Mark J. Ajluni. P.E.

Southern Nuclear Nuclear licensing Director Operating Company. Inc.

40 Inverness Center Parkway Post Office Box 1295 Birmingham, Alabama 35201 T81 205.992.7673 Fax 205.992.7885 February 15, 2011 SOUTHERN'\\

COMPANY Docket Nos.: 50-348 NL-11-0255 U. S. Nuclear Regulatory Commission ATTN: Document Control Desk Washington, D. C. 20555-0001 Joseph M. Farley Nuclear Plant - Unit 1 Outage Inservice Inspection Summary Report Ladies and Gentlemen:

Southern Nuclear Operating Company (SNC) submits the Joseph M. Farley Nuclear Plant - Unit 1, Interval 4, Period 1, Outage 2 Inservice Inspection Summary Report (Enclosure). This report describes and summarizes the inservice inspection activities performed during the fall 2010 maintenance/refueling outage. Paragraph IWA-6240 of the American Society of Mechanical Engineers (ASME) Boiler and Pressure Vessel Code,Section XI, 2001 Edition with addenda through 2003, requires submittal of the enclosed report.

The supporting inservice inspection documentation, e.g., examination plans and schedules, examination results and reports, examination methods and procedures, evaluation results, and corrective action and repairs, is available for review upon request at Farley Nuclear Plant.

This letter contains no NRC commitments. If you have any questions, please contact Jack Stringfellow at (205) 992-7037.

Sincerely.

~&~

M. J. Ajluni Nuclear Licensing Director MJAlLPH

Enclosure:

Farley Nuclear Plant - Unit 1, Inservice Inspection Report, Refueling Outage (1 R23), Volume 1 Owners Report

U. S. Nuclear Regulatory Commission NL-11-0255 Page 2 cc: Southern Nuclear Operating Company Mr. J. T. Gasser, Executive Vice President Mr. L. M. Stinson, Vice President - Farley Ms. P. M. Marino, Vice President - Engineering RTYPE: CFA04.054 U. S. Nuclear Regulatory Commission Mr. L. A. Reyes, Regional Administrator Mr. R. E. Martin, NRR Project Manager - Farley Mr. E. L. Crowe, Senior Resident Inspector - Farley Mr. P. Boyle, NRR Project Manager

Joseph M. Farley Nuclear Plant - Unit 1 Outage Inservice Inspection Summary Report Inservice Inspection Report Refueling Outage 1 R23 Owners Report

INSERVICE INSPECTION REPORT REFUELING 23 INTERVAL 4 PERIOD 1 OUTAGE 2 J.M. FARLEY UNIT 1 NUCLEAR PLANT Hwy 95 South COLUMBIA, ALABAMA 36319 Southern Nuclear Operating Company 40 Inverness Center Parkway Birmingham, Alabama 35242 Volume 1 Owners Report

INSERVICE INSPECTION REPORT REFUELING 23 INTERVAL 4 PERIOD 1 OUTAGE 2 J.M. FARLEY UNIT 1 NUCLEAR PLANT Hwy 95 South COLUMBIA, ALABAMA 36319 Commercial Service Date: December 1,1977 Southern Nuclear Operating Company 40 Inverness Center Parkway Birmingham, Alabama 35242 February 10, 2011

FNP 1R23 FINAL REPORT INDEX SECTION VOLUME 1 FORM NIS-1 OWNER'S REPORT FOR INSERVICE INSPECTION A

BALANCE OF PLANT/REACTOR VESSEL EXAMINATION

SUMMARY

B EXAMINATION PROGRAM PLAN C

SUMMARY

OF RECORDABLE INDICATIONS 0

FORM NIS-2 OWNER'S REPORTS FOR REPAIRS AND REPLACEMENTS E

VOLUME 2 EXAMINATION RESULTS F

INDICATION EVALUATION REPORTS G

VOLUME 3 PERSONNEL CERTIFICATIONS H

EXAMINATION PROCEDURES (LISTING)

EQUIPMENT CERTIFICATIONS & CALIBRATION BLOCKS (LISTING)

J CALIBRATION BLOCKS (LISTING K

VOLUME 4 FLOW ACCELERATED CORROSION (FAC) EXAMINATION DATA L

VOLUME 1 CONTAINS THE INFORMATION TO MEET THE REQUIREMENTS OF ASME CODE 2001 EDITION, 2003 ADDENDA, SECTION XI, SUBSECTION IWA-6230 FOR SUBMITTAL OF A

SUMMARY

REPORT TO THE NRC FOLLOWING EACH REFUELING OUTAGE.

VOLUMES 2 AND 3 CONTAINS THE SUPPORTING DOCUMENTATION FOR THE EXAMINATIONS PERFORMED (RETAINED ON SITE BY FNP)

DOCUMENTATION OF THE FLOW ACCELERATED CORROSION (FAC)

INSPECTIONS PERFORMED (RETAINED ON SITE BY FNP)

TAB A FORM NIS-1 OWNER'S REPORT FOR INSERVICE INSPECTION

Page 1 of 4 FORM NIS-1 OWNER'S REPORT FOR INSERVICE INSPECTIONS As required by the Provisions of the ASME Code Rules

1.

Owner Southern Nuclear Operating Company 40 Inverness Center Parkway Birmingham. Al. 35242 (as agent for Alabama Power Co.)

(Name and Address of Owner)

2.

Plant J. M. Farley Nuclear Plant Hwy 95 South Columbia. Al. 36319 (Name and Address of Plant)

3.

Plant Unit J.

4.

Owner Certificate of Authorization (if required)

NIA

5.

Commercial Service Date 12/01/77

6.

National Board Number for Unit see listed N. B. for each component

7.

Components Inspected Manufacturer Component or Manufacturer or Installer State or National Appurtenance or Installer Serial No.

Province No.

Board No.

Reactor Vessel Combustion CE 69105 N/A 21385 Engineering Pressurizer Westinghouse 1561 N/A W10793 Tampa Steam Gen A Westinghouse ALAD-40307 N/A 73 Pensacola Steam Gen B Westinghouse ALAD-40308 N/A 74 Pensacola Steam Gen C Westinghouse ALAD-40309 N/A 75 Pensacola Reactor Westinghouse RCPCP1-1 N/A N/A Coolant Pump A

Reactor Westinghouse RCPCP1-2 N/A N/A Coolant Pump B

Residual Heat Ingersoll Rand 117018 N/A N/A Removal Pump A

Class 1 Piping Daniel N/A N/A N/A Construction Class 2 Piping Daniel N/A N/A N/A Construction

8. Examination Dates 05/08/09 to 11/15/10
9. Inspection Period Identification: First Period 12/01/07 to 11/30/10
10. Inspection Interval Identification: Fourth Interval 12/01/07 to 11/30/17
11. Applicable Edition of Section XI_--=2:,;:0:.::0.....1____.Addenda 2003
12. DatelRevision of Inspection Plan:

Volume 1 - 04/30/10, Version 6.0; Volume 2 08/03/10, Version 4; Volume 3 - 01/07/10, Version 2: Volume 6 -10/16/09, Version 2

Page 2 of4 FORM NIS*1

13. Abstract of Examinations and Tests. Include a list of examinations and tests and a statement concerning status of work required for the Inspection Plan. See Tabs Band C
14. Abstract of Results of Examinations and Tests. See Tab B
15. Abstract of Corrective Measures. See Tab B Note: Supplemental sheets in the form of lists. sketches, or drawings may be used, provided (1) size is 81/2 in. x 11 in., (2) information in items 1 through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.

We certify that a) the statements made in this report are correct, b) the examinations and tests meet the Inspection Plan as required by the ASME Code,Section XI, and c) corrective measures taken conform to the rules ofthe ASME Code,Section XI.

Certificate of Authorization No. (if applicable)

N/A Expiration Date ___=~______

Date "2/1 2oA-Signed Southern Nuclear Operating Co. By"",---p:.A.4:~-"1"-"~-'+---

(Owner)

CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission Issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of 654!?4M:

and employed by HSB-CT of Hartford, ConnecUc t have inspected the components described in this Owner's Report during the period

'tJ to f tfp

,and state that to the best of my knowledge and belief. the Owner has performed exa inatlon and tests and taken corrective measures described in this Owner's Report in accordance with the Inspection Plan and as required by the ASME Code,Section XI.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied. concerning the examinations, tests, and corrective measures described in this Owner's Report.

Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

Commissions /f&W/tf tbtf.li!-7 d'[)IJ National Board, State, Province. and Endorsements rn~~

Page 3 of 4 OWNER'S REPORT FOR INSERVICE INSPECTION DATE:

02/10/2011 OWNER NAME AND ADDRESS:

Southern Nuclear Operating Co.

40 Inverness Parkway Birmingham, Alabama 35242 (as agent for Alabama Power Co.)

NAME AND ADDRESS OF NUCLEAR GENERATING PLANT:

Joseph M. Farley Nuclear Plant Highway 95 South Columbia, Alabama 36319 NAME ASSIGNED TO NUCLEAR POWER UNIT:

Joseph M. Farley Nuclear Plant Unit 1 OWNER CERTIFICATE OF AUTHORIZATION:

NIA COMMERCIAL SERVICE DATE:

12/01/1977 NATIONAL BOARD NUMBER:

See listed NB's for each component NAME OF COMPONENTS OR PARTS OF COMPONENTS INVOLVED:

Representative samples of the following components and systems were examined using nondestructive examination techniques.

CLASS 1 COMPONENT OR SYSTEM SYSTEM ALA SKETCH DESIGNATION Reactor Vessel B11 1-1200,1-1300 Pressurizer B31 1-2100 Steam Generator A, B, C B21 1-3100, 1-3200, 1-3300 Reactor Coolant Pump A, B B41 1-5100, 1-5200 Reactor Coolant System B13 1-4100,1-4101,1-4102,1-4103,1-4104, 1-4105,1-4106,1-4108,1-4109,1-4112, 1-4200,1-4205,1-4207,1-4300,1-4304, 1-4500, 1-4501, 1-4502, 1-4503, 1-4504 Safety In:ection System E11 1-4103,1-4304 Safety Injection System E21 1-4104,1-4112

Page 4 of 4 CLASS 2 COMPONENT OR SYSTEM SYSTEM APR SKETCH DESIGNATION RHR Pump A E11 2-5130 Chemical and Volume Control E21 2-1110,2-1120,2-4509,2-4510,2-4600, 2-4608 Containment Spray E13 2-4702,2-4706,2-4707 Feedwater N21 2-4150 Main Steam System N11 2-4101 RHR System E11 2-4501,2-4504,2-4505,2-4514 Safety Injection E21 2-4526, 2-4528, 2-4536, 2-4537, 2-4539, 2-4615, 2-4617, 2-4622, 2-4630, 2-4634, 2-4635 HYDROSTATIC TESTING:

SEE TAB B NAME OF AUTHORIZED NUCLEAR INSERVICE INSPECTOR: James Haubrich NAME AND MAILING ADDRESS OF INSPECTOR'S EMPLOYER:

Hartford Steam Boiler Inspection and Insurance Company of Connecticut One State Street Hartford, CT 06103 ABSTRACT:

SEE TAB B

TABB BALANCE OF PLANT EXAMINATION

SUMMARY

J. M. FARLEY NUCLEAR PLANT UNIT NO 1 INTERVAL 4 PERIOD 1 OUTAGE 2 BALANCE OF PLANT EXAMINATION

SUMMARY

INTRODUCTION The ASME Boiler and Pressure Vessel Code,Section XI, 2001 Edition (Code), 2003 Addenda, is the applicable code for conducting inservice inspection activities during the fourth ten-year inspection interval at Farley Unit 1. Examinations and tests required by the Code are scheduled in accordance with "Inspection Program B" as defined in Code paragraphs IWB-2412 and IWC-2412. This "Owner's Reportfor Inservice Inspection" is for those first inspection period examinations and tests which were performed between May 7, 2009 (date of last examination performed during the twenty-second maintenance/refueling outage, 1 R22 14 1-1) and November 17, 2010 (date of last examination performed during the twenty-third maintenance/refueling outage, 1R23/4-1-2).

The examinations were performed in accordance with the approved Outage Plan. The primary areas of examination included Pressurizer and Steam Generator dissimilar metal welds and various Class 1 and Class 2 piping welds and supports. The tables documenting the Class 1 and 2 vessel and piping examinations as well as component supports examined are under Tab C of this report.

Farley Nuclear Plant has implemented ASME Section XI, Appendix VIII, "Performance Demonstration for Ultrasonic Examination Systems," as required by 10CFR 50.55a, amended by the Federal Register Notices 64 FR 51370 dated September 22,1999, as later modified by 69 FR58804, dated October 1, 2004. The 2004 Rule incorporated the 2001 Edition with NRC caveats. Farley has, except where requests for relief, technical alternatives or exemptions have been approved, complied with the requirements for expedited implementation of the applicable Appendix VIII supplements using the EPRI Performance Demonstration Initiative (PDI).

In addition to the summary of inservice inspection activities, this report addresses Code-applicable repairs and replacements documented at FNP-1 since 1R22 through the end of 1R23. Class 1 and Class 2 Owner's Reports for Repairs or Replacements (Form NIS-2) are provided herein.

It should be noted that an arrangement with an Authorized Inspection Agency was provided for those examinations and tests required by the Code. ASME Section XI examinations and tests are itemized in the applicable sections by reference to Examination Category. Examinations which do not meet the Code required coverage either reference request(s) for relief or indicate that additional relief is required.

This report does not include a summary of the Steam Generator Tube Inspections which are required per FNP Technical Specification 5.6.10. This in normally provided in a separate report one hundred eighty (180) days after the initial entry into MODE 4 following completion of an inspection performed in accordance with Technical Specification 5.5.9.

RESULTS Certain examinations resulted in recordable indication areas being noted on the basis of procedure recording criteria, which generally are more conservative than specified in the ASME Section XI Acceptance Standards. Indications were evaluated and dispositioned by Indication Evaluation Reports (IER's). A listing of IER's is attached and the data sheets are available at FNP for review. The results are summarized below.

SUMMARY

OF INDICATIONS CLASS 1 (A)

VOLUMETRIC EXAMINATIONS There were no reportable Class 1 Volumetric indications.

Five (5) Class 1 welds had limited volumetric coverage during UT examinations because of physical limitations due to the geometric configuration of the welded areas. More than ninety percent (90%) of the required volume must be examined as addressed in ASME Section XI Code Case N-460 for adequate ASME Section XI Code-required examination coverage to be attained. As noted herein, the subject code case has been approved by the NRC for use as documented in NRC Regulatory Guide 1.147. It is impractical to achieve the ASME Section XI Code-required coverage due to the geometric configuration of the welded areas. These limited examinations will be submitted to the NRC through the relief request process as allowed by 10 CFR 50.55a.

(8)

SURFACE EXAMINATIONS There were no reportable Class 1 Surface indications.

(C)

VISUAL EXAMINATIONS There was one reportable Visual indication on a stud from the B steam generator primary bolting. The threads were damaged and the stud was replaced. This was documented in IER 003 and Farley Condition Report (CR) 2010115324.

There were four (4) bolted connections from the Class 1 pressure tests with various degrees of boron accumulation. In each case the boron was removed and either an evaluation or a re examination found each one acceptable.

CLASS 2 (A)

VOLUMETRIC EXAMINATIONS There were no reportable Class 2 Volumetric indications.

There were no Class 2 limited Volumetric examinations.

(8)

SURFACE EXAMINATIONS There were two (2) Class 2 reportable Surface indications. IER-001 was written to document a PT indication on the integrally welded attachment on the south side of support ALA2-4509-CVC R233 (W8). The indication was compared to the tables in IWB-3500 and it was determined that the indication was "acceptable as is". This was also documented in Farley CR 2010113663.

IER-002 was written to document a PT indication on pipe weld ALA2-4615-14. The indication was compared to the tables in IWB-3500 and it was determined that the indication was "acceptable as is". This was also documented in Farley CR 2010114434.

(C)

VISUAL EXAMINATIONS There were no reportable Class 2 Visual indications.

2

There was one (1) bolted connection from the Class 2 pressure tests with boron accumulation.

The boron was removed and the re-examination found acceptable results.

ADDITIONAL EXAMINATIONS The following is a summary of additional examinations which were performed during this outage in accordance with the 2001 Edition, 2003 Addenda of ASME Section XI:

  • Class 1 System Leakage Testing In accordance with IWB-5210(a), a system leakage test of the Class 1 Reactor Coolant System Pressure Boundary was performed prior to startup following the 23rd refueling outage.

In addition, to meet the requirements of IWB-5222(b), the boundary of this system leakage test was extended to include all Class 1 pressure retaining components. This testing was completed on 11/15/2010. There were fourteen (14) recorded indication of leakage. In each case, the boron was removed and necessary corrective actions were taken. The results of this testing is documented in FNP-1-STP 157 as Indication Evaluation Report 001 (IER 001).

To meet the requirements of IWA-5242(a), insulation was removed from all insulated Class 1 pressure retaining bolted connections for VT-2 visual examination after the system was depressurized. There was a total of total of twenty-four (24) pressure retaining bolted connections which had some degree of boron accumUlation. In each case, the boron was removed and any necessary correction actions were taken. The results of this testing is also documented in FNP-1 STP-157 as Indication Evaluation Report 001 (IER 001).

  • Class 2 System Leakage Testing In accordance with IWC-5210(a), system leakage testing was performed during the 23'd refueling outage on portions of the following systems: Residual Heat Removal, Chemical and Volume Control, Safety Injection, and Containment Spray. There were forty (40) recorded indication associated with these tests. In each case, necessary corrective action was performed. The results of this testing is documented in FNP-1-STP-156.2.

IWE/IWL Examinations No examinations were performed in the 1 R23 outage.

STATUS OF EXAMINATIONS REQUIRED FOR CURRENT INTERVAL This 1 R23 Outage was the 2nd Outage, 1 51 Period of the 4th Interval. The results from this outage, combined with the "scheduled" examinations from the previous refueling outage (1 R22, Spring 2009) will represent 100% of the total Class 1 and 2 scope for the current period and interval. Farley Unit 1 is within ASME Code compliance, pending NRC approval of the volumetric and/or surface examination limitations. Requests for relief will be submitted within the required time frame specified by 10 CFR 50.55a. See Table 1 for completion percentages.

  • Applicable Code Cases The applicable Code Cases for the 1 R23 Outage included:

N-460 N-700 N-729-1 N-663 N-722 3

-~

Farley Unit 1 1R23 Outage Completion Percentages

~-~

Percent Of Total Exams 1R22 Code Cat.

Item No.

Population Population Required Required During No. of Exams

% of Total Exams Case To Be Examined 4th Interval Completed Completed 8-A B1.11 3

100%

3 0

0%

B-A 81.12 4

100%

4 0

0%

i-~~

~-

B-A B1.21 2

100%

2 0

0%

B-A 81.22(2) 6 100%

6 0

0%

I B-A 81.30 1

100%

1 0

0%

Total:

16 16 0

0%

B-B B2.11(1 )

2 100%

2 1

50%

B-B B2.12 2

100%

2 1

50%

~-~

~-~

~-

8-B B2.40 3

33.33%

1 0

0%

Total:

7 5

2 40%

-~~

--~

8-D B3.100 6

100%

6 0

0%

B-D B3.110 6

100%

6 1

17%

~~~ ~---~

8-D B3.120 6

100%

6 1

17%

~-~

--~

B-D B3.140(1 )

6 100%

6 2

33%

B-D 83.90 6

-~

100%

6 0

0%

I Total:

30 30 4

13%

-~

8-F B5.10(1) 6 100%

6 0

0%

B-F B5.70(1) 6 100%

6 1

17%

Total:

12 12 1

8%

i-~~

~--~

I 8-G-1 86.10 1

100%

1 1

100%

I B-G-1 B6.180 3

33.33%

1 1

100%

8-G-1 B6.190 3

0%

0 0

0%

I I

4

Farley Unit 1 1R23 Outage Completion Percentages Percent Of Total Exams 1R22 Code Cat Item No.

Population Population Required Required During No. of Exams

% of Total Exams Case To Be Examined 4th Interval Completed Completed B-G-1 B6.20 1

100%

1 1

100%

B-G-1 B6.40 1

100%

1 0

0%

-=-----

c--- ----

B-G-1 B6.50 1

100%

1 1

100%_~

Total:

10 5

4 80%

I i

B-G-2 B7.20 1

0%

0 0

0%

B-G-2 B7.30 6

100%

6 6

100%

B-G-2 B7.50 9

33%

3 3

100%

B-G-2 B7.60 3

33%

1 1

100%

B-G-2 B7.70 24 20%

5 1

20%

Total:

43 15 11 73%

N-663 &

B-J B9.11(1)

N-460 360 25%

94 22 23%

B-J B9.21(1) 55 25%

16 5

31%

B-J B9.31(1) 14 25%

3 0

0%

B-J B9.32(1 )

24 25%

4 2

50%

B-J B9.40(1L 244 25%

58 8

14%

1------

1--------

Total:

697 175 37 21%

I B-K B10.10 1

100%

1 1

100%

B-K B10.10(R)

N-700 3

33.33%

1 0

0%

B-K B10.20 37 12%

5 1

20%

i I()tal:_

41 7

2 29%

I I

B-L-2 B12.20 3

0%

0 0

0%

Total:

3 0

0 0%

5

Farley Unit 1 1R23 Outage Completion Percentages Percent Of Total Exams 1R22 Code Cat.

Item No.

Population Population Required Required During No. of Exams

% of Total Exams Case To Be Examined 4th Interval Completed Comoleted B-M-2 B12.50(1 )

4 25%

1 1

100%

B-M-2 B12.50(2) 6 0%

0 0

0%

8-M-2 812.50(3) 5 0%

0 0

0%

B-M-2 812.50(4) 3 0%

0 0

0%

B-M-2 812.50(5) 6 0%

0 0

0%

Total:

24 1

1 100%

B-N-1 B13.10 1

100%

1 1

100%

I Total:

1 1

1 100%

8-N-2 B13.60 4

100%

4 0

0%

Total:

4 4

0 0%

B-N-3 B13.70 1

100%

1 0

0%

Total:

1 1

0 0%

B-O B14.10 38 18.3%

7 0

0%

Total:

38 7

0 0%

C-A C1.20{1 )

3 33.33%

1 0

0%

C-A C1.30(1 )

3 33.33%

1 0

0%

Total:

6 2

0 0%

CoB C2.21 (1) 33.33%

1 0

0%

C-8 C2.22(1 )

3 33.33%

1 0

0%

Total:

6 2

0 0%

6

Farley Unit 1 1R23 Outage Completion Percentages Percent Of Total Exams 1R22 Code

~,~

Cat.

Item No.

Population Population Required Required During No. of Exams

% of Total Exams Case To Be Examined 4th Interval Completed Completed C-C C3.10 6

16.666%

1 0

0%

~-~

C-C C3.20 210 10~1%

22 8

36%

C-C C3.30 12 10%

2 0

0%

Total:

228 25 8

36%

i C-F-1 C5~11(1)

N-663 876 7.5%

68 6

9%

~-~

C-F-1 C5.21{1 )

402 7.5%

28 1

4%

I I

C-F-1 C5.30(1) 338 7.5%

26 13 50%

I C-F-1 C5.41(1) 18 7.5%

1 1

100%

I Total:

1634 123 21 17%

I C-F-2 C5.51(1) 210 7~5%

25 5

I 20%

I C-F-2 C5.61(1) 12 7.5%

1 0

0%

C-F-2 C5.81(1 )

24 7.5%

2 1

50%

I Total:

246 28 6

21%

I

~-~

-~~~- ~~~ ~--~~

D-A D1.10(1}

10 44%

5 0

0%

D-A D1.20 303 10.8%

33 9

27%

~~~~

Total:

313 38 9

24%

~-~

F-A F1.10A(1 )

7 25%

2 0

0%

-~

F-A F1.108(1 )

56 26%

15 5

33%

F-A F1.1 OC(1) 31 25%

8 3

37%

I

-~

F-A F1.10D(1 )

65 27%

18 6

33~

F-A F1.10E(1) 41 24%

10 4

40%

F-,A._

F1JOE(1) 1 0%

0 0

0%

I 7

Farley Unit 1 1R23 Outage Completion Percentages Cat.

Item No.

Code Case Population Percent Of Population Required To Be Examined Total Exams Required During 4th Interval No. of Exams Completed 1R22

% of Total Exams ComQleted F-A F1.10S(1) 54 27%

12 7

58%

F-A F1.20A(1 )

63 15%

9 3

33%

F-A F1.208(1) 139 14%

20 6

30%

F-A F1.20C(1) 17 28%

5 0

0%

F-A F1.20D(1 )

138 16%

22 6

27%

F-A F1.20E(1 )

81 15%

13 5

38%

F-A F1.20F(1 )

27 15%

4 1

25%

F-A F1.20G(1) 14 20%

3 3

100%

F-A F1.20S(1 )

53 21%

5 1

20%

F-A F1.30A(1) 72 9%

7 2

29%

F-A F1.308(1 }

129 10%

13 3

23%

F-A F1.30C(1 )

5 20%

1 1

100%

F-A F1.30D(1}

334 11%

36 12 33%

F-A F1.30E(1 )

119 12%

16 5

31%

F-A F1.30F(1 )

112 11%

12 5

42%

F-A F1.30H(1) 31 1-------

9%

3 1

i 33%

F-A F1.30S(1 )

24 21%

2 1

50%

F-A F1.40(1 )

72 45%

33 9

27%

Total:

i 1685 269 89 I

33%

8

lABe EXAMINATION PROGRAM PLAN

A5ME Section XI B-N-1 B13.10 B-G-1 B6.10 B-G-1 B6.20 B-G-1 B6.10 B-B B2.12 B-B B2.11(1)

B-D B3.140(1)

B-D B3.140(1)

B-G-2(1 )

B7.30 B-G-2(1)

B7.30 B-G-2(1 )

B7.30 B-G-2(1)

B7.30 B-G-2(1)

B7.30 B-G-2(1)

B?30 N-722 B15.90 B-J B9.11(1)

B-J B9.32(1 )

Examination/Area ALA1-1200-V5INT RPV INTERIOR ALA1-1300-N01 - N58 REACTOR VESSEL NUTS ALA1-1300-501 THRU 5058 REACTOR VESSEL STUDS ALA1-1300-W01 - W058 REACTOR VESSEL WASHERS ALA 1-2100-3 PZR UPPER SHELL LONG SEAM ALA1-21 00-7 PZR UPPER SHELL TO TOP HEAD ALA1-3100-IR1R SG HOT LEG NOZZLE INNER RADIUS ALA1-3100-IR2R SG CROSS-OVER NOZ INNER RADIUS ALA1-3100-N01-N32 STEAM GEN. NUTS ALA 1-3100-501-532 STEAM GEN. STUDS ALA 1-3200-N01-N32 STEAM GEN. NUTS ALA 1-3200-501-532 STEAM GEN. STUDS ALA 1-3300-N01-N32 STEAM GEN. NUTS ALA 1-3300-501-532 STEAM GEN. STUDS ALA1-4100-1DM-BMV RPV HOT LEG SAFE END BMV ALA1-41 00-4R ELBOW TO SAFE-END ALA1-41 00-18BC BRANCH CONNECTION Farley Unit 1 Class 1 Components Examination Cal Procedure(s)

Block(s)

NMP-ES-024-203

NMP-ES-024-201 NMP-ES-024-504 ALA-36 NMP-ES-024-201 NMP-ES-024-516 APR-?

NMP-ES-024-516 APR-?

NMP-ES-024-513 ALA-54 NMP-ES-024-513 ALA-54 NMP-ES-024-201 NMP-ES-024-201 NMP-ES-024-201 NMP-ES-024-201 NMP-ES-024-201 NMP-ES-024-20 1 I

-t-NMP-ES-024-202 NMP-ES-024-50 1 ALA-62 ALAlAPR-33 NMP-ES-024-301 L ___

Exam/Cal 5heet No(s).

0001 S10F1V022 S10F1U018 S10F1V021 S10F1U020 S10F1U019 S10F1U009 S10F1U008 WO 1090805401 WO 1090805701 NA NA NA NA S10F1V024 S10F1U010 S10F1P014 Results Accept Sat NRI Sat NRI NRI NRI NRI Sat Sat Sat Unsat Sat Sat Accept NRI NRI Remarks Examined all accessible surfaces from PRY Flange to

~ore Plate NA NA NA Examined 1 5 12" per SNC lSI Plan

. 98% Code Coverage NA NA i Exam performed by QC Exam performed by QC iNA IER 003, CR 2010115324 One stud with thread damage Replaced NA NA BMV performed with insulation removed.

50% Code Coverage - Relief Request required.

NA

~~~~

Farley Unit 1 Class 1 Components ASME Examination/Area Examination Cal Exam/Cal Sheet Results RemarksSection XI Procedure(s)

Block(s)

No(s).

8-F ALA1-41 00-26RDM NMP-ES-024-507 ALA-62 S10F1U007 NRI 52.1 % Code Coverage 85.70(1)

SAFE-END TO STEAM GEN~ NOZZLE Relief Request required.

8-J

! ALA1-4101-6 NMP-ES-024-501 ALA-67 S10F1U002 NRI 50% Code Coverage - Relief 89.11(1)

PIPE TO ELBOW Request required.

8-J ALA1-4101-7 NMP-ES-024-501 ALA-67 S10F1UOO3 NRI NA 89.11(1)

ELBOW TO PIPE J

NMP-ES-024-501 ALA-67 S10F1U004 NRI 50% Code Coverage 89.11(1)

PIPE TO VALVE Request required.

8-J ALA1-4102-1 NMP-ES-024-501 ALA-67 S10F1U033 NRI NA 8-J ALA1-4101-8

~~

Relief PIPE TO BRANCH CONNECTION

~)1ill

~~~~

~~-~~

8-J ALA1-4103-1 NMP-ES-024-501 ALA-6 S10F1U011 NRI NA

~89.11(1)

PIPE TO BRANCH CONNECTION ALA-67 8-J ALA1-4103-6 NMP-ES-024-501 ALA-67 S10F1U013 NRI NA 89.11(1)

ELBOW TO PIPE 8-J ALA1-4103-7 NMP-ES-024-501 ALA-67 S10F1U012 NRI NA I

I 89.11(11 PIPE TO ELBOW 8-J ALA1-4103-19 NMP-ES-024-301 I

S10F1P024 NRI NA 89.40(1)

PIPE TO BRANCH CONNECTION 8-J ALA1-4103-30 NMP-ES-024-301 S10F1P025 NRI NA 89.40(1 )

PIPE TO BRANCH CONNECTION 8-J ALA1-4104-23 NMP-ES-024-301 S10F1P013 NRI NA I

89.40(1 )

PIPE TO BRANCH CONNECTION 8-J

' ALA1-4105-1 NMP-ES-024-501 ALA-67 S10F1U032 NRI I

INA 89.11(1)

BRANCH CONNECTION TO PIPE 8-J ALA1-4106-1 NMP-ES-024-301 S10F1P036 NRI NA 89.21(1)

PIPE TO BRANCH CONNECTION 8-J ALA1-4106-10 NMP-ES-024-301 S10F1P033 NRI NA 89.21(1)

PIPE TO PIPE I

I 8-J ALA1-4108-1 NMP-ES-024-301 S10F1P015 NRI NA 89.21(1)

PIPE TO BRANCH CONNECTION 8-J ALA1-4109-2 NMP-ES-024-301 S10F1P029 NRI NA 89.40(1)

PIPE TO COUPLING I-------~

8-J ALA 1-4109-3 NMP-ES-024-301 S10F1P030 NRI NA I

89.40(1)

COUPLING TO PIPE 8-J ALA1-4109-4 I NMP-ES-024-301 S10F1P031 NRI NA 89.40(1 )

PIPE TO COUPLING I

i 2

Farl, Unit 1 Class 1 Components ASME Examination/Area Examination Cal Exam/Cal Sheet Results RemarksSection XI Procedure(s)

Block(s)

No(s).

B-J ALA1-41 09-15BW N MP-ES-024-30 1 S10F1P032 NRI NA B9.21(1)

FLANGE TO PIPE B-J ALA1-4112-3 NMP-ES-024-301 S10F1P022 NRI

! NA B9.40(1 )

ELBOW TO PIPE

-~*NA**

B-J ALA1-4112-4 NMP-ES-024-301 S10F1P023 B9.40(1 )

PIPE TO ELBOW N-722 ALA1-4200-1 DM-BMV NMP-ES-024-202 S10F1V025 Accept BMV performed with insulation B15.90 RPV HOT LEG SAFE END BMV removed.

WOL ALA1-4205-WOL-1 NMP-ES-024-509 AX 8-03 S10F1U023 NRI NA 0-4300 CIRC 8-03 PZR SPRAY NOZZLE OVERLAY B-J

' ALA1-4207-5 NMP-ES-024-301 S10F1P034 NRI I

INA B9.21 (1)

PIPE TO VALVE N-722 ALA1-4300-1 DM-BMV NMP-ES-024-202 S10F1V026 Accept BMV performed with insulation B15.90 RPV HOT LEG SAFE END BMV removed.

B-J ALA1-4304*7 NMP-ES-024-501 ALA-67 S10F1U031 NRI 50% Code Coverage - Relief

_B9.11(1)

PIPE TO VALVE Request required.

WOL ALA1-4500-WOL*1 NMP-ES-024-509 AX 16-03 S10F1U028 NRI NA 0-4300 PZR SURGE NOZZLE OVERLAY CIRC 16-03 WOL ALA1-4501*WOL*1 NMP-ES-024-509 AX 8-03 S10F1U025 NRI NA 0-4300 CIRC 8-03 PZR SAFETY NOZZLE OVERLAY WOL ALA1-4S02-WOL-1 NMP-ES-024-509 NRI

~~

S10F1U024 I

j NA PZR SAFETY NOZZLE OVERLAY 0-4300 CIRC 8-03 I

~~

WOL ALA1-4503*WOL*1 NMP-ES-024-509 AX 8-03 S10F1U026 I

NRI PZR SAFETY NOZZLE OVERLAY I

0-4300 CIRC 8-03 I I

INA WOL ALA1-4504-WOL*1 NMP-ES-024-509 AX 8-03 S10F1U027 NRI

,NA 0-4300 PZR SAFETY NOZZLE OVERLAY CIRC 8-03 '

I I

B-G-1 ALA1-5100-B01 - B24 NMP-ES-024-504 ALA-35 S10F1 U014 I

NRI iNA B6.180 R.C. PUMP BOLTING I

B-G-2(1)

ALA 1*5200-B25 - B36 NMP-ES-024-201 S10F1V023 Sat NA B7.60 RC PUMP SEAL HOUSING BOLTING 3

Farley Unit 1 Class 2 Components ASME Examination/Area Examination Cal Exam/Cal Results RemarksSection XI Procedure(s)

Block(s)

Sheet No(s).

C-F-1 ALA2-1110*3 NMP-ES-024-501 ALA-67 S10F1U015 NRI NA C5.11(1)

LTD DEL TANK SHELL TO HEAD F-A ALA2*1120*CVCS*H662 NMP-ES-024-203 S10F1V019 Sat NA F1.20G(1)

EXCESS LETDOWN DELAY TANKS C-F-2 ALA2-4101-2 NMP-ES-024-502 ALA-65 S10F1U029 NRI NA C5.51(1)

PIPE TO ELBOW C-F-2 ALA2-4101-4 NMP-ES-024-502 ALA-65 S10F1U030 NRI NA C5.51(1 )

PIPE TO ELBOW C-F-2 ALA2-4101*9 NMP-ES-024-502 ALA-65 S10F1UOO5 NRI NA C5.51(1)

VALVE TO PIPE C-F-2 ALA2-4101-10 N M P-ES-024-502 ALA-24 S10F1UOO6 NRI NA C5.51(1)

PIPE TO VALVE ALA-65 C-F-2 ALA2-4101-11BC NMP-ES-024-401 S10F1M001 NRI NA C5.81(1)

BRANCH CONNECTION C-F-2 ALA2-4150-14 NMP-ES-024-502 ALA-65 S10F1U037 NRI NA CS.S1(1 )

PIPE TO ELBOW C-F-1 ALA2-4501*3 NMP-ES-024-501 ALA-67 S10F1U017 NRI NA CS.11(1)

ELBOW TO PIPE C-F-1 ALA2-4501-4 i

NMP-ES-024-S01 ALA-67 S10F1U016 NRI NA C5.11 (1)

PIPE TO ELBOW F-A i ALA2-4504-RHR1.R4 NMP-ES-024-203 S10F1V020 Sat NA F1.200(1 )

TVVO DIRECTIONAL RESTRAINT W/ATTACH C-C ALA2-4504-RHR2-R72 (W8)

NMP-ES-024-301 S10F1P011 NRI NA C3.20 WELDED ATTACHMENT F-A ALA2-4505*RHR10*R28 NMP-ES-024-203 S10F1V001 Sat-NA F1.20E(1)

SWAY STRUT C-C ALA2-4505-RHR10-R45 (WS)

NMP-ES-024-301 S10F1P035 NRJ NA C3.20 WELDED ATTACHMENT F-A ALA2-4509-CVC*R232 NMP-ES-024-203 S10F1VOO2 Sat NA F1.20B(1)

ONE DIRECTIONAL RESTRAINT W/ATTACH C-C ALA2-4509*CVC-R232 (WS)

NMP-ES-024-301 S10F1POO5 NRI NA C3.20 WELDED ATTACHMENT I

C-C I ALA2*4509*CVC*R233 (W8)

NMP-ES-024-301 S10F1POO2 RI IER 001, CR 2010113663.

WELDED ATTACHMENT C3.20 I

Acceptable as is.

4

r-


~~~~~~----------------------------------------_,

Farley Unit 1 Class 2 Components ASME Examination/Area Examination Cal Exam/Cal Results RemarksSection XI Procedure(s)

Block(s)

Sheet No(s).

F-A ALA2-4509-CVC-R232 NMP-ES-024-203 I'

S10F1V015 Sat NA F1.20F(1) 3 DIRECTIONAL RESTRAINT W/ATTACH C-C ALA2-4510-CVC-R225 (WS)

NMP-ES-024-301-S10F1P007 NRI NAI!

C3.20 WELDED ATTACHMENT F-A ALA2-4510-CVC-R230 NMP-ES-024-203 S10F1V003 Sat NA F1.20D(1)

TWO DIRECTIONAL RESTRAINT F-A ALA2-4510-CVC-R231 NMP-ES-024-203 I

S10F1V004 Sat NA F1.20E(1)

SWAY STRUT

~F-A ALA2-4514-SI-RS6 NMP-ES-024-203 S10F1V005 Sat NA F1.20B11)

ONE DIRECTIONAL RESTRAINT F-A ALA2-4514-SI-RSS NMP-ES-024-203 S10F1V006 Sat NA F1.20§1L SWAY STRUT C~F-1i~AlA2:-::-_4-:-:5::-:-2-=-6_--=-3-=-B-::CC-------------t-NMP-ES-024-301 S10F1P001 NRI NA C5.41 1 BRANCH CONNECTION


~

F-A

. ALA2-452S-CVC-A14 NMP-ES-024-203 I S10F1V007 Sat NA F1.20A(1)

ANCHOR C-F-1 ALA2-4536-3 NMP-ES-024-301 S10F1P004 NRI NA

_C5.30(1)

VALVE TO PIPE C-F-1 ALA2-4537-1S NMP-ES-024-301 S10F1P009 NRI NA C5.30(1)

PIPE TO ELBOW

-C-F-1 ALA2-4'-=5-37=---,-19--------- N~M=P--E-S=----,-02-4--3c:-:O:-:1-+-------+----=-S-:-1O-=F~1-PO-1--:0--I---N-R-1-+--N-A -------------------1 C5.30( 1)

ELBOW TO PIPE F-A ALA2-4537-CVC-R611 NMP-ES-024-203 S10F1V008 Sat NA F1.20B(1)

ONE DIRECTIONAL RESTRAINT C-F-1 CS.30(11 ALA2-453S-3 NMP-ES-024-301 VALVE TO PIPE_

I II S10F1P012 NRI NA C-F-1 CS.30(1)

ALA2-4539-5 VALVE TO PIPE NMP-ES-024-301,I I

I S10F1P003 NRI NA C-F-1 C5.11(1)

ALA2-4600-7 PIPETOELBOW NMP-ES-024-501 I ALA--6-7--+'-S-1-0F1U034 NRI NA C-F-1 C5.11(1)

ALA2-4600-S ELBOW TO PIPE NMP-ES-024-S01 II ALA-67 S10F1U03S-NRI NA F-A ALA2-460S-SI-A17 NMP-ES-024-203 I S10F1V009 Sat NA F1.20A(1)

ANCHOR C-F-1

,---C5.30(1)

ALA2-461 5-3 COUPLING TO PIPE

,NMP-ES-024-301 I

S10F1P017 NRI I' NA

.I 5

,---~~--~

Farley Unit 1 Class 2 Components

~-~

~-~

ASME Examination/Area Examination Cal Exam/Cal Results RemarksSection XI Procedure(s)

Block(s)

Sheet No(s).

C-F-1 ALA2-4615*8 NMP-ES-024-301 S10F1P018 NRJ NA

~5:30(1)

PIPE TO COUPLING C*F-1 ALA2-461S-9 NMP-ES-024-301 S10F1P019 NRJ NA C5.30(1 )

COUPLING TO PIPE C-F-1

~24I3f5~14 NMP-ES-024-30 1 S10F1P016 RJ IER 002, CR 2010114434.

C5.30(1 )

PIPE TO ELBOW Acceptable as is.

C-F-1 ALA2-4617-2 NMP-ES-024-301 S10F1P026 NRI NA C5.30(1 )

PIPE TO COUPLING C-F-1 ALA2-4622-16 NMP-ES-024-301 S10F1P027 NRI NA C5.30(1 )

PIPE TO VALVE C-F-1

, ALA2-4630*3 NMP-ES-024-50 1 ALA-67 S10F1U036 NRI NA C5.21(1)

ELBOW TO PIPE C-F-1 ALA2-4634*5 NMP-ES-024-301 S10F1P020 NRI NA C5.30{1 )

ELBOW TO PIPE C-F-1 ALA2-4635*6 NMP-ES-024-301 S10F1P021 NRI NA C5.30(1 )

PIPE TO VALVE

~~A ALA2*4702-CS*R294 NMP-ES-024-203 S10F1V017 Sat NA F1.20S{1 )

HYDRAULIC SNUBBER F-A ALA2-4706-CS4*R11 NMP-ES-024-203 S10F1V016 Sat NA F1.200(1)

TWO DIRECTIONAL RESTRAINT W/ATTACH

~-~

i C-C ALA2-4706-CS4*R11 (WS)

NMP-ES-024-301 S10F1POO8 NRI NA C3.20 WELDED ATTACHMENT F-A ALA2*4 707 -CS1-R20 NMP-ES-024-203 S10F1V018 Sat NA F1.20E(1) f--~

~--~~

~ ~ ~

C-C SWAY STRUT ALA2-4707-CS-R142 (WS)

NMP-ES-024-301 S10F1P028 NRI NA C3.20 WELDED ATTACHMENT F-A ALA2-5130-CS-1 NMP-ES-024-203 S10F1V012 Sat NA F1.40(1)

RHR PUMP (A) Q1E11POO1A F-A F1.40(1)

F-A F1.40(1)

ALA2-S130-CS-2 RHR PUMP (Al Q1 E11 POO1A ALA2-S130*CS-3 RHR PUMP (A) Q1 E11POO1A NMP-ES-024-203 I NMP-ES-024-203 I

I I

S10F1V013 S10F1V014 Sat Sat NA NA I

6

lABD

SUMMARY

OF RECORDED INDICATIONS

ALA

~

~..

SUMMARY

OF RECORDED INDICATIONS 2010 UNIT 1RF23 ITEM INDICATION ACCEPTED PER IER SKETCH ID MONITOR DESCRIPTION DESCRIPTION EVALUATION REPAIRJREPl NUMBER Evidence of Leakage and N/A N/A Pressure Test 160.1-1 X

001 Boron Accumulation

~

!1 i I II

lABE FORM NIS-2 OWNER'S REPORTS FOR REPAIRS AND REPLACEMENTS

OWNER'S REPORTS FOR REPAIRS OR REPLACEMENTS (FORM NIS-2)

The following Owner's Reports for Repairs or Replacements (Form NIS-2) are provided for work activities documented at FNP-1 since the last maintenancelrefueling outage (1 R23) through the completion of the twentieth maintenanceirefueling outage (1 R23). Reports are identified by their respective job number which is denoted on each of the NIS-2 reports. The originals of the NIS-2 reports are filed with their respective packages at the plant site. Only those NIS-2 reports applicable to FNP-1 are included in this report document. Any attachments, e.g., code data reports, etc., referenced in the NIS-2 reports will be made available for review upon request at the plant site.

The NIS-2s for the following job number packages are included herein:

1051500509 1080942033 1051571106 1080942034 1051571175 1080942035 1051571176 1080942036 1052553301 1080942037 1052888701 1080942038 1062842201 1080942039 1062849701 1080942040 1070138723 1082115101 1071658901 1082120801 1072124402 1082121101 1072524001 1082121201 1072954501 1090170301 1072955001 1090677402 1080942025 1090805801 1080942026 1090839501 1080942027 1090839502 1080942028 1090844201 1080942029 1090939901 1080942030 1091054301 1080942031 1091194201 1080942032 1091199502 1091223802 1091290901 1091291301 1091294501 1091334403 1091560501 1091674402 1091921503 1092221201 1092222101 1092222201 1092225101 1092225801 1092225901 1092226001 1092226101 1092226201 1092714401 1092811301 1100371801 1100371901 1101054401 1101055201 1101055202 1101166902 1101192101 1101205502 1101631601 1102430901 1103111801 1103111901 1103184001 1103223901

FORM NI5-2 OWNER'S REPORT FOR REPAJRIREPLACEMENT ACTIVITY As Required by the Provlsloos of 1M ASME Code.Section XI

1. Owner:

Southern Nuclear Operating Co Dala:

November 11, 2010 Name 40 Invernass Cenler Parkway: Blrml(lgham. AL 35242 Sheat 01 2

Address

2. Plan!:

Joseph M. Farley Nuclear Plant (FNP)

Unit:

FNP Unit 1


N.~a-m-e-----------------

naa North State Hwy 95: Columbia, AL36319 Work Order No.:

1051500509 Address Repair/Replscement Organization PO No, Job No, elc.

3. Work Perlormed By:

FNP Maintenance Depar1ment Type Code Symbol Siamp:

NIA Name 7388 Nmlh State Hwy 95; Columbia. AL 36319 Authorization No.:

NiA Address Expiration Date:

NlA

4. Identification 01 System:

Q1P16F5016 Umll A-Train SW Strainer

5. (a) Applicable Construclion Code; Sechon 1II

, 1911 EdiHon, 1971 Winter

Addenda, NIA Code Case Year (b) Applicable Edition of Section XI Used for RepalrlReplacement Activity:

2001 Addenda:

2003 Year (c) Applicable Section XI Code Case(s):

NlA

6. Identiflcallon of Components:

Naijonal Corrected, ASMECode Name of Other Year Name 01 Component Manufacturer Serial No.

Board Removed,or Stamped Manufacturer IdantUlcalion Buill No.

Inslalled (Yes or No) 1-112" Studs (qly:9)

TEXAS BOLT Co.

Ht# J66257 N!A PO: FNP*3Q9 1973 REMOVED NO 1-1/2" Nuts (qty:48)

TEXAS BOLT Co.

HIli 6041021 NIA PO: FNP*309 1974 REMOVED NO 1*112' Siuds (qty:9)

TEXAS BOLT Co.

HIli 8969S91TA FF23 N/A PO: QP090512 2009 INSTALLED NO 1*1/2" Nuts (qly:4B)

TEXAS BOLT Co.

HIli M15693 TR CC40 N/A PO: OP010949 2007 INSTALLED NO

7. DescripUo(l of Work:

REPLACED NUTS AND STUDS

8. Tests Conducted:

Hydrostatic 0 Pneumatic Cl Nominal Operating Pressure 0 Exempt Ia Other Cl Pressure; ______ PSI Test Temp.:

OF NOTE: Supplemental sheets In form of lists, sketohes. or drawings may be used, provided (1) size is a*1/21n. x 11 in_. (2) Information In items 1 through 6 on this report is Included on each sheet, and (3) eaoh sheet is numbered and Ilumber of sheets is recorded at the top of this form.

FORM NIS-2 (Back)

9. AemaJl(s APPJifi,iIbki Ulnuf8C1ursi'ii DillS R8pC(tslt; /iii st/sCll&d Construction coda Qf studs are unknoY;nlrell;renced code year 01 strainer ASME SEC. III, 1971 EOWINTER 1971 AdClenda CL 3 Replacement studs are ot conslruclion ASME SEC.III. 1971 ED. WINTER 1971 Addenda Class 3 ConstructIOn code of Nuts are unknown/referenced code year 01 stl8il1er ASME SEC. III. 1971 ED'wINTER 1971 Addenda Replacement nuts are of construction AS ME SEC.lU. 1971 ED. WINTER 1983 Addenda Class 1 Material Grade Dillerence reconciled by FNP*Q*QCP*22/Coda year reconciled by ASME SEC. XI. Para. IWA*4224 No VT*2 Required CERTIFICATE OF COMPLIANCE I certify that the statements made in the report ara correct and that this conforms to tha requirements of the ASME Code. Saclion XI.

Type Code Symbol Stamp:

NiA Certificate of AuthorlzaUOII N/?

N/A EJ<piratlon Dale:

N/A Signed:

~o "'7

.. Asia O. Jerkins. Maintenance Spl. Support Date:

lIt!/'(

-+--+-----------1 O~ Owner's Designee, TItle f

CERTIFiCATE OF INSERVICe INSPECTION I. the undersigned. holding a valid commission Issued by the National Board of Boller and Pressure Vesse\\lnspectofs and the Stale or Province of

<<~iJ::

and employed by""""=-==-_.;;;.J.________________-I of c.q-'

have Inspected the components described In this Owner's Aspon during Ihe 0

10 Adt;

,and slate Ihalto the best of my knowledge and belief. the Owner rformed examinations an~orrecllve measures descnbed In Ihls Owner's Report In accordance with the requirements of the ASME Code.Section XI.

By signing this certificate neither the Inspector nor his employer makes any warr8l'lty. elCPressad or Implied. concerning Ihe examinations and col'lElOtive measures described in this OWner's Report. Furthermore. neither the Inspector nor his employer shall be liable In any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

Dale: __~:.t:::lj'rj£.l~_---------

10/21/201004:16:06 FNP-0-GMP*O.2 SHARED Figure 1 FORM Nt$-2 OWNER'S REPORT FOR REPAIR/REPLACEMENT ACTIVITY AS Required By The Provisions Of The ASME Code Sectlon XI

1. Owner ___-'S2!o.!!iul!!tb/SelJ.rnuNl!:!!~c!!!i!eliP.l!r;.,llo:!l:p!IImL!l.!!'t!n!l.lgL:C~O!!lmWiR!!!.anwYL-__ Data Name
U! IOV§l!U!!lg Ctr rIMY. a'ham, AI. 35242 Shnt __---I____ o' ___-'2!L-___

(q!lpgent for Alabama poW!!' COmpany)

Addrees flY

2. Plant ______~FI!E!.IrI.Ule;.x.v~Nu~cJ~e!!!;!I!!.rJ;.PI!!!.al.!!nt~_____

UnIt _____--t:.FNLllPiNj'g'&.+I______

NIlITKI HlgbWay95 Soyth, Columbia. AJ, 36319 f~rtey Nyclear Plant wog 10ji1671 106 Adclrllsa RepalrIReplaeementOrganlzallon P.O. No., Job No., etc.

T~Q~~S~S~~__~W~A~____________

Name Authorlza6onNo. ____~Nf"""'"A________

Expllallon Date ______....W.....A"'-________

3. Work Performed by SNOe SIt' De!!lqn
  • Mods Highway 95 South. COlymbia. AI. 36319 4.ldentiftoatlon of System _______,t;;.P1.l.16!,::-:..!Serylo!l!1.l~ce~Wt!Bwt!!u.r::;-~C.!!l1!!2!1!!!1.:3"_________________

S. (a) Applicable ConG1nlct/on Code 1971 edition. Summer 1972, Addenda. __....Nl""A=--__ Code Case (I) Applicable EdIt/on 01 Section XI Used for RepalriReplacement Acllvlty 2091 Ed. 2!l!!3 Add (0) Applicable SectIon XI Code Case($)

NI&

8. ldentlflcatlon of Components ASME Hameof ComDCnel1t Name of Manufacturer Manufacturer SorlalNo.

National Board No.

Olfler ldentiftcatlon Year Built Oorrected, Ramoved,or Installed Code Stamped (Yes or No)

Pump-:~

IXsehHead Byron

.Jackson 721-E.(I216 WA PO#FNP-220 1975 Ramoved Yea DIscharge Head Byron Jackson 508993-7 WA POMQP3875 1

Removed Yes 2 In. PIpe DanIel Constr.

74485 NlA Q1P16H8C2QO.E41111 1978 Removed No 2x2x1121n. lee Daniel Constr.

KS2T N1A Q1P16iiSC200.E4191 1975 Removed No PLlnp Sulzer OBC02140 N1A OP080449 2008 Installed Ves Discharge pIopmp Penn ban Works 6101N-2 487 l!OO6 InstaUod Ves Head e/n 08c02140 2 In. PI,.

OOA0S4337 NlA 0P080236 2006 Installed No

~

Tube 2x2x1121n. Tee

()apI1o/ MIg. Co.

MA23 NlA QPOO22 1985 Installed No

7. Description ofWOItI: _eye existing Byron JaOkSPD lE Service Water pump and portion!! of 8SSqo\\ated plplll9 Bnd replace wllb new SU!z!!r pump and 8SSO'/Jeted pfpfng par P2P 1051571101.
8. Test Conducted:

Hydrostallc 0 Pneumatic 0 Nominal Operating Pressure l'8l Exempt 0 Other 0 Pre8Sure 103 psi Teat Temp.

147 t

Page\\.of2 Version 22

~

10/21/201004:16:12 FNP*0-GMP*0.2 SHARED Figure 1 FORM NIS-2 (Back)

9. Remlll'k& Cgde reconc!llgUon for pump and replacement palia provided In Dep 10516111()1 and J.M. Earley Nuclear E'ant PIeIng Appflcable Manufeelllm"ll Data Reports 10be.. 1IIIId!ed

§M!llflcm!9n SS:11 Qfi!:02, VW. 156. All [!plaC!ment m!d!rl!!l and Plitt! 11m bereln were Installed £MIt Work Omt 1951571108. M!!terlal trWDctl9fl8 tor thIs WO a[! '4798!1. 148921. and 136168.

CERTIFICATE OF COMPLIANCE We certify that the statements made In the report are correct and that this r~conforms to the rules of the ASME Code.Section XI.

re r

re acemllfl TypeCodes~~p Ni4:

I Expiration Dam ___NI,.;:j../t'-l.d:

( _______

CERTIFICATE OF INSERVICE INSPECTION I. the undersigned. holding a valid com~I"lon Issued by the National Board of Boller and Pressure Vessel etors and e state or Province of

."".fY and employed by t-Ka cr of

~~Plf.l!,-'~:;-:;!3:r.:::;r-- have Ins ed e components described In this owner's Report during the period to and state that to the best of my knowledge and belief, the Owner as performed examfna 10 and taken corrective measures described In this Owner's Report In accordance with the requirements of the ASME Code,Section XI.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examlnatfons and corrective measureS described In this Owner's Report. Furthermore.

neither the Inspector nor his employer shaD be liable In any manner for any personal injury or property damage or a losa of eny kind arising from or connected wIth this Inspection.

/?J+y4J Commlslons JilM &J:iJ,,*rz,1

......~"'2I~-*I!3IImlpect~~Or'~8-:Sl~9=DII=-:t=uro~-----

National Board, State, Province and Endorsements Page2of2 Version 2.2

02/08/11 08:06:11 FNP-O-GMP-O.2 FORM NIS-2 OWNER'S REPORT F6WW~~A1R1REPLACEMENT ACTIVITY As Required By The Provisions Of The ASME Code Section XI

1.

Owner Southern Nuclear Operating Company Date June 17, 2010 Name 40 Inverness Center Parkway Birmingham, Alabama 35242 (an agent for Alabama Power Company)

Sheet of 2

Address

2.

Plant Farley Nuclear Plant Unit Name Highway 95 South Columbia, Alabama 36319 P16-WON 1051571175 Address Repair/Replacement Organization P.O. No., Job No., etc.

3.

Work Performed by Southern Nuclear Operating Company/ ES

  • Modlficat/ons Type Code Symbol Stamp NlA Name Authorization No.

NlA Expiration Date __________Nl._:.<1______

Farley Nuclear Plant Address

4.

Identification of System P16/ Service Water

5.

(8) Applicable Construction Code ASME Section III Edition, __-=19~7~1__ Addenda, 1971 Code Case (b) Applicable Edition of Section XI Used for Repair/Replacement Activity 2001 Addenda, 2003 (c) Applicable Section XI Code Case(s)

NlA

6.

Identification Of Components National Corrected, ASMECode Name of Name of Manufacturer Board Other Year Removed. or Stamped Component Manufacturer Serial No.

No.

Identification Built Installed (Yes or No)

PUMP SULZER PUMPS ASSEMBLY (US), INC 08C02139 NlA P.O. QP060449 2007 REMOVED YES SUCTION PENN IRON HEAD WORKS, INC.

6101N-6 470 P.O. QP060449 2007 INSTALLED YES PUMP SULZER 08C02145 NlA P.O. QP060449 2007 INSTALLED YES MICHIGAN PIPE SEAMLESS PIPE 111135684 NlA P.O.QP040fl63 2003 REMOVED NlA MICHIGAN PIPE SEAMLESS PIPE A00064337 NlA P.O.QPOB0023 2006 INSTALLED NlA

7.

Description of Work The removed SW Pump lind Dischsrged Hesd was sent off to be refurbished {RefetYlnce P.O. QP100615}

The newly installed refurbished1A SW Pump was Insts/led using Transaction Number 187196 by W.O. 1051571175 and the refurbished Discharged Heed was Installed using Transaction Number 186820 by W.O. 10515711AG. 2 inch Pi". was Installed using Transaction Number 187030.

8.

Test Conducted:

Hydr08ta1ic 0 Pneumatic0 Nominal Operating Pressure I!J Exempt 0 Olher 0 Pressure (89}

psi Tesl Temp.

(Ambient)

OF Page 1 of 2 Version 22

02/08/11 08:07:16 FNP-0-GMP-O.2 Figure 1 FORM NIS*2 (Back)

9.

Remarks The replacement pump was manufactured by SULZER and is a all stainless steel constructed unit. It was acquired under P.O. QP060449.

Applicable Manufacturer's Data Reports 10 be attached The vacuum breaker piping assembly (including component supports) was cui off the removed discharged head to support pump removal and ra-welded back onlo the refurbished discharged head after the replacement pump was installed. Reference W.O.# 1051511115 - See Transaction # 181030.

CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and that this Replacement conforms to the rules of the ASME Code,Section XI.

repair or replacement Signed Date CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boller and Pressure Vessel Inspectors and the state or Province of 6sE@/Jt and employed by USB e:r of IItI#ElD I

~

have Inspected the components described In this Owner's Report during the period t;;¢o to

1-/;0/11
  • and state that to the best of my knowledge and belief, the Owner has performed examinations irldltaken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code,Section XI.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or Implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal Injury or property damage or a loss of any kind arising from or connected with this Inspection.

~ )

Commissions A/tf'lJ6ll! IfIt'C3--7 /t1ll!

Inspector's Signature National Board. State. Provmce and Endorsements Date 2;d~/lJ Page 2 of 2 Version 22

11124110 13:21 :33 FNP-O-GMP-O.2 FORM NI5-2 OWNER'S REPORT F6WYm~AIRlREPLACEMENT ACnVITY As Required By The ProlllsJona Of The ASME Code Section XI

1.

Owner Southem Nucfear Operating COnpanv Dala November 24. 2010 Name 40lnll8f118S$ QIntar PSJlcway BItmInghsm. Alabama 35242 (an lIfl!II! for Alabama Power Company) 8,,"1 1

of 2

Ad<lrea&

2.

Plant F811Sy Nuclear Plsnt Unit 000 Nama H/ghwtty 95 SOfAh Q.lfumbls. Alabama 363t9 pta - WOII 1051571176 Addras.G RepalrlReplacement Organization P.O. No., Job No., etc.

3.

Work Pedormed by Southem MlcItJar Op6rst1ng Type Code Symbol Stamp NlA CommmylES *ModlfJeations Nama AldhOlization No.

AlIA

~onDa.______________________ ___________

FBJ1ay Nuclear Plant

~~~

Address

4.

Identlflcalfon ot System Pts-Servlce Waler S.

(a) Applicable COnattuctJon Coda AIM! Section ft.

Edition, 1911
Addenda, 1971 Code Case (b) Applicable EdItIon 01 Secdon XI Used for Repafr/Aeplacemem Activity...112_00Il0l1__ Addenda, jg (0) Appflcable Seotlon XI Coda CaH(a}

NlA

8.

IdenlIR~on 01 Components National Cotrected.

ASMECode Name of Ntne of Manufaoturer Board Other Yeer Removed. or Stamped ComPonent Manufaoblrer Serial No.

No.

IdentJficallon Built In8laUed (Y"orNo)

PUMP ASSEMBLY SULZER 08C0214C NlA P.O.' QP060449 2OD8 REMOVED l'E"S PUMP (ONLY)

SULZER 8C02141 NtA P.O.' OPOB0449 2008 INSTALLED YeS SS*2889 (PCN4&6)

DANIEL COIVSTR NlA NlA P.o.lI UNKNOWN 1976 REMOVED NO S8-2S69 (PCI4&5}

CMCSTEEL NlA N/A HTfJ J626IJ8 2006 INSTALLED NO 21NOH MICHIGAN N/A IIVA P.O.I QPOBD238 2008 NO PIPE SEAMLESS TUBE HTI 004054337 REMOVED 2/NOH IMCH/OAN P.O.II QP0802S8 PIPE SEAMLESS TUBE NlA NlA HTl00A054331 2006 REPLACED NO DISCHARGE PENN IRON P.O.II 0P08tJ449 HEAD WORK5,INC iliA 486 HTIB101N-1 006 NSTALLED NO

7.

Deectiption of Wortc Replacsd Dlst:harpe Head and SW Pump tor UlIII1 SW Pump QIP18POO1E.

8.

Test Conducted:

Page 1 of 2 Version 22

11/24/1013:19:48 FNP~O*GMP*O.2 Sheet 2 of2 Figure 1 FORM NIS-2 (Back)

9.

Remarks AI' work performed under WQf 1051671176. Pump repaired uod.r fOIl 9p1Q0514.

Discharge Head was repaired under POB QP090507.

AppflC8ble Manufacturer's Data Reports to be atlached CERTIFICATE OF COMPLIANCE We certify that the statemente made In the report are correct and that thle replacement,conforms to the rules olths ASME Code,Section XI.

repaltorrepfacement TVpe Code Symbol Stamp ____________--'m..;;..~O'O"______________I Certfficete of Authorization No.

NIA Explratlon Date _____N.~~

__.....____-i Signed <2:~ s,ik dlJ<,. J'*,.l~oc

~ner or Owner's Designee. title CERTIFICATE OF INSERVICE INSPECTION I, the underSigned, holding a valid commission IlIUed by the National Board of Soller and PI'I88W8 Vesse ctora end the etate or Province of 4fe!'Mtt::

and employed by ti66 e:r-of have In;r;~ components deecrlbed in this OWner's Report during the

___oIP-.iJU.____ to

~

, and state that to the best of my knowledge and belief, the Ow h

performed examinations a d en corrective measures deecrlbed In this Owner's Report In accordance with the requirements of the ASME Code, SectIon XI.

Sy algnlng this certificate neither the Inepector nor his employer makes any werranty, expressed or Implied, concerning the examinations and corrective measures described In this Owner's Report Furthermore, neither the nspector nor his employer 8haII be liable In any manner for any peraonallnlury or property damage or a loIS of any kind arising from or connected with this inspec:tlon.

~

Commissions 1.)1"" Ili'tt,k'lvr tf!J In~8Igneture NatIonal Board, State, Province arid Endorsements D.e____~~~'____----__

Page2of2 Version 22

FORM NIS-2 OWNER'S REPORT FOR REPAIRJREPLACEMENT ACTIVITY As Required by Ihe Provlsloos of tile ASME Code, Sectioo XI

1. Owner:

Southern Nuclear Operating CO.

Date:

November 11, 2010 Name 40 Inverness Cenler Parkway: &rmlOgharn. AL 35242 Sheet:

of 2

Address

2. Plant:

Joseph M. Farley Nuclear Plant (FNP)

Unil:

FNP Unit I Nams 7388 NQrth Stale Hwy 95; Columbia, AL 36319 Work Order No.:

1052553301 Address Repalr/Replscement Olgsnlzation PO No, Job No, etc.

3. Walk Performed By:

FNP Maintenance Departmenl Type Code Symbol Stamp:

N/A Nams 7388 North Slah;' Hwy 95; Columoia. AL 36319 Authorization No.:

N/A Addrass Expiration Dale:

NlA

4. IdenUfication 01 Syslem:

Q1G31VOO7 DW TO SFP ISO

5. (a) Applicable Construclion Code:

Section III 1971 Edition, 1972 Summer Addenda, 1540*1 Code Case

~

(b) Applicable Edition of Section XI Used for Repair/Replacement ActMIy:

2001 Addenda:

2003 Year (c) Applicable Section Xi Code Casses):

NfA

6. IdenUHcallon of Compooents:

National Corrected.

ASME Coda Name of Other Year Name of Component Maoufacturer Senal No.

Board Removed. or Stamped Manufacturer Identification Built No.

Installed (Yes or No)

Vallie Bonnet TT GRINNELL Coq::

73*2779*12.*4 NIA FNP-384 1974 REMOVED YES Valve Bonnet lIT Corporation 83340B*00 j *002 N/A QP090682 1974 INSTALLED YES

7. Description of Wolk:

REPLACED VALVE BONNET

8. Testa Conducted:

Hydrostatic Cl Pneumatic [J Nominal Operating Pressure li2J Exempt Cl OtherC]

Pressure:

_____psl Test Temp.: ______ oF NOTE: Supplemental sheels in form of lis\\s, sketches, or drawings may be used, provided (1) size Is 8-1/2 In. x: 11 in., (2) informallon in Items 1 throug, 6 on this rePOrt is Included on each sheet, and (3) each sheet is ~umbered and number of sheelsls recorded atltle top of this form.

FORM NIS-2 (Back)

9. Remarks APPI'"",61B Mula"lllfsPs DaIs Repotl5 10 &; 811ildled Vallie BOflnerCOI1SlrUCUon code is ASME SEC. Ill. 1971 EO. Tl1m Winter 1972 A<ldenC!a. cc 1540-1 CL 3 Replacement Valve Bonnet ASME SEC. Ill. 1971 ED. Thru Summar 1972 Addenda, wl Code case 1540*' CL 3 Reference Equivalency Determination 1090134101 EO whiCh addresses nunar
  • construcllOfl/malerial dlHerences VT*2 Perlo/med. Sat CERTIFICATE OF COMPLIANCE I certify ll1at the statements made In ll1e report are correct and thai this conlormll to Ihe requirements of the ASME Code.Section XI.

Type Code Symbol Stamp:

Certiflcale of Authorization N~

N/A Expilatlon Dale; N.A Signed:

~ _'I Asia O. Jerkins. Maintenance Sp!. Support Date:

,ft.::L'I

--~~~------------~

OW1IerOf Owner's Designee. Title CERTIFICATE OF tNSERVICE INSPECTION I, Ihe undersigned. holding a valid commission Issued by Ihe National Board of Boller and Pllissure VassellnsPElctors and the Stele or Province of~....6::4::

and employed bY__~_="'__~~__~~_____~___-I of have inspecled the components described in this Owner's Report during the po od

k.

10

~dk

.and stale Ihat to lhe besl of my knowledge and belief. the Own r ha per/ormed examinations and tak6l{co~ctive measures described in this Owner's Report In accordance with the requirements 01 the ASME Code, SscHoo XI.

By signing Ihls certificale nell her the Inspector nor his employer makes any warranty, expressed or imp/led. concemlng the examinations and correclive measures described in Ihls Owner's Report. Furthermore, neilher Ihe Inspector nor his employer shall be liable In any manner for any personal InJury or property damage or II loss of any kind arising rrom or connecled with this Inspection.

Date: --.........{:4~~:.....-------

FORM NIS-2 OWNER'S REPORT FOR REPAIR/REPLACEMENT ACTIVITY As Required by the Provisions of the ASME Coda, SectiOll XI

1. Owner:

Southern Nuclear Operating Co.

Data:

January 18. 2011 Name 40 Inverness Center Parkway; Birmingham. AL 35242 Sheet:

of 2

Address

2. Plant:

Joseph M. Farley Nuclear Plant (FNP)

Unit:

FNP Unil1


N~a-m-B-----------------

7388 North Slate Hwy 95; Columbia. AL 36319 Work Order No.: WO 1052888701 Address RepsrrlReplacement OrganIzation PO No, Job No. ere.

3. Work Performed By.

FNP Malntenance Department Type Code Symbol Stamp:

NlA Name 7388 North State Hwy 95; Columbia, AL 36319 Authorization No.:

NlA Address ExpJration Date:

NlA

4. Identification 01 System:

TPNS: 01N11PV3371C MAIN STEAM ATMOSPHERIC RELIEF VALVE (code class 2)

5. (a) Applicable Construction Code:

Section III

  • 1971 Edition, Summer 72'
Addenda, Nla Code Case

Y6af (b) Applicable Edltion of Section XI Used lor Repair/Replacement Activity:

2001 Addenda:

2003

--~YI~e~s-r---

(0) Applicable Section XI Code Case(s):

NlA

6. Identification of Components:

National Corrected, ASMECode Namsof Other Year Name of Component Manufacturer Serial No.

Board Removed, or Stamped Manufacturer Identification Built No.

Installed (Yes or No)

Bonnet Asher 6014245-3 Nla FNP302 1976 REMVOED YES PrlmaryPlug Fisher 16482-2 Nla OP1337 1987 REMVOED YES Bonnet

'Asher 8183SN8 Nla 40525 1987 INSTALLED YES Primary Plug Asher 273996*10 Nla QP070181 2007 INSTALLED YES

7. Descnplion of Work:

Primary Plug and Bonnet Replacement 8 Tests Conducted:

Hydrostatic [J Pneumatic [J Nominal Operating Pressure fa Exempt Cl Other Cl Pressure:

psi Tesl Temp.:

OF NOTE: Supplemantal sheets In form of lists, sketches, or drawings may be used, provided (1) Size is 8*112 In. x 11 In.* (2) Information in items 1 through 6 on this report is included on each sheet, and (3) each sheel is numbered and number of shests Is recorded at the top ollhis lorm.

FORM NIS-2 (Back)

9. Remalks Replacement Plug is par ASME sec. III. 1971 Edition. Summer 1972 Addenda Replacement Bonnet is par ASME sec. Ill. 1971 Edition. Summer 1972 Addenda VT*2 compteled Sat.

transaction il's: 199038. 198979 CERTIFICATE OF COMPLIANCE Icertify that the statements made in the report are corrEKlt and that this conforms to the requirements of the ASME Code.Section XI.

Type Code Symbol Stamp:

NlA Certiffcate of Authorization No.:

NlA Expiration Date:

NlA Signed:

~7 AsJa O. JerlOns. Maintenance Spt, Support Date: --,-,,-2z-,-,I-,,-,------I

-OWner or Owner's Designee. Title CEATIACATE OF INSERVICE INSPECTION I. the undersigned. holding a valid commission issued by the National Board 01 Boiler and Pressure Vessellnspeclors and the Stale or Province of ~

and employed by_~=~::.-......;c.r;;;..,~-:-____:_-:------:__-._:__:___I of

~~

~

have Inspecled Ihe compooenls described In this Owner's Aeport dUring the periodV~'p to...Lhpla

.and stale that 10 the best of my knowledge and beUef, lhe Owner has perfotmed examinations and taken cofrEKlMmeasures descnbed In this Owner's Report in accordance with the requirements 01 the ASME Code. SEKltion XI.

By signing this celtiflcate neither the Inspector nor his employer makes any warranty. expressed or Implied. concerning the examinations and corrective measures described In this Ovtmer's Report. Furthermore, neither the Inspector nor his employer Shall be liable In any manner for any personal injury or property damage or a loss 01 any kind arising from or connected with this Inspection.

Commissions: JL[j~:l..sM 6;/Iff2.-7 A-w Naliona/ Board, State. Province, snd Endorsements Date:

~AP-1J

FORM NI9-2 OWNER1S REPORT FOR REPAlRJREPLACEMENT ACTIVITY As Required by the Provisions of the ASME Code, Section Xl

1. OWner:

Southern Nuclear Operating Co.

Date:

May 21 2009 Name 40 Inverness Center Parlcway; Birmingham. AL 35242 Sheet:

of 2

Addf9S!J

2. Plan!:

Joseph M. Farley Nuclear Plant (FNP)

Unit:

FNP Unit 1*


~----~~~--------~-----

738S North Slate Hwy 95; Columbia. AL 36319 Work Order No.: G24 - W01062842201 Addrsss Repair/Replacement Organization PO MJ, Job MJ, etc.

3. Work Performed By:

FNP Malntenanoo Department Type Code Symbol Stamp:

NlA Name 7388 North State Hwy 95: O:JIumbia. AL 36319 Aull1ol1zatlon No.:

NlA AddfflSS ExpIraUon Date:

NlA

4. Identification of System:

STEAM GENERATOR SLOWDOWN SYSTEM, ASME Class 2

5. (a) Applicable Construction Code:

See Remarks

,NlA Edition, N/A

Addenda, NlA Code Case Y8:iif (b) Applicable Edition of SactIoo XI Used for Repair/Replacement Activity:

2001 Addenda; 2003 Year (e) Applicable SecUon XI Code Case(s):

NJA

6. Identification of Components:

National Corrected, ASMECode Name of Other Year Name of Component Manufacturer Seriat No.

Board Removed,or Stamped Manufacturer IdentHfcaUon Built No.

Installed (Yes or No)

Mechanical Snubber*

Pacific.. SclenIiflc 38199 NlA QP-1995 1987 Removed NO HydrauDIc Snubber Usage 305004201031 NlA OP060158 2006 Installed NO

7. Description of Work:

Snubber S&4455B was lVp/aced as a scheudUfed upgrade Ref: Transaction 1# 161430

8. Tests Conducted:

Hydrostatic !II Pneumatlc,.

Nominal Operatlng Pressure ill Exempt IaI TestTemp.: _____ oF Other II Pressure: ----psi NOTE~SupplementaJ sheets In Ionn of lists. sketches. or drawings may be USed, provided (1) Size Is 8-11210. x 11 In., (2) inlormallon In Items 1 through 6 on this report Is Included on each sheet. and (3) each sheet Is numbered and number of sheets Is recorded at the 1Dp of this form.

FORM NI8-2 (Back)

9. Remarks Supports DesIgned IoAIC5-1969 and welded loAWS 01.1-86.

Reference equivalency delennlnatlon (LED) 96-0-0225 Rev 1 Rei: Transaction # 161430 CERTIFICATE OF COMPLIANCE I certify 1hat the statements made In the report are correct and It1at this conforms to the requirements of the ASME Code,Section XI.

Type Code Symbol Stamp:

NlA Dale:

" - r-'

--~~~-1------~.;

CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a vaDd commission Issued by the NatIonal Board of Soller and Pressure Vessel Inspectors and the State or Province of

~1t:

and employed by..Q===--.....;;;c:r-;;::..___:--___________-I of have Inspected the components deooribed In !his OMler's Report during th period tJ 10

~,

, and stale that to the best of my knowledge and belief, the Own8l' as rIormed examinations and taken ~measures described In this OMler's Report In accordanC8 with the requirements of the ASME Code,Section XI.

By signing this ceItIfIcate nslttler the Inspector nor his employer makes any warranty. expressed or implied. concemlng the examinations and corrective measures described In this OWner's Report. Furl:hennore, neither the Inspector nor his employer shall be liable in any manner for any personal Injury or property damage or a loss of any klnd arising from or connected with this Inspec1Icn.

Date:

~

\\

~\\

FORM NI8-2 OWNER'S REPORT FOR REPAIRJREPLACEMENT ACTIVITY As Required by the ProvIslons of the ASME Code,Section XI

1. Owner:

Southam Nuclear Operating Co.

Date:

May21, goOO Name 40 Invemess Center ParkWay; BIrmingham, Al 35242 Sheet of 2


~-

Addf8S8

2. Plant Joseph M. Far1ey Nuclear Plant (FNP)

Unit:

FNP Uf)it 1


~------~Na-me-----------------

7388 North state Hwy 95; Columbia, Al 36319 Worlt Order No.: G24* W0106~849701 Address RepafrlR8p1acement Organfzaifof] PO No, Job No. etc.

3. Work Performed By:

FNP Maintenance Depertrnent Type Code Symbol Stamp:

NlA Nama 7388 North State Hwy 95; Columbia, At 36319 Authorization No.:

NJA Address

~ratlon Dale:

NlA

4. Idenllflcalfon of System:.

STEAM GENERATOR BLOWDOWN SYSTEM, ASME Class 2


+1------------

5. (a) Applicable Construclfon Code:

See Remarks

,NlA Edllion, N/A

Addenda, NlA Cockl Case y;,:-

(b) ApplIcable Edition of Section Xl Used for Repalr/Reptacement AcIIvIty:

2001 Addenda:

2003

--~Y,~eM~--

--~-------------

(c) Applicable Section XI Code Case(s):

NlA

6. Identiflcalfon of Components:

National Corrected.

ASMECode Name of Other Year Name of Component Manufacturer Serial No.

Board Removed,. or Stamped Manufacturer ldentfflcalion Built No.

Installed (Yes or No)

Mechanical Snubber Pacific-ScIentific 38221 N/A QP*1995 1987 Remeved NO Hydraulllc Snubber Usage 3050042G'037 N/A QP060158 2006 Installed NO

7. Description of Work:

Snubber SS-4455A was replaced as a scheuduled upgrade Ret TransactiOn '161432

8. Tests Conducted:

Hydrostatic II*' Pneumatic III Nominal Operall1g Prussure iii Other :ell Pressure: ____psi Test Temp.: ____ oF NOTE: Supplemental shael9in form of 1Is1s, sketchee. or drawings maybe used, provided (1) sIZe Is 8-112 in.)( 11 In., (2) informatlon In items 1 through 6 on this report Is included on each sheet, and (3) each sheet is numbered end number ofsheets Is recorded at the top 01 this form;

FORM NI8-2 (Back)

9. Remarlcs Supports Designed to AICS*1969 and welded to AWS 01.1*86.

Reference equivalency determination (LED) 96*()'0225 Rev 1 Ref: Transaction 11161432 CERTIFICATE OF COMPliANCE I certify that lhe statements made In lhe report are correct and lhat lhls conforms 10 lhe requirements of lhe ASME Code, Seclfon XI.

Type Code Symbol Stamp:

NlA NJA expiration Date: _____Nl_A___--a

. Signed:

Leonard Smith Asst MaIm Mgr

~~~~~~+-~~~~~~~--~~----------~-

CERTIFICATE OF INSERVICE INSPECTION I. the undemlgned, holding a valid commission Issued by lf1e National Board of Boller and Pleasure Vesselinspeclors and the 8tateor Provlnced ~

____C.=C;~'____________-f and employed by--,HSa:=B of Ii1tIr7lJtt,p c::r=

have Inspected the components described In this Owner'sReportdurlngthepe~od

/Q/4ii7()7

. to

¥.1fDI4f

,andstatethatto the best of my knowledge and belief, the Owner i4.sPe~exemlnations and taken coiTectl?e measures described In this Owner's Report In accordance with the requirements of the ASME Code, SeelIon XI.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or Implied, c::oncemlng the examinations and colTl!lClllt& measures described In this 0v.11ar's Report. Furthermore, neither lhe Inspector nor his employer shall be liable In any manner for any penronaIlnJury or property damage or a loss of any kind arising from*or connected with this lnspec1lon.

Commissions: GIl-b7 NatIonal Board. State. Provfnce, and Endorsements I

if Form NIS*2 Owner's Report for Repairs or Replacements RType : Ll.S2 As required by the provisions of the ASME Code Section XI Job Number PI6-DCP-I070138701*01 Sheet I of 3

1. Owner
2. Plant Unit Southern Nuclear Operating Company Farley Nuclear Plant FNP I

46 Inverness Center Parkway Highway 95 South Birmingham, Alabama 35242 Columbia, Alabama 36319 Date (as agent for Alabama Power Company 217111

3. Work performed by Type Code Symbol Stamp N/A Name: Southern Nuclear Operating Company Outage aDd Modifications Authorization Number N/A Address :

,IoseI!h M. FarleI ~yclea!; flant Expiration Date N/A

4. Identification ofSystem and ASME Class P16 SERVICE WA'IER. ASME CLASS 3
5.

(a) Applicable Construction Code:

19 Edition

Addenda,
  • 7 Code Case Case (b) Applicable Section XI Utilized For Repairs Or Replacements, 20 01 Edition 2003 Addenda.

N/A (c) Applicable Section Xl Code Case(s):

N/A

6. Identirn:ation of Components Repaired or Replaced and Replacement Components:

Name of Name of Manufacturer National Other Year Corrected, ASME Component Manufacturer Serial Number Board Identification Built Removed or Code No.

Installed Stamped (Yes/No)

QIPI6FV3009C VALVB ITIHAMMEL-7218475/041 N/A 1975 REMOVED YES FN?269 DAHL QIPI6FV3009C VALVE FISHER 18406553 7569 2008 INSTALLED YES Q1'070923 PI6-HBC46 PIPE ORINNEL N51560 N/A 1973 REMOV8D NO FNP*210 PI6*HCC46 PIPE SWEPCO 606221 NlA 2008 INSTALLED NO QP08089 I 20"3000 PI6-HBC46 ORIFICE GRINNEL 6031091 N/A 1913 REMOVED NO FNP-210 FLANGE 20" 300#

PI6-HCC46 ORIFICE WESTERN FORGE 46098 NtA 2008 INSTALLED NO QI'080891 FLANGE 20" 15011 PI6*HBC46 GRINNeL 678 NlA 1973 REMOVED NO FLANGE FNP-210 20"150#

PI6-HCC46 WELD NECK WESTERN roRGE 245795 NtA 2008 INSTALLED NO QP08089 I FLANGE 20"150#

PI6-HCC-46 SLIP ON WESTERN FORGE 245795 NlA 2008 INSTALLED NO QP08089 I FLANGE I W'STUDS UNKNOWN UNKNOWN NtA NIPI6FE3009C UNKN REMOVED NO OWN I \\4" NUTS UNKNOWN UNKNOWN NtA NIPI6FB3009C UNKN REMOVED NO OWN I 118" STUDS UNKNOWN UNKNOWN NtA UNKNOWN UNKN REMOVED NO OWN

  • ' Form NlS*2 Owner's Report for Repairs or Replacements RTyp;! : Ll.S2 As required by the provisions of the ASME Code Section XI Job Number P16-DCP-I070138701-01 Sheet, 2 of 3 I 1/8" NUTS UNKNOWN UNKNOWN N/A UNKNOWN UNKN REMOVED NO OWN

&,.Pe><]o11.-o

.MACK-;.,,v 1~t~~

I W'STUDS NOVBMAGUIl' g~~ N/A 2009 INSTALLED NO I/f,1

. PROBI:IGfS QJf!W.':~/I'

I W'NUTS NOVE MACHINE M23663 N/A QP091090 2009 INSTALLED NO PRODUCTS 11/8" STUDS NOVE MACHINE 3005167 N/A QP091090 2009 INSTALLED NO PRODUCTS

! II8"NUTS NOVE MACHINE 2!i1897 N/A QP09I090 2009 INSTALLED NO PRODUCTS

7.

D~ripdoD of Work Replaced Q1P16FV3009C. installed 4 new flanges and replaced a portion of carbon steel pipe with stainless sleel pipe per DCP 1070138701 and WO 10701387:23.

8. Test Conducted o HydrostatIc o Pneumatic t8l Normal Operating Pressure o Exempt o Other Pressure 100 PSI Temperature ~ OF

.' Form NIS-2 Owner's Report for Repairs or Replacements RType : Ll.S2 As required by the provisions of the ASME Code Sect.ion XI Job Number PI6*DCP-I 070138701-0 I Sheet 3 of 3

9. Remarks (Applicable Manufacturer's Data Reports to be attached)

,. Construction Code for valve: ASME Section m. 1971 Edition. Summer 72 Addenda Construction Code for piping components: ASME Section III. 1971 Edition, Summer 71 Addenda Valve Q1P16V3009C wa$ replnced per WO 1070138723. See transaction It 187689 for applicable material issue information.

One 20" 300# weld neck orifice flange forQ1P16FE3009C and (24) 1'A" studs and (48) 1l4" nuts were replaced per WO 1070138723. See transaction 11186174 nnd 11187496 for applicable material issue information.

Two slip-on 20" 150# flanges and (40) I 1/8" studs and nuts were installed per WO 1070138723. See lOU154<:lion# 187175 and 1/ 187496 for applicable material issue infonnation.

One weld neck 20" 150# flange IIlld (20) I 1/8" studs and nuts were installed per WO 1070138723. See transaclion# 186714. and 187496 for applicable material issue information.

20" Sch 40 pipe was installed per WO 1070138723. See transaction #' 186174 for applicable ltlllterial issue informntion.

VT-21ecl< test was performed per work order 1070138723.

Certificate of Compliance I certify that the statements made in the report are correct and this conforms to the rules of the ASME Code,Section XI.

Type Code Symbol Stamp N/A Certificate of AU!hOri.-hn Number N/A Expiration Date N/A S~gnedP W

.1 I.tl Plant MODS Suoervisor Date Owner or Owner's Designee, Title Certificate of Ioservtce Inspection I,!he undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Pi:ovince of

~1It:

and employed by ~

t:::-/'-

of c;;_:7......

have inspected the components described in this Owner's Re ort during the period

~ v~

to

~~/I

,and state that to the best of my knowledge and belief. the Owne has rformed examinations and e~ rrective measures described in this Owner's Report in accordance with the requirements of the ASME Code,Section XI.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or loss of any kind arising from or connected with this inspection.

Commissions National Board, State, Province. and Endorsements Date

"'I"

,. ~.' -..

),as

': :; °If.>.

c.,~,lul.iC:lioil;"~lid "'OI.klllliUlllhIIP.I;~I~li(~'l'!.~.:~~ ~~"'~~\\lO!llli.:tlftU.......;;......:3:..:..;,*.*+'.~;.;.,{.:.,._~~'...,,..:.-._

f,';( ':'....

~~~~__~_

N'O.~~__~~~~__~~__~~

FORM NlSo2 OWNER'S REPORT FOR REPAIR/REPLACEMENT ACTIVITY As Required by the Provisions of the ASME Code. Secllon XI

1. Owner:

Soulhem Nuclear Operating Co.

Date:

December 6.2010 Name 40 Inverness Center Palkwar, Birmingham. AI. 35242 Sheet:

of 2

Addmss

2. Plant:

Joseph M. Faltev Nuclear Plant (FNP)

Unit::

FNP Unit 1


~------M9~me--*-*----~~----~

7388 North State Hwy 95; Columbia, AL 36319 WorkOrderNo~* WO 1071658901 Address R6pairiRspiacement OrganIZation PO N(J; J(J/) No. ere*.

3. Work Periormed By:

FNP Maintenance Department Type Code Symbol Stamp:

NlA Name 738a North State Hwy 95; Columbia. AI. 36319.

Authorization No.:

N/A Address Expiration Dater.

NlA

4. ldenliflcatlon of Systemt TPNS: 01E21POO2A lA CHG PUMP (code class 2)
5. (a) Applicable ConstrucUon CQder, Secllon III

, 1968 Edition. wI Sum 1968 Addenda.

N/a

. Code Case

~

(b) Applicable Edition of SectIon XI Used lor RepairlRepiacement ActMty:;*

2001 2003 Ysaf (c) Applicabkt SeCtIon XI Code Case(!I)~:

N/A 6, ldenliflcation 0' Components:.

NaIlonai Corrected.

ASMECode Nemeof Other Year Name 0' Component Manufacturer Serial No.

Soard Removed,or Stamped Manufacturer Identification Built No.

Installed (Yes or No)

Seal Housing (Inboard)

Flowserve HTI#521 0 RLSA07954 N/a OP050820 2005 REMOVED YES Seal Housing (outboard)

Flowserva HIlt 2E229-AK Nla QP3929 198a REMOVED YES Seal Housing (Inboard)

Flowserva RLSAl3053 N/a QPOOO230 2005 INSTALLED YES Seal Housing (outboard)

Flowserva ALSAl3054 Nla OP090230 1986 INSTALLED YES

7. Description of Work!

REPLACEMENT Pump Seal Housinlls 8.. Tests Conducted:

Hydrostatic [J Pneumatic [J Nominal Operating PrBSSUIB E2I Exempt [J Test Temp.; ______OF OIherD


psi NOTE: Supplemental sheets In 'orm of fists; sketches, or drawings may be used, provided (1) siZe Is 8-112 In.; Jt 11 In., (2) Information In Items 1 through 6 on Ihis teport Is Included on each sheet. and (3) each sheet is numbered and number of sheets Is recorded at the lop of Ihls 'orm.

FORM NIS-2 (Back)

9. Remark$ Difference in coda is reconciled In the CFC of PO QP090230 A;liiIiiIiil&iii&iiJiri tG!Impo;& ID 6; iiiJiCJIf!J Replacement Seals ASME 500.1111968. with Wimer 1968 Addenda code class 2 VT*2 completed Sat.

Transaction II's: 18n21 CERTIFICATE OF COMPLIANCE I certify that the statemems made In the report are correct and that this conforms to the requirements of the ASME Code,Section XI.

Type Code Symbol Stamp:

NJA Certificate of Authorization No.:

N/A ElqJ/ralion Date:

NlA Signed:

~ ---;

Asia O. Jerkins. Maintenance Spt. Support Date: -,-,/-J,-',;,-'-r,'..;..;...;..----r

"-OWner or Owners Dssignef1. Tills

--=,-I-'~~------I CERTIFICATE OF lNSERVICE INSPECTION I, the Ul1dersIgned. holdng a valid commission issued by the National Board 01 Boller and Pressure Vessel Inspectors and the State or Province of ~ and employed by.....~~~__'"'-______________--I 01

~

Cd have In~ed the componems described in this Owner's Report during the periJ!

/¢'i?'IJ to j~J;I

. and stale lhat to the best of my knowledge and belief. the Owner has peiformed examinations and takel(corr~tive measures described in lhis Owner's Report In accordance with the requlremenlS of Ihe ASME Code,Section XI.

By Signing this cartificate neither the Inspector nor his employer makes any warranty. expressed or Implied, concerning the examinations and correetlve measures deSCribed In this OWner's Report. Furthermore, neither the Inspector nor his employer shall be liable In any manner fO( any personallnlury or property damage or a loss of any kind arising from or connected with Ihls Inspection.

Date:

--~--~~-------------------

02/07/11 12:39:45 FNP-0-GMP-0.2 Figure 1 FORM NIS-2 OWNER'S REPORT FOR REPAIR/REPLACEMENT ACTIVITY As Required By The Provisions Of The ASME COde Section Xl

1.

Owner Southern Nuclear Operating Company Date 217/11 Name 40 Inverness Clr Pkwy. Binningl1am, AI. 35242 Sneet of 2

Address

2.

Plant Joseph M. Farley Nuclear Plant Unit FNP*1 Name Highway 95 South, Columbia. AI. 36319 WON 10721244fJ2 Address RepairlReplacement Organization P.O. No., Job No., etc.

3.

Work Performed by Williams Power Systems Tvpe Code Symbol Stamp N/A Name Authorlmtlon No.

N/A Farley Nuclear Plant Expiration N/A Date Address

4.

Identification of System Unit 1 Containment Uner Penetration Q1T53PENE84 S.

(a) Applicable Construction Code Sect.lU, CI. B *1968

Edition, No
Addenda, NlA Code Case (b) Applicable Edition of Section XI Used for Repair/Replacement Activity 2001 §!..fition. gooo Addenda (c) Applicable Section XI Code Case(s)

NlA

6.

Identification Of Components National Corrected, ASMECode Name of Name of Manufacturer Board Other Year Removed,or Stamped Component Manufacturer Serial No.

No.

Identification Built Installed (Ves or No) y,," PLATE CHATHAM STEEL HT# E8F130 NlA QP090811 2008 INSTALLED NO

7.

Description of Work Instsfl J2"plates to Containment Penetmtion 01T53PENEB4 reinforcing plate for ladder installation.

8.

Test Conducted:

Hydrostatic 0 PneumaticD Nominal Operating PressureD ExemptD Other 0 Pressure psi Test Temp. _____ OF Page 1 of 2 Version 22

02/07/11 12:39:45 FNP-O-GMP-O.2 Figure 1

9. Remarks

~"plale A516 Gr. 70 was issu!Kl Rer lransaction /I 131572, cl,ll to fil and Inslane<! per MDC# 1072124401 instructions.

Welds were performed by qualified welders using a qyallfied procedure. Welds were examined by MT testinq par NMP-ES-024=401 and the A VT-3 examination was oerfonued per NMP*ES.Q24-2Q4 on the completed assembly, ________________

CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and that this Replacement conforms to the rules of the ASME Code,Section XI.

repair or replacement TypeCodesymboISmmp ______________________________~N/,~~~_________________________~

______--:..NI...::.;:4...:.-____ Expiration Date _____..:.;NI..:.:~..:..____~

Signed Date CERTIFICATE OF INSERVICE INSPECTION I. the underSigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel InsP.8ctors and the smte or Province of "";a:>K4IA=

and employed by $4 c.-r:

of c::r have inspecte th components described in this Owner's Report during the period

'P Ii) to and state that to the best of my knowledge and belief, the Owner h s erformed examinations nd aken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code,Section XI.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore. neither the Inspector nor his employer shall be liable in any manner for any personal InJury or property damage or a loss of any kind arising from or connected with this inspection.

~~.)

Commissions 114/t;¥lr6i'1~7 d:rJl)


:-,~~!iSlei!!;c~to*r~*s~S:::14I.g""'na~t:-u-re-------

National Board, State, Province and Endorsements Date __~~~",--______

Page 2 of 2 Version 22

FORM NIS-2 OWNER'S REPORT FOR REPAIR/REPLACEMENT ACTIVITY As Required by !he Provisions of too ASME Code,Section XI

1. Owner:

Southern Nuclear Oper8hng Co.

Date:

Oec;arnber l. 2010 Name 40 Inverness Center Parkw"y; Birmingham. AL 35242 Sheet:

of 2

Address

2. Plant; Joseph M. Farley Nuclear Plant (FNP)

Unit:

FNP Unit 1 Name 73aB North Slate Hwy 95, Columbia. Al36319 Work Order No.:

WO 1072524001 Address Repair/Replacement Organization PO No. Job No, etc.

3. Work Performed By:

FNP Maintenance Department Type Code Symbol Stamp:

NlA Name 7388 North State Hwy 95. Columbia. Al36319 Authorization No.:

N'A Address Expiration Date:

4. Identiflcation of System:

TPNS. Q1E12HOOO1C lC CTMT COOLER (code class :l)

5. (a) Applicable Construclion Code:

Section fit

  • 1971 Edllion.

thru 112000

Addenda, NIA Code Case

y;;;-

(b) Applicable Edition of Section XI Used for Repair/Replacement Activity:

2001 Addenda:

2003 Year (c) Applicable Section XI Coda Case(s):

NIA

6. Identification at Components:

Nallonal Corrected.

ASMECoda Name of Other Year Nama of Camponenl Manufacturer Ser/al No.

Board RemOVed. or Stamped Manufacturer ldentiflcalion Built No.

Installed (Yes or No)

Studs 51S'wl nulS (18) unknown unknown NJA unknown unk REMOVED NO Stud 5/S'wl nul (1)

Dubose NBN43236 N/A QP970S84 1997 INSTALLED NO Studs S/Il"wl nuls (9\\

Nova Machme 50 16908Q N!A QP090399 2009 INSTALLED NO Studs S18'w/ nuts (4)

Nova Machine 230111/217100 NlA QP060210 2006 INSTALLED NO Siuds S/S'wf nuts (4)

Nova Ma<:hlne 99694 Nil' QP991140 2000 INSTALLED NO

7. Description 01 Work:

REPLACEMENT STUDS wi NUTS

8. Tests Conducted:

Hydrostatic rJ Pneumatic 0 Nominal Operating Pressure 0 Exempt e1 Other [J Pressure: _____pSi Test Temp.: _____ oF NOTE: Supplemental sheets in form olllsls. Sketches, or drawings may be used, provided (1) size is 8*112 in. x 11 In.* (2) information in items 1 Ihrough 6 on this report is included on each sheet. and (3) each sheet is numbered and number or sheets is recorded at the top of this form.

FORM NIS-2 (Back)

9. Remarils ReplacefnQn! 01 Sluds and Nuts pel ASME Sec\\lon III, NC 1989 no addenda class 2 and !\\SME Sec. III, NC 1983 thru Wtr. 1983 Subsection NC class 2 FNP Piping Specification 5S110902 allows a construction Code of ASME Seclion 111, 1971 Edition thru 2000 Edilion Addenda The Specification requires the material 10 be SA 194 Gr. 2H and SA 193Gr. 87 tor nuts and sluds TransacUQn iI: 198961 CERTIFICATE OF COMPLIANCE I certify that the statements made In the report are correct and that this conforms to the requirements of lhe ASME Code, Seclion XI.

Type Code Symbol Stamp:

N!A Certificate of Authorization No.:

NiA Expiration Date:

N/A


~

Signed:

ASia O. Jerkins. Maintenance Spl. Support Dale:

~"7 I Jt,{' j't Owner's Designee, Tit/a CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by lJ1e Naliona/Board of Boiler and Pressure Vessel Inspectors and the State or Province of

~b!:

and employed bY--':,.t;oC~_"";;~_________________-I of

~? CT

~

have lnspected the components described in lJ1/s Owner's Report d~;;g _

a;..i~

to

, and state that to the besl of my knowledge and belief, the Owner htpertormed examinations and lake Owner's Aeport In accordance with the requirements of the ASME Code,Section XI.

By Signing lJ1is cel1ifleste neither IJ1e Inspector nor his employer makes any warranty. expressed or implied, conceming the examlnadons and corrective measures described In this Owner's Report. Furthermore. neither the Inspector nor his employe/' shall be liable In any manner for any personal injury or property damage 01 a loss of any kind ariSing from or connected with this inspection.

I/l$peCiOf's Signature Date: __~~~a..._________

FORM NIS-2 OWNER'S REPORT FOR REPAIR/REPLACEMENT ACTIVITY As Required by the Provisions 01 the ASME Code,Section XI

1. Owner; Southern Nuclear Operallng Co.

Date:

November :l0. 2010 Name 40 Inverness Center Parkway; Birmingham, AL 35242 Sheet 01 2

Address

2. Plant:

Joseph M. Farley Nuclear Plant (FNP)

Uni!:

FNP Unit 1


N~a-m-9------------------

7388 North State Hwy 95: Columbia, AL 36319 Work Order No.:

WO 1072954501 Address Repair/Replscement Orgsnizaffon PO No, Job No, etc.

3. Work Performed By:

FNP Maintenance Department Type Code Symbol Siamp:

NlA Name 7388 North State Hwy 95: Columbia, AL 36319 Authorization No.:

NlA Addll3SS Expiration Date; N/A

4. Identification 01 System:

TPNS: Q1P16V032B 18 CS PUMP RM COOLER INLET ISO VALVE (code class 3) 5, (e) Applicable Construction Code:

Seelion III

, 1971 Edition, thru A2000

Addenda, N,A Code Csse

YW (b) APPlicable Edition of Section Xl Used lor Repair/Replacement ActMIy:

2001 Addenda:

2003

--~Y~e-a-r---

(c) Applicable Section XI Code Case(s):

NlA

6. Identification of Components:

National Corrected, ASMECoda Name of Other Year Name 01 Component Manufacturer Serial No.

Board RemOVed, or Stamped Manufacturer Idenllfication Buill No.

Installed (Yes or No)

Inlet Nu!s 3/4"-10 UNC (8) unknown unknown NIA unknown unk REMOVED NO Studs 3/4".10UNC 2Ax7.2 unknown unknown N/A unknown unk REMOVEO NO Inlet Nu!s 3/4"*10 UNC (8) Nova Machine Prod 5092414 N/A QP10082 2010 INSTALLED NO Studs 3i""*10UNC 2Ax7.2 NOlla Machine 3008725 N/A QP100560 2010 INSTALLED NO

7. Description 01 Work; REPLACEMENT STUDS AND NUTS
8. Tests Conducted:

Hydrostatic Cl Pneumatic Cl Nominal Operating Pressure Cl Exempt G!I Other 0 Pressure:

Test Temp.: _____ oF psi NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size is 8*1/2 in. x 11 in., (2) information In Items 1 through 6 on this report is included on each sheet, and (3) each sheet is numbered and number of sheets Is recorded at the top 01 this form.

FORM NIS-2 (Back)

9. Remarns APPiiCSbJ.lJan'ul.ctura? Dala Fieport. fo 6".tt:;a;;a Replacement of Stud~ and Nuts per AS ME Section III, NC 1889 no addenda FNP Piping Specification S5 110902 allows a construction COde of ASME Secliorl III, 1971 Edition Ihrw 2000 Edition Addenda Transaction n: 198148 CERTIfICATE OF COMPLIANCE I certify that the statements made In the report are correct and thatlhis conforms to the requirements of the ASME Code,Section XI, Type Code Symbol Stamp:

NiA Certificate of Authorization N;;:;

NIA Expiration Date:

NIA Signed:

~""7 Asia 0, JerkinS. Mamtenance Spt. Support Date:

l/z,f}"

~~~~--------;

19w1fe(or Owner's Designee, Tille CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province 01 and employed by

~

~~--~----------------------~

of

'-1' have inspected the components described in this Owner's Report during the period to

, and state that to

--~~~~-------

the best 01 my knowledge and belief, the Owner h s pe ormed examinelions and take Owner's Report In accordance with the requirements 01 the ASME Code, Seclion XI.

By signing this certitieala nellher Ihe Inspector nor his employer makes any warranty, expressed or implied, concerning the examinatlons and corrective measures described in this Owner's Report. Furthermore, neilher tile Inspector nor his employer shall be liable in any manner for any personallnlury or property damag.ll or a loss 01 any kind arising from or connected with this inspection.

/'

Inspector's Signatute Date:

~

FORM NIS-2 OWNER'S REPORT FOR REPAIR/REPLACEMENT ACTIVITY As Required by the Provisions 01 the ASME Code,Section XI

1. Owner:

Southern Nuclear Operating Co.

Dale:

December 1. 2010 Name 40 Inverness Center Parl\\way; Blrmrngham, AL 35242 Sheet 01 2

Address

2. Plan!:

Joseph M. Fadey Nuclear Plant (FNP)

Unit:

FNPUmll Name iS88 North Stale Hwy 95: Columbia, AL 36319 Work Order No.:

WO 1072955001 Address RepairlReplacement Organization PO No, Job No, etc.

3. Work Performed By:

FNP Maintenance Department Type Code Symbol Stamp:

N/A Name 7388 North Stale Hwy 95; Columbia. AL 36319 Authorization No.:

NJA Address Expiration Date:

N/A

4. Identification of System:

TPNS: 01P16V037D S TRN SW SUPP TO 18 CHG PUMP AM CLA VALVE (code class 3)

5. (a) Applicable Conslructlon Code:

Section III 1971 Edition, thru "2000

Addenda, N/A Code Case Year (b) Applicable Edllion of Section XI Used for Repair/Replacement Activity:

2001 Addenda:

2003 Year (e) Applicable Secllon XI Code Case(s};

NiA

6. Identification of Components:

National Corrected.

ASMECode Name of Other Year Name 01 Component Manufacturer Serial No.

Soard Removed, or Stamped Manufacturer tdentificatlon Built No, Installed (Yes or No)

Inle! Nuts 314"*10 UNe (8) unknown unknown NiA unknown unk REMOVED NO Studs 314"*10UNC 2Ax7.2 unknown unknown NiA unknown unk REMOVED NO Inlel Nuts 314'*10 UNC /B) l'Iova Machine Prod 3008725 NIA QP10082 2010 INSTALLED NO Studs 3f4"*lOUNC 2Ax7,2 Nova Machine 5092414 N/A QP1oo560 2010 INSTALLED NO

7. Description of Work:

REPLACEMENT STUDS ANO NUTS

8. Tests Conducted:

Hydrostatic [J Pneumatic [J Nominal Operating Pressure [J Exempt Ii!]

_____psi Other [J Pressure:

Test Temp.;

OF NOTE: Supptemental sheets in form of lislS, sketches. or drawings may be used, provided (1) size Is 8*112 In. x 11 in., (2) Information in items 1 through 6 on this report is Included on each sheet, and (3) each sheet is numbered and number of sheets is recorded at the top of this form.

FORM NI5-2 (Back) 9 Remarks AppJ.blils Manufaclu",,'S bars Ropei1. to be 8UBCflod R~placemel'lt of Studs and Nuts per ASME Section III, NC 1989 no addenda class 2 and I FNP Piping Specilicalion SS 11 0902 allows a conslruction Code 01 ASME SecliOn III, 1971 Edition thlll 2000 Edilion Addenda The Specificauon requires the material to be SA 194 Gr. 2H and SA 193 Gr.710r nuls and studs Transaction #: 196164 CERTIFICATE OF COMPLIANCE 1certify Ihat the statements made In the report are correct and that this conforms to the requirements of the ASME Code, Section XL Type Code Symbol Stamp:

MiA Certificate of AU1horizalioo No.:

N/A Expiration Dale:

NJA Signed:

ASIa O. JerkIns, Maintenance Spt. Support Date: --,

7"'7.....

.h-'S"-,J,-,-,-----r

'ewrJer Of Owner's Designee, Title

{

l CERTIFICATE OF tNSERVICE INSPECTION I. the undef'$igned