. 36319 Expiration N/A Date Address

4. Identification of System P17, Component Cooling Water System, Q1P17VO126A, Class 3
5. (a) Applicable Construction Code ASME Sect. III 1974 Edition, Summer 1975 Addenda, N/A Code Case (b) Applicable Edition of Section Xl Used for Repair/Replacement Activity 2001 EDI 2003 ADD (c) Applicable Section Xl Code Case(s) N/A
6. Identification Of Components

,,,atoalT1 oretd, AMECd (eso NO)

Built INSTALLED 1 'X2" ANDERSON GREENWOOD N99846-00-0002 N/A No. PO 0P040739 P0: QIdenicaio 2005 REMOVED YES RELIEF VALVE MANufacture Serial0-No.

Component I $"X 2" ANDERSON N99846-00-0012 N/A P0: QP100946 2010 INSTALLED NO RELIEF VALVE GREENWOOD __________ _______________

7. Description of Work Relief valve replaceddue to old valve leaking past seat.
8. Test Conducted: Hydrostatic Other [] ri PneumaticE-'

Pressure _____psi NominalTest Operating Temp. Pressure*J Exempt[--

Page 1 of 2

FORM NIS-2 (Back)

Certificate of Compliance, NV-i Form, VT-2 Exam SNC4emarks Applicable Manufacturer's Data Reports to be attached SNC4Oi1B9 CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and that this Replacement conforms to the rules of the ASM E Code, Section Xl.

Type Code Symbol Stamp N/A Certificate of Authorization No. N/A Expiration Date N/A Owner or Owner's Designee, Title CERTIFICATE OF INSER VICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the state or Province of Florida and employed by HSB5 Global Standards of HrodCT have inspected the components described in this Owner's Report during the period *// o,-

to________2.o,;" and state that to the best of my- knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section Xl.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures describedin this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

  • k{, *,e* * -* t %j 'Commissions l'2-*aDAi,* ,..F ",-

Inspector's Signature National Board, State, Province and Endorsements Date o -- Zo%

Page 2 of 2

  • FORM NIS-2 OWNER'S REPORT FOR REPAIRIREPLACEMENT ACTIVITY As Required By The Provisions Of The ASME Code Section Xl
1. Owner Southern Nuclear OaeratinqCompany Date: 5/3/2015 NaeSheet ___________of 2 40 Inverness Ctr Pkwy, Birmineham. Al. 35242 A.. .. Unit FNP Unit I MUUIUS*

Josenh M. FarleyNuclear Plant (FNEI)

WO.# SNC 401237

2. Plant Repair/Replacement Organization P.O. No., Job No., etc.

Name 7388 N. State Hwy 95. Columbia. Al. 36319 Type Code Symbol Stamp N/A Address Authorization No. N/A

3. Work Performed By Expiration Date~ N/A FNp Maintenance Oepfertment Name 7386 N. State Hwy 95. Columbia, AL. 36319 Address
4. Identification of System N23. Auxiliar Fe~edwater, QIN23VOO66B. Class 2
5. (a) Applicable Construction Code .1971 Edition,. Winter 1971 Addenda, N/A Cade Case (b) Applicable Edition of Section Xi Used for Repair/Replacement Activity _2001 Edition. 2003 Addenda (c) Applicable Section Xl Code Case(s) N/A
6. identification of Components National ASME Code Name of Name of Manufacturer Board Year Corrected, Removed, Stamped (Yes or Component Manufacturer Serial No. No. Other identification Built or Installed No)

Relief Valve Lonergan 210289-6-4 N/A FNP2-S1 1972 Removed Yes 1/2" Nuts (8) UNK UINK N/A UINK UINK Removed No 1/2" Studs UINK UINK N/A UINK LINK Removed No (4) ____________________

Relief Volve Crosby N99846.0O- N/A QP040739 2005 Installed No 0004 1I/2" Nuts (B) Dubose 10106080 N/A SNA31710-073 2014 Installed No 1/2" Studs CardinalIndustrial X(569B N/A SNA31372 -0089 2014 Installed No (4) __________________________________

7. Description of Work Replaced relief value asaescheduled up~arade 0] 5]Pressure 0]
8. Test Conducted: Hydrostatic Pneumatic [] Nominal Operating Pressure Exempt []

Other _______psi Test Temp. "_______

]a*-

FORM NIS-2 (Back)

9. Remarks Certificatesof Compliance. Cerifled MaterialTest Reports. NV-I data reports Applicable Manulacturer's Data Reports to be attached

.WON,SNC 401fl7 CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and that this ren~lacement conforms to the rules of the ASME Code,Section XI. repair or replacement Type Code Symbol Stamp N/A Certificate ofAuhori 1 ation No,.N/ Expiration Date N/A Signed o~r Date__ _______

Owner or Owner's Designee CERTIFICATE OF INSER VICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the state or Province of Florida and employed by HSB Global Standards of - Hartford. CT have inspectecj the qsomponents described in this Owner's Report during the period ) 4/0 3/*-ol '"

to

  • L *I 201/*O

'* . and state that to the best of my knowledge and belief, the O)wner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code,Section XI.

By signing this certificate neither the inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer SHALL be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this Inspection. 'kk 4 4 j~,* e Cmiin tO~AJ',F~4

  • Intspector's Signature U National Board, State, Province and Endorsements Daeoo /0o1

FORM NIS-2 OWNER'S REPORT FOR REPAIRIREPLACEMENT ACTIVITY As Required By The Provisions Of The ASME Code Section Xl

1. Owner .Southern Nuclear Operating Company Date 4/28/2015 Name 40 Inverness Ctr Pkwv. Birmingham. AL. 35242 Sheet 1 ~ of2 Address
2. Plant Joseph M. Farley Nuclear Plant (FNP) Unit FNP UNIT 1 Name 7388 N. State Hwy 95, Columbia, AL 36319 WO#: SNC 431379 Address RepeirlReplacement Organization P.O. No., Job No., etc.
3. Work Performed by FNP MaintenanceDepartment Type Code Symbol N/A Stamp Name Authorization No. N/A 7388 N. State Hwy. 95, Columbia, AL. 36319 Expiration N/A Date Address
4. Identification of System E21, CHEMICAL VOLUME CONTROL SYSTEM, QIE21V173, CLASS 3
5. (a) Applicable Construction Code. ASME Sect. III 1971 Edition, WINTER 1971 Addenda, N/A Code Case (b) Applicable Edition of Section Xl Used for RepairlReplacement Activity 2001 ED. 2003 ADD (c) Applicable Section Xl Code Case(s) N/A
6. Identification Of Components National Corrected, ASME Code Name of Name of Manufacturer Board Other Year Removed, or Stamped Component Manufacturer Serial No. No. Identification Built Installed (Yes or No) 2" BALL VALVE BNL A 100608-1-2 N/A P0: 0P100602 2010 REMOVED YES 2" BALL VALVE BNL Al10507-1-1 N/A P0: 0Pl10378 2011 INSTALLED YES
7. Description of Work REPLACE 2" BALL VALVE BODY, BONNET. AND DISC, WITH NEW BODY, BONNET AND DISC.
8. Test Conducted:

Other ri J[J Hydrostatic Pressure Pneumeticr-j

_____psi NominalTest Operating Temp. Pressure

_____ JX'] Exempt[-J F__O Page 1 of 2

FORM NIS-2 (Back) 79 CERTIFICATE OF COMPLIANCE, VT-2 EXAMINATION, Cemar Applicable Manufacturer's Data Reports to be attached 9.

SNC43I 379 CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and that this REPLACEMENT conforms to the rules of the ASME Code, Section Xl.

Type Code Symbol Stamp N/A Certificate of Authorization No. N/A Expiration Date N/A Signed ..

Date S-I-Owner or Owner's Designee, *tl* "

CERTIFICATE OF INSER VICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the state or Province of Florida and employed by HSB Global Standards of H rtford, CT have inspected the components described in this Owner's Report during the period JAILL*/L.o .

to___ . */' 7.,- ,and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code,Section XI.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

Commissions \ z.(,b;Au r4 *., *--*/5 Inspector's Sign~ure National Board, State, Province and Endorsements Date 0*" 2/ Dl~

Page 2 of 2

FORM NIS-2 OWNER'S REPORT FOR REPAIR/REPLACEMENT ACTIVITY As Required By The Provisions Of The ASME Code Section XI

1. Owner Southern Nuclear OperatingCompany Date Name 40 Inverness CtrPkwy, Birmingham, AL. 35242 Sheet 1 of 2 Address WO/2S4/20146
2. Plant Joseph M. FarteyNuclear Plant (FNP) Unit FNP UNIT I Name 7388 N. State Hwy 95, Columbia, AL 36319 Address WON: SNC482146 RepeirlReplacement Organization P.O. No.. Job No., etc.
3. Work Performed by FNP MaintenanceDepartment Type Code Symbol N/A Stamp_______________

Name Authorization N/A No. _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

7388 N. State Hwy. 95, Columbia, AL. 36319 Expiration N/A Date Address

4. Identiiication of System P17, Component Cooling Wafer. QIPl7VOOO6C, Class 3
5. (a) Applicable Construction Code ASME Sect. III 1971 Edition, Winier 1971 Addenda, N/A Code Case (b) Applicable Edition of Section Xi Used for RepairlReplacernent Activity 2001 ED. 2003 ADD.

(c) Applicebie Section Xl Code Case(s) N/A

6. Identification Of Components National Corrected, ASME Code Name of Name of Manufacturer Board Other Year Removed, or Stamped Cornponent Manufacturer Serial No. No. Identification Built installed (Yes or No) 1 W"X 2" LONERGAN 210130-6-5 N/A P0: FNP-296 1974 REMOVED YES RELIEF VALVE _______ _____ ____

34" STUDS AND UNK UNK UNK UNK UNK REMOVED UNK NUTS 1 W"X 2" ANDERSON N99846-0O.O0015 N/A P0: SNVA 10056360 2013 INSTALLED YES RELIEF VALVE GREENWOOD

_________ CROSBY _______ ____

I/2" 13 UNC CARDINAL N/A N/A ' HT: X569B '1985 INSTALLED NO STUDS INDUSTRIAL _ ____P0: SNA31372.0089 _____ ____

34*"13 LUNC HEX TRUST MFG. N/A N/A HT. 466900 2011 INSTALLED NO NUTS ______P0: SNA 10020728 __________

7. Description of Work. Replaced relief valve and bolting,materials with new valve. atuads and nuts.
8. Teat Conducted: Hydrostatic [] Pneumatic -- NominaiTest Operating Other [] Pressure _____psi Temp. Pressurej"x' Exempt --[

Page 1 of 2

FORM NIS-.2 (Back)

Certificate of Conformance, ED.:_SC-OS-S-0040, VT-2 Examination, NV-i Form NRam2r4s Applicable Manufacturer's Data Reports to be attached 9.

SNC482146 CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and that this Repliacement .conforms to the rules of the ASME Code, Section Xl.

Type Code Symbol Stamp N/A Certificate of Authorization No. N/A ,Expiration Date N/A Sind, - at _

uwner or wnar'8 Designee. Title CERTIFICATE OF INSER VICE INSPECTION I, the undersigned, holding a valid commission issued by the Nationai Board of Boiler end Pressure Vessel Inspectors and the state or Province of Florida and empioyed by iISB GLOBAL S;TANDARDS of H rtf r, CT have Inspected the components described in this Owner's Report during the period ..- *-/S:L1 z...J ito *t7 ",,. ao.c 4, and state that to the best of. my knowledge end belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code,Section XI, By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

Inspect6r's Signature National Board, State, Province and Endorsements Date Page 2 of 2

FORM NIS-2 OWNER'S REPORT FOR REPAIRIREPLACEMENT ACTIVITY As Required By The Provisions Of The ASME Code Section Xl 1.Owner Southern Nuclear Operatingi Company Date 2/27/2015 Name 40 Inverness Cf r Pkwy, Birmingham, AL, 35242 Sheet Iof2 Address

2. Plant Joseph M. Farley Nuclear Plant (FNP) Unit _FNP UNIT 1 Name 7388 N. State Hwy 95, Columbia, AL 36319 WO#: SNC482608 Address Repair/Replacement Organization P.O. No., Job No., etc.
3. Work Performed by FNP MaintenanceDepartment Type Code Symbol N/A

-Stamp ______________

Name Authorization N/A No.__________________ _

7388 NV.State Hwy. 95, Columbia, AL. 363*319 Expiration N/A Date _______________________

Address

4. Identification of System P17, Component Cooling Water, 0IP17V0006B, Class 3
5. (a) Applicable Construction Code ASME Sect. III 1974 Edition, Summer 1975 Addenda, N/A Code Case (b) Applicable Edition of Section Xl Used for RepairlReplacement Activity 2001 El:I/2003 ADD (c) Applicable Section Xl Coda Case(s) NIA
6. Identification Of Components National Corrected, ASME Code Name of Name of Manufacturer Board Other Year Removed, or Stamped Camponent Manufacturer Serial No. No. Identification Built Installed (Yes or No) 1 Wa"X 2= LONERGAN 210130-6.4 N/A P0: FNP-296 1972 REMOVED YES RELIEF VALVE __________________

WaSTUDS (4) UNK UNK N/A UNK UNK REMOVED UNK AND NUTS (8) _____________ ___ _____ _____

1 1/2" X 2" ANDERSON N99846-0O-OO0t N/A P0: QP040739 2005 INSTALLED NO RELIEF VALVE GREENWOOD _______

a"STUDS (4) CARDINAL N/A N/A HEA T: X569B 1985 INSTALLED NO INDUSTRIAL ______P0: SNA31372-0089 _______________

1/2"NUTS (8) DUBOSE N/A N/A H1: 10106080 2014 INSTALLED NO NATIONAL ______P0: SNA31710-0073

7. Description of Work Replaced valve and bolting as upgrades.
6. Test Conducted: Other 5] E]

Hydrostatic Pneumatic[:]

Pressure _____psi NominalTest Operating Temp. Pressure~x]

Exempt[5 Page 1 of 2

FORM NIS-2 (Back)

Certificate of Compliance, NV-i Form, VT-2 Exam, Equivalency Determination: SC-05-S-0040, SS1109-02 Appendix A_________________________

S.NR4marks Applicable Manufacturer's Data Reports to be attached SNC482608 CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and that this Replacement conforms to the rules of the ASME Code,Section XI.

Type Code Symbot Stamp N/A Certificate of N/A Authorization No.

Expiration Date N/A Signed ~r&. joi~, MA.~4AAd~ lAadP.6L, Date *j*I 3 h--

-I Owner or Owner's Designee, Titfe CERTIFICATE OF INSER VICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler end Pressure Vessel Inspectors end the state or Province of Florida and employed by HSB Global Standards of .HtfrCT

_____________have inspected the components described in this Owner's Report during the period oz/-/2o("

____to o%/ I'7/ _oD ".. ,and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described In this Owner's Report in accordance with the requirements of the ASME Code, Section Xl.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective meassures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

SCommissions Z,3 e 4- r I Inspector's Signature~ National Board, State, Province and Endorsements Date03 /.o "

Page 2 of 2

FORM NIS-2 OWNER'S REPORT FOR REPAIRIREPLACEMENT ACTIVITY As Required By The Provisions Of The ASME CadsSection XI

1. Owner Southern Nuclear OperaIn# Company Date 2/11/~2 014 Name 40 Inverness CtrPkwy, Birmiingham, AL, 35242 Sheet 1oa 2 Address
2. Plant Joseph M. FarteyNucIearPlant (FNP) Unit FNP UNIT 1 Name 7388 NV.Stale Hwy 95, Columbia, AL 36319 WO#: SNC 496768 Address ReparldReplacement Organization PO. No., Job No., etc.

3.Work Performed by FNPMaintenance Department Type Code Symbol N/A Stamp__________ __

Name Authorization N/A No. _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

7388 N. State Hwy. 05, Columbia, AL. 36319 Expiration N/A Datae_ _ _ _ _ _ _ __ _ _ _ _ _ _ _

Address 4.

Identification of System P16. Senica Water. 01P16V0603, Class 3

5. (a) Applicable Construction Code Sect. III 1971 Edition, Winter 1971 Addenda, N/A Coda Case (b) Appliiabie Edition of Section Xi Used for Repeir/Reptacemenl Activity 2001 ED. /2003 ADD.

(c) Applicable Section Xl Code Case(s) ... WA.....

5. Identificat~on Of Components National Corrected, ASME Code Name of Name of Manufacturer Board Other Year Removed, or Stamped Component Manufacturer Seriai No. No. Ide~ntlfication Built Installed (Yes or No) 2" ELBOW GRINNELL N/A N/A HT: K614 UNK REMOVED UNK 2" PIPE GRINNELL N/A N/A HT: L65803 UNK REMOVED UNK 2" CHECK KEROTEST DX2-10 N/A P0: FNP.295 1975 REMOVED YES VALVE 2" ELBOW BONNEY FORGE N/A N/A HT: C70098 2010 INSTALLED NO

________ ___________ ~~P0: 0P100877 ___ _________

2" PIPE MICHIGAN N/A N/A HT: 00A054337 2008 INSTALLED NO

______SEAMLESS PIPE ______P0: 0P080236 _______________

2" CHECK FLOWSERVE 07BRP N/A P0): 0P100933 2011I INSTALLED YES VAL VE______ __

ER70S-2 ESAB N/A N/A NT: 065943 2013 INSTALLED NO ELECTRODE P0: SNA 10052943 (1./,8,') _______ ______ __________ _____ ________ ____ _

ER70S.2 ESAB NV/A N/A HT: 065706 2004 INSTALLED NO ELECTRODE P0:. QP040823 (3/327 ____________________)__ ____ ______ _____

E7018 ESAB N/A N/A lIT: 080538 2009 INSTALLED NO ELECTRODE P0: 0P090712

7. Description of Work Replaced valve and pipin. with new due to valve leak-by.
8. Test Conducted: Hydrostatic [] Pneumatlcr-j Nominal Operating Prossure[xJ ExemptO~

Other [] Pressure _____psi Test Temp. _______

Page 1 of 2

FORM NIS-2 (Beck)

Certificate of Compliance, NPV-1 Form.Manufacturer's CMTRs, ED: C052065101 Applicable Dats Reports to be attached 9.NRe9ark8 SNC49B768 CERTIFICATE OF COMPLIANCE We ceodify that the statements made In the report arm correct and that this Replacement conforms to the rules of the ASME Code,Section XI, repair or replacement Type Code Symbol Stamp N/A Certificate of Authorization N/A N/A N/A No.

Signed "

Exprato D*

Owner o On'r's Designee. Title

£:: 7-'-(

CERTIFICATE OF INSER VICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel inspectors and the state or Provinc, of *'.7-LE4Z>tA and employed by t-S9 4;R-o*.L r_ r bAl*- s Of ,t..e--

____have jnptdthe components described In this Owner's Report during the period I /l:*I .. to

... 07/bZ/.o .z, and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described tn this Owner's Report in accordance with the requirements of the ASME Code, Section Xi.

By signing this certificate neither the inspector nor his employer makes any warranty, expressed or implied, concerning the examinations end corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal Injury or property damage or a loss of any kind arising from or connected with this Inspection.

lI~npector's Signature National Board, State, Province and Endorsements Date GI0/*

  • Page 2 of 2

FORM NIS-2 OWNER'S REPORT FOR REPAIR/REPLACEMENT ACTIVITY As Required By The Provisions Of The ASME Code Section Xl

1. Owner Southern Nuclear OperatinaCaomany Date: 5/10/2015 Name Sheet 1 of 2.

40 Inverness Ctr Pkwy. Birmningham, Al. 35242 Address. Unit FNP Unit 1

2. Plant . Joseph M. FarleyNuclear Plant(FNP) Repair/Replacement Organization P.O. No., Job No., etc.

Name 7388 N. State Hwy 95. Columbia, AL. 36319 Type Code Symbol Stamp N/A Address Authorization No.

3. Work Performed By N/A Expiration Date N/A FNPMaintetnance Department Name 7388 N. Stale Hwy 95. Columbia, AL 36319 Address
4. identification of System E21. Hiqh HeadSafety Iniection/ Chemical Volume Control Svstem. QIE21SNUBBSS4063B. Class 2 S. (a) Applicable Construction Code AISC -1969 Edition, N/A Addenda, N/A Code Case (b) Applicable Edition of Section Xi Used for Repair/Replacement Activity 2001 Edition. 2003 Addenda (c) Applicable Section Xl Code Case(s) N/A
6. Identification of Components ________

National ASME Code Name of Name of Manufacturer Board Year Corrected, Removed, Stamped (Yes or Component Manufacturer Serial No. No. Other Identification Built or Installed No)

Hydraulic Llsega 61287/56 N/A QP9$O0277 1993 Removed No Snubber Hydraulic Uisega 3110330/019 N/A SNA10090082 2014 Installed No Snubber

  • 7. Description of Work Replaced snubber as a scheduled upqrade 5] Q]Pressure Pneumatic 5] El 8, Test Conducted: Hydrostatic Nominal Operating Pressure Exempt []

Other _______psi Test Temp. "F_______

FORM NIS-2 (Back)

9. Remarks Certificote of Compllance, VT-3 Examination Applicable Manufacturer's Data Reports to be attached WON SNC 505849 CERTIFICATE OF COMPLUANCE We certify that the statements made in the report are correct and that this rep*lacement conforms to the rules of the ASME Code,Section XI. repair or replacement Type Code Symbol Stamp N/A Criiaeof Authorization N~N/A ~ Expiration Date N/A Owner or Owner's Designee-'

CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the state or Province of Florida and employed by HSB Global Standards of Hartford. CT have isetdthe components described in this Owner's Report during the period o4 4/t), /o2.o1" to oS"/fZ7/o 20 *" and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section Xl.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer SHALL be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

Inspector's Signature National Board, State, Province and Endorsements Date " ,/ ,--

Page 2 of 2

FORM NIS-2 OWNER'S REPORT FOR REPAIR/REPLACEMENT ACTIVITY As Required By The Provisions Of The ASME Code Section XI 1.Owner Southern Nuclear Operatingl Company Date 4/25/2015 Name 40 Inverness Ct, Pkwy, Birmingham, AL, 35242 Sheet I of 2 Address

2. Plant Joseph M. Farley NuclearPlant (FNP) Unit FNP UNIT 1 Name 7388 N. State Hwy 95, Columbia, AL 36319 WO#: SNC505856 Address RepairlReplacement Organization P.O. No., Job No., etc.
3. Work Performed by FNP Maintenance Department Type Code Symbol N/A Stamp Name Authorization N/A No.

7388 N. State Hwy. 95, Columbia, AL. 36319 Expiration N/A Date Address

4. Identification of System E21. Chemical Volume Control System, Q IE21SNUBBSS4338, Class2
5. (a) Applicable Construction Code AISC 1969 Edition, N/A Addenda, N/A Code Case (b) Applicable Edition of Section XI Used for Repair/Replacement Activity 2001 ED / 2003 Add.

(c) Applicable Section XI Code Case(s) NIA

6. Identification Of Components National Corrected, ASME Code Name of Name of Manufacturer Board Other Year Removed, or Stamped Component Manufacturer Serial No. No. Identification Built Installed ,(Yes or No)

HYDRAULIC LISEGA 6128 7/58 N/A P0: 0P950277 1993 REMOVED NO SNUBBER _______________ _________

HYDRAULIC LISEGA 31400822/028 N/A P0: SNAI10096059 2014 INSTALLED NO SNUBBER ___________________

t ., Y ., Y

.1

£ .~ a

7. Description of Work Replaced snubber due to seal life expiration.
8. Test Conducted: Hydrostatic [] PneumaticE-' Nominal Operating PressureE]

Other [] Pressure _____psi Test Temp. ______ Exempt l' Page 1 of 2

FORM NIS-2 (Back)

9. Remarks Certificate of ComPliance. VT-3 Examination.

Applicable Manufacturer's Data Reports to be attached SNC505856 CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and that this. Replacement conforms to the rules of the ASME Coda,Section XI.

Type Code Symbol Stamp N/A Certificate of Authorization No.N/ /V/A Expiration Date N/A

,*c.,.*..*t-TItle */*t*

Designee, Signed A~Ivc5'!hLM or Owner's Owner AA!*~O~

Date Owner or Owner's Designee, Title f~A1 Mc~~~S-CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the state or Province of Florida and employed by HSB Global Standards of Hartford, CT have inspected the components described in this Owner's Report during the period t,4 / -o*/z.-r.."

to_______o*" and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section Xl.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

-;l .,_ ',,.* Commissions~ 24.03A l,*, *z*-44 Inspector's Signature (JNational Board, State, Province and Endorsements Date / -Zo -

Page 2 of 2

U)

FORM NIS-2 OWNER'S REPORT FOR REPAIR/REPLACEMENT ACTIVITY As Required By The Provisions Of The ASME Code Section XI 1.Owner Southern Nuclear Operating Company Date 4/27/2015 Name 40 Inverness Ctr Pkwy, Birmingham, AL, 35242 Sheet 1 of 2 Address

2. Plant Joseph M. Farley Nuclear Plant (FNP) Unit FNPUNIT 1 Name 7388 N. State Hwy 95, Columbia, AL 36319 WO#: SNC505860 Address Repair/Replacement Organization P.O. No., Job No., etc.
3. Work Performed by FNP Maintenance Department Type Code Symbol Stamp N/A Name Authorization N/A No.

7388 N. State Hwy. 95, Columbia, AL. 36319 Expiration N/A Date Address

4. IdentificatIon of System G24,Steam GeneratorBlowdown System. QIG24SNU1BBSS4447, Class 2
5. (a) Applicable Construction Code AISC 1969 Edition, N/A Addenda, N/A Code Case (b) Applicable Edition of Section Xl Used for Repair/Replacement Activity 2001 ED /2003 Add.

(c) Applicable Section XI Code Case(s) N/A

6. Identification Of Components Corrnctled AMes CodeNo SeilN. National Natieniitonalui Board Corrected,or Removed, ASME Code Stamped Q .2 Name of Cmoet Mnfcue Name of Manufacturer Other Year Component Manufacturer Serial No. Board No. Identification Built Removed, Installed or Stamped (Yes or No)

HYDRAULIC LISEGA 61287,76 N/A PC: QP950277 1993 REMOVED NO SNUBBER ____________ __________ _______________ _______ ___________ _________

HYDRAULIC LJSEGA 314008221018 N/A P0: SNA 10090082 2014 INSTALLED NO SNUBBER ________ ____________ _________

7. Description of Work Replaced

! snubber due to end of service life..

/ 3/4!

8. Test Conducted:

Other 5] 5]

Hydrost~aatic Pneumaticfl Pressure _____psi NominalTest Operating Pressurefl Temp. ____ Exempt0' F__

Page 1 of 2

FORM NIS-2 (Back)

©-

Certificate of Compliance, VT-3 Examination.

SNC5ema8k0 Applicable Manufacturer's Data Reports to be attached 5NC505860 CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and that this Replacement conforms to the rules of the ASME Code, Section Xl.

Type Code Symbol Stamp N/A Certificate of Authorization No. N/A Expiration Date N/A Signed M ~2t~ I:~.L Date Owner or Owner's Designee, Title' CERTIFICATE OF INSER VICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the state or Province of Florida and employed by HSB Global Standards of Hat~rlCT have inspected the components described in this Owner's Report during the period */,/z-

  • to__/___/__1<- and state that to the best of my knowledge and belief, the Owner has performed q~aminations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code,
  • ~ction Xl.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable inany manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

  • r, *J* "IL *
  • Commissions -*t.3A,.A ,*.1 *j.4,*-"

I..nspector's Signat-'-ure"] - National Board, State, Province and Endorsements Date I/* "

,.. -I Page 2 of 2

FORM NIS-2 OWNER'S REPORT FOR REPAIR/REPLACEMENT ACTIVITY As Required By The Provisions Of The ASME Code Section XI

1. Owner Southern Nuclear Operating company Date: 5/4/2015 Name Sheet 1 of 2 40 Inverness Ctr Pkwv, Birmingqham. Al. 35242 Address Unit FNP Unit I woN SNC 505.862
2. Plant Joseoh M. FarleyNuclear Plant(FNP) Repair/Replacement Organization P.O. N'o., Job No., etc.

Name 7388 N. State Hwy, 95. Columbia, Al. 36319 Type Code Symbol Stamp N/A Address Authorization No.

3. Work Performed By N/A Expiration Date N/A Name 7388 N. State Hwy 95. Columbia. Al. 36319 Address
4. Identification of System G24. Steam GeneratorBlowdown System. Q1G24SNUJBBSS4458A. Class 3
5. (a) Appiicable Construction Code AISC- .1969 Edition, N/A Addenda, N/A Code Case (b) Appilcabie Edition of Section Xi Used for Repeir/Repiacement Actlvity 2001 Editlon. 2003 Addenda Cc()

Applicable Section Xi Code Case(s) N/A

6. Identification of Components _______

National ASME Code Name of Name of Manufacturer Board Year Corrected, Removed, Stamped CYes or Component Manufacturer Serial No. No. Other Identification Built or Installed No)

Hydraulic L lsega 61287/86 N/A QP950277 1993 Removed Na Snubber Hydraulic Ulsega 34100822/035 N/A $NA10096059 2014 Installed No Snubber

7. Description of Work Replaced hydraulic snubber because of seal llfeexalrtaton
8. Test Conducted: Hydrostatic [] Pneumatic 0] Nominal Operating Pressure [] Exempt 0]

Other 0] Pressure _______psi Test Temp. _____F___

"* ', - , " " ., .- .. .. :' . " ' " ' '* ," ". - . *;"'* ! : . - ' *:, ""

  • I','.,,t" .'* ': *' " . " . " , ' ,' , ." . !

FORM NIS-2 (Beck)

9. Remarks Certificateof Conformance.* VT.3 Examinations; Applicable Manufacturer's Data Reports to be attached WO.# SNC 505862 CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and that this replacement conforms to the rules of the ASME Code,Section XI. repair or replacement Type Code Symbol Stamp N/A CetiicNo/AN/AExpiration Date -NA/A Signed /****~~t.l,. *,,x'r, Date *-'-r '-I
  • /*

Owner or Owner's Designee CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the state or Province of .Florida and employed by. HS.B Globa*l Standards of Hartford. CT have inspacted the components described in this Owner's Report during the period .o*/ ,.I/i-oi 5" to o* / 2* / 2..o*5 . end state that to tha best of my knowledge end belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code,Section XI.

By signing this certificete neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures descdibed in this Owner's Report. Furthermore, neither the Inspector nor his employer SHALL be liable in any manner for any personal injury or property damage or a lose of any kind arising from or connected with this inspection,

"* M-q't 5f** Commisions '*.-(,.o5AI4C~.. FL4 4 *'-

Inspector's Signatur*e National Board, State, Province and Endorsements Date '/./.,-

Page 2 of 2

... S

.~ .

S- S.

.~. --..,

FORM NIS-2 OWNER'S REPORT FOR REPAIR/REPLACEMENT ACTIVITY As Required By The Provisions Of The ASME Code Section Xi

1. Owner Southern Nuclear Operating Company Date 4/'2/2015 Name 40 lnvempss CIr Pkwy, Birmingham, AL, 35242 Sheet 1 of 2 Address Joseph M. FarleyNuclear Plant(FNP) Unit 'FNPUNIT
2. Plant Name 7388 N. Slate H-wy 95. Columbia, AL 36319 WOif: SNC505883 Address RepuirlReplacement Organization P.O. No., Job No., etc.
3. Work Performed by FNP Maintenance Department Type Coda Symbol N/A Stamp ____________

Name Authorization N/A No._________________ _

7388 N., State Hwy. 95. Columbia, AL. 36319 Expiration N/A Date Address

4. Identification of System P17, Component Cooling Water, System. QI1PI7SNUBBSS5730B, Class 3
5. (a) Applicable Construction Code AISC 1969 Edition, N/A Addenda, N/A Code Case (b) Applicable Edition of Section XI Used for RepairlRepiacement Activity 2001 ED 12003 Add.

(c) Applicable Section Xl Code Case(s) NJL&..A.

6. identification Of Components
  • '.National Corrected, ASME Code
  • .Name of Name of Manufacturer Board Other Year Removed, or Stamped Component Manufacturer Serial No. No. Identification Built installed (Yes or No)

HYDRRIAULIC LISEGA 61287/55 N/A P0: 0P950277 1993 REMOVED NO SNUBBER _____________________

HYDRAULIC LISEGA 31400822/026 N/A P0: SNA 10096059 2014 INSTALLED NO SNUBBER ______

7. Description of Work Replaced snubber due to seal life expiration.
8. Test Conducted: Hydrostatic [] Pneumatic[] Nominal Operating Pressurel'] Exemnpt []

Other [] Pressure ____psi Test Temp., ____

Page 1 of 2

FORM NIS-2 (Back)

Certlficate of Compliance. Applicable VT-3 Examination.

Manufacturer's Data Reports to be attached 9.NRemark3 SNC505863 CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and that thia Rsnlacement conforms to the rules of the ASME Code,Section XI.

Type Code Symbol Stamp AL/A Certificate of Authorization No.EpiaonDtNA AL/A Expiration Date N/A Title One(gnee, Signed or Owner's Owner Owner or Owners Designee, Title I lIE I I I II I II II II I II CERTIFICATE OF INSER VICE INSPECTION I, the undoerigned, holding a valid commission issued by the National Beard of Boiler end Pressure Vessel inspectors and the state or Province of Flordda and employed by HSB Global Standa..ds of ..........Jr, Z.....

,hasve inspected the components described in this Owner's Report during the period .. Li 1*,/-rfZ

_______i '7z-IIIIIL*'- Z..... and slate that to the best of my knowledge and belief, the Owner has performed

. xaminations and taken corrective measures described In this Owner's Report in accordance with the requirements of the ASME Code,

,ction XI.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in thIs Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal inlury or property damage or a loss of any kind arising from or connected with this inspection.

i'''' tf~ _****-*0 *?~ Commissions t,2-.-3Ait].o Fa-4i~e)-

. ... . - Inspector's 'Sign;ature)- - National Beard, State, Province and Endorsements Date Page 2 of 2

FORM NIS-2 OWNER'S REPORT FOR REPAIR/REPLACEMENT ACTIVITY As Required By The Provisions Of The ASME Code Section XI

1. Owner Southern Nuclear Operating Company Date 1/23/2015 Name 40 Inverness Ctr Pkwy, Birmingham, AL, 35242 Sheet 1 of 2 Address
2. Plant Joseph M. Farley Nuclear Plant(FNP) Unit ENP UNIT 1 Name 7388 N. State Hwy 95, Columbia, AL 36319 DCP SNC 467134, WO# SNC509544 Address RepairlReplacement Organization P.O. No., Job No., etc.
3. Work Performed by FNP Maintenance Department Type Code Symbol N/A (WILLIAMS) Stamp Name Authorization N/A No.

Expiration 7388 NV. State Hwy. 95, Columbia, AL. 36319 N/A Date Address

4. Identification of System N23, AUXILIARY FEED WATER SYSTEM (AFW), CLASS 3
5. (a) Applicable Construction Code 1971 THRU 2000' Edition, N/A Addenda, N/A Code Case (b) Applicable Edition of Section XI Used for Repair/Replacement Activity 2001 EDITION, 2003 ADDENDA (c) Applicable Section Xl Code Case(s) N/A
6. Identification Of Components National Corrected, ASME Code Name of Name of Manufacturer Board Other Year Removed, or Stamped Cmoet Manufacturer Serial No. No. Identification Built Installed I~sor No) 4"lPIPE TEE TAYLOR N/A N/A SNA33232-0336 2014 INSTALLED NO FORGE HT#NNLM-1

_______ STAI NLESS ____________ ___

4" 90 DEG. TAYLOR FORGE N/A N/A SNA33232-0336 2014 INSTALLED NO ELBOW (SEA.) STAINLESS HT#NNLM-1 _____

4" VALVE BNL INDUSTRIES SN#A4041 1-2-1 N/A SNAl10079070 2014 INSTALLED YES 4" FLANGE WESTERN FORGE N/A N/A SNA33232-0345 2014 INSTALLED NO

& FLANGE HT#207W939 4" BLIND WFI N/A N/A SNA33232-0336 2014 INSTALLED NO FLANGE HT#1 749ANF 1 1/8" STUD NOVA N/A N/A SNAl10086065 2013 INSTALLED NO BOLTS (8EA.) HT#NF121 02435,TR#0B 89 4" PIPE SCH. TAYLOR FORGE N/A N/A SNA3171O0-054 2014 INSTALLED NO 80 STAINLESS HT#1 10765 ______

NUTS 1 1/8" NOVA N/A N/A QP091036 2009 INSTALLED NO (16EA.) _______________HT#223422 TC# 3U05 ____________ _____

7. Description of Work INSTALLED VALVE AND COMPONENTS per DCP 467134 AND WO# 509544
8. Test Conducted:

Other fl Hydrostatic [] PneumaticLJ Pressure _____psi NominalTestOperating Temp. Pressurej']

____ F__ExemptE--

Page 1 of 2

FORM NIS-2 (Back)

9. Remarks VALVE AND COMPONENTS INSTALLED per DCP 467134 AND WO# 509544. SS1 10902, SAM FLEX PROJECT Applicable Manufacturer's Data Reports to be attached VT2 EXAMINATION PERFORMED CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and that this NEW conforms to the rules of the ASME Code,Section XI.

Type Code Symbol N/A Stamp Certificate of N/A Expiration Date N/A Authorization No. ____________________

Signed A*enn.eth W. Baity Dt Owner or Owner's Designee, Titl e CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the state or Province of Florida and employed by HSB Global Standards of Hartford. CT have inspected the components described in this Owner's Report during the period i~~ZZ II to___ O,0'-o",and state that to the best of my knowledge and belief, the Owner haoefrdteOnrhs performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section Xl.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

Commissions -o**A

  • t, {*4 .

Inspector's Signaturev National Board, State, Province and Endorsements Date0* "'.o "

Page 2 of 2

FORM NIS-2 OWNER'S REPORT FOR REPAIR/REPLACEMENT ACTIVITY As Required By The Provisions Of The ASME Code Section Xl

1. Owner Southern Nuclear Operating Company Date -02/16/2015 Name 40 Inverness Ctr Pkwy, Birmingham, AL, 35242 Sheet 1 of2 Address
2. Plant Joseph M. FarleyNuclear Plant(FNP) Unit FNP UNIT 1 Name 7388 N. State Hwy 95, Columbia, AL 36319 DCP SNC 467134, WO#: SNC 509547 Address Repair/Replacement Organization P.O. No., Job No., etc.
3. Work Performed by FNP Maintenance Department Type Code Symbol N/A (WILLIAMS) Stamp Name Authorization NV/A No, 7388 N. State Hwy. 95. Columbia, AL. 36319 Expiration N/A Date Address
4. Identification of System N23, Ul AUXILIARY FEEDWATER SYSTEM, , 5S-3444, CLASS 3
5. (a) Applicable Construction Code AlSO 1 969 Edition, N/A Addenda, N/A Code Case (b) Applicable Edition of Section Xl Used for Repair/Replacement Activity 2001 EDITION, 2003 ADDENDA (c) Applicable Section XI Code Caae(s) Ni4....A .
6. Identification Of Components National Corrected, ASME Code Name of Name of Manufacturer Board Other Year Removed, or Stamped Component Manufacturer Serial No. No. Identification Built Installed (Yes or No)

'/" PLATE SABEL STEEL N/A N/A SNA1 0088779 2014 INSTALLED NO SCM-CGDP-126

________________________HT#238019 _____ _____________

ANCHOR ANVIL N/A N/A SNA 10093318 2014 INSTALLED NO ASSEMBLY P/N 1297328 2" ______ _____________ ____ ______

7. Description of Work SUPPORTMODIFIED PER DCP 467134 AND WO# 509547,SS-3444
8. Test Conducted: Other 1=1 ri Hydrostatic PneumaticE--

Pressure _____psi NominalTest Operating Temp. Pressuref--

Exempt[*]

Page 1 of 2

FORM NIS-2 (Back)

9. Remarks SUPPORT MODIFIED PER DCP 467134 AND WO# 509547, SS1 10902, DEDICATION PLAN *SCM-CGDP-126 Applicable Manufacturer's Data Reports to be attached VT3 EXAMINATION PERFORMED 5AM Tho~~cr (l.-~ 6 A/zo CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and that this NEW conforms to the rules of the ASME Code, Section Xl, Type Code Symbol N/A Stamp Certificate of N/A Authorization No.

Expiration Date N/A Signed *wnr r wrr' Dnineth WTBity* Date *5/*

Owner or Owr~r's Designee, litW -

CERTIFICATE OF INSER VICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the state orProvince of Florida and employed by HSB Global Standards of Hertford, CT have inspected the components described in this Owner's Report during the period A, LL4/1o J ..

___ o_ O/,=/.-:",and state that to the best of my knowledge and belief, the Owner has performed examinations and taken' corrective measures described in this Owner's Report In accordance with the requirements of the ASME Code, Section Xl.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or Implied, concerning the examinations end corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shell be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

Inspector's Signature tJNational Board, "State, Province and Endorsements Date o( [ I 3" 2-/'Z, Page 2 of 2

FORM NIS-2 OWNER'S REPORT FOR REPAIRIREPLACEMENT ACTIVITY As Required By The Provisions Of The ASME Code Section XI Owner Southern Nuclear Operating Company Date 02/04/2015 Name 40 Inverness Ctr Pkwy, Birmiingham, AL, 35242 Sheet 1 of 2 Address

2. Plant Joseph M. FarleyNuclear Plant (FNP) Unit FNP UNIT 1 Name 7388 N. State Hwy 95, Columbia, AL 38319 DCP SNC 467134, WO#: SNC 509550 Address Repair/Replacement Organization P.O. No., Job No., etc.
3. Work Performed by FNP MaintenanceDepartment Type Code Symbol N/A (WILLIAMS,) Stamp Name Authorization No. N/A 7388 N. State Hwy. 95, Columbia, AL. 3631* 9 Expiration N/A Date Address
4. Identification of System N23, AUXILIARY FEED WATER SYSTEM, SCS-H780,SCS-H779, CLASS 3 5.(a) Applicable Construction Code AlISC 1 969 Edition, N/A Addenda, N/A Code Case (b) Applicable Edition of Section XI Used for Repair/Replacement Activity 2001 EDITION, 2003 ADDENDA (c) Applicable Section Xl Code Case(s) NIA
6. Identification Of Components National Corrected, ASME Code Name of Name of Manufacturer Board Other Year Removed, or Stamped Component Manufacturer Serial No. No. Identification Built Installed (Yes or No) 1/4A"PLATE NUCOR N/A NA 8NA31372-0045 2013 INSTALLED NO SCS-H780 HT# A3N0375-02 ______

3/4'"PLATE NUCOR N/A NA SNA31607-0002 2013 INSTALLED NO SCS-H780 SCGM-CGDP-1 26 _ ___

4"X4"X1/4" SABEL STEEL N/A NA SNA10082837 2014 INSTALLED NO TUBE STEEL SCM-CGDP-1 26 SCS-H780 HT#J40401 R 1" PLATE NUCOR N/A NA QP110426 2011 INSTALLED NO SCS-H779 HT#B1S6924 SCS-H780 SCM-CGDP-126 3/8" PLATE NOVA MACHINE N/A NA SNA36051-0101 2015 INSTALLED NO ROLLED PRODUCTS SNA36051-0029 SCS-H779 HT#4504999 HT#3508612 4"X3"X5/16" ATLAS TUBE N/A N/A SNA10095489 2014 INSTALLED NO TUBE STEEL HT#D8251 1

,$¢UZ-__7__

TUBE STRUCT. SOUTHLAND N/A N/A OP1 10442 2008 INSTALLED NO STEEL TUBE HT #A46150 5"X5"X5/116 SCS-H780_______________

7. Description of Work SUPPORTS INSTALLED PER WO SNC509550, DCP SNC467134, SCS-H779, SCS-H-780 Page 1 of 2
8. Test Conducted: Hydrostatic [] Pneumaticf-- Nominal Operating Pressure[-- Exempt '*

Other [] Pressure _____psi Test Temp. ____ F__

FORM NIS-2 (Rack)

9. Remarks SUPPORTS INSTALLED PER DCP 467134 AND WO # SNC509550, S1l10902, DEDICATION PLAN :SCM-CGDP-126 Applicable Manufacturer's Data Reports to be attached VT3 EXAMINATION PERFORMED CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and that this NEW conforms to the rules of the ASME Code, Section Xl.

Type Code Symbol N/A Stamp Certificate of N/A Authorization No.

Expiration Date N/A Kenneth S" h *e

  • o*W.A*n~,~

Baity Signed ~s 1 Date ,.*/,-

Owner or Owner'd Designee, Title j... -

CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the state or Province of Florida and employed by HSB Global Standards of H~rfr.CT haye inspected the components described in this Owner's Report during the period t **,.iq to______ot-/.Lp5 *" , and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code,Section XI.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

Inspector's Signatur~ National Board, State, Province and Endorsements

° oDate,<

Page 2 of 2

FORM NIS-2 OWNER'S REPORT FOR REPAIR/REPLACEMENT ACTIVITY As Required By The Provisions Of The ASME Code Section XI

1. Owner Southern Nuclear OperatingCompany Date 3/5/2015 Name 40 Inverness Ctr Pkwy, Birminglham, AL, 35242 Sheet 1 of 2 Address
2. Plant Josevh M. FarleyNuclear Plant (FNP) Unit FNP UNIT I Name-7388 NV.

State Hwy 95, Columbia, AL 36319 DCP SNC 467134, WO#: SNC 509578 Address RepairdReplacement Organization P.O. No., Job No., etc.

3. Work Performed by FNP Maintenance (WILLIAMS) Type Code Symbol N/A Stamp Name Authorization N/A No.

7388 N. State Hwy. 95, Columbia, AL. 36319 Expiration N/A Date Address

4. Identification of System N23, AUXILIARY FEEDWATER SYSTEM, AFW-R81, CLASS 3
5. (a) Applicable Construction Code Al SC 1969 Edition, N/A Addenda, N/A Code Case (b) Applicable Edition of Section Xl Used for Repair/Replacement Activity 2001 EDITION, 2003 ADDENDA (c) Applicable Section Xl Code Case(s) ...... WA......
6. Identification Of Components National Corrected, ASME Code Name of Name of Manufacturer Board Other Year Removed, or Stamped Component Manufacturer Serial No. No. Identification Built Installed (Yes or No) 1/" PLATE SABEL STEEL N/A N/A SNA10088779 2014 INSTALLED NO SCM-CGDP-126 HT# 238019
7. Description of Work SUPORMDI iEDor DC .673 .AD. . 097. AW....
8. Test Conducted: Hydrostatic [] Pneumeticr- NominalTestOperating Exemptfrx-Other [] Pressure _____psi Temp. PressureE]

0 F

Page 1 of 2

FORM NIS-2 (Back)

9. Remarks SUPPORT MODIFIED PER DCP 467134 AND WO# 509578, SS1 10902, DEDICATION PLAN: SCM-CGDP-126 Applicable Manufacturer's Data Reports to be attached VT3 EXAMINATION PERFORMED CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and that this NEW , conforms to the rules of the ASME Code,Section XI.

Type Code Symbol N/A Stamp Certificate of N/A Expiration Date N/A Authorization No. ____________________ __________________

Signed i*

  • J* Kenneth W. Batty Date "9/?_fji5 Owerr wnrsDesignee, Title fA ,'p ' *t,.e, *a r CERTIFICATE OF.INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the state or Province of Florida and employed by HSB Global Standards; of Hartford CT have inspected the, components described In this Owner's Report during the period t/J2-0*

to__'___-o_' and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section Xl.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable In any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

5 4 j ~ . commissions Inspector's Signature" National Board, State, Province and Endorsements Date O'/ (/2. f*

Page 2 of 2

FORM NIS-2 OWNER'S REPORT FOR REPAIR/REPLACEMENT ACTIVITY As Required By The Provisions Of The ASME Code Section XI

1. Owner Southern Nuclear OperatingCompany Date 03/02/2015 Name 40 Inverness Ctr Pkwy, Birmingham, AL. 35242 Sheet 1 of 2 Address
2. Plant Joseph M. Farley Nuclear Plant (FNP) Unit FNP UNIT 1 Name 7388 N. State Hwy 95. Columbia, AL 36319 DCP SNC 467136, WO# SNC512081 Address Repair/Replacement Organization P.O. No., Job No., etc.

3.Work Performed by FNP Maintenance Department Typo Code Symbol N/A (WILLIAMS) Stamp ______________

Name Authorization N/A No.__________________

7388 N. State Hwy. 95, Columbia, AL. 36319 Expiration N/A

________________________________ Date _______________________

Address

4. Identification of System E21, CHEMICAL VOLUME CONTROL SYSTEM, 01 E21 -CCB-1 5, CLASS 2
5. (a) Applicable Construction Code ASME SECTION 111,1971 Edition, SUMMER 1971 Addenda, N/A Code Case (b) Applicable Edition of Section XI Used for Repair/Replacement Activity 2001 EDITION, 2003 ADDENDA (c) Applicable Section XI Code Case(s) N/A
6. Identification Of Components National Corrected, ASME Code Name of Name of Manufacturer Board Other Year Removed, or Stamped Component Manufacturer Serial No. No. Identification Built Installed (Yes or No) 2" PIPE SANDVIK STEEL N/A NA QP99086i 1999 INSTALLED NO

_____________ ~ HT# 442617 ___________

2" VALVE VALV SN#14106968 NA SNA10079045 2014 INSTALLED YES TECHNOLOGIES 2" VALVE VALV SN#1 4106969 NA SNA 10079045 2014 INSTALLED YES TECHNOLOGIES 7/8 "STUDS T&T N/A NA SNA31 372-0259 2014 INSTALLED NO (8EA.) ENTERPRISES HT # 10228850 7/8" NUTS T&T N/A N/A SNA31372-0259 2014' INSTALLED ... NO (16EA) ETPRSSHT # S10903_____

2" FLANGE WFI N/A N/A SNA33232-0405 2015 INSTALLED NO FLANGE HT # 6434ANE3_____

2" 90 DEG. BONNEY FORGE N/A NA SNA33232---0242 2011 INSTALLED NO ELBOW CORP. I-T

  • NK ___
7. Description of Work NEW VALVES AND COMPONENTS INSTALLED PER DCP467136AND WO#i 512081
8. Test Conducted: Hydrostatic Other [] 5] Pneumatic['-

Pressure _____psi NominalTestOperating Temp. Pressure[-X Exemptfl

°F_____

Page 1 of 2

FORM NIS-2 (Back)

9. Remarks NEW VALVES AND COMPONENTS INSTALLED per DCP 467136 AND wO# 512081 Applicable Manufacturer's Data Reports to be attached VT2 EXAMINATION PERFORMED CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and that this NEW conforms to the rules of the ASME Code, Section Xl.

Type Code Symbol N/A Stamp Certificate of N/A Expiration Date N/A Authorization No. ____________________ __________________

SignedrOwe'sDsineTil Dae-fA CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the state or Province of Florida and employed by HSB Global Standards; of tqr.C h~ave inspected the components described in this Owner's Report during the period z t1//-oI to_____'__:)*- and stale that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section Xi.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, conceming the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

ip_.o*,E.H * *I* aI.J *Commissions t*(o'*Am ,c, 44**"

Inspector's Signature'LZ. National Board, State, Province and Endorsements Daeolo Page 2 of 2

FORM NIS-2 OWNER'S REPORT FOR REPAIR/REPLACEMENT ACTIVITY As Required By The Provisions Of The ASME Code Section XI

1. Owner Southern Nuclear Operating Company Dale 02/04/2015 Name 40 Inverness Ctr Pkwy, Birming/ham. AL, 35242 Sheet 1 of 2 Address
2. Plant Joseph M1.FarleypNuclearPlant (FNP) Unit FNP UNIT 1 Name 7388 N. State Hwy 95, Columbia, AL 36319 DCP SNC 467136, WO# SNC51 2082 Address Repair/Replacement Organization P.O. No., Job No., etc.
3. Work Performed by FNP Maintenance Department Type Code Symbol N/A (WILLIAMS) Stamp Name Authorization N/A No.

7388 NV.

State Hwy. 95, Columbia, AL. 36319 Expiration N/A Date Address

4. Identification of System E21, CHEMICAL VOLUME CONTROL SYSTEM, Q1 E21 -CCB-21, CLASS 2
5. (a) Applicable Construction Code 1971 Edition, 1971 SUMMER Addenda, N/A Code Case (b) Applicable Edition of Section Xl Used for Repair/Replacement Activity 2001 EDITION, 2003 ADDENDA (c) Applicable Section Xl Code Case(s) ... N/A ...
6. Identification Of Components National Corrected, ASME Code Name of Name of Manufacturer Board Other Year Removed, or Stamped cornponent Manufacturer Serial No. No. identification Built Installed I~sor NoI 2" PIPE WALSIN N/A N/A SNA31372-0201 2014 INSTALLED NO SPECIALTY STEEL HT#1 1E587 ______

2" VALVE VALV SN#14106972 N/A SNA10079045 2014 INSTALLED YES

_________TECHNOLOGIES ______

2" VALVE VALV SN#14106973 N/A SNA10079045 2014 INSTALLED YES TECHNOLOGIES PIPET 2" ON 3" WFI N/A N/A SNA33232-0317 2014 INSTALLED NO HT#7O61ANA 2" 90 DEG. BONNEY FORGE N/A N/A NA33232--0242 2014 INSTALLED NO ELBOW CORP. ______HTftNK_____

7. Description of Work NEW VALVES AND COMPONENTS INSTALLED PER DCP467136AND WO# 512082
8. Test Conducted: Hydrostatic Other [] E] Pneumaticr-Pressure NominalTest

_____psi Operating Temp. Pressure[XJ

°F ExemptE-1 Page 1 of 2

FORM NIS-2 (Back)

9. Remarks NEW VALVES AND COMPONENTS INSTALLED per DCP 467136 AND WO# 512082, SAM FLEX PROJECT Applicable Manufacturer's Data Reports to be attached VT2 EXAMINATION PERFORMED CERTIFICATE OF COMPLIANCE, We certify that the statements made in the report are correct and that this NEW conforms to the rules of the ASME Code,Section XI.

Type Code Symbol N/A Stamp Certificate of N/A Expiration Date Authorization No. N/A_

Signed Date (/*I*

Owner or OilAiner's Designee, "litI'e CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the state or Province of Fieodda and employed by HSB Global Standards .of. HartfordI CT

_____________have inspected the components described in this Owner's Report during the period ... t*./i ! / *. o

_____to o */ r,9 / 7-'o1 , and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section Xl.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or Implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this Inspection.

Inspector's Signature *'National Board, State, Province and Endorsements Date O*lt / o,

  • Page 2 of 2

FORM NIS-2 OWNER'S REPORT FOR REPAIRIREPLACEMENT ACTIVITY As Required By The Provisions Of The ASME Code Section XI 1.Owner Southern Nuclear OperatingCompany Date 1/15/2015 Name 40 Inverness Ctr Pkwy, Birmingham, AL, 35242 Sheet 1 of 2 Address

2. Plant Joseph M. Farley Nuclear Plant (FNP) Unit FNP UNIT 1 Name 738 .State Hwy95,oluba,AL 36319 DCP SNC 467142. WO#: SNC 512253 Address Repair/Replacement Organization P.O. No., Job No., etc.
3. Work Performed by FNP Maintenance Department Type Code Symbol Stamp N/A Name Authorization N/A No.

7388 NV.State Hwy. 95, Columbia, AL. 36319 Expiration N/A Date Address

4. Identification of System Q1G31 U1 SEP COOLING, Q1G31-HCC-107, CLASS 3
5. (a) Applicable Construction Code ASME SECT. III, 1971 Edition, SUMMER 1971 Addenda, ______Code Case

{b) Applicable Edition of Section Xl Used for Repair/Replacement Activity 2001 EDITION, 2003 ADDENDA (c) Applicable Section XI Code Case(s) N/A

6. Identification Of Components National Corrected, ASME Code Name of Name of Manufacturer Board Other Year Removed, or Stamped Component Manufacturer Serial No. No. Identification Built Installed (Yes or No) 3" VALVE BNL VALVES Al110509-1-11 NA QP1 10393 2011 INSTALLED YES 3" PI PING DUBOSE N/A NA SNA10017398 201 1 INSTALLED NO NATIONAL HT#370 140 3" PIPET wRl NA NA SNA33232-0151 2014 INSTALLED NO HT#5997ANA1 3" FLANGE WESTERN NA NA SNA33232-0175 2018 INSTALLED NO FORGE & HT#248300

______FLANGE CO.,_____ ___ ____ ___

3" BLIND WESTERN NA NA SNA33232-0175 2013 INSTALLED NO FLANGE FORGE & HT#E111304

______FLANGE CO.___ ________

5/8" DU BOSE NA NA SNA31 710-0116 2014 INSTALLED NO STUDS NATIONAL HT#781879

_______ ENERGY ____ _____ __ ____

5/8" NUTS DUBOSE NA NA SNA31710-0116 2014 INSTALLED NO NATIONAL HT#1 0109320

_______ ENERGY _______ _______

3" 90 TAYLOR FORGE NA NA SNIA1001 7405 2011 INSTALLED NO DEGREE HT#MZYK-1 ELBOW ____________________ __

Page 1 of 2

7. Dscritioof orkVALVE AND COMPONENTS INSTALLED PER SNC467142 AND WO# 8NC512253. SSl 10902
8. Test Conducted:

Other fl Hydrostatic Pressure

[] Pneumaticf-l

______psi NominalTest Operating PressureJ--

Temp. _______ F Exempt[--

FORM NiS-2 (Back)

9. Remarks CERTIFICATE OF CONFORMANCE. WO#f SNC512253. DCP SNC467142. VT-2 EXAMINATION Applicable Manufacturer's Data Reports to be attached CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and that this NEW conforms to the rules of the ASME Code, Section Xh.

Type Code Symbol Stamp* N/A Certificate of N/A Authorization No. ...

N/A Date Expiration Signed Owner or Owner's Designee, Title 4--Ml" "*l- * *

  • CERTIFICATE OF INSERVICE INSPECTiON I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the state or Province of .. Florida and employed by HSB Globa*l Standards of HrfdCT

. have inspected the components described in this Owner's Report during the period j L/L/ t,... ..

to___ * / 1: ,and state that to the best of my knowledge and belief, the Owner" has p~erformed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section Xl...

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a less of any kind arising from or connected with this inspection.

TP-b*.' ,** * , Commissions l 2-so*A 41C.

  • Inspector's Signature' National Board, State, Province and Endorsements Date , ,/ ,--

Page 2 of 2

FORM NIS-2 OWNER'S REPORT FOR REPAIR/REPLACEMENT ACTIVITY As Required By The Provisions Of The ASME Code Section XI

1. Owner Southern Nuclear Operating Company Date 8/4/20 15 Name 40 Inverness CtrPkwy, Birminglham, AL, 35242 Sheet 1 of 2 Address
2. Plant Joseph M. Farley Nuclear Plant (FNP) Unit FNP UNIT I Name 7388 N. State Hwy 95, Columbia, AL 36319 WO#: SNC527228 Address Repair/Replacement Organization P.O. No., Job No., etc.
3. Work Performed by FNP Maintenance Department Type Code Symbol N/A Stamp Name Authorization N/A No.

7388 N. State Hwy. 95, Columbia, AL. 36319 Expiration N/A Date Address

4. Identification of System PI6, Service Water System, QIP16VO0072, Class 2
5. (a) Applicable Construction Code ASME Sect, III 1974 Edition, Summer 1975 Addenda, N/A Code Case (b) Applicable Edition of Section Xl Used for Repair/Replacement Activity 2001 ED/12003 ADD (c) Applicable Section XI Code Case(s) W/A
6. Identification Of Components National Corrected, ASME Code Name of Name of Manufacturer Board Other Year Removed, or Stamped Component Manufacturer Serial No. No. Identification Built ,Installed (Yes or No) 6" BUTTERFLY ENER TECH 10358 N/A P0: 0P950247 1995 REMOVED YES VLA VE_____ __

6" BUTTERFLY ENER TECH 12658 N/A P0: SNA 10096996* 2015 INSTALLED YES VALVE ______

  • I. .h~L A &
7. Description of Work Replaced valve with new as an upgrade.
8. Test Conducted: Hydrostatic Other [] [] PneumaticE]

Pressure _____psi NominalTest Operating Pressure Temp.,______ J*] 0 F

ExemptE-Page 1 of 2

FORM NIS-2 (Back)

9. Remarks Certificate of Compliance, NPV-1 Form, VT-2 Exam, LDCP: SNC6401 59, Radiographic Inspection Report Applicable Manufacturer's Date Reports to be attached SNC527228 CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and that this Replacement conforms to the rules of the ASME Code, Section Xl.

Type Code Symbol Stamp N/A Certificate of Authorization N/A No.

Expiration Date N/A Signed I~U~ i Date (*-.23-/

Owner or Owner's Designee, Title CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the state or Province of Flodida and employed by HS;B Global Standards of aHrfrCT

_have inspected the components described in this Owner's Report during the period 0-OPZoi*

to 0'7/O.~j4/2-o1L;" and state that to the best of my knowledge and belief, the owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section Xl.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shell be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

"* *hF-q'-.t* * , Commissions 72-h,03,A1g * *' .-

National Board, State, Province and Endorsements Date *0/ ,"

Page 2 of 2

FORM NiS-2 OWNER'S REPORT FOR REPAIR/REPLACEMENT ACTIVITY As Required By The Provisions Of The ASME Code Section Xl

1. Owner Southern Nuclear Opa tling Company Date 4/28i2014 Name 40 Inverness Cit Pkwy, Birmingham. AL, 35242 Sheet I of 2 Address
2. Plant Joseph M. FarleyNuclearPlant (FNP) Unit FNP UNIT I Name 7388 N. State Hwy 95, Columbia, AL 36319 WOI#: SNC544347 Address RepalrlReplacement Organiza=tion P.O. No., Job No., etc.
3. Work Performed by FNP Maintenance Depadtment Type Code Symbol N/A Stamp__ _ _ _ _ _ _ _ _ _ _

Name Authorizatlon hAL/

No._________________ _

7388 N. State Hwy. 95. Columbia, AL. 38319 Expiration NL/A Dates__________________

Address

4. Identilication of System QfP16V0584, P16, Service Water, Class 3
5. (a) Applicable Construction Code 1971 Edition, Winter 1971 Addenda, N/A Code Case (b) Applicable Edition of Section Xl Used for RepalrlReplacement Activity 2001 EDI 2003 ADD.

(c) Apqplicable Section Xl Code Case~s) N/

6. Identification Of Components

""National correted, ASME Code Name of Name of Manufacturer Board Other Year ,Removed, or Stamped Cmoet Manufacturer Serial NO. No. Ide ntification Built Installed (es or No) 2' CHECK DUIBOSE N/A N/A HEAT: 25376 2006 REMOVED NO VAL VE DISC _ ____P0: 0P050547______ ____

2"CHECK FLOWSERVE 31331-7 N/A P0: SNA27950.0080 2013 INSTALLED NO VALVE DISC ________ ____

7. Description of Work Replaced check valve disc due to leak-by
8. Test Conducted: Hydrostatic 5]

Other [] Pressure Pneumaiicf-]

_____psi Nominal Operating Test Temp. Preseure[]

_______ F Exsmpt[r]

Page 1 of 2

FORM NIS.-2 (fleck)

NPV-1 Form, Certificate of Compliance, N-2 Form Applicable Manufacturer'S Data Reports to be attached 9.NRemark7 5NC544347 CERTIFICATE OF COMPLIANCE We certify that the statements made In the report am correct and that this Reofacoment conforms to the rules of the ASME Code,Section XI.

Type Code Symbol Stamp N/A Certificate of Authorization_ No. /V/A Expiration Date N/A ow~trrOwn~s Iilgme, Title j  ;,

CERTIFICATE OF INSER VICE INSPECTION-- _ __ -- _

I, the unjiersignsd, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inepectors and the state or Provinceof_ *-o*I, and employed by iAq~w 6.oDFA *'r*0l,.* o ']::*-'*r

_ have Inspected the components described In this Owner's Report during the period t Q&L2./* 1- to _

Old .'-2o*4 and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report In accordance with the requirements of the ASME Code,Section XI.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or Implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable In any manner for any personal injury or property damage or a ioss of any kind arising from or connected with this inspection.

-- ' * *Commission m-- *- - - p -

' Ins1[(*ector'$ Signature National Board, State, Province and Endorsements Oats O,!o /2*,--/.oV*{-

Page 2 of 2

FORM NIS-2 OWNER'S REPORT FOR REPAIRIREPLACEMENT ACTIVITY As Required By The Provisions Of The ASME Code Section Xi

1. Owner Southern Nuclear Operating Comnany Date: 4/28/2015 Name Sheet 1 of 2 40 Inverness CtrPkwy, Birmingham. Al. 35242 Address Unit FNPUnit 1 writi RNII*. *R51q57
2. Plant Joseph M. Farley Nuclear Plant (FNP) Repair/Replacement Organization P.O. No., lob No., etc.

Name Type Code Symbol Stamp . .. N/A 7398 N. State Hwy 95. Columbia, Al. 36319 Address Authorization No. N/A

3. Work Performed By Expiration Date N/A FNp Maintenance Deoartment Name 7388 N. State Hwy 95. Columbia, Al. 36319 Address
4. Identification of System N12, Auxiliar Steam System, NIN2SNUBBASH339, Clas 3 S. (a) Applicable Construction Coda AISC- 1969 Edition, N/A .,Addenda, N/A Code Case (b) Applicable Edition of Section Xl Used for Repair/Replacement Activity 2001 Edition. 2003 Addenda (c) Applicabie Section Xl Code Case(s) N/A
6. Identification of Components National ASME Coda Name of Name of Manufacturer Board Year Corrected, Removed, Stamped (Yes or Component Manufacturer Serial No. No. Other Identification Built or installed No)

Hydraulic ITT Grlnnell 15530 N/A FNP2-29 1981 Removed No Snubber Hydraulic Anvil 39482 N/A SNVA10090817 2014 Installed No Snubber

7. Description of Work Reploced snubber as a scheduled upnaradeoer ED) C091569201 B. Test Conducted: Hydrostatic [] Pneumatic 0] Nominal Operating Pressure 0] Exempt []

Other 0] Pressure _______psi Test Temp. _________

FORM NrS-2 (Back)

9. Remarks Cert[ifcateof Conformance. VT.3 Examination Applicable Manufacturer's Data Reports to be attached WON SNiC55s657 CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and that this realacement conforms to the rules of the ASME Cods, Section XI. repair or replacement Type Code Symbol Stamp N/A Criiteof Authorization*1o N/A Expiration Date N/A Signed f,~o*UL(2(l,4*;* /**P-i- A4 Date _______- __-

Owner or Owner's Designees CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Beliler and Pressure Vessel Inspectors and the state or Province of Florida and employed by HSB Global Standards of Hartford. CT have inspected the qomponents described in this Owner's Report during the period p3/a4/:-Zc,a'-

to .. bs*/ */I/ 2*'" . and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code,Section XI.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer SHALL be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection, Commisions .).z-4,O3AiJ,. . , L-" -'

Inspector's Signtafurs National Board, State, Province and Endorsements Date D 14/,

  • -2 pt*

Page 2 of 2

FORM NIS-2 OWNER'S REPORT FOR REPAIR/REPLACEMENT ACTIVITY As Req uired By The Provisions Of The ASME Code Section Xl

1. Owner Southern Nuclear Operating Company Date: 4/28/2015 Name Sheet 1 of 2 40 InvernessCtr Pkwy, Birmineham, AI. 35242 Address Unit FNP Unit 1
2. Plant WON SNC 555661 Joseph M. Farley Nuclear Plant (FNPJ Repair/Replacement Organization P.O. No., Job No., etc.

Name Type Code Symbol Stamp N/A ________

7'386 N. State Hwy 95. Co~lumbia, AL 36319.

- Address Authorization No. N/A"

3. Work Performed By Expiration Date N/A FNPMaintenance Department Name 7388 N. State#Hwy 95. Columbia, Al. 36319 Address
4. Identification of System E13. Con tainment Spray, Q.1E13SNUBBCS2R131. Class 2
5. (a) Applicable Construction Code AISC-1969 Edition, N/A Addenda, N/A Code Case (b) Applicable Edition of Section Xl Used for Repair/Replacement Activity 2001 Edltlon. 2003 Addendo (c) Applicable Section Xl Code Case(s) N/A
6. Identification of Components National ASME Code Name of Name of Manufacturer Board Year Corrected, Removed, Stamped (Yes or Component Manufacturer Serial No. No. Other Identification Built or Installed No)

Hydraulic ITT Grinnell 24178 N/A FNP2-29 1977 Removed No Snubber Hydraulic Anvil 39496 N/A 3NA10090817 2014 Installed No Snubber

7. Description of Work Replaced snubberas a scheduled upgrade per Equivalency DeterminationC092050401
8. Test Conducted: Hydrostatic El Pneumatic El Nominal Operating Pressure El Exempt 0]

Other [] Pressure________psi Test Temp. _____F___

\ I

FORM NIS-2 (Back)

9. Remarks Certificate of Compliance. VT-3 Examination Applicable Manufacturer's Data Reports to be attached Wo# SNC555661 CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and that this repolacement conforms to the rules of the ASME Code, Section Xl. repair or replacement Type Code Symbol Stamp N/A Certificate of Authorization No. N/A Expiration Date N/A signed*-/AL-* ,eo ,*lA1Z/ 12X'!I, *-* /utaoA,.' i,,,i,
  • Date '.+- .. 2'- / *'Z Owner or Owner's Designee CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vesset Inspectors and the state or Province of ;Florida and employed by HSB Global Standards of Hartford. CT have inspected the. components described in this Owner's Report during the period L/I 7/2.-ol, to . o*/*1/Zc. a ."and state that to the best of my knowledge and belief, the Owner has perfernmed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section XL.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the inspector nor his employer SHALL

(§> be liable in any manner for any personal injury er property damage or a less of any kind arising f rem or connected with this

  • ')inspection.

Inspector's Signal1re National Board, State, Province and Endorsements Date /,/ o,"

FORM NIS-2 OWNER'S REPORT FOR REPAIR/REPLACEMENT ACTIVITY As Required By The Provisions Of The ASME Code Section Xl 1.Owner Southern Nuclear Operatiniq Company Date 4/30/20 15 Name 40 Inverness Ctr Pkwv, Birminglham, AL, 35242 Sheet of 2 Address

2. Plant Joseph M. Farley Nuclear Plant (FNP) Unit FNP UNIT 1 Name 7388 NV.State Hwy 95. Columbia, AL 36319 WO#: SNC555666 Address RepairlReplacement Organization P.O. No., Job No., etc.
3. Work Performed by FNP Maintenance Department Type Code Symbol Stamp N/A Name Authorization N/A No.

7388 N. State Hwy. 95, Columbia, AL. 36319 Expiration N/A Date Address

4. Identification of System E13, Containment Spray System, Q1E13SNUBBCSR294, Class 2
5. (a) Applicable Construction Code AISC 1969 Edition, N/A Addenda, N/A Code Case (b) Applicable Edition of Section Xl Used for RepairlReplacement Activity 2001 ED / 2003 Add.

(c) Applicable Section XI Code Case(s) N/A

6. Identification Of Components National Corrected, ASME Code Name of Name of Manufacturer Board Other Year Removed, or Stamped Component Manufacturer Serial No. No. Identification Built Installed (Yes or No)

HYDRRAULIC ITT GRINNELL 26729T N/A P0: 10323 1983 REMOVED NO SNUBBER ____________

HYDRAULIC ANVIL 39495 N/A P0: SNA 10090817 2014 INSTALLED NO SNUBBER _______________

7. Description of Work Replaced snubber as a scheduled upg/rade.
8. Test Conducted:

Other El L]

Hydrostatic Pneumaticf]

Pressure _____psi NominalTestOperating Temp. Pressurefl

______ 0 F

Exempt []

Page 1 of 2

FORM NIS-2 (Back)

Certificate of Compliance, VT-3 Examination. Equivalency Determination: C092050401 Rev. 3.0 NRemarks Applicable Manufacturer's Data Reports to be attached 9.

SNC555666 CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and that this Replacement conforms to the rules of the ASME Code,Section XI.

Type Code Symbol Stamp N/A Certificate of Authorization No.

N/A Expiration Date N/A Signed cy ]1 i* -c3%C4 (C.*,

,J Date .1-_/_ /

Owner or Owner's Designee, Title "'

CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the state or Province of Florida and employed by HSB Global Standards of Hartford, CT have inspected the components described in this Owner's Report during the period oz./ 23/,e-O eS;"

to___ *</z*7..1*- ,and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section Xl.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

4 4

  • ' *S lJo.* Commissions *2.G,[-)3At*A , 4?-L '-"

Inspector's Signature (' National Board, State, Province and Endorsements Date Oz-J.*/ * '-

Page 2 of 2

FORM NIS-2 OWNER'S REPORT FOR REPAIR/REPLACEMENT ACTIVITY As Required By The Provisions Of The ASME Code Section XI

1. Owner Southern Nuclear OperatingCompany Date 4/27/2015 Name 40 Inverness Cir Pkwy Birmiinpham, AL, 35242 Sheet 1 ot 2 Address
2. Plant Joseph M. Farley NuclearPlant (FNP) Unit FNP UNIT 1 Name 7388 N. Slate Hwy 95, Columbia, AL 36319 WO#: SNC555675 Address RepalrlReplacement Organization PO. No., Job No,, etc.
3. Work Performed by FNP Maintenance Department Type Code Symbol N/A Stamp__________ __

Name Authorization N/A No. _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

7388 NV.Stale Hwy. 95, Columbia, AL. 36319 Expiration N/A Date Address

4. Identification of System E21, Chemical Volume ControlSystem. QIE2ISNUBBCVCRI152, Class2
5. (a) Applicable Construction Code AISC 1969 Edition, N/A Addenda, N/A Code Case (b) Applicable Edition of Section XI Used for RepairlReplacement Activity ;2001 E*D / 2003 Add. .

(c) Applicable Section XI Code Case(s) N/

6. Identification Of Components National -Corrected, ASME code Name of Name of Manufacturer Board Olher Year Removed, or Stamped Component Manufacturer Serial No. No. Identification Built , Installed (Yes or No)

HYDRAULIC ITT GRINNELL 14678 N/A P0:. 20825 1983 REMOVED NO SNUBBER __________ ___

HYDRAULIC ANVIL 39479 N/A' PD. SNA 10090817 2014 INSTALLED NO SNUBBER______

7. Description of Work Replaced snubber as a scheduled upgrade
8. Test conducted: Hydrostatic [] Pneumaticf-- NominalTest Operating Pressuref'] Exempt[*]

Other [] Pressure ____psi Temp._____

Page 1 of 2

FORM NIS-2 (Beck)

9. Remarks Certificate of Compi~ance. VT-3 Examination. Equivalency Determination: C092099701 Rev. 4.0 Appl:icable Manufacturer's Data Reports to be attached SNC555675 CERTIFICATE OF COMPLIANCE .n We certify that the statements made in the report are correct and that this Replacement conforms to the rules of the ASME Code, Section Xl.

Type Code Symbol Stamp N/A Certificate of Authorization N/A Expiration Date "N/A Signed .,/-,u2-4*-9;. /tc. .D r* Date

  • 1__j '5 owner or Owner's Deelgntee', ltle -

~CERTIFICATE OF INSER VICE INSPECTION I, the undoraigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel inspectors and the state or Province of Florida and employed by HSB Global Stan~dards of . ator.C

~~~~~have inspected the components described in this Owner's Report during the period *>/**/ro

__ to._-,-___7_c*". . and state that to the best of my knowledge and belief, the Owner: has performed

'aminations and taken corrctve measures described in this Owner's Report In accordance with the requirements of the ASME Code,
jctlon xl.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

-

  • fr *. -- o.
  • Commissions *2-ao:3Au%!c, 4*-#*'

Inspector's Signature -/National Board, State, Province and Endorsements m IO m Page 2 of 2

FORM NIS-2 OWNER'S REPORT FOR REPAIR/REPLACEMENT ACTIVITY As Required By The Provisions Of The ASME Code Section XI

1. Owner Southern Nuclear Operatingq Company Date: 4/28/2015

©) Name 40 Inverness CtrPkwvt Binninpham, AL. 35242 Sheet 1 of 2 Address Unit FNP Unit I

2. Plant Joseph M. Farley Nuclear Plant (FNPJ Repair/Replacement Organization P.O. No., Job No., etc.

Name

.73868N. State Hwy 95. Columbia, AL. 36319 Type Code Symbol Stamp N/A Address Authorization No. N/A

3. Work Performed By Expiration Date N/A

_ NP MaintenanceDepartment Name 738.8 N. State Hwy 95, Columbia. Al. 36319 Address

4. Identification of System E21. Chemical Volume Control System. QIE21SNUB.BCVCR222. Class 2
5. (a) Applicable Construction Code AISC- 1969 Edition, N/A Addenda, N/A Code Case (b) Applicable Edition of Section Xl Used for Repair/Replacement Activity 2001 Editlon. 2003 Addenda (c) Applicable Section Xl Code Case(s) N/A
6. Identification of Components ___________

National ASME Code Name of Name of Manufacturer Board Year Corrected, Removed, Stamped (Yes or Component. Manufacturer Serial No. No. Other Identification Built or installed No)

Hydraulic IT[ Grlnnell 15515 N/A FNP222 1977 Removed No Snubber

©) Hydraullc Snubber Anvil 39486 N/A SNA 10090817 2014 Installed No

7. Description of Work Replaced snubber as a scheduled up grade per ED C092099701
8. Test Conducted:

Hydrostatic [] Pneumatic El Nominal Operating Pressure 0] Exempt []

Other [] Pressure _______psi Test Temp. ________"F s-j

FORM NIS-2 (Sack)

9. Remarks Certificateof Conformance. VT-3 Examination W.N5N55590Applicable Manufacturer's Data Reports to be attached CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and that this replacement conforms to the rules of the ASME Code,Section XI. repair or replacement Type Code Symbol Stamp W/A Criiteof Authorztion'No. N/A Expiration Date N/A Owner or Owner's Designee' CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the state or Province of Floridal and employed by HSB GlobalStandards of Hartford. C.T have inspected the components_ described in this Owner's Report during the period 69 ?,/ *' *- /
  • to /

i5"I-J Z-c*" and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section Xl.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer SHALL

  • be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this

-" inspection.

V*'3:A-,? S '*

  • Commisions 1 72-.Lo*A)tJc-, *L44-/"-

Inspector's Signature" National Board, State, Province and Endorsements

(..

Page 2 of 2

©AK FORM NIS-2 OWNER'S REPORT FOR REPAIRIREPLACEMENT ACTIVITY As Required By The Provisions Of The ASME Code Section Xl

1. Owner Southern Nuclear OperatingCompany Date Name 40 Inverness Ctr Pkwy, Birmingham, AL, 35242 4/27/20T15 Sheet I of 2 Address
2. Plant Joseph M. Farley Nuclear Plant (FNP)

Unit FNPUNIT1 Name 7388 N. State Hwy 95, Columbia,AL 36319 WO#:'SNC555691 Address RepairlReplacement Organization P.O. No., Job No., etc.

3. Work Performed by FNP Maintenance Department Type Code Symbol Stamp N/A Name Authorization N/A No.

7388 N. State Hwy. 95. Columbia, AL. 36319 Expiration N/A Date Address E21. Chemical Volume Control System, QI E21SNUBBCVCR264, Class 2

4. Identification of System
5. (a) Applicable Construction Code AISC 1969 Edition, N/A Addenda, N/A Code Case (b) Applicable Edition of Section Xl Used for Repair/Replacement Activity 2001 ED / 2003 Add.

(c) Applicable Section Xl Code Case(s) N.(&..A .

6. Identification Of Components ul Intale Y- - -rNo N.

National Ietfcto ASME Code

" -o pnn auatrr SralN. Corrected,

-_ Name of Name of Manufacturer Board Other Year Removed, or Stamped Component Manufacturer Serial No. No. Identification Built Installed (Y~5 or NO)

HYDRUALIC /IT GRINNELL 15517 N/A P0: FNP-222 1977 REMOVED NO SNUBBER ____________ _______ _________

HYDRAULIC ANVIL 39475 N/A P0: SNAWO9O8I7 2014 INSTALLED NO SNUBBER ____________ _______

7. Description of Work I
8. Test Conducted: Hydrostatic Other [] E] Pneumatic['-

Pressure ______psi NominalTestOperating Temp. PressureE]

____F__

Exemptjj' Page 1 of 2

FORM NIS-2 (Back) 0 Certificate of Compliance, VT-3 Examination. Equivalency Determination: C092099701 Rev. 4.0 NRemarks Applicable Manufacturer's Data Reports to be attached 9.

SNC555691 CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and that this. Renlacement conforms to the rules of the ASME Code, Section Xl.

Type Code Symbol Stamp N/A Certificate of Authorization N/A No.

Expiration Date N/A Signed Signed ,tAAA ~ Dates I

  • i l l i *I

-j Owner or Owner's Designee, Title m

w CERTIFICATE OF INSER VICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel inspectors and the state or Province of Florida and employed by HSB Global Standards of HtqrCT have inspected the components described in this Owner's Report during the period e>!o-*-O "

to ¢*/i* *>1 " ,and~ state that to the best of my knowledge and belief, the Owner has performed

(}zminations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Cede, Kr ,ction XI. .

I By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shell be liable in any manner for any personal injury or property damage orea loss of any kind arising from or connected with this inspection.

Commissions I 2-,03,4# i .(c.*., -

Inspector's Signature - National Board, State, Province and Endorsements Date 0-*/: -

Page 2 of 2

FORM NIS-2 OWNER'S REPORT FOR REPAIR/REPLACEMENT ACTIVITY As Required By The Provisions Of The ASME Code Section Xl

1. Owner Southern Nuclear OperatinaCompany Date: 4/21/2015 Name Sheet 1 of 2

.40 Inverness Ctr Pkwv. Birmingham, Al. 35242 Address Unit FNP Unit 1 Joseph M. FarleyNuclear Plant (FNPJ WO#I SNC 555692

2. Plant Name Repair/Replacement Organization P.O. No., Job No., etc.

Type Code Symbol Stamp N/A 7388 NV.State Hwy 95. Columbia. Al. 36319 Address Authorization No.

3. Work Performed By N/A Expiration Data N/A FNPMaintenance Deoartment Name

.. 7308 N. State Hwy 95. Columbia, AL. 36319 Address

4. Identification of System E21, High Head Safetv IniectionI/CVCS. QIF-21SNUBB.CVCR447, Class 2
5. (a) Applicable Construction Code AISC-1969 Edition, N/A Addenda, N/A Code Case (b) Applicable Edition of Section Xl Used for Repair/Replacement Activity 2001 Edition. 2003 Addenda (c) Applicable Section Xl Code Case(s) N/A
6. Identification of Components___________ ________________

National Corrected, ASME Code Name of Name of Manufacturer Board Year Removed, or Stamped (Yes Component. Manufacturer Serial No. No. Other Identification Built Installed or No)

Hydraulic lITT Gnnnel 19016 N/A FNP2-29 1981 Removed No Snubber Hydraulic Anvil 39500 N/A SNVA 10090817 2014 Installed No Snubber

7. Description of Work Replaced snubberaspscheduled ucarado.
8. Test Conducted: Hydrostatic []

Other []

Pneumatic []

Pressure - psi Nominal Operating Pressure Test Temp.

0] Exempt []

"F____

Page 1 of 2

FORM NIS-2 (Back)

9. Remarks Certificate of Comriliance. VTI-3 Examination, and Equivalency Oetermination C092099701 Re)v.4.O Applicable Manufacturer's Data Reports to be attached SNC555*92 WO#

WON SNC555692 CERTIFICATE OF COMPLIANCE We certify that the statements mode in the report are correct and that this replacement conforms to the rules of the ASME Code, Section XI1 repair or replacement Type Code Symbol Stamp N/A Certificate of Authorization No. N/A Expiration Date N/A Owner or Owner's Designee ._

CERTIFICATE OF INSER VICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure VessellInspectors and the state or Province of Florida and employed by HSB Global Standards of I Ij*arttord.CT have inspected the c~mponents described in this Owner's Report during the period

  • 4 -/jI /7o J*

to 0 *-*/;o, S'- . and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section Xl.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer SHALL be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

~Db~I~ Lt Commisions l'L-,o.A.,LC R',-44,-s Inspector's Signature National Board, S~tate, Province and Endorsements Date Page 2 of 2

FORM NIS-2 OWNER'S REPORT FOR REPAIR/REPLACEMENT ACTIVITY As Required Sy The Provisions Of The ASME Code Section XI

1. Owner Southern Nuclear Operatingq Company Date: 5/2/2015 Name Sheet ___________of 2 40 Inverness CtrPkwv, Birmingham, Al. 35242 Address Unit FNP Unit I WO# SNC 555693
2. Plant Joseph M. FarleyNuclear Plant (FNP)

Name Repair/Replacement Organization P.O. No., Job No., etc.

Type Code Symbol Stamp 7388,N. State Hwy 95. Columbia. Al. 36319 N/A ______ _

Address Authorization No.

3. Work Performed By N/A Expiration Date Name 7388 NV.State Hwy 95. Columbia, Al. 3631,9 Address
4. identification of System E21. High Heed Safety Iniection/Chemical Volume Control System. O1E21SNlBBC.VCSR?515. Class 2 S. (a) Applicable Construction Code AISC.1969 Edition, NU/A , Addenda, N/A Code Case (b) Applicable Edition of Section XI Used for Repair/Replacement Activity, 2001 Edition. 2003 Addenda (cJ Applicable Section XI Code Case(s) P1/A
6. Identification of Components _______

National ASME Cods Name of Name of Manufacturer Board Year Corrected, Removed, Stamped (Yes or Component Manufacturer Serial No. , No. Other Identification BuIlt or installed No3 Hydraulic ltT Grinnell 14013 N/A 20825 1983 Remoued Na Snubber Hydraulic Anvil 39480 ND/A SNA 10090817 2014 lastal~led No Snubber

7. Description of Work Reploced snubbernasoascheduledunaradpe r EauiatenrsyDetermInationC092099701
8. Test Conducted: Hydrostatic [] Pneumatic El Nominal Operating Pressure El Exempt []

Other [] Pressure ________psi Test Temp. ________ F i

FORM NIS-2 (Back)

9. Remarks Ce~rt[ilateof Compliance, V1-3 Examlnatlon Applicable Manufacturer's Data Reports to be attached CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and that this reolacement conforms to the rules of the ASME Code, Section Xl. repair or replacement Type Code Symbol Stamp N/A Cetfo
  • N/A Expiration Date N/A Owner or Owner's Designee CERTIFICATE OF INSERVICE INsPEcTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the state or Province of Florida and employed by ISB. Global.Stan~dards* of .. .Hartford, CT have inspected the components described in this Owner's Report during the period f o4-Io'7/-o *c-,

to *i *" 2. * / 2--o I* , and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section Xl.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer SHALL be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

Inspector's Signature National Board, State, Province and Endorsements Date 0*/*** "

Page 2 of 2

FORM NIS-2 OWNER'S REPORT FOR REPAIR/REPLACEMENT ACTIVITY As Required By The Provisions Of The ASME Code Section XI

1. Owner Southern Nuclear Oneralina Comp~anv Date: 4/21/'2015 Name Sheet 1 of 2 40 Invmernes Cir Pkwy. Binfnineham. Al. 35242

........... TT ........

  • I ......... 1. -;,-. - -i ......... Unit FNP Unit I ___

Address wfAl't C*l,-l ca*1:7

2. Plant .Insnnh A. Fa'rley Nuclear Plant IFNPI Repair/Replacement Organization P.O. No., Job No., etc.

Name 7388 N. State Hwy 95. Columbia, AL. 36319 Type Code Symbol Stamp N/A Addrses Authorfiatlon No. N/A

3. Work Pedtormed By Expirtlon Date N/A FNP Maintenance Denariment Name 7388 N. State Hwy 95, Columbia, Al. 36319 Address
4. Identification of System El1. Residualteat Removal/Low HeadSafaetv Inlection. GIEIISNUBBRHRRA9A. Class 2
5. (a) Applicable Construction Code ... AISL0-I96 Edition, N/A Addenda, N/A Code Case (b) Applicable Edition of Section Xl Used for Repair/Replacement Activity 2001 Edition. 2003.Addenda (c) Applicable Section Xi Code Case(s) N/A
6. Identification of Componentas _____ ________

INational Corrected, ASME Code Name of Name of Manufacturer Board Year Removed, or Stamped (Yes Component Manufacturer Serial No. No. Other Identification Built Installed or No)

Hydraulic ITT Gnnnal 12875 NL/A PO#20825 1983 Removed No Snubber Hydraulic Anvil 39501 N/A SVAM 10090817 2014 Installed No Snubber

7. Description of Work Reolaced snubber as a scheduled upgrade.

B. Test Conducted: Hydrostatic 0] Pneumatic [] Nominal Operating Pressure 0- Exempt []

Other [] Pressure -_ psi Test Temp. ° Page 1 of 2

FORM NIS-2 (Back)

9. Remarks Certificateof Comp/iance. VT-3 Examination. and Eauivalencv Determinatlion C092*533401 Rev.3.0 Applicable Manufacturer's Data Reports to be attached WO# SNC555707 CERTIFICATE OF COMPLIANCE We certify that the statements snade in the report are correct end that this reelacement conforms to the rules of the ASME Cede,Section XI. repair or replacement Type Cods Symbol Stamp N/A Signed i 2i l r Certificate of Authorization No.
  • 1 Ai NL/A Lt Expiration Date at_ -/'

_-_Date_________

NL/A Owner or Owner's Designee CERTIFICATE OF INSER VICE INSPECTION I, the undersigned, holding a valid commission issued by the Nationel Board of Boiler and Pressure Vessel Inspectors and the state or Province ol Rlorida and employed by . SB Global Standards of . . liard, CT have inspected the cgmponents described in this Owner's Report during the period .. /i /I.oi,'.

to O*'*./2.u I*" . e~nd state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report In accordance with the requirements et tho ASME Code,Section XI.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations end corrective measures described in this Owner's Report. Furthermore, neither the inspector nor his employer SHALL be liable In any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

'Inspector's Signatu'V6 Nationel Board, State, Province and Endorsements Date0 -/./--, "

Page 2 of 2

I..

FORM NIS-2 OWNER'S REPORT FOR REPAIR/REPLACEMENT ACTIVITY As Required By The Provisions Of The ASME Code Section XI

1. Owner Southern Nuclear OperatingCompany Date 4/2/2015 Name 40 Inverness Ctr Pkwy. Birmingham, AL, 35242 Sheet I of 2 Address
2. Plant Joseph M. Farley Nuclear Plant(FNP) Unit FNP UNIT 1 Name 7388 N. State Hwy 95, Columbia, AL 36319 WO#: SNC555 708 Address RepairlReplacement Organization P.O. No., Job No., etc.
3. Work Performed by FNP Maintenance Department Type Code Symbol N/A Stamp Name Authorization N/A No.

7388 NV. State Hwy. 95, Columbia, AL. 36319 Expiration N/A Date Address

4. Identification of System P16, Service Water System, Q1IP16SNUBBSW9R35, Class 3
5. (a) Applicable Construction Code AlSC 1969 Edition, N/A Addenda, N/A Code Case (b) Applicable Edition of Section XI Used for Repair/Replacement Activity 2001 E / 2003 Add.

(c) Applicable Section Xl Code Case(s) N/A......

6. Identification Of Components National Corrected, ASME Code

( )_Nameof Name of Manufacturer Board Other Year Removed, or Stamped

-"uomponeni manuraciurer *enai rio. rO, laenutlicauonl oUll instslleO tree or io)

HYORRAULIC ITT GRIINNELL 16999 N/A P0: FNP-222 1977 REMOVED NO SNUBBER __________________ __ ___

HYDRAULIC ANVIL 39492 N/A PO: SNAI10090817 2014 INSTALLED NO SNUBBER ______________ ____

7. Description of Work Replaced snubber as a scheduled upgrade.
8. Test Conducted: Hydrostatic Other [] 5] Pneumatic[--

Pressure _____psi NominalTest Operating Temp. Pressurefl

______ OF Exempt Fx' Page 1 of 2

FORM NIS-2 (Back)

Certificate of Compliance, VT-3 Examination. Equivalency Determination: C092570501 Rev. 3.0 NRemarks Applicable Manufacturer's Data Reports to be attached 9.

SNC555708 CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and that this Replacement conforms to the rules of the ASME Code, Section Xl.

Type Code Symbol Stamp N/A Certificate of Authorization No.

N/A Expiration Date N/A Signed Date "- -

Owner's Designee, or Owner's Title 'J Owner or Owner Designee, 'title N~

CERTIFICATE OF INSER VICE INSPECTiON I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel inspectors and the state or Province of Florida *and employed by .HSBGlobal Standards of H rtford, CT

.. a~ve inspected the components described in this Owner's Report during the period /,.--,.,,-

to-/i.j.oti" to____'. , and state that to the best of my knowledge and belief, the Owner has performed

( xamlnations end taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Byti gnngXlthscriiaenihrteisetrnrhsepoe mksaywratepesdo mlecnenn h B(yiosinn hscriiaenihe h npco o mlye ae n arny xrssdo mlecnenn h examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

    • ==*..*

1* F_.* * * ~Commissions t a-i=0,sA ,i4 .lZ-'/'4'-

. . .Inspector's Signature-" -) - National Board, State, Province and Endorsements Oata~ j/~

  • K)

Page 2 of 2

0 FORM NIS-2 OWNER'S REPORT FOR REPAIR/REPLACEMENT ACTIVITY As Required By The Provisions Of The ASME Code Section XI

1. Owner Southern Nuclear Operating/Cmany Date 4/28/2015 Name 40 Inverness Ctr Pkwy, Birmingham, AL, 35242 Sheet 1 of2 Address
2. Plant Joseph M. Farley Nuclear Plant(FNP) Unit FNP UNIT 1 Name 7388 N. State Hwy 95, Columbia, AL 36319 WO#: SNC555 709 Address Repair/Replacement Organization P.O. No., Job No., etc.
3. Work Performed by FNP MaintenanceDepartment Type Code Symbol N/A

_____________________ Stamp ______________

Name Authorization N/A No.__________________

7388 N. State Hwy. 95, Columbia, AL. 36319 Expiration N/A

_______________________________ Date ______________________

Address

4. Identification of System P17, Component Cooling Water System, QIP17SNUBBCCWR380,Class 3
5. (a) Applicable Construction Code AISC 1969 Edition; N/A Addenda, N/A Code Case (b) Applicable Edition of Section Xl Used for Repair/Replacement Activity 2001 ED / 20.03 Add.

(c) Applicable Section Xl Code Case(s) .. N/A

6. Identification Of Components
7. Description of Work Replaced snubber as a scheduled upgrade.
8. Test Conducted: Other 5] ri Hydrostatic Pressure Pneumaticf--

______psi NominalTest Operating Pressuref'-

Temp._______ ExemptjIx' N

'1 Page 1 of 2

O FUKM NlIS-2 (Back)

9. Remarks Certificate of Compliance, VT-3 Examination. Equivalency Determination: C091933501 Rev. 4.0 Applicable Manufacturer's Data Reports to be attached SNC555709 CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and that this Replacement conforms to the rules of the ASME Code, Section Xl.

Type Code Symbol Stamp N/A Certificate of Authorization N/A Expiration Date N/A Signed *  ? *'

  • _.*,jj
  • Date :S.-/ , ,*-

Owner or Owner's Designee, title CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Bailer and Pressure Vessel Inspectors and the state or Province of Florida and employed by HSBGlobal Standards of Hrfd.CT j.. ave inspected the components described in this Owner's Report during the period *$/: /*I*

____to 1 L,,o L/ .o.1" and state that to the best of my knowledge and belief, the Owner has performed

- *aminations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code,

  • ction Xl.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described In this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

4 jZbA~

5 Jg~~ omisios A~~3~c R4 Inspector's Signature National Board, State, Province and Endorsements Date0> O -,0-"

Page 2 of 2

FORM NIS-2 OWNER'S REPORT FOR REPAIRIREPLACEMENT ACTIVITY As Required By The Provisions Of The ASME Code Section XI

1. Owner Southern Nuclear OPeratingCompany Date: 4/28/2015 Name Sheet 1 of 2 40 Inverness Ctr Pkwy, Birmingham. Al. 35242 Address Unit woe UNit571
2. Plant WO# SNC 555710 Joseph M. FarleyNuclear Plant (FNP) Repair/Replacement Organization P.O. No., Job No., etc.

Name Type Code Symboi Stamp N/A 7388 N. state Hwy 95. Columbia, AL. 36319 Address Authoriztrion No.

3. Work Performed By N/A Expiration Date

.. FNP MaintenanceDeoartment N/A Name 7388 N. State Hwy 95. Columbia, Al. 36319 Address

4. Identification of System E13. ContainmentSpray System, QIE13SNUBBCSR142A. C~lass2
5. (a) Applicable Construction Code AISC- 1969 Edition, N/A Addenda, N/A Code Case (b) Applicabie Edition of Section Xi Used for Repair/Replacement Activty 2001 Edltion. 2003 Addenda (c) Appilicable Section Xl Code Case(s) N/A
6. Identification of Components Nationai ASME Code Name of Name of Manufacturer Board Year Corrected, Removed, Stamped (Yes or Component Manufacturer Serial No. No. Other Identification Built or Instalied No)

Hydraulic ITT Grinneli CSR-142 N/A FNP222 1974 Removed No Snubber Hydraulic Anvil 39502 N/A SNVA10090817 2014 Installed No Snubber

7. Description of Work Replaced snubberas a scheduled upqrudeper ED)C092050401
8. Test Conducted: Hydrostatic 0] Pneumatic 0] Nominal Operating Pressure 0] Exempt []

Other [] Pressure _______psi Test Temp. ________"F

FORM NIS-2 (Back)

9. Remarks Certificate of Conformance. VT-3 Examination Applicable Manufacturer's Data Reports to be attached

.WO# $NC5.55710 CERTFIRCATE OF COMPLIANCE We certify that the statements made in the report are correct and that this repilacement conforms to the rules of the ASME Code, Section Xl. repair or replacement Type Code Symbol Stamp N/A Certificate*uoz*to/** i~so N/A Expiration Data N/A Signed SoMGoI*J CitD,II,w.* A.-J~t .- jpi- AA3,- Date .S-f - <-

Owner or Owner's Designee

_ - CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boilter and Pressure Vessel Inspectors and the state or Province of Florida and employed by. HSB Global Standards of .Hartford. CT.

have inspected tpe popiponents described in this Owner's Report during the period. 03 I 0 (ZO I-* *'

to tJ* i"/I Z*./ I and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described In this Owner's Report in accordance with the requirements of the ASME Code,Section XI.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer SHALL be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection. _____

T2~e~i Commisions Commisions ~zAec,34j ,.I C. R-

\*'(o*3*/p*C., q

  • ¥ *4*.""

SInspector's Signatu* National Board, State, Province and Endorsements Date 0 g'/)4* *--2., ';

Page 2 of 2

FORM NIS-2 OWNER'S REPORT FOR REPAIRIREPLACEMENT ACTIVITY As Required By The Provisions Of The ASME Code Section Xi

1. Owner Southern,Nuclear Oparatina Company Date: 4/28/12015 Name Sheet 1 of _ 2

,40 Inverness; Ctr Pkwy, Birmingham,. Al. 35242 Address Unit FNP Unit 1 Joseph M. FarleyNuclear Plant (FNP) WO# SNC 555711

2. Plant Name Repair/Replacement Organization P.O. No., Job No., etc.

Type Code Symbol Stamp 7388 N. State Hwy 95. Columbia. AL 36319 N/A Address Authorization No.

3. Work Performed By N/A Expiration Date N/A FNP Maintenance Deaartment Name 7388 N. State Hwy 95. Columbia. Al. 36319 Address
4. identification of System E13. Containment Spray. Q1E13SNUBBCSRI42B. Class 2
5. (a) Applicable Construction Code AISC-1969 Edition, N/A Addenda, N/A Code Case (b) Applicable Edition of Section Xl Used for Repair/Replacement Activity 2.001 Editlon* 2003 Addenda_

(C) Applicable Section X!Code Case(s) N/A

6. Identification of Components ____ __________ ___

National ASME Code Name of Name of Manufacturer Board Year Corrected, Removed, Stamped (yes or Component Manufacturer Serial No. No. Other Identification Bulit or Installed No)

Hydraulic ITT"Grinneli 17824 N/A 'FNP-222 1974 Removed No Snubber (2)

Hydraulic Anvil 39505 N/A SNA1009081"7 2014 installed No Snubber

7. Description of Work Replaced snubber as a scheduled upqrode per Equivalency DeterminationC.092050401.
8. Test Conducted: Hydrostatic [] Pneumatic 0] Nominal Operating Pressure 0] Exempt []

Other 0] Pressure ________psi Test Temp. "F_______

0

FORM NIS-2 (Back)

9. Remarks Certificateof Complipnce, VT-3 Examination Applicable Manufacturer's Data Reports to be attached WO# SNC55571 1 CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and that this replacement conforms to the rules of the ASME Code, Section Xl. repair or replacement Type Code Symbol Stamp NL/A Certificate of Authorization No. N/A Expiration Date N/A Owner or Owner's Designee CERTIFICATE OF INSER VICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler end Pressure Vessel Inspectors and the state or Province of Florida and employed by fISB Global Standards of Hartford. CT have inspected the components described in this Owner's Report during the period 03/3 o / Zoi ,"

to tb s-/' /ao S and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section Xl.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the 0 examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer SHALL be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

Commisions ~Vob~Avl4L. ~L44~

Inspector's Signature ttPrvneadEdreet NainlBadI Date

FORM NIS-2 OWNER'S REPORT FOR REPAIR/REPLACEMENT ACTIVITY As Required By The Provisions Of The ASME Code Section XI

1. Owner _ Southern Nuclear OperatingqCompanv Date: 4/28/2015 C) Name Sheet ___________of 2 40 Inverness CtrPkcwv. Birminqham, AL 35242 Address Unit FNP Unit I
2. Plant Joseph M. Far/aey NuclearPlant (FNP) WO# SNC 555713 Name Repair/RePlacement Organization P.O. No., Job No., etc.

Type Code Symbol Stamp 7388 N. State Hwy 95. Columbia. AI. 36319 N/A Address Authorization No.

3. Work Performed By N/A Expiration Date N/A FNP Maintenance Department Name 7388 N. State Hwy 95. Columbia, Al. 36319 Address
4. identfifcation ofSystem E21, CVCS.'QIE21SNUBBCVC.R281, Class 2
5. (a) Applicable Construction Code A15C-1969 Edition, N/A Addenda, _ N/A .Code Case (b) Applicable Edition of Section Xi Used for Repair/Replacement Activity 200.2 Edition. 2003 Addenda (c) Applicable Section Xl Code Case(s) N/A
6. Identification of Components_______________________

National ASME Code Name of Name of Manufacturer Board Year Corrected, Removed, Stamped (Yes or Component Manufacturer Seraia No. No. Other Identification Built or Installed No)

Hydraulic ITT Grinnell 22381 N/A FNP2-29 1977 Removed No Snubber

- Hydraulic Anvil 39485 N/A SNA10090817 2014 "Installed No Snubber

7. Description of Work .Replaced snubber as a scheduled upgrade per Equivalency DeterminationC092099 701
5. Test Conducted: Hydrostatic [] Pneumatic [] Nominal Operating Pressure 0] Exempt []

Other 0] Pressure _______psi Test Temp. "

/

FORM NIS-2 (Back)

9. Remarks Certificate of Compliance. VT-3 Examination Applicabte Manufacturer's Data Reports'to be attached WON SNCS55 713 CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and that this replacement conforms to the rules of the ASME Code, Section Xl. repair or replacement Type Coda Symbol Stamp N/A Certificate of Authorization No. NIA Expiration Date NIA Signed/i-1/,L4*O .Ps.j1JA/*:IL *..,* ... .- ,* Date -*-.

Owner or Owner's Designee i -

CERTIFICATE OF INSERVICE tNSPECTION I, the undersigned, hotding a valid commission issued by the National Board of Boiler and Pressure Vessel tnspectors and the state or Province of Florida and employed by HSB Global Standards; of .Hartford. CT have inspected the components described in this Owner's Report during the period o 3/.z4/ 2-.,**

to o*S/i=-//- Zci* . and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section Xl.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer SHALL be liable in any manner for any personal injury or property damage er a loss of any kind arising from or connected with this inspection.

inspector s Signature National Board, State, Province and Endorsements Date 0'1*/-oa k"-I

FORM NIS-2 OWNER'S REPORT FOR REPAIR/REPLACEMENT ACTIVITY As Required By The Provisions Of The ASME Code Section XI

1. Owner Southern Nuclear Operating/Company Date 2/27/2015 Name 40 Inverness Cir Pkwy, Birminaham. AL, 35242 Sheet of2 Address
2. Plant Joseph M. Farley Nuclear Plant(FNP) Unit FNP UNIT 1 Name 7388 N. State Hwy 95. Columbia, AL 36319 WO#: SNC555716 Address Repair/Replacement Organization P.O. No., Job No., etc.
3. Work Performed by FNP Maintenance Department Type Code Symbol Stamp N/A Name Authorization N/A No.

7388 N. State Hwy. 95, Columbia, AL. 36319 Expiration N/A Date Address

4. identification of System Eli1, Residual Heat Removal, QIE 11SNUBBRHR6R58, Class 2
5. (a) Applicable Construction Code AISC 1969 Edition, N/A 'Addenda, N/A Code Case (b) Applicable Edition of Section Xl Used for Repair/Replacement Activity 2001 EDI/2003 ADD (c) Applicable Section Xl Code Case(s) N/A
6. Identification Of Components National Corrected, ASME Code Name of Name of Manufacturer Board Other Year Removed, or Stamped Component Manufacturer Serial No. No. Identification Built installed IYes or NoI HYDRAULIC ITT GRINNELL 15529 N/A PO: FNP2-29 1981 REMOVED NO SNUBBER _______ ______

HYDRAULIC ANVIL 39484 N/A P0: SNA 10090817 2014 INSTALLED ND SNUBBER ____________________ ____

7. Description of Work Replaced snubber as a scheduled upglrade.
8. Test Conducted: Hydrostatic Other [] E] PneumaticL-Pressure _____psi NominalTestOperating PressureE-Temp.,______ 0 F

Exemptl*]

Page 1 of 2

FORM NIS-2 (Back)

9. Remarks Certificate of Compliance, VT-3 Exam, Equivalency Determination: C092533401 Applicable Manufacturer's Data Reports to be attached SNC55571 6 CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and that this Replacement conforms to the rules of the ASME Code, Section Xl.

Type Code Symbol Stamp N/A Certificate of Authordzation No. N/A Expiration Date N/A

  • '-"Owner or owner's Designee, Title -

CERTIFICATE OF INSER VICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the state or Province of Florida and employed by HSB Global Standards of Ha.torwC

' ~ ~haveinspected the components described in this Owner's Report during the period '(Z.tZI to Qz*/zl: and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section Xl.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

~ ~ ... Commissions ~6A~

National Board, Stat*, Province and Endorsements Date 0 l- ZO ;

Page 2 of 2

FORM NIS-2 OWNER'S REPORT FOR REPAIRIREPLACEMENT ACTIVITY As Required By The Provisions Of The ASME Code Section XI

1. Owner Southern NuclearOperating Company Date Name 40 inverness Ctr Pkwy, Birmingham, AL, 35242 FN/4/20T15 Sheet 1of 2 Address
2. Plant Joseph M. Farley Nuclear Plant(FNP) Unit FNP UNiT I Name 7388 NV.State Hwy 95, Columbia, AL 36319 WO#: SNC555717 Address Repair/Replacement Organization P.O. No., Job No., etc.
3. Work Performed by FNP Maintenance Department Type Code Symbol Stamp N/A Name Authorization N/A No.

7388 N. State Hwy. 95, Columbia, AL. 36319 Expiration N/A Date Address

4. Identification of System Eli1, Residual Heal Removal, Q1E11SNUBBRHR6R68, Class 2
5. (a) Applicable Construction Code AISC 1969 Edition, N/A Addenda, N/A Code Case (b) Applicable Edition of Section Xl Used for Repair/Replacement Activity .2001 ED!12003 ADD (o) Applicable Section XI Code Case(s) N/A
6. Identification Of Components National Corrected, ASME Code Name of Name of Manufacturer Board Other Year Removed, or Stamped Cornponent Manufacturer Serial No. No. Identification Built installed (Yes or No)

HYDRAULIC iTT GRINNELL 26724T N/A P0: 10323 1982 REMOVED NO SNUBBER ______________ __________ ____

HYDRAULIC ANVIL 3,9498 N/A P0: SNA 10090817Z 2014 INSTALLED NO SNUBBER ______ _____ ____________ ___________

7. Description of Work Replaced snubberas a scheduled upgrade.
8. Test Conducted: Hydrostatic [] PneumaticU-- NominalTest Operating Other [] Pressure ______psi Temp. Pressurer-j Exempt[*]

Page 1 of 2

FORM NIS-2 (Back)

9. Remarks Certificate of Compliance, VT-3 Exam, Equivalency Determination: C092533401 Rev. 3.0 Applicable Manufacturer's Data Reports to be attached SNC555717 CERT"IFICATE OF COMPLIANCE We certify that the statements made in the report are correct and that this .,Replacement conforms to the rules of the ASM E Code, Section Xl.

Type Code Symbol Stamp N/A Certificate of Authorization N/A" Expiration Date N/A No. __________________

Owner or Owner's Designee, Title CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the state or Province of Florida and employed by HSB.Global Standar~ds of Hrod.CT

_ ~~~have inspected the components described in this Owner's Report during the period o / /7.

  • tO___ o / -/ , - .and state that to the'best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section Xl.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable In any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

  • ,,q**p** _ Commissions ,Z-b.,* L 4 -

Inspector's Signature (./. National Board3 State, Province and Endorsements Date, ~/ o  ;

Page 2 of 2

FORM NIS-2 OWNER'S REPORT FOR REPAIR/REPLACEMENT ACTIVITY As Required By The Provisions Of The ASME Code Section Xi

1. Owner Southern Nuclear OperatingCompany . Date 4/27/2015.

Name 40 Inverness Ctr Pkwy, Birmingham, AL, 35242 Sheet 1 of 2 Address

2. Plant Joseph M. Farley Nuclear Plant (FNP) Unit FNP UNIT 1 _

Name 7388 NV.State Hwy 95, Columbia, AL 36319 WO#: SNC555719 Address RepairlReplacement Organization P.O. No., Job No., etc.

3. Work Performed by FNP Maintenance Depart rtment Type Code Symbol N/A Stamp______________ __

Name Authorization N/A No.__ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

7388 N. State Hwy, 95, Columbia,,AtL. 36319 Expiration N/A Date _________________________

Address

4. Identification of System E21, Chemical Volume Control System, O1E21SNUBBSIR62, Class 2
5. (a) Applicable Construction Code AISC 1969 Edition, N/A Addenda, N/A Code Case (b) Applicable Edition of Section XI Used for Repair/Replacement Activity 2001 EDI 2003 Add.

(c) Applicable Section Xl Code Case(s) N/A

6. Identification Of Components National Corrected, ASME Code Name of Name of Manufacturer Board Other Year Removed, or Stamped Component Manufacturer Serial No. No. Identification Built Installed (Yes or No)

HYDRUALIC 1F-F GRINNELL 13919 N/A P0: 20825 1983 REMOVED NO SNUBBER ________ __________

HYDRAULIC ANVIL 39481 N/A P0: SNA 10090817 2014 INSTALLED NO SNUBBER___ ___

7. Description of Work Replaced snubber as a scheduled upg/rade.
8. Test Conducted: Hydrostatic Other ] LI Pneumatic[]

Pressure _____psi NominalTest Operating Temp. Pressure[]

Exempt jj]

Page 1 of 2

FORM NIS-2 (Back)

9. Remarks Certificate of Compliance, VT-3 Examination. Equivalency Determination: C101300501 Rev. 2.0.

Applicable Manufacturer's Data Reports to be attached SNC55571 9 CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and that this Reo~lacemenlt conforms to the rules of the ASME Code, Section Xl.

Type Code Symbol Stamp N,/A Certificate of Authorization N'A Expiration Date N/A SindDate /

Owner or Owner's Designee, "r~tle-CERTIFICATE OF INSER VICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the state or Province of FlOrida and employed by HSB G*lObal Standards of H rtf rd T

_____________have inspected the components described in this Owner's Report during the period f ir' t,"

....... to .~ hz!-c I *  ; , and state that to the best of my knowledge and belief, the Owner has performed aminaftions and taken corrective measures described In this Owner's Report in accordance with the requirements of the ASME Code, O5ection XI.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

Inspector's Signature *JNational Board, State, Province and Endorsements Date */*- /.

  • Page 2 of 2

FORM NIS-2 OWNER'S REPORT FOR REPAIR/REPLACEMENT ACTIVITY As Required By The Provisions Of The ASME Code Section XI 1.Owner Southern Nuclear Operating Company Date Name 40 Inverness Cir Pkwy, Birmingham, AL, 35242 4/21/2015I Sheet 1 ot 2 Address

2. Plant Joseph M. Farley Nuclear Plant(FNP)

Unit FNP UNIT I Name 7388 N. State Hwy 95, Columbia, AL 36319 WOIl: SNC555718 Address RepairlReplacement Organization P.O. No., Job No., etc.

3. Work Performed by FNPMaintenance Department Type Code Symbol Stamp N/A Name Authorization N/A No.

7388 N. State Hwy. 95. Columbia, AL. 36319 Expiration N/A Date Address

4. Identification of System El1, ResidualHeat Removal. Q 1E11SNUJBBRHRR 110. Class 2
5. (a) Applicable Construction Code AISC 1959 Edition, N/A Addenda, N/A Code Case (b) Applicable Edition of Section Xl Used for Repair/Replacement Activity 2001 ED I 2003 Add.

(c) Applicable Section Xl Code Case(s) N/A

6. Identification Of Components National Corrected, ASME Code Name of Name of Manufacturer Board Other Year Removed, or Stamped Component Manufacturer Serial No. No. Identification Built Installed (Yes or No)

HYORRAULIC ITT GRINNELL 26735"1"K7668 N/A P0: 10323 1983 REMOVED NO SNUBBER ______ _______ ___ _____ ____

HYDRA ULIC ANVIL 39491 N/A P0: SNA 10090817 2014 INSTALLED NO SNUBBER________ ______ ___

7. Description of Work Reolaced snubber as a scheduled Uggrade.
8. Test Conducted:

Other 5] 5]

Hydrostatic Pneumatic[5 Pressure ______psi NominalTestOperating Pressurer-Temp._______

ExemptS]

Page 1 of 2

FORM NIS-2 (Back)

Certificate of Compliance, VT-3 Examination. Equivalency Determination: C092533401 Rev. 3.0 SNC55e5a1k Applicable Manufacturer's Data Reports to be attached 5NC555715

_ - CERTIFICATE OF COMPLIANCE We certify that the statements madfe in the report are correct and that this Rep~lacement conforms to the rules of the ASME Code,Section XI.

Type Code Symbol Stamp N/A Certificate of Authorization N/A EExpiretion Data No.

N/A Date .

Signed /

Owner or Owner's Designee, Title r~*-.¢¢ CERTIFICATE OF INSER VICE* INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the state or Province of Florida and employed by HSB5 Global StandardsF of. atod CT S have inspected the components described in this Owner's Report during the period .. O4*L.!4Io L

=-Z*

to___ o¢[z/.J " . ,and state that to the best of my knowledge and belief, the Owvner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section Xl.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

Inspector's Signature (-

Commissions A-((

I1 ,~ * '

National Board, State, Province end Endorsements Date O 7'/t IC,*

Page 2 of 2

(P FORM NIS-2 OWNER'S REPORT FOR REPAIR/REPLACEMENT ACTIVITY As Required By The Provisions Of The ASME Code Section XI

1. Owner Southern Nuclear Operating Company Date 4/2/2015 Name 40 Inverness Ctr Pkwy, Birmingham, AL, 35242 Sheet 1of2 Address
2. Plant Joseph M. Farley Nuclear Plant (FNP) Unit FNPUNiT 1

'Name 7388 NV.State Hwy 95, Columbia, AL 36319 WO#: SNC555721 Address Repair/Replacement Organization P.O. No., Job No., etc.

3. Work Performed by FNP Maintenance Department Type Code Symbol N/A

______________________ Stamp_______________

Name Authorization N/A No.____________________

7388 N. State Hwy. 95, Columbia, AL. 36319 Expiration N/A

_____ _____________ Date _________________________

Address

4. Identification of System P16, Chemical Volume Control System, QIE21SNUBBSIR68, Class 2
5. (a) Applicable Construction Code AISC 1969 Edition, N/A Addenda, N/A Code Case (b) Applicable Edition of Section Xl Used for Repair/Replacement Activity 2001 ED 12003 Add.

(c) Applicable Section XI Code Case(s) N/A

6. Identification Of Components EMVDN National NatonaBAMEEod N/

Board PO902518 Conrected, ASME Code Stamped

) Comoonent Name of HYRALC ITGINL Name of Manufacturer 19211 Manufacturer Serial No. No. Other Identification Year Built Removed, or Installed (Yes or No*

HYORRAULIC /iT ORINNELL 19211 Board No.

N/A P0: 20825 1983 (Yes Stamped or No~

REMOVED NO SNUBBER _______________

HYDRAULIC ANVIL 39476 N/A P0: SNA 10090817 2014 INSTALLED NO SNUBBER ____________ __________

7. Description of Work Replaced snubberas a scheduled upgrade.
8. Test Conducted: Hydrostatic Other [] fl PneumaticE1 Pressure _____psi NominalTest Operating Temp. Pressuref]

Exemptfx-"

Page 1 of 2

FORM NJS-2 (Back)

9. Remarks Certificate of Compliance, VT-3 Examination. Equivalency Determination: C101300501 Rev. 2.0 Applicable Manufacturer's Data Reports to be attached SNC555721 CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and that this Replacement conforms to the rules of the ASME Code, Section Xl.

Type Code Symbol Stamp N/A Certificate of Authorization N/A Expiration Date N/A No. _________________

Owner or Owner's Designee, Title

~CERTIFICATE OF INSER VICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and P'ressure Vessel Inspectors and the state or Province of Florida and employed by HSB Global S;tandards; of H Hrtford, CT .

~~~~have inspected the components described inthis Owner's Report during the period *

  • 7."

to o I'/7-/ag , and state that to the best of my knowledge and belief, the Owner has performed Q raminations and taken corrective measures described In this Owner's Report in accordance with the requirements of the ASME Code,

  • ection Xl.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shell be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

  • V*, ___.d-.- Commissions aA*b*AI_ .

'Inspector's Signature National Board, State, Province and Endorsements Date 0*-/13 2 ,I *"

Page 2 of 2

FORM NIS-2 OWNER'S REPORT FOR REPAIR/REPLACEMENT ACTIVITY As Required By The Provisions Of The ASME Code Section XI 1.Owner Southern Nuclear Operatinq Company Date 4/25/2015 Name 40 Inverness Cir Pkwy, Birmlnplham, AL, 35242 Sheet of2 Address

2. Plant Joseph M. FarleyNuclear Plant(FNP) Unit FNP UNIT 1 Name 7388 N. State Hwy 95. Columbia, AL 36319 WO#: SNC555723 Address Repair/Replacement Organization P.O. No., Job No., etc.
3. Work Performed by FNP MaintenanceDepairlment Type Code Symbol N/A

________ Stamp__________ ______

Name Authorization N/A No.__ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

7388 N. State Hwy. 95, Columbia, AL 36319 Expiration N/A

__________ Date _______________________

Address

4. Identification of System E21, Chemical Volume Control System, QIE21SNUBBSIR1 18, Class 1
5. (a) Applicable Construction Code AISC 1989 Edition, N/A Addenda, N/A Code Case (b) Applicable Edition of Section Xl Used for Repair/Replacement Activity 2001 ED / 200,3 Add.

(c) Applicable Section XI Code Case(s) N/A

6. Identification Of Components National Corrected, ASME Code Name of Name of Manufacturer Board Other Year Removed, or Stamped Component Manufacturer Serial No. No. Identification Built Installed ( Yes or No)

HYDRRAULIC ITT GRINNELL 12095 N/A P0: FNP-222 1977 REMOVED NO SNUBBER ______ _______ ___ _____

LOAD STUD MACKSON N/A N/A HT: M82491 2004 -REMOVED " NO NUT ______ ______P0: QP040363 _______________

HYDRAULIC ANVIL 39508 N/A " P0: SNA 10090817 2014 INSTALLED NO SNUBBER __________________ __ ___

7. Description of Work. Replaced snubberas a scheduled upgrade.
8. Test Conducted: Hydrostatic [] Pneumaticr-1 Nominal Operating Pressurefl- Exempt['*

Other [] Pressure _____psi Test Temp. ____ F__

Page 1 of 2

FORM NIS-2 (Back)

9. Remarks Certificate of Compliance, VT-3 Examination. Equivalency Determination: C101300501 Rev. 2.0.

Applicable Manufacturer's Data Reports to be attached SNC555723 CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and that this Replacement conforms to the rules of the ASM E Code,Section XI.

Type Code Symbol Stamp N/A Certificate of Authorization N/A Expiration Date N/A No.

Signed **3(**

uwero uwe'sUslne £ltlDate 4*~

uwner or uwners uesignee, me CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the state:

or Province of Florda¢ and employed by HSB Global Standards; of HctorCT

,have inspected the components described in this Owner's Report during the period *4oS/oI*

to___ o"-/2o ,and state that to the best of my knowledge and belief, the Owner has performed examinations end taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code,Section XI.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

Commissions t2J,,o3Ai.t-, (*L,-, 4 4%

Inspector's Signature" National Board, State, Province and Endorsements Date 0 %"-I( "z.-o, Page 2 of 2

FORM NIS-2 OWNER'S REPORT FOR REPAIR/REPLACEMENT ACTIVITY As Required By The Provisions Of The ASME Code Section X!

1.Owner Southern Nuclear Operating Company . Date 2/2 7/2015 Name 40 Inverness Ctr Pkwy, Birmingham, AL, 35242 Sheet of2 Address

2. Plant .Joseph M. Farley Nuclear Plant (FNP) Unit FNP UNIT I Name 7388 N. State Hwy 95, Columbia, AL 36319 WO#: SNC555726 Address Repair/Replacement Organization P.O. No., Job No., etc.
3. Work Performed by FNP Maintenance Department Type Code Symbol N/A Stamp Name Authorization No. N/A 7388 N. State Hwy. 95, Columbia, AL. 36319 Expiration N/A Date Address
4. Identification of System P16, Service Water, QIP16SNUBBSW439R80, Class 3
5. (a) Applicable Construction Code AISC 1989 Edition, N/A Addenda, N/A Code Case (b) Applicable Edition of Section Xl Used for Repair/Replacement Activity 2001 ED/12003 ADD (c) Applicable Section Xl Code Case(s) N/A
6. Identification Of Components National Corrected, ASME Code Name of Name of Manufacturer Board Other Year Removed, or Stamped Cornponent Manufacturer Serial No. No. Identification Built Installed (Ysor Nol HYDRAULIC I7TTGRINNELL 26726T" N/A P0: 10323 1983 REMOVED NO SNUBBER _____ ___ _____ ____

HYDRAULIC ANVIL 39494 N/A PO: SNA1lO090817 2014 INSTALLED NO SNUBBER _____

7. Description of Work Replaced snubber as a scheduled upgrade.
8. Test Conducted: Hydrostatic [] PneumaticU'- Nominal Operating Pressure[-' Exempt['

Other [] Pressure _____psi Test Temp. ______

Page 1 of 2

FORM NIS-2 (Back)

9. Remarks Certificate of Compliance, VT-3 Exam, Equivalency Determination: C092570501 Applicable Manufacturer's Data Reports to be attached SNC555726 CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and that this Replacementt conforms to the rules of the ASM E Code,Section XI.

Type Code Symbol Stamp N/A Certificate of Authorization No. NV/A Expiration Date N/A

\.~e rOwner's Designee, Title N

CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the state or Province of Florida and employed by HSB Global Standards of Hartford, CT have inspected the components described in this Owner's Report during the period X */{ *7- ZZ to_______o*" and state that to the best of my knowledge and belief, the Owner" has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code,Section XI.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

  • -J'l*-*' *'=-- Commissions ,.740o1Aic, ZL*4* -"

Inspector's Signature National Board, State, Province and Endorsements Date *)-Zo*,*

Page 2 of 2

FORM NIS-2 OWNER'S REPORT FOR REPAIR/RlEPLACEMENT ACTIVITY As Required By The Provisions Of The ASME Code Section Xl

1. Owner Southern NuclearOperatingqCompany Date: 4/28/2015 7© Name

.,40 Inverness Ctr Pktwy. Birmingqham, AL135242 Sheet 1 of 2 Address Unit FNP Unit 1

2. Plant
  • Joseph M. Farley NUclearPlant (FNP) WON SNC 555727 Name Repair/Replacement Organization P.O. No., Job No., etc.

7388 NV.State Hwy 95. Columbia. ALo 36319 Type Code Symbol Stamp N/A Address Authorization No. N/A

3. Work Performed By Expiration Date N/A FNp MaintenanceDepartment Name 7388B N. State Hwy 95. Columbia. AJ. 36319 Address
4. Identification of System. G24. Steam GeneratorSlowdown Treatment.System. 01G.24SNUBBSS4586. Class 2
5. (a) Applicable Construction Code AISC - 1963 Edition, N/A Addenda, N/A Code Case (b) Applicable Edition of Section Xi Used for Repair/Replacement Activity. 2001 Edition. 2003 Addenda (c) Applicable Section Xl Code Case(s) N/A
6. Identification of Components" Nationai ASME Code Name of Name of Manufacturer Board Year Corrected, Removed, Stamped (Yes or Component Manufacturer Serial No. No. Other Identification Built or installed No)

Hydraulic U.sega 61287/67 N/A QP95277 1993 Removed No Snubber 0 Hydraulic Snubber Llsega 31400822/009 N/A SNA100960S9 2014 Installed No

7. Description of Work Replaced snubber as a scheduled uparode
8. Test Conducted: Hydrostatic LIPressure Pneumatic El Nominal Operating Pressure [] Exempt 0]

Other [] _______psi Test Temp. _____F___

K,)

FORM NIS-2 (Back)

9. Remarks Certificateof Conformance, VT-3.Examination Applicable Manufacturer's Data Reports to be attached WOSN5572 CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and that this replacement conforms to the rules of the ASME Code,Section XI. repair or replacement Type Code Symbol Stamp N/A Certificate of Authorization No., N/A Expiration Date N/A Signed I.r.Ž2L\ L* ,iItA* A*i.-+ JA

]r* Date 9* r) I C Owner or Owner's Designee * "

CERTIFICATE OF INSER VICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the state or Province of Florida and employed by HSB Global Standards of Hartford.CT have inspected the components described in this Owner's Report during the period (Y3/ 30 / s-ri *-

to 2>5r/),/7*c 5 , end state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code,Section XI.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer SHALL

() be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this

\u- inspection.

2

  • t]F- .Es* .* - *w. Commisions *2JO3,4 )i~ ._., *L.4 4*--

Inspector's Signature National Board, State, Province and Endorsements Page 2 of 2

FORM NIS-2 OWNER'S REPORT FOR REPAIR/REPLACEMENT ACTIVITY As Required By The Provisions Of The ASME Code Section Xl 1.Owner Southern Nuclear Operating Company Date Name 4/30201 40 Inverness Ctr Pkwy, Birmingh~am, AL. 35242 Sheet I of 2 Address

2. Plant Joseph M. Farley Nuclear Plant(FNP) Unit FNP UNIT 1 Name 7388 N. State Hwy 95, Columbia, AL 36319 WO#f: 8NC555 733 Address Repair/Replacement OrganIzation P.O. No., Job No., etc.
3. Work Performed by FNP Maintenance Department Type Code Symbol N/A Stamp______________ __

Name Authorization N/A No.,__________________

7388 N. State Hwy. 95, Columbia, AL. 36319 Expiration N/A Date Address

4. Identification of System G24,Steam GeneratorBlowdown System, O1G24SNUBBSS4581D, Class 2
5. (a) Applicable Construction Code AISC 1959 Edition, N/A Addenda, N/A Code Case (b) Applicable Edition of Section Xl Used for Repair/Replacement Activity 2001 ED / 2003 A~dd.

(c) Applicable Section Xl Code Case(s) NIA

5. Identification Of Components National Corrected, ASME Code Name of Name of Manufacturer Board Other Year Removed, or Stamped Component Manufacturer Serial No. No. Identification Built Installed (Yes or No)

ADAPTER LISEGA A/ 15-4 N/A P0: QP040462 2004 REMOVED NO PLATE ______ ___________ __

PIVOT MOUNT PSA " 506 N/A P0: FNP-222 1976 REMOVED NO SNUBBER LISEGA N/A N/A TRACE: A3NH 2014 INSTALLED NO PADDLE P0: SNA 10096175 _ _________

4 ~ 1. 4 .6 9 .9 *9~9 I* 9

4. 4 4-4 I
  • 4

& I I 4. .1

7. Description of Work CHANGED PSA REAR BRA CKET TO LISEGA PIVOT MOUNT DUE TO PISTON ROD LENGTH REQUIREMENTS.
8. Test Conducted: Hydrostatic jjJ Pneumaticj]-'

Other [] Pressure _____psi NominalTestOperating Temp. PressureE]

____ F__

Exempt[*

Page 1 of 2

FORM NIS-2 (Back)

Certificate af Compliance, VT-3 Examination.

NRema7ks Applicable Manufacturer's Data Reports to be attached 9.

SNC555733 CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and that this Replacement conforms to the rules of the ASME Coda, Section Xl.

Type Code Symbol Stamp _____ N/A Certificate of Authorization No. N/A Expiration Date N/A Date * .'._ /*

Owner or Owner's Designee, Title "

CERTIFICATE OF INSER VICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the state or Province of Florida and employed by HSB Global Standards of H rtf rd, CT hgve inspected the components described in this Owner's Report during the period o*14I*D"

___ o_ o*/*/.*' and state that to the best of my knowledge and belief, the O)wner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code,Section XI.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

S...Insspector's Signature" 0*

  • National Board, State, Province and Endorsements Date :I, -O Page 2 of 2

FORM NIS-2 OWNER'S REPORT FOR REPAIRIREPLACEMENT ACTIVITY As Required By The Provisions Of The ASME Code Section Xl

1. Owner .. Southern Nuclear OperatinqCompany Date: .514/2015 Name Sheet 1 of . .2 40 Inverness CtrPksw, B~inmingham, Al. 35242 Address Unit .FNP Unit 1 WO# 9NC 555746
2. Plant Joseph SW.FarleyNuclear Plant (FNP) Repair/Replacement Organization P.O. No., Job No., etc.

Name 73GB N. State Hwy 95. Columbia, AL 36319 Type Code Symbol Stamp N/A Address Authorization No.

3. Work Performed By Expiration Date FNP MaintenanceDepartment N/A Name 7388 IVLSitet Hw, 961 (Columhia. ALl 96319 Address
4. Identification of System E21, Hiah Head Safety Iniection/Chemical Volume Control System. GIE21S.NlJBSS4059B. Class 2 S. (a) Applicable Construction Code AISC- 1969 Edition, N/A Addenda,. N/A Code Case Ib) Applicable Edltion of Section Xi Used for Repair/Replacement ActivIty 2001 Editlon. 2003 Addenda (c) Applicable Section Xl Code Case(s) N/A
6. identification of Components National ASME Code Name of Name of Manufac'turer Board Year Corrected, Removed, Stamped (Yes or Component Manufacturer Serial No. No. Other Identification Built or Installed ,No)

Hydraulic Llsego 61287/33 N/A QP950277 1993 Removed No Snubber Hydraulic . Lisega - 31400822/042 N/A SNiL41096059 2014 Installed No Snubber

7. DescriptIon of Work Replaced hydraulic snubber as a scheduled upgrade.
a. Test Conducted: *Hydrostatic 0]Pressure_______psi Pneumatic El Nominal Operating Pressure El Exempt []

Other El Test Temp. ."

FORM NIS-2 (Back)

9. Remarks Certificates o[ Compllance. VI"-3 Examinations Applicable Manufacturer's Data Reports to be attached WON sNC.555746 CERTIFICATE OF COMPLIANCE We certify that the statements made in the report earcorrect and that this replacemeant conforms to the rules of the ASME Code, Section Xl. repair or replacement Type Code Symbol Stamp N/A Certificate of Authorization Ng"*/ . N/A Expiration Date .N/A
  • ', /3.fI][o  :*Owner or Owner's Designee "

CERTIFICATE OF INSER VICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the state or Province of Florida and employed by lISB Global Stan.dards of . Hartford,CT ..

have inspected, the cgmponents described in this Owner's Report during the period *=-os' *-o f'-

to 'fi'-e

.ITo,"- and state that to the best of my knowledge an'd belief, the Owrner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Coda,Section XI.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer SHALL be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

Inspector's Signatue National Board, State, Province and Endorsements Date J*Z"L**tL' Page 2 of 2

FORM NIS-2 OWNER'S REPORT FOR REPAIRIREPLACEMENT ACTIVITY As Required By The Provisions Of The ASME Code Section XI

1. Owner Southern Nuclear OperatingCompany Date 4/24/20 15 Name 40 Inverness Ctr Pkwy, Birminaham. AL. 35242 Sheet 1of 2 Address
2. Plant Joseph M. Farley Nuclear Plant (FNP) Unit FNP UNIT I Name 7388 N. State Hwy 95, Columbia, AL 36319 WO#: SNC555748 Address RepeiriReplacement Organization P.O. No., Job No., etc.
3. Work Performed by FNP MaintenanceDE!partment Type Code Symbol N/A

__________ Stamp_________ _______

Name Authorization N/A No.__ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

7388 N. State Hwy. 95, Columbi*ia, AL 36319 Expiration N/A

___________ Date______________ _______

Address

4. Identification of System E21, Chemical and Volume Control System, QIE21SNUBBSS4O59C,,Class 2
5. (a) Applicable Construction Code AISC 1969 Edition, N/A Addenda, N/A Code Case (b) Applicable Edition of Section XI Used for Repair/Replacement Activity 2001 EDI!2003 Add.

(c) Applicable Section Xl Code Case(s) .. 2 &.A...

6. Identification Of Components National Corrected, ASME Code Name of Name of Manufacturer Board Other Year Removed, or Stamped Component Manufacturer Serial No. No. Identification Built Installed (Yes or No)

HVDRRAULIC LISEGA 61287/73 N/A P0: QP950277 1993 REMOVED NO SNUBBER____

HYDRAULIC LISEGA 31400822/045 N/A P0: SNA 10096059 2014 INSTALLED NO SNUBBER ______ _____ _______ ___ _____ ____

7. Description of Work..Replaced snubberas a scheduled upgrade.
8. Test Conducted: Hydrostatic j] Pneumaticr-' NominalTestOperating Pressurefl Exemptrnx' Other [] Pressure _____psi Temp. ______

Page 1 of 2

FORM NIS-2 (Back)

9. Remarks Certificate of Compliance, VT-3 Examination.

Applicable Manufacturer's Data Reports to be attached SNC555748 CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and that this Replacement conforms to the rules of the ASM E Code,Section XI.

Type Code Symbol Stamp N/A Certificate of Authorization No. N/A Expiration Date N/A Owner or Owner's Designee, Title "

CERTIFICATE OF INSER VICE INSPECTION I, the undersigned, holding a valid commission issued by the National Beard of Boiler and Pressure Vessel Inspectors and the state or Province of Florida and employed by HSB Global StandardsF of H Hatord, CT have inspected the components described in this Owner's Report during the period ,*o/ , "

to_____-_**'- and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section Xl.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

"* '*, *>T.2 ,.*. Commissions I?.jto3,Ai,l1c,44 Inspector's Signature National Board, State, Province and Endorsements Dat,.

Page 2 of 2

FORM NiS-2 OWNER'S REPORT FOR REPAIR/REPLACEMENT ACTIVITY As Required By The Provisions Of The ASME Code Section XI

1. Owner Southorn Nuclear Operating Company Date 4/25/2015 Name 40 Inverness Cir Pkwy. Birmilngham, AL, 35242 Sheet 1of 2 Address
2. Plant Joseph PA.Farley Nuclear Plant (FNP). Unit FNP UNIT 1 Name 7388 N. State Hwy 95. Columbia, AL 36319 WO#: SNC555759 Address RepairlReplacement Organization P.O. No., Job No., etc.
3. Work Performed by FNP Maintenance Department Typo Code Symbol Nt/A

- Stamp _ _ _ _ _ _ _ _ _ _ _

Name Authorization N/A No._________________ _

7388 N. Salte Hwy. 95, Columbia, AL 363319 Expiration N/A Datea______________________

Address

4. Identification of System 821, Steam Generator, QIB21SNUIBBFT414C. Class 1
5. (a) Applicable Construction Code AISC 1969 Edition, N/A Addenda, N/A Code Case (b) Applicable Edition of Section Xi Used for RepairlReplscement Activity 2001 ED)12003 Add.

(c) Applicable Section Xl Code Case~s) Wf..

6. identification Of Components National Corrected, ASMdE Code Name of Name of Manufacturer Board Other Year Removed, or Stamped Cpoet Manufacturer Serial No. No. Identification Built Installed I~sor No)

MECHANICAL PSA 1968 N/A P0.. FNP-222 1973 REMOVED NO SNUBBER _______ _____________________ __ ___

HYDRAULIC LISEGA 31400822/044 N/A P0: SNAI10096059 2014 INSTALLED NO SNUBBER ______ _____ _____

7. Description of Work Replaced snubber as a scheduledupgrade.
8. Teat Conducted:

Other Q] [] Pneumstic[]

Hlydrostatic Pressure ____psi NominalTeat Operating Temp. PressurmO'

_____ F Exemptlj]

Page 1 of 2

FORM NIS-2 (Back)

9. Remarks Certificate of Compliance, VT-3 Exam ination. Equivalency Determination: S-96-O-00225-ED Applicable Manufacturer's Data Reports to be attached SNC555759 CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct end that this Reolacemont conforms to the rules of the ASME Code, Section Xl.

Type Code Symbol Stamp N/A Certificate of Authorization N/A Expiration Date N/A Owner or Owner's Designee, Title CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holdingse valid commission issued by the National Board of Boiler and Pressure Vessel inspectors and the statei or Province of Flordae and employed by 116B Global Standards of Hp~fr.C

-, have inspected the components described in this Owner's Report during the period 1-io/Lir to__ 43/o'-1-,and state that to the boat of my kn~owledge and belief, the Owner has performedt examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section Xl.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shell be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

Inspector's Signature National Board, State, Province and Endorsements Date0///01-Page 2 of 2

FORM NIS-2 OWNER'S REPORT FOR REPAIR/REPLACEMENT ACTIVITY As Required By The Provisions Of The ASME Code Section Xi

1. Owner . Southern Nuclear OperatingCompany Date: 4/28/2015 Name Sheet  ! . of 2 40 Inverness CtrPkwy, Bi~rmi~ngham. Al. 35242 Address Unit FNP Unit 1
2. Plant WO# SNC 555760 Joseph M. Farley Nuclear Plant(FNPJ Repair/Replacement Organization P.O. No., lob No., etc.

Name 73.88 N. State Hwy 95. Columbia, AL. 36319 Type Code Symbol Stamp N/A Address N/A

3. Work Performed By Authorization No.

Expiration Date N/A FNP Maintenance Deo~artment Name 7388 N. State Hwy 95. Columbia. Al. 36319 Address

4. Identification of System E21. Chemical Volume ControlSystem. QI E21SNUBBSS4819. Class2
5. (a) Applicable Construction Code AIC.-1969 Edition, N/A Addenda, N/A Code Case (b) Applicable Edition of Section XI Used for Repair/Replacement Activity 2001 Editlon.2.003 Addenda (c) Applicable Section Xi Code Case(s) N/A
6. Identification of Components_____

S National ASME Code Name of Name of Manufacturer Board Year Corrected, Removed, Stamped (Yes or Component Manufacturer Serial No. No. Other Identification Built or Installed No)

Hydraulic Llsega 99614390/49 N/A QP000283 1993 Removed No Snubber Hydraulic Uisega 31400822/038 N/A SNA10O96059 2014 Installed No Snubber

7. Description of Work _Replaced snubber as a scheduled upqrade
3. Test Conducted: Hydrostatic I] Pneumatic [] Nominal Operating Pressure 5] Exempt []

Other [] Pressure _______psi Test Temp. "

FORM NIS-2 (Seck)

9. Remarks Certliicate of Conformance, VT-3 Examination

~ SNCSS7BOApplicable Manufacturer's Data Reports to be attached CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and that this realacemsnt conforms to the rules of the ASME Code, Section Xl. repair or replacement Type Code Symbol Stamp N/A Certificate of Authoriation No."- N/A Expiration Date N/A Owner or Owner's Designee CERTIFICATE OF INSER VICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the state or Province of Florida and employed by HSB GlobalStandards of Hartforad. CT have inspected the coipponents described in this Owner's Report during the period 03 /3/3I!// i to c*" / 14 4/z-o . and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code,Section XI.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer SHALL (i> be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this Sinspection.

  • Inspector's Signature National Board, State, Province and Endorsements Page 2 of 2

0 FORM NIS-2 OWNER'S REPORT FOR REPAIRIREPLACEMENT ACTIVITY As Required By The Provisions Of The ASME Code Section XI 1, Owner Southern Nuclear O/oeratinqlCompanv Date 4/2 712015 Name 40 Inverness CtrPkwy, Birmingham, AL, 35242 Sheet of 2 Address

2. Plant Joseph MW. Farley Nuclear Plant (FNP) Unit FNP UNIT 1 Name 7388 N. State Hwy 95, Columbia, AL 36319 WO#: SNC555761 Address Repair/Replacement Orgenization P.O. No., Job No., etc.
3. Work Performed by FNP MaintenanceDepartm*ent Type Code Symbol N/A

______ Stamp__________ _____

Name Authordzation N/A No. _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

7388 N. State Hwy. 95, Columbia, AL. *36319 Expiration N/A

_______ Date _______________________

Address

4. Identification of System P17, Component Cooling Water, QIP17SNUBBSS4B84, Class .3
5. (a) Applicable Construction Code AISC 1969 Edition, N/A Addenda, N/A Code Case (b) Applicable Edition of Section XI Used for Repeir/Replacement Activity _ 2001 ED 1 2003, Add.

(c) Applicable Section XI Code Case(s) WA 6, identification Of Components CorecedBASERod

)Nme of -97 REMVEN

( Component PA75 Name of Manufacturer Manufacturer Serial No.

SNational

.Y -IC

/

Board No.

PO FN-2 Other Identification Year Built Removed, or ASME Stamped Samd Code (Yes or No}

HYDRUALIC PSA 759 N/A P0: FNP-222 1973 Installed REMOVED (YesNO or No~

SNUBBER ____________ __________ ___________ _________

HYDRAULIC LISEGA 31400822/037 N/A P0: SNA 10096059 2014 INSTALLED NO SNUBBER _____________ ________________ ________ ____________ __________

7. Description of Work Replaced snubber as a scheduled upgrade.
8. Test Conducted: Hydrostatic Other [] fl Pneumatic Pressure _____PSiP] NominalTest Operating Temp. PressureE]

Exemptlx-]

F__

Page 1 of 2

FORM NIS-2 (Back)

9. Remarks Certificate of Compliance, VT-3 Examination. Equivalency Determination: S-96-0-00225-EO Applicable Manufacturer's Data Reports to be attached SNC555761 CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and that this Reolacement conforms to the rules of the ASME Code,Section XI.

Type Code Symbol Stamp N/A Certificate of Authorization N/A Expiration Date No. N/A

,. m "f. .... -

Sine ALiS~~ AA~ Date **/-)-

Owner or Owner's Designee, Title" "J I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the state or Province of Florida and employed by

-CERTIFICATE OF INSERVICE HSBINSPECTION Global.Standards. of H rtford, CT have inspected the components descdibed in this Owner's Report during the period o* 1=o,;

ito

  • iL +/-L" ., and state that to the best of my knowledge and belief, the Owner has performed
  • '.~minations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code,
  • ibction XI.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

  • -'A*' *'*1 Commissions \2.-*=o3A4,,._ *"*

National Board, Stale, Province and Endorsements Inpco'I Sgaue6

,1 Page 2 of 2

FORM NIS-2 OWNER'S REPORT FOR REPAIRIREPLACEMENT ACTIVITY As Required By The Provisions Of "The ASME Code Section XI 1.Owner Southern Nuclear Operating Company Date 4/21/2015 Nmero 40 Inverness Otr Pkwy, Birmingham, AL, 35242 Sheet __________________ of 2 Address

2. Plant Joseph M. FarleyNuclear Plant (FNP) Unit FNPUNIT1 Name 7388 N. State Hwy 95, Columbia, AL 36319 WO#l. SNC555 790 Address Repair/Replacement Organization P.O. No., Job No., etc.

3.Work Performed by FNP Maintenanc** Department Type Code Symbol NiA Stamp______________ __

Nar ne Authorization N/A No.__________________ _

7388 N. Slate Hwy. 95, Coi) iumbia. AL. 36319 Expiration N/A

_______________ Datae ________________________

Address

4. Identification of System G24. Steam Generator Btowdown Treaament System, QIG24SNUBBSS2O40, Class 2
5. (a) Applicable Construction Code AISC 1969 Edition, N/A Addenda, N/A Code Case (b) Applicable Edition of Section Xl Used for RepalrlReplacement Activity 2001 ED / 2003 Add, (c) Applicable Section XI Code Case(s) WA
6. Identification Of Components National corrected, A
  • SME Code Name of Name of Manufacturer Board Other Year Removed, or Stamped component Manufacturer 8Seral No. No. Identification Built Installed (Yes or No)

MECHANICAL PSA 322 N/A P0: FNP.222 1976 REMOVED NO SNUBBER ____ _____

HEX BOLT PACIFIC "322 N/A ' P0: FNP-222 1976 REMOVED NO' SCIENTIFIC ________

LOAD STUD PACIFIC UNK N/A P0: 0P6915 'f991 REMOVED NO NUT SCIENTIFIC _______

LOAD STUD P*ACIFIC N/A N/A HT:~N2916A 1990 REMOVED NO

_____ SCIENTIFIC P0: 0P5308______

HYDRAULIC LISEGA 31000519/044 N/A P0: SNAI10058521 2014 INSTALLED NO SNUBBER ______ _______

HEX BOLT NOVA N/A N/A I-T: 0577 2014 INSTALLED NO

___________P0: SNA36051-0075 ______

LOAD STUD ANVIL EPS N/A N/A LOT#: 220625 2014 INSTALLED NO NUT _____________P0: SNA 10082179 _ _________

LOAD STLUD MAXSON N/A N/A HT: Gt0506 2005 INSTALLED NO INCORPORATED ______P0: 0P050640 __________ ____

7. Descrdption of Work Replaced snubber as a scheduled Upgrade.
8. Test Conducted: Hydrostatic [] Pneumaticf]

Other [] Pressure _____psi NominalTestOperating Temp. Pressure[]-

______ F Exempt[']

Page 1 of 2

................. I FORM NIS-2 (Back)

Certificate of Compliance, VTI-3 Examination. Equivalency Determination: $96-0-0225, Rev.l.0 NRema7k0 Applicable Manufacturer's Data Reports to be attached 9.

SNC555790 "SIN: 322 represents the serial number for the snubber assembly.

CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and that this Replacement conforms to the rules of the ASME Code,Section XI.

Type Coda Symbol Stamp N/A Certificate of Authorization No.

N/A Expiration Date N/A Signed i~J*/.*1 ,)'V.LJL_***1L... Date .. .! -

- r ....... -i.I.... *';

Owner or Owner's Designee. TItle .. .

CERTIFICATE OF INSER VICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the state or Province of Floidda end employed by HSB Globalm Standards of .Hrfr.C

__________have inspected the components described In this Owner's Report during the period

  • t/o& = '

____to Od<7 2 /z,'r*!" , and state that to the best of my knowledge and belief, the Owner'has performed examinations and taken corrective measures described In this Owner's Report in accordance with the requirements of the ASME Code, Section Xl.

By signing this certificate neither the inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

"*i>'fi* +/-:.2.7l' z*a*.

  • Commissions ,*tI3_*A ,*,1.'-"

Inspector's Signature o National Board, State, Province and Endorsements Page 2 of 2

FORM NiS-2 OWNER'S REPORT FOR REPAIRIREPLACEMENT ACTIVITY As Required By The Provisions Of The ASME Code Section Xl

1. Owner Southern Nuclear OneratinaqCompany Date: 4/28/2015

© Name 40 Inverness CtrPkwy, Birmingqham. AL 35242 Sheet I__________of 2 Address Unit FNPUnit 1 woe SNC 556283

2. Plant Joseph M. FarleyNuclearPlant (FNP) Repair/Replacement Organization P.O. No., Job No., etc.

Name 7388 NV. state Hwy 95. Columbia. Al. 36319 Type Code Symbol Stamp N/A Address Authorization No.

3. Work Performed By N/A FNP Ma~intenanceDepartme~nt Expiration Date N/A Name 7388 NI.State Hwy 95. Columbia, Al. 36319 Address
4. Identification of System E21. Chemical Volume Control System. QIE21SNUBBSS54133B. Class2
5. (a)Applicable Construction Code AISC - 1969 Edition, N/A Addenda, . N/A Code Case (b ) Applicable Edition of Section Xl Used for Repair/Replacement Activlty 2001 EdRton. 2003 Addenda (c) Applicable Section Xl Code Case(s) N/A
6. Identification of Components ________________ ______________ _______

National ASME Code Name of Name of Manufacturer Board Year Corrected, Removed, Stamped (Yes or Component Manufacturer Serial No. No. Other Identification Built or installed No)

Hydraulic lisega 61287/60 N/A QP9S-0277 1993 Removed No Snubber

© Hydraulic Snubber

'Llsega 31400822/030 "N/A SNA10096059 2014 Installed "No

7. Description of Work Replaced snubber as a scheduled upgrade
8. Test Conducted: Hydrostatic Other []

I] Pneumatic []

Pressure _______psi Nominal Operating Pressure Test Temp. _____F___

0] Exempt []

)

FORM NIS-2 (Back)

9. Remarks Certificate of Conformance. VT-3 Examinantion Applicable Manufacturer's Data Reports to be attached C* ~we#sNvc5s83 CERTIFICATE OF COMPLIANCE We certify that the statements made In the report are correct and that this replacement conforms to the rules of the ASME Code, Section Xl. repair or replacement Type Code Symbol Stamp N/A Certifica*torzat/i*$N* N/A Expiration Date N/A Signed ,(IiM 3(,s / 1 Sci JcC Date /- /

Owner or Owner's Designee* "

CERTIFICATE OF INSER VICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the state or Province of Florida and employed by HSB Global.Standards of Hartford. CT have inspected the components described in this Owner's Report during the period . ,/3,*/7.o I

  • to 0 '/I14L / z.-l, - , and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section Xl.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer SHALL be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this K> inspection.

i2 1 ,4*, SZ7o*I$*A Commisions )*---,b*,A--, 44.-*--"

"Inspector's S;ignatur*' National Board, State, Province and Endorsements

.,oje Page 2 of 2

FORM NIS-2 OWNER'S REPORT FOR REPAIR/REPLACEMENT ACTIVITY As Required By The Provisions Of The ASME Code Section XI

1. Owner .Southern Nuclear Operating Company Date: 5/9/2015 Name Sheet  ! of2 40 Inverness C~tr Pkwv. Birmingham,AeL.35242 Unit FNP Unit 1 Address Joseph M. FarleyNuclear Plant (FNP) WO# SNC SN.C566968
2. Plant Repair/Replacement Organization P.O. No., Job No., etc.

Name 7388 N. StateHwy 95. Columbia, Al. 36319 Type Code Symbol Stamp N/A Address Authorization No.

3. Work Performed By N/A Expiration Date N/A FNP Maitentqance Deaartmentt Name 7388 N. State Hwy 95. Columbia, Al. 36319 Address
4. Identification of System Nl, MAIN STEAM SY.STEM. QIN11IVOO3F. C~lass 2
5. (a) Applicable Construction Code 1971 Edition, Summer 1971 Addenda, N/A Code Case (b) Applicable Edition of Section XI Used for Repair/Replacement Activity 2001 Edition. 2003 Addenda .

(c) Applicable Section XI Code Case(s) N/A

6. Iden~tificatIon of Components ____ __________ ___

National ASME Code Name of Name of Manufacturer Board Year Corrected, Removed, Stamped (Yes or Component. Manufacturer Serial No. No. Other Identification Built or Installed No)

Valve Velan 4939 N/A FNP2-21 1976 Removed No Bonnet Valve Velan 17886 N/A QP090475 2009 Installed No Bonnet

7. Description of Work Replaced valve bonnet. .
8. Test Conducted: Hydrostatic [] Pneumatic Q] Nominal Operating Pressure [] Exempt Q]

Other 0] Pressure _______psi Test Temp. _________F

FORM NIS-2 (Back)

9. Remarks N-2 Data Report Applicable Manufacturer's Data Reports to be attached wo# sNC566968 CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and that this reolacement conforms to the rules of the ASME Code, Section Xl. repair or replacement Type Code Symbol Stamp IWNA Certificate of Authorization19 N/A Expiration Date N/A Signed.*f,*i* k,/,, . ,i*,. Io,-*ue Date __*,i.V)/ *],

Owner or Owner's Designee

' ~CERTIFICAT*E OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the state or Province of Florida end employed by lIHSB GlobalStandards of< . Hartford.CT ,

have inspected thte components described in this Owner's Report during the period .,o4/z *-B *<-

to o (.,/o

  • o .',,- and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described In this Owner's Report in accordance with the requirements of the ASME Code, Section Xl.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or Implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the inspector nor his employer SHALL be liable in any manner for any personal injury or property damage or a loss ot any kind arising from or connected with this inspection.

Inspector's signature* National Board, State, Province and Endorsements

FORM NIS-2 OWNER'S REPORT FOR REPAIR/REPLACEMENT ACTIVITY As Required By The Provisions Of The ASME Code Section Xl

1. Owner Southern Nuclear Operating Company Date 06/22/2015

_Name 40 Inverness Ctr Pkwy, Birmingham, AL, 35242 Sheet Iof2 Address

2. "Plant Joseph M. FarleyNuclear Plant (FNP) Unit FNP UNIT 1 Name 7388 N. State Hwy 95, Columbia, AL 36319 WO#: SNC580719 Address Repeir/Replacement Organization P.O. No., Job No., etc.
3. Work Performed by Williams PowerServices Type Code Symbol N/A Stamp _______________

Name Authorization N/A No.__________________ _

7388 N. State Hwy. 95, Columbia, AL. 36319 Expiration N/A Date _________________________

Address

4. Identification of System 01G31VO33A & Q1G31 VO33B Code Class 2
5. (a) Applicable Construction Code Section III 1971 Edition, Summer 1972 Addenda, NA Code Case (b) Applicable Edition of Section Xl Used for Repair/Replacement Activity 2001 Edition 2003 Addenda (c) Applicable Section Xl Code Case(s) NA
6. Identification Of Components National Corrected, ASME Code Name of Name of Manufacturer Board Other Year Removed, or Stamped Component Manufacturer Serial No. No. Identification Built Installed (Yes or No)

VALVE VALVE, 2" TECHNOLOGIES 14105160 NA SNA 10076655 2014 INSTALLED YES VALVE VALVE. 2" TECHNOLOGIES 14105181 NA SNA 10076655 2014 INSTALLED YES SAND VIK PIPE, 2" MATERIALS HT#519775 NA OP090652 2007 INSTALLED NO TECHNOLOGY BIRMINGHAM RESTRA/NT, 2" STEEL CORP. HT#517637 NA QP2306 1988 INSTALLED NO ALLOY STAINLESS ELBOW, 2" PRODUCTS, INC. HT#207150 NA OP 110443 1999 INSTALLED NO KLOECKNER CLAMP, 2" METALS HT# 3506117 NA SNA31372.0192 2014 INSTALLED NO ELBOW, 2" BONNEY FORGE 44027 NA OPl110330 2010 INSTALLED NO COUPLING, 2" BONNEY FORGE 7543 NA 0P090 180 2006 INSTALLED NO ANGLE NORTHWESTERN 4X4X1/4 STEEL & WIRE HT# 83367 NA OP0 70696 2007 INSTALLED NO TUBE STEEL ENERGY 3X3X1/4 PROCESS CORP HT# B313100 NA SNA31372-0 192 2013 INSTALLED NO NORTHWESTERN PLATE A" A36 STEEL &5WIRE HT# B2X9207 NA SNA31607-0002 2013 INSTALLED NO CONSOLIDATED PLATE 14"A36 PIPE&5SUPPLY HT# B1IR6532 NA SNA 10017456 2011 INSTALLED NO Page 1 of 2

7. Description of Work Valve Replacement per DCP SNC524957 WO# SNC580719
8. Test Conducted: Hydrostatic [] Pneumaticr- Nominal Operating PressureiX'i Exemptr-J Other [] Pressure _____psi Test Temp. ____F___

FORM NIS-2 (Rack)

9. Remarks NPV-1 FORM, Certificate of Compliance, CMTRs, VT-2 Examination, DCP524957, WO# SNC58071 9 Applicable Manufacturer's Data Reports to be attached CERTIFICATE OF COMPLIANCE We certify that the statements made in the report ear correct and that this replacement conforms to the rules of the ASME Code, Section Xl. repair or replacement Type Code Symbol N/A Stamp Certificate of NAA Expiration Date N/A Authorization No.

A/

Signed Chris Thornell Date

'4f Owlier rOwe' Designee, Titl'e" ..

CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the state or Province of Florida and employed by HSB Global Standards of Hartford, CT have inspected the components described in this Owner's Report during the period I / /~ ,

to___ a72/.*g nd state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section Xl.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any pers~nu~ or property damage or a loss of any kind arising from or connected with this inspection.

  • P-ff *,**,** .* *Commissions l2,*j~3AitiJc F'-.44.*5-.

Inspector's Signetu'* National Board, 'State, Province and Endorsements DateOl/,zl" Page 2 of 2

FORM NIS-2 OWNER'S REPORT FOR REPAIR/REPLACEMENT ACTIVITY As Required By The Provisions Of The ASME Code Section Xi 1.Owner Southern Nuclear OperatingCompany Date 02/04/2015 Name 40 Inverness Ctr Pkwy,..Birmingham, AL, 35242 Sheet 1 of 2 Address

2. Plant Joseph M. Farley Nuclear Plant (FNP) Unit FNP UNIT 1 Name 7388 N. State Hwy 95, Columbia, AL 36319 DCP SNO 467134, wO# SNC595300 Address Repair/Replacement Organization P.O, No., Job No., etc.
3. Work Performed by FNP Maintenance Department N/A Type Code Symbol (WILLIAM 4S) ~ Stamp Name Authorization N/A No.

Expiration N/A 7388 NV.State Hwy. 95, Columbia, AL. 36319 Date Address

4. Identification of System N23, AUXILIARY FEED WATER SYSTEM, AFW-A1 1, CLASS 3
5. (a) Applicable Construction Code AlSO 1969 Edition, N/A Addenda, N/A Code Case (b) Applicable Edition of Section XI Used for Repair/Replacement Activity 2001 EDITION, 2003 ADDENDA (c) Applicable Section XI Code Case(s) NIA
6. Identification Of Components National Corrected, ASME Code Name of Name of Manufacturer Board Other Year Removed, or Stamped Corn, onent, Manufacturer Serial No. No. Identification Built installed IYes or No) 3/8"X7" NOVA MACHINE N/A NA SNA36051-0101 2015 INSTALLED NO ROLLED PRODUCTS HT#4504999 PLATE (SADDLE) _____ .______ .________

3 1/2" PIPE 'U.S. STEEL N/A NqA SNA33232*-0336 '2014 IN'STALLED NO

___________HT#HA0921 _____

Yh"PLATE SABEL STEEL N/A N/A SNA10088779 2014 INSTALLED NO SCM.CGDP-1 26 HT# 238019 TUBE STEEL SOUTHLAND N/A N/A QP100442 2008 INSTALLED NO 5"X5"X5116" TUBE HT# A46150 3/4A" PLATE NUCOR . .. N/A N/A SNA317I0-0087 2014 INSTALLED NO SCM-CGDP-126

__________ _______________________HT# 2R706 _____ _______ _____

7. Description of Work SUPPORT MODIFIED per DCP 467134 AND we# 595300, AFW-A1 1
8. Test Conducted: Other fl Hydrostatic j[] PneumatioL-'

Pressure _____psi NominalTest Operating Temp. Pressureli Exempt[*]

F__o Page 1 of 2

FORM NIS-2 (Back)

9. Remarks SUPPORT MODIFIED per DCP 467134 AND WO# 595300, SS1 10902, SCM-CGDP-126, SAM FLEX PROJECT Applicable Manufacturer's Data Reports to be attached VT3 EXAMINATION PERFORMED CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and that this NEW conforms to the rules of the ASME Code, Section Xl.

Type Code Symbol N/A Stamp Certificate of N/A Expiration Date N/A Authorization No. __________________________________________

Signd ~Kenneth *W. Baity Signd ,'*#./yz;*{

  • ,.* J'i* -Jr.*'**fl t/a~n,/*Date 41&/15"-,

Owner or Oiner's Designe*, TItle -

CERTIFICATE OF INSER VICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the state or Province of Floridaz and employed by HS;B Global Stazndards; of arfd.C

.have inspected the components described in this Owner's Report during the period .. \ /z,II Z * -

to.__ oh/*/.o ",and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code,Section XI.

By signing this certificate naither the inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Ins;pector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

Inspector's Signature National Board, State, Province and Endorsements Date Oc O-7_O 5 Page 2 of 2

FORM NIS-2 OWNERAS REPORT FOR REPAIRIREPLACEMENT ACTIVITY As Required By The Provisions 01mTh ASME Code Section Xl

1. Owner Southern Nuclear Operating Company Date 7/29/2015 40 Inverness CirFiery, Birmingham, AL. 35242 Sheet 1of 2 Addreos
2. Plant Joseph M. Farley Nuclear Plant (FNP) Unit FNP UNIT 1 Name 7388 N. Slate Hwy 95. Columbla, AL 36310 WO#t: SNC 595307 Address RepalrlReplacsment Organization P.O. No., Job No., etc.
3. Work Performed by FNP Maintenanc'e Deparfn lent Type Code Symboi N/A Stamp ____________

Name Authorization N/A No. _________________

7368 N. State Hwy. 95, Columbia, AlL.36319 Expiration N/A Date Address

4. Identification of System P17, COMPONENT COOLING WATER, 01P17V0149B, CLASS 3 U. (a) Applicable Construction Cede 1971 Edition, WINTER 1971 Addenda, N/A Code Case (it) Applicable Edition of Section Xi Used for RepalrlReplacoment Activity 2001 ED. 20)03 ADD (c) Applicable Section Xl Cede OCae(s) . WA.
6. IdentffIcation Of Components SNational Corrected, ASME Cede Name of Name of Manufacturer Board Other Year Removed, or Stamped component Manufacturer Serial No. No. Identlficatlon . Sulit installed (Yes or No) rx"I1
  • J.E. LONERGAN G59"20 N/A PO: FNP-296 1872 REMOVED NO RELIEF VALVE CO.

DISC 1"X I M" ANCHOR/DARLINGI N/A N/A HT: 82.4706 1990 INSTALLED 'NO RELIEF VALVE VALVE CO. P0: QP-4323 DISC

7. Description of Work REPLACE VALVE DISC DUE TO LEAK.BY8
8. Teat Conducted:

Other Q Q

.ydrostaIc Pressure Pneuatm,____psi Q NominlTestOperting Temp. P"ressr[iE]

___ F__ mt Page 1 of 2

FORM HI'1-2 (Back)

CERTIFICATE OF COMPLIANCEA VT-2 EXAM*INATION, NV-I FORM, Applicable Manufacturer's Data Reports to be attached 9.NC59ark7 Sf40595307 CERTIFICATE OF COMPUANCE We certify that the statements made in the report are correct and that this REPLACEMENT c'onforms to the rules of the ASME Code, Section Xl.

Type Code Symbol Stamp N/A Cartiticata of Authorization N/A No.

Expiraton Date N/A Signed

~ar:*) i$aA I

Oats I I

Ow~flr ol' OvdtdraS Doslgnee,'i'tle I II CERTIFICATE OF INSERViCE INSPECTION I, the underslgned, holding a valid commission issued by the National Beard of Boller and Pressure Vemssel Inspectors and the stats or Province of .Florida and employed by 15B Global Standards of He~r.C have Inspected the components described in this Owner's Report during the period o**3/**

to___,___*'- mad state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described In Ihis Owner's Report in accordance with the requirements of the ASMS Code, Section Xl.

By signing this certificate neither the Inspector nor hie employer makes any warranty, expressed or Implied, concerlnin the examinations and corrective measures described In this Owner's Report. Furthermore, neither the Inspector nor his employer shail be liable In any manner for any personal Injury or property damage or a loss of any kind arising from or connacted with this inspection.

inspactor's Slgnatur6' National Beard, Stats, Province end Endorsements Date b'7 1 t¶ ZOJb Page 2 of 2

FORM NIS-2 OWNER'S REPORT FOR REPAIR/REPLACEMENT ACTIVITY As Required By The Provisions Of The ASME Code Section XI 1.Owner Southern Nuclear Operating Company Date 6/8/2015 Name 40 Inverness Ctr Pkwy, Birmingham, AL. 35242 Sheet 1 of 2 Address

2. Plant Joseph M. Farley Nuclear Plant (FNP) Unit FNPUNIT 1 Name 7388 N. State Hwy 95, Columbia, AL 36319 WO#: 8NC595865 Address RepairlReplacement Organization P.O. No., Job No., etc.
3. Work Performed by FNP Maintenance Department Type Code Symbol N/A

-Stamp__ _ _ _ _ _ _ _ _ _ _ _ _

Name Authorization N/A No.__________________ _

7388 N. State Hwy. 95, Columbia, AL 363319 Expiration N/A Date _______________________

Address

4. Identification of System N23, Auxiliary Feedwater System, QIN23P0OIA, Class 3
5. (a) Applicable Construction Code ASME Sect. III 1971 Edition, Summer 1971 Addenda, N/A Code Case (b) Applicable Edition of Section XI Used for Repair/Replacement Activity 2001 ED 12003 Add.

(c) Applicable Section Xl Code Case(s) .. N/A....

6. Identification Of Components National Corrected, ASME Code Name of Name of Manufacturer Board Other Year Removed, or Stamped Component Manufacturer Serial No. No. Identification Built Installed (Yes or No) 1 W' SCHED. UNITED STATES N/A N/A HT: 2P4572 1976 REMOVED NO 80 PIPE STEEL CORP. P0: FNP2-35___________

S141/4" UNION (2) ALLOY STAINLESS N/A N/A HT: 09802, 65736. 1976 REMOVED NO

. 30121

____________ P0: FNP2-35 ____

I1 4" 90 DEG. LADISH CO N/A N/A HT: 45880 1976 REMOVED NO ELBOWS (2) ____________ P0: FNP2-35 ________________

I 4"SCHED. WALSIN N/A N/A HT." 3X902 2014 INSTALLED NO 80 PIPE _______P0: SNA31372-0208 ____ ______

I141/4" UNION BONNEY FORGE N/A N/A HT: MALE: 7518, NUT: 2014 INSTALLED NO 7549, FEMALE: 7520

_____________ ____________Pfl. .gNA.nqp*.n~q _,._______,____,__

1 W"'90 DEG. CAMCO N/A N/A HT: EH 2014 INSTALLED NO ELBOWS (2) P0: SNA31710-0109

7. Description of Work Pipe and fittings replacedas part of a Minor Design Change Package.
8. Test Conducted:

Other 5] fl PneumaticS]

Hydrostatic Pressure _____psi NominalTestOperating Temp. Pressure j] F Exempt[LI Page 1 of 2

FORM NIS-2 (Back)

Statement of Conformance, N-2 Form, VT-2 Examination. MDC: SNC558042

9. NCemark5 - Applicable Manufacturer's Data Reports to be attached SNC595865 V

CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and that this Replacement conforms to the rules of the ASME Code, Section Xl.

Type Code Symbol Stamp N/A Certificate of Authorization No. N/A Expiration Date N/A Owner or Owner's Designee, Title CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the state or Province of Florida and employed by HSB Global Standar~ds of Hartord, CT hlave inspected the components described in this Owner's Report during the period a*," _* -

_____to O", oZoS and state that to the best of my kcnowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section Xh.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

Inspector's Signature *JNational Board, State, Province and Endorsements Date 0lI.o*05-Page 2 of 2

FORM NIS-2 OWNER'S REPORT FOR REPAIRIREPLACEMENT ACTIVITY As Required By The Provisions Of The ASME Code Section Xl

1. Owner Southern Nuclear OperatinglCompany Date 6/8/2015 Name 40 Inverness C~tr Pkwy, Birmingham, AL. 35242 Sheet 1of 2 Address
2. Plant Joseph M. Farley Nuclear Plant (FNP) Unit FNP UNIT 1 Name 7388 N. State Hwy 95, Columbia, AL 36319 WO#: SNC595867 Address Repair/Replacement Organization P.O. No., Job No., etc.
3. Work Performed by FNP Maintenance Department Type Code Symbol Stamp N/A Name Authorization N/A No.

7388 N. State Hwy. 95, Columbia, AL. 36319 Expiration N/A Date Address

4. Identification of System N23, Auxiliary FeedwaterSystem, QIN23POOIB, Class 3
5. (a) Applicable Construction Code ASME Sect. III 1971 Edition, Summer 1971 Addenda, N/A Code Case (b) Applicable Edition of Section Xl Used for Repair/Replacement Activity 2001 ED /2003 Add.

(c) Applicable Section Xl Code Case(s) N/A

6. Identification Of Components National Corrected, ASME Cede Name of Name of Manufacturer Board Other Year Removed, or Stamped Component Manufacturer Serial No. No. Identification Built Installed (Yes, or No) 1 34" SCHED. ALLEGHENY N/A N/A HT: 2P4572 1976 REMOVED NO 80 PIPE LLUDLUM STEEL P0: FNP2-35 _______________

1 W" UNION (2) ALLOY STAINLESS N/A N/A HT." 09802 1976 REMOVED NO

_________ _____________________P0: FNP235 __________

I 34" 90 DEG. LADISH CO N/A N/A HT: 45880 1976 REMOVED NO ELBOWS (2) ______ ____ P0: FNP2-35_____

L_1W"SCHED. SCHOELLER N/A N/A HT: 035459 2014 INSTALLED NO 80 PIPE BLECKMAN P0: SNAB1372-0144 ____

1 34"UNION STAINLESS N/A N/A HT." NUT:"19416, 1985 INSTALLED NO PRODUCTS BODY:85549

___________pfl_, Qpnn* ________________

1 W"UNION CAMCO N/A N/A HT: MALE: FBI, 1985 INSTALLED NO FEMALE: FCE, NUT:"IP

_______________P____~n" .nn~s ____________ _____

1 34"90 DEG. ALLOY STAINLESS N/A N/A HT: ZL 1973 INSTALLED NO ELBOWS (2) P0: 7047-Q-61585

7. Description of Work Pipe and fittings rep/aced as part of a Minor Design Change Package.
8. Test conducted: Hydrostatic Other [] fl PneumaticE'-

Pressure Nominal psi Test

.____ Operating Temp. Prassurer*

_______ F ExemptrE Page 1 of 2

FORM NIS-2 (Back)

Statement of Conformance, N-2 Form, VT-2 Examination. MDC: SNC558042 NRema8k7 Applicable Manufacturer's Data Reports to be attached 9.

SNC595867 CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and that this Replacement conforms to the rules of the ASME Code, Section Xl.

Type Code Symbol Stamp N/A Certificate of Authorization No.ExrainDtNA N/A Expiration Date N/A Signed _^l,.ll.v.*:/l_'_. /c*/*

  • Date 6 -*_*-I E Owner or Owner's Designee, Title CERTiFICATE OF INSER VICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the state or Province of Florida and employed by HSB Global Standards of Hartfrd, CT have inspected the components described in this Owner's Report during the period toz!1/- -"

to___ O7"-*zJ",and state that to the best of my knowledge end belief, the Owner has performed exmiations and taken corrective measures described In this Owner's Report in accordance with the requirements of the ASME Code, Section Xl.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations end corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this Inspection.

lnspctor~gntureJ Board, State, Province and Endorsements

-National Datetr' SgatreL Page 2 of 2

FORM NIS-2 OWNER'S REPORT FOR REPAIR/REPLACEMENT ACTIVITY As Required By The Provisions Of The ASME Code Section Xl

1. Owner Southern Nuclear Operating Company Date 03/26/15 Name 40 Inverness Ctr Pkwy, Birmingham, AL, 35242 Sheet 1 of 2 Address
2. Plant Joseph M. Farley Nuclear Plant(FNP) Unit FNP UNIT 1
  • Name 7388 N. State Hwy 95, Columbia, AL 36319 DCP SNO 467136. WO#: SNC 599493 Address RepairlReplacement Organization P.O. No., Job No., etc.
3. Work Performed by FNP Maintenance Department Type Code Symbol N/A Stamp Name Authorization N/A No.

7388 N. Slate Hwy. 95, Columbia, AL. 36319 Expiration N/A Date Address

4. Identification of System E21, HHS1/CVCS SYSTEM, SS-1065 , CLASS 2
5. (a) Applicable Construction Code AISC 1969 Edition, N'A Addenda, N/A Code Case (b) Applicable Edition of Section XI Used for Repair/Replacement Activity 2001 EDITION, 2003 ADDENDA (c) Applicable Section Xl Code Case(s) N/A
6. Identification Of Components National Corrected, ASME Code Name of Name of Manufacturer Board Other Year Removed, or Stamped Component Manufacturer Serial No. No. Identification Built Installed (Yes or No) 1/2k"PLATE CARGILL INC. N/A N/A SNA1 0088779 2014 INSTALLED NO SCM-CGDP-i126 HT #238019 ANCHOR, 2" ANVIL N/A N/A SNA1 0099424 2011 INqSTALLED NO PIPE P/N 1297328
7. Description of Work SUPPORT MODIFIED PER WO SNC599493, DCP SNC4671 36, SS-1065
8. Test Conducted:

Other 5] fl Hydrostatic PneumaticE--

Pressure _____psi NominalTest Operating Pressurer-'

Temp. ______ 0 F

Exempt[*

Page 1 of 2

FOAM NIS-2 (Back)

9. Remarks SUPPORT MODIFIED PER* DCP 467136 AND we # SNC599493, SSl10g02, DEDICATION PLAN :SCM-CGDP-126 Applicable Manufacturer's Data Reports to be attached VT3 EXAMINATION PERFORMED

( CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and that this NEW conforms to the rules of the ASME Code, Section Xl, Type Code Symbol N/A Stamp Certificate of N/A Authorization No.

Expiration Date N/A Signed Kejineth W. Baitv Date

- Owner or O~6ner's Designi"e, Title "

CERTIFICATE OF INSER VICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the state or Province of Flordda and employed by . HSB Global Standards; of .Hrtord, CT "

. have inspected the components described in this Owner's Report during the period I ./q-~*

to___ /o' .:,'-,and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section Xl.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a lees of any kind arising from or connected with this inspection.

Commissions 1 .1, Al~..,**' '

  • -- Inspector's Signature*'9 National Board, State, Province and Endorsements DateO Page 2 of 2

FORM NIS-2 OWNER'S REPORT FOR REPAIR/REPLACEMENT ACTIVITY As Required By The Provisions Of The ASME Code Section XI

1. Owner Southern Nuclear OperatingCompany Date 02/04/2015 Name 40 Inverness Ctr Pkwy, Birmingham, AL, 35242 Sheet 1 ot 2 Address
2. Plant Joseph M. Farley Nuclear Plant (FNP) Unit FNP UNiT 1 Name 7388 N. State Hwy 95, Columbia, AL 36319 DCP SNC 467142, WON: SNC 601311 Address Repair/Replacement Organization P.O. No., Job No., etc.
3. Work Performed by FNP Maintenance Department Type Code Symbol N/A Stamp ______________

Name Authorization N/A No.__ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

7388 N. State Hwy. 95, Columbia, AL. 36319 Expiration N/A Date _________________________

Address

4. identification of System I U1 SFP COOLING, SCS-H762, CLASS 3
5. (a) Applicable Construction Code AISO 1969 Edition, N/A Addenda, Code Case (b) Applicable Edition of Section Xl Used for RepairlReplacement Activity 2001 EDITION, 2003 ADDENDA (c) Applicable Section XI Code Case(s) N/....iA......
6. Identification Of Components National Corrected, ASME Code Name of Name ot Manufacturer Board Other Year Removed, or Stamped Component Manufacturer Serial No. No. Identification Built installed *Yes or No) 1/" PLATE CARGILL INC. N/A NIA 8NA10088779 2014 INSTALLED NO

_____________ HT# 238019 _____

3/4A" PLATE EVRAZ INC. N/A N/A SNA31710-0087 2012 INSTALLED NO HT# 2R706 4"X4"X1/4'" SABEL N/A N/A SNA10082837 2014 INSTALLED NO TUBE STEEL HT#J40401 R STRUCTU RE __________ ____

3" PI PE ANVIL EPS N/A N/A SNA10099581 2014 INSTALLED NO STRAP HT# JJ1248

7. Description of Work NEW SUPPORT INSTALLED PER WO SNC601311, DOP SNC467142, SS110902
8. Test Conducted: Hydrostatic Other [] [] Pneumatic[-]

Pressure _____psi NominalTest Operating Temp. Pressure[]

Exempt jX Page 1 of 2

FORM NIS-2 (Back)

9. Remarks SUPPORT # SCS-H762, 3"-HCC-107, DEDICATION PLAN "SCM-CGDP-126 Applicable Manufacturer's Data Reports to be attached VT3 EXAMINATION PERFORMED SNcIOlts 1 CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and that this NEW conforms to the rules of the ASME Code,Section XI.

Type Code Symbol N/A Stamp Certificate of N/A Expiration Date N/A Authorization No. ___________________ _________________

Owner or Owner's Designee, Title *llr *'* C..-) *M* *.

CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the state or Province of Florida and employed by HSB Global Standards of H rtfordl CT have Inspected the components described in this Owner's Report during the period 2.u/-o I*

__ to o*./c=,,/ pol ., end state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section Xl.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

Inspector's SignetS're National Board, State, Province and Endorsements Date O/3h i//.z,*-

Page 2 of 2

FORM NIS-2 OIWNER'S REPORT FOR REPAIRJREPLACEMENT ACTIVITY As Required By The Provisions Of The ASME Code Section Xl

1. Owner Southern Nuclear Operating Company Date 6/15/2015 Name 40 Inverness Ctr Pkwy, Birmingham, AL, 35242 Sheet of 2 Address
2. Plant Joseph M. Fartey Nuclear Plant(FNP) Unit FNP UNIT 1 Name 7388 N. State Hwy 95, Columbia, AL 36319 WO#: SNC602640 Address Repair/Replacement Organization P.O. No., Job No., etc.
3. Work Performed by FNPMaintenance Departmsint Type Code Symbol N/A

_____ Stamp__________ _____

-Name Authorization N/A No.__ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

7388 N. State Hwy. 95, Columbia, AL. 36319 Expiration N/A Date_______________________ _

Address

4. Identification of System E21, Chemical Volume Control Systerm, QIE21POO2B, Class 2 S. (a) Applicable Construction Code ASME Sect. IIl 1971 Edition, Summer 1972 Addenda, N/A Code Case (b) Applicable Edition of Section Xl Used for RepairlReplacement Activity 2001 ED. 2003 ADD.

(c) Applicable Section Xl Code Case(s) ......11A.....

B. Identification Of Components National Corrected, ASME Code Name of Name of Manufacturer Board Other Year Removed, or Stamped Component Manufacturer Serial No. No. Identification Built Installed (Yes or No)

PUMP CASING PACIFICPUMP 46355 N/A P0: FNP.2 1976 REMOVED YES OUTER SEAL FLOWSERVE RLSA01678-5 N/A P0): QP040126 2001 REMOVED NO HOUSING (OUTBOARD) _____ __________

PUMP CASING HYDROAIRE 54 76-0 1 N/A P0: 0P060948 2007 INSTALLED YES SERVICES INC OUTER SEAL FLOWSERVE N/A N/A IHT: 42047 2010 INSTALLED NO HOUSING LOT:" RLSA 16522 (OUTBOARD) _______P0: OP 100782 _ __

?'. Description of Work Replacedpump casingand seal housingper Minor Design Change S. Test Conducted:

f Hydrostatic fl Other I Pressure Pneumatic[-'

_____psi NominalTestOperating Pressurefj]

Temp. _______ F Exempt[]

Page 1 of 2

FORM NIS-2 (Back)

9. Remarks Certificate of Conformance, N-2 Form, VT-2 Examination, MDC: 348823, ED090092701 Rev. 3.0 Applicable Manufacturer's Data Reports to be attached SNC602640 CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and that this Replae~ment conforms to the rules of the ASME Code,Section XI.

Type Code Symbol Stamp Nl/A Certificate of Authorization Expiration Date No.

N/A N/A Signed Date i** *-

- Owner or Owner's Designee, Title CERTIFICATE OF INSER VICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the state or Province of Florida and employed by HSB GLO.BAL STANDARDS of Hartfrd CT have inspected the components described in this Owner's Report during the period ,.p*.(2 '

to__/_____._o*" and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section Xl.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

"* *' ,e *

  • Commissions *zsrF-4 Inspector's Signature' National Board, State, Province and Endorsements Date 0K[-/'.*

Page 2 of 2

FORM NIS-2 OWNER'S REPORT FOR REPAIR/REPLACEMENT ACTIVITY As Required By The Provisions Of The ASME Code Section XI

1. Owner Southern Nuclear Operating Company Date: 5/2/2015 Name Sheet 1 of 2 40 Inverness Ctr-Pkwy. Birmingham, AL. 35242 Unit FNP Unit 1 Address Joseph M. Farley Nuclear Plant (FNPJ WON SNC 633702
2. Plant Repair/Replacement Organization P.O. No., Job No., etc.

Name Type Code Symbol Stamp N/A 7388 N. State Hwy 95. Columbia. Al. 36319 Address Authorization No. N/A

3. Work Performed By Expiration Date N/A Name
  • 7388 N. State Hwy 95. Columbia, Al. 36319 Address
4. Identification of System El1. Residual Heat Removal/Low Head Safety Injection. Q1ElI1SNUBBRHRR93. Class 2
5. (a) Applicable Construction Code A15C-1959 Edition, N/A Addenda, N/A Code Case (b) Applicable Edition of Section XI Used for Repair/Replacement Activity 2001 Edltion. 2003 Addenda (c) Appiicabie Section Xl Code Case(s) N/A
6. identification of Components Nationai ASME Code Name of Name of Manufacturer Board Year Corrected, Removed, Stamped (Yes or Component Manufacturer Serial No. No. Other Identification Built or Installed No)

Hydraulic ITT Grinnell 22037 N/A FNP-222 19.74 Removed No Snubber Hydraulic Anvil 39610 N/A SNA10098417 2014 Installed No Snubber

7. Description of Work Reisfaced snubber as ascheduled uparade per EauivalencvDeterminationC092533401 El El Pressure Pneumatic El El Exempt 0]
8. Test Conducted: Hydrostatic Nominal Operating Pressure Other _______psi Test Temp. F

FORM NIS-2 (Back)

9. Remarks Certificate of Compilance. VT-3 Examination Applicable Manufacturer's Data Reports to be attached woN 5NC 633702 CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and that this replacement conforms to the rules of the ASME Code, Section Xl. repair or replacement Type Code Symbol Stamp N/A Certificate of Authorization No. N/A Expiration Date N/A s It1nedLJ Bate ________

Owner or Owner's Designee CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the state or Province of Florida and employed by HSB Global Standards of a Hartford, CT have inspected the cpmponents described in this Owner's Report during the period ¢ */i/~.o// J**

to *)6/r 271 2--0i,*f and state that to the best of my knowledge and belief, the Owne;r has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section Xl.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer SHALL be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

Commisions \*-., o3.L i C., fL.-44<*

Inspector's Signlatui/' National Board, State, Province end Endorsements Date * '/'-, "

Page 2 of 2

FORM NIS-2 OWNER'S REPORT FOR REPAIRIREPLACEMENT ACTIVITY As Required By The Provisions Of The ASME Code Section Xl

1. Owner Southern Nuclear Operating Company Date 6/8/2015 Name 40 Inverness Ctr Pkwy, Birmingham, AL, 35242 Sheet of 2 Address
2. Plant Joseph M. Farley Nuclear Plant(FNP) Unit FNP UNIT 1 Name 7388 N. State Hwy 95, Columbia, AL 36319 WO#: SNC63 7037 Address Repair/Replacement Organization P.O. No., Job No., etc.
3. Work Performed by FNP MaintenanceDepartment Type Code Symbol N/A Stamp__ _ _ _ _ _ _ _ _ _ _

Name Authorization N/A No.__ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

7388 N. State Hwy. 95, Columbia, AL. 36319 Expiration N/A Date _______________________

Address

4. Identification of System P16. Service Water System, QIP16-HBC-205-2, Class 3
5. (a) Applicable Construction Coda ASME Sect. III 1971 Edition, Summer 1971 Addenda, N/A Code Case (b) Applicable Edition of Section Xl Used for Repair/Replacement Activity 2001 ED/12003 Add.

(c) Applicable Section Xl Code Case(s) NIA

6. Identification Of Components National Corrected, ASME Code Name of Name of Manufacturer Beard Other Year Removed, or Stamped Cornponent Manufacturer Serial No. No. Identificetion Built Installed I~sor Nol 6" PiPE /ITT GRINNELL N/A N/A HT." 24136 1973 REMOVED NO

________ __________P0: FNP-210 ____

6"ELBOW /IT GRINNELL N/A N/A HT: UK3Y 1973 REMOVED NO

_________ ~~~~P0:

FNP-210___________

6" WN FLANGE flT GRINNELL N/A N/A HT: DGU 1973 REMOVED NO

_________P0: FNP-210_____

6" PIPE US STEEL N/A N/A HT: C65182 2013 INSTALLED NO

__________ ___________ P0:. SNA33232-0175 ______ ____

6"ELBOW TFA N/A IN/A HT: XO54B 2013 INSTALLED NO

__________ P0: SNA31372-0034 ____

6" WN FLANIGE COFFER N/A N/A HT: ZMF 2015 INSTALLED NO

___________ _________P0: SNA31372.0332 ____

7. Description of Work Pipe and fittings replaceddue to through walt leak.
8. Test Conducted: Hydrostatic Other [] El PneumaticU--

Pressure _____psi NominalTestOperating Pressurex-il Temp._______

ExemptiZ Page 1 of 2

FORM NIS-2 (Back)

9. Remarks Certificate of Compliance, NPP-1 Form, VT-2 Examination. SSl 109-02 Appendix A Table 30.

Applicable Manufacturer's Data Reports to be attached SNC637037 CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and that this Renlace*ment conforms to the rules of the ASME Code, Section Xl.

Type Code Symbol Stamp N/A SCertificate of Authorization N/A Expiration Date N/A No.

Signed Date 6 /_*--

Owner or Owner's Designee, Title CERTIFICATE O'F INSER VICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the state or Province of Florida and employed by HSB Global Standards of HalarC have inspected the components described in this Owner's Report during the period ,'3/ll/2.o El."

to__,_,_,_/__o" and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section Xl.

By" signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

Inspector's Signature 2, National Board, State, Province and Endorsements Date ]2*J2l" Page 2 of 2

FORM NIS-2 OWNER'S REPORT FOR REPAIRIREPLACEMENT ACTIVITY As Required By The Provisions Of The ASME Code Section Xl

1. Owner Southern Nuclear Operating Company Date 4/2312015 Name 40 Inverness CtrPkwy, Birmingham. AL, 35242 Sheet 1of 2 Address
2. Plant Joseph M. FarleyNuclear Plant (FNP) Unit FNP UNIT 1 Neme 7388 N. State Hwy 95, Columbia, AL 36319 WO#: SNC637465 Address Repair/Replacement Organization P.O. No., Job No., etc.
3. Work Performed by FNPMaintenance Department Type Code Symbol N/A Stamp______________ __

Name Authorization N/A No. _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

7388 N. State Hwy. 95, Columbia, AL. 36319 Expiration N/A Date _______________________

Address

4. Identification of System P16, Service Water System. QIP16VOO5F. Class 3
5. (a) Applicable Construction Code ASME Sect. IIl 1971 Edition, Winter 1971" Addenda, N/A Code case (b) Applicable Edition of Section XI Used for RepairlReplacement Activity 2001 ED 12003 Add.

(c) Applicable Section Xl Code Case(s) .. J1&.A....

6. Identification Of Components National Corrected, ASME Code Name of Name of Manufacturer Board Other Year Removed, or Stamped Component Manuf~acturer Serial No. No. Identification Built Installed (Yes or No) 2" BALL VAL VE BNL INDUSTRIES *126A-2 N/A P0: 0P070775 2008 REMOVED NO BODY ______ ___________________ _____

2" BALL VALVE BNL INDUSTRIES *129A N/A P0: QP070775 2008 REMOVED NO DISK __________________________ _____

2" BALL VALVE BNL INDUSTRIES **126A-1 N/A P0: QP070775 2008 INSTALLED NO BODY _______ _____

2,BALL VALVE BNL INDUSTRIES "*129A-1 N/A P0: QP070775 2008 INSTALLED NO DISK ______ _____ ______________ ____

7. Description of Work Replaced valve body and Disk due to normal wear.
8. Test Conducted: Other 5] 5]

Hydrostatic Pressure Pneumatic[--

______psi Nominal Operating Test Temp. Presaurern]

_______ F Exemptf-l Page 1 of 2

FORM NiS-2 (Back)

9. Remarks NPV-1 Forms, VT-2 Exam, Applicable Manufacturer's Data Reports to be attached SNC637465 *with NB6111.1C of Winter 1972 Add.
    • Parts from Valve SIN: A070809-1 -38, ** Parts from Valve SIN: A070809-1-47 CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct end that this Replacement conforms to the rules of the ASME Code,Section XI.

Type Code Symbol N/A Stamp Certificate of N/A Authorization No.

Expiration Date N/A Signed pr Date OwnerrOwne's DeineTil Owner or Owner's Designee, Title CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the state or Province of Florida and employed by HSB* Global Standa]rds of H rfrd, CT have Inspected the components described In this Owner's Report during the period o /{ *J:

_ -to_______ 7-**' and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section Xl.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

~obt4~ 'I S2~t4 2.*'*,,1**.Commissions

  • 4,'

National Board, State, InspectoIr's Signature Province and Endorsements Date 0f 3gZ'/ol "

Page 2 of 2

FORM NIS-2 OWNER'S REPORT FOR REPAIR/REPLACEMENT ACTIVITY As Required By The Provisions Of The ASME Code Section Xl

1. Owner Southern Nuclear Operating Company Date 8/15/20 15 Name 40 Inverness Ctr Pkwy. Birmingham, AL, 35242 Sheet of2 Address
2. Plant Joseph M. FarleyNuclear Plant (FNP) Unit FNP UNIT 1 Name 7388 N. State Hwy 95, Columbia, AL 36319 WO#: SNC645570 Address Repair/Replacement Organization P.O. No., Job No., etc.
3. Work Performed by FNP MaintenanceDepartment Type Code Symbol N/A Stamp Name Authorization N/A No.

7388 N. State Hwy. 95. Columbia. AL. 36319 Expiration N/A Date Address

4. Identification of System P16, Service Water System, Q1P16F501A, Class 3
5. (a) Applicable Construction Code ASME Sect, III 1971 Edition, Winter 1971 Addenda, N/A Code Case (b) Applicable Edition of Section Xl Used for Repair/Replacement Activity 2001 ED/12003 ADD (c) Applicable Section XI Code Case(s) N/A
6. Identification Of Components National Corrected, ASME Code Name of Name of Manufacturer Board Other Year Removed, or Stamped Cornponent Manufacturer Serial No. No. Identification Built Installed IYes or Nol
  • " STUDS (8) "S.P.KINNEY "5291 '2077 "P0: FNP-309 "1974 REMOVED NO AND NUTS (16) ENGINEERS _____

3/4" STUDS (8) NOVA N/A N/A HT:~10051400 2010 INSTALLED NO

______________________ __________PD:_QP100679 ____

3/4" HEX NUTS DUBOSE N/A N/A HT: 10098130 2013 INSTALLED NO (16) NATIONAL ______P0: SNA31710-0020 _____ ______

7. Description of Work Replaced due to normal wear.
8. Test Conducted:

Other fl jJ Pressure Hydrostatic Pneumaticr'-

_____psi NominalTest Operating Temp. Pressure*]

______ 'F ExemptE*

Page 1 of 2

FORM NIS-2 (Back)

9. Remarks Certificate of Compliance, VT-2 Exam, Piping Applicable Manufacturer's Data SS-1 Specification: 109-02, Reports Appendix to be attachedA Table 30 5NC645570 *Original Studs and Nuts were provided as part of the strainer assembly. S/N: 5291 is for the strainer assembly.

CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and that this Replacement conforms to the rules of the ASME Code,Section XI.

Type Code Symbol Stamp N/A Certificate of Authorization Expiration Date N/A N/A No.

Signed ._.

tl

!hKM~ ,~AS ,v\ Date __I*"

Owner or Owner's Designee, Title CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the state or Province of Florda* and employed by *HSB Global StanIdards of HtfrCT have inspected the components described in this Owner's Report during the period 0*/Lr/il*"Z.

___ o_ O/t/*;," ,and state that to the best of my knowledge end belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section Xl.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

a.., Commissions

  • 2-tlV3,Ai*c, gL.{4-"-

National Board, State, Province and Endorsements Inspector's Signature Cd Date O'/l*O

Page 2 of 2

FORM NIS-2 OWNER'S REPORT FOR REPAIR/REPLACEMENT ACTIVITY As Required By The Provisions Of The ASME Code Section Xl

1. Owner Southern Nuclear OperatingCompany Date 6/8/2015 Name 40 Inverness Ctr Pkwy, Birmingham, AL. 35242 Sheet 1of 2

Address

2. Plant Joseph M. Fartey Nuclear Plant(FNP) Unit _FNP UNIT 1 Name 7388 N. State Hwy 95, Columbia, AL 36319 WO#: SNC645669 Address RepairlReplacement Organization P.O. No., Job No., etc.
3. Work Performed by FNP Maintenance Department Type Code Symbol N/A Stamp__ _ _ _ _ _ _ _ _ _ _

Name Authorization N/A No.__ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

7388 N. State Hwy. 95, Columbia, AL. 36319 Expiration N/A Date________________________ _

Address

4. Identification of System P16, Service Water System, QIP16-HBC-205-4, Class 3
5. (a) Applicable Construction Code ASME Sect. III 1971 Edition, Summer 1971 Addenda, N/A Code Case (b) Applicable Edition of Section XI Used for RepaidrReplecement Activity 2001 ED 12003 Add.

(c) Applicable Section Xl Code Case(s) 1A......

6. Identification Of Components National Corrected, ASME Code Name of Name of Manufacturer Board Other Year Removed, or Stamped Component Manufacturer Serial No. No. Identification Built Installed (Yes or No) 6" PIPE 1TT GRINNELL N/A N/A HT:~26504 1973 REMOVED NO

___________ ~~~P0: FNP-210___________

6"ELBOW ITT GRINNELL N/A N/A HT: UG3X 1973 REMOVED NO

_________ ___________P0: FNP-210_____

6" WN FLANGE lITT GRINNELL N/A N/A HT: DFE 1973 REMOVED NO

_________ ____________ ~~~P0: FNP-210 _______________

6" PIPE US STEEL N/A N/A HT: C65182 2013 INSTALLED NO

__________ _________P0: SNA33232-0175 6" ELBOW TFA N/A N/A H-T: N044FR 2003 INSTALLED NO

___________ _________P0: OP030772____

6" WN FLANGE COFFER N./A N/A HT:' ZMF 2015 INSTALLED NO

______________________P0: SNA31372-0332 ____

7. Description of Work Pipe and fittings replaceddue to through wall leak.
8. Test Conducted: Hydrostatic Other [] 5] Pneumatic[--

Pressure _____psi NominalTestOperating Temp. Pressure*]1 Exempt5[

Page 1 of 2

FORM NIS-2 (Back)

Certificate of Compliance, NPP-1 Form, VT-2 Examination. SS1 109-02 Appendix A Table 30.

NRemar6s Applicable Manufacturer's Data Reports to be attached 9.

5NC645669 CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and that this Replacement conforms to the rules of the ASME Code, Section Xl.

Type Code Symbol Stamp N/A Certificate of Authorization N/A Expiration Date No. N/A Signed *~~AJc (cL VA). 1/LO..4A~

~Ms ~ Date -,,-/

~Th~nr Wig lyre Vm Owner's Designee, Title CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the state or Province of Florida and employed by HSB GloblfStndarsroford CT

.he~ve inspected the components described in this Owner's Report during the period */*/*-, -

_____ to 0 _"72-D15 , and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section Xl.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

I....:nspector's Signature "U National Board, State, Province and Endorsements Date *2'/.O "

Page 2 of 2

FORM NIS-2 OWNER'S REPORT FOR REPAIR/REPLACEMENT ACTIVITY As Required By The Provisions Of The ASME Code Section XI

1. Owner Southern NuclearOperating Company Date 5/28/2015 Name 40 Inverness C~t Pkwy, Birmingham, AL, 35242 Sheet of 2 Address
2. Plant Joseph M. Farley Nuclear Plant (FNP) Unit FNP UNIT 1 Name 7388 N. State H-wy 95, Columbia, AL 36319 WO#: SNC64 7950 Address Repair/Replacement Organization P.O. No., Job No., etc.
3. Work Performed by FNP Maintenance Department Type Code Symbol N/A Stamp ________________

Name Authorization N/A No.__ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

7388 N. State Hwy. 95, Columbia, AL. 36319 Expiration N/A Date _________________________

Address 4.

P16, Service Water System, 0IP16V560. Class 3 Identification of System

5. (a) Applicable Construction Code ASME Sect. III 1971 Edition, Summer 1972 Addenda, N/A Code Case (b) Applicable Edition of Section Xl Used for Repair/Replacement Activity 2001 ED 12003 Add.

(c) Applicable Section Xl Code Case(s) N/

6. Identification Of Components National Corrected, ASME Code Name of Name of Manufacturer Board Other Year Removed, or Stamped Component Manufacturer Serial No. No. Identification Built Installed (Yes or No) 20" HAMMEL-DAHL 72-8475/050 N/A P0: FNP-269 1976 REMOVED YES BUTTERFLY VAL VE 1 -1/8" STUD UNK UNK N/A UNK UNK REMOVED NO (20) __________________ ___________

1-1I/8" NUTS UNVK UNK N/A UNK UNK REMOVED NO (40) _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

S20" FISHER BH3823.1 7558 P0: QP080054 2008 INSTALLED YES BUTTERFLY VALVE __________________ ___ __

1 -1/8"STUD NOVA N/A N/A HT: 59412 2007 INSTALLED NO (10) _______ _____ P0: QP070180 _____ _______ _____

I -1/8" STUD T&T N/A N/A HT: DL 12106944 2014 INSTALLED NO (30) ENTERPRISES _ ________ P0: SNA 10102625_____

1-I/8" NUTS MACKSON N/A N/A HT: M822391 2001 INSTALLED NO (40) ______ P0: SNA 10102625 ___ ______ _____

7. Description of Work Replaced butterfly valve and bolting for DCP.
8. Test Conducted:

Other LI Hydrostatic Pressure

[J Pneumaticr"

______psi NominalTest Operating Temp. Pressurer']

____ F__Exempt[-]

Page 1 of 2

FORM NIS-2 (Back)

9. Remarks NPV-1 Forms, VT-2 Exam, Certificate of Comiliance. DCP SNC647902 Applicable Manufacturer's Data Reports to be attached SNC647950 CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and that this Replacement conforms to the rules of the ASME Code, Section Xl.

Type Code Symbol N/A Stamp Certificate of N/A Expiration Date N/A Authorization No.

Kenneth W. Baity Signed K* .f.

  • 5t4e ,O*[*x hln~- Date (,,IS/IS

/Owner or Ownl~r's Desigt¶ee, Title CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission Issued by the National Board of Boiler and Pressure Vessel Inspectors and the state or Province of Flodida and employed by HSB Global Standards of Hrfd1CT have inspected the components described in this Owner's Report during the period **2***!*

_ __t_____ /2* *. and state that to the best of my knowledge and belief, the Owner has performedl examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section Xl.

By signing this certificate neither the inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

Inspector'*"Signature Province and Endorsements Date O(o O~ 2-ol~

Page 2 of 2

FORM NIS-2 OWNER'S REPORT FOR REPAIRIREPLACEMENT ACTIVITY As Required By The Provisions Of The ASME Code Section Xl

1. Owner Southern Nuclear Operatinq Company Date 6/8/2015 Name 40 Inverness Ctr Pkwy, Birmingham, AL, 35242 Sheet 1of 2 Address 2.Plant Joseph M. Farley NuclearPlant (FNP) Unit FNP UNIT 1 Name 7388 N. State Hwy 95, Columbia, AL 36319 WO#: SNC651 188 Address RepairlReplacement Organization P.O. No., Job No., etc.
3. Work Performed by FNP MaintenanceDepartment Type Code Symbol Stamp N/A Name Authorization N/A No.

7388 N. State Hwy. 95, Columbia, AL. 36319 Expiration N/A Date Address

4. Identification of System 813, Reactor Coolant System, 018B13SNUBBRCR37, Class 1
5. (a) Applicable Construction Code AISC 1969 Edition, N/A Addenda, N/A Code Case (b) Applicable Edition of Section XI Used for Repair/Replacement Activity 2001 ED 12003 Add.

(c) Applicable Section Xl Code Case(s) N/A

6. Identification Of Components National Corrected, ASME Code Name of Name of Manufacturer Board Other Year Removed, or Stamped Component Manufacturer Serial No. No. Identification Built Installed (Yes or No)

HYDRAULIC /IT GRINNELL 13773 N/A RC-R37 1974 REMOVED NO SNUBBER _________ P0: FNP-222 __________ ____

HYDRA ULIC ANVIL 39478 N/A P0: SNA 10090817; 2014 INSTALLED NO SNUBBER _____ _______ ___

7. Description of' W/ork ..... Re.a...snubbe .a.s dule

.as .. uor de...

8. Test Conducted: Hydrostatic Other [] fj PneumaticE--

Pressure ______psi NominalTest Operating Temp. PressureE]

0 F

Exempt [

Page 1 of 2

FORM NIS-2 (Back)

9. Remarks Certificate of Compliance, VT-3 Examination. Equivalency Determination: C09231 3201 Rev. 4.0 Applicable Manufacturer's Data Reports to be attached SNC651 188 CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and that this Replacement conforms to the rules of the ASME Code,Section XI.

Type Code Symbol Stamp N/A Certificate of Authorization N/A Expiration Date N/A Signed ,*/Z//J -&' 4JDI)*,* i',.* / Date -2* /*

Owner or Owner's Designee, Title CERTIFICATE OF INS ER VICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the state or Province of Florida and employed by HSB Global Standards of C have inspected the components described in this Owner's Report during the period ,

to___ *( i*2 *- ,and state that to the best of my knowledge and belief, the Owner has performed examinations and taken co)rrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section Xl.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

In..

/spectors signa'ture* - - National Board, State, Province and Endorsements Page 2 of 2

FORM NIS-2 OWNER'S REPORT FOR REPAIRIREPLACEMENT ACTIVITY As Required By The Provisions Of The ASME Code Section Xl

1. Owner Southern Nuclear Operating Company Date 5/1/20 15 Name 40 Inverness CtrPkwy, Birmingham, AL, 35242 Sheet of2 Address
2. Plant Joseph M., Farley Nuclear P/ant (FNP) Unit FNP UNIT 1 Name 7388 N. State Hwy 95, Columbia, AL 36319 WO#: SNC6531 14 Address Repair/Replacement Organization P.O. No., Job No., etc.
3. Work Performed by FNP Maintenance Department Type Code Symbol N/A Stamp_____________ __

Name Authorization N/A No.__________________ _

7388 N. State Hwy. 95, Columbia, AL. 36319 Expiration N/A Date Address

4. Identification of System P19, Instrument Air System, QIP19HV3611, Class 2
5. (a) Applicable Construction Code ASME Sect. Ill 1971 Edition, Summer 1972 Addenda, N/A Code Case (b) Applicable Edition of Section Xl Used for Repair/Replacement Activity ,,2001 ED/2003 ADD (c) Applicable Section Xl Code Case(s) N/A
5. Identification Of Components National Corrected,' ASME Code Name of Name of Manufacturer Board Other Year Removed, or Stamped Component Manufacturer Serial No. No. Identification Built Installed (Yes or No)

VAL VE PLUG FRASSE N/A N/A HTl' 1204478 1976 REMOVED NO

________PD: FNP2-52 VAL VE PLUG CROSBY K900056-31-0001 N/A P0: QP070339 2007 INSTALLED NO

7. Description of Work Rep/aced valve plugl due to wear.
8. Test Conducted: Other fl El Hydrostatic PneumaticE-Pressure _____psi NominalTest Operating Pressure[*]

Temp. _______ Exemptfl-Page 1 of 2

FORM NIS-2 (Back)

9. Remarks Certificate of Compliance, NPV-1 Form, VT-2 Exam Applicable Manufacturer's Data Reports to be attached SNC6531 14 We certify that the statements made in the report 'CERTIFICATE are correctOFand COMPLIANCE that this Replacement conforms to the rules of the ASME Code, Section Xl.

Type Code Symbol Stamp N/A Expiration Date N/A N/A No.

Certificate of Authorization Expiration Dale N/A Signed Date Signed 4.~J4IL~, lLrkt 4 i.L~c~r

.J Date .*.*_ /

Owner or Owner's Designee, Title CERTIFICATE OF INSER VICE INSPECTION I, the undersigned, holding a valid commission Issued by the National Board of Boiler and Pressure Vessel Inspectors and the state or Province of Florida end employed by HSB Global Standards of Halrtford* CT have Inspected the components described in this Owner's Report during the period .i -/z~oi*il Z to___ eL[*/*o*

nd state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code,Section XI.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described In this Owner's Report. Furthermore, neither the inspector nor his employer shell be liable in any manner for any persona nur rproperty damage or a loss of any kind arising from or connected with this inspection.

Inspector's Signatur6"/ National Board, State, Province and Endorsements Date (//* l Page 2 of 2

FORM NiS-2 OWNER'S REPORT FOR REPAIR/REPLACEMENT ACTIVITY As Required By The Provisions Of The ASME Code Section Xi Date: 5/1/2015

1. Owner Southern Nuclear Operating Company Name Sheet 1 of2 40 Inverness CtrPkwyf Birmingqham, Al. 35242 Unit FNPUnit1 I Address WO# SNC 657815
2. Plant Josep~h M. Farley Nuclear Plant (FNP)

Repair/Replacement Organization P.O. No., Job No., etc.

Name 7388 N. State Hwy 95. Columbia, Al. 36319 Type Code Symbol Stamp N/A Address Authorization No. N/A

3. Work Performed By Expiration Date N/A Name 7308 N. Stete Hwy 95. Columbia, Al. 36319 Address
4. identification of System E21. High Head Safety Injection / Chemical Volume Control System. QIE21 VO61B. Class 2
5. (a) Applicable Construction Code 1971 Edltion, No Addenda, N/A Code Case (b) Applicable Edition of Section XI Used for Repair/Replacement Activity .2001 Edition. 2003 Addenda (c} Applicable Section XICode Case(s) N/A
6. Identification of Components National ASME Code Name of Name of Manufacturer Board Year Corrected, Removed, Stamped (Yes or Component Manufacturer Serial No. No. Other Identification Built or installed No) 2" Needle Dragon Valves TW1140 N/A cJP07065A 2007 Removed Yes Valve 2" Needle Dragon Valves TW1165 N/A QP080471 2008 Installed Yes Valve
7. Description of Work Replaced disc, yoke, union nut, and stem assembly from S/N 1165 an existing valve body S/N TW1140.
8. Test Conducted: Hydrostatic [] Pneumatic [] Nominal Operating Pressure [] Exempt 0]

Other C] Pressure _______psi Test Temp. F

FORM NIS-2 (Back)

9. Remarks NPV-1 [arms, S.IN TW114 a*nd.S5/N TW1165, VT1-2Examrnantion Applicable Manufacturer's Data Reports to be attached woN sNc 657815 CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and that this reelacemient conforms to the rules of the ASME Code, Section Xl. repair or replacement Type Coda Symbol Stamp N/A Certificate of Authorizaton . N/A Expiration Date N/A Owner or Owner's Designee CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the state or Province of Florida and employed by HSB Glolbal Standards of h'artford._CT have inspected the components described in this Owner's Report during the period 6 "4/2-g /Zc, I-to o*'/ i* / 2-o, - . and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section Xl.

By signing this certificate neither the inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described In this Owner's Report. Furthermore, neither the Inspector nor his employer SHALL be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

Inspector's Signature National Board, State, Province and Endorsements Date______________

Page 2 of 2 S~.~-------- ---------- ~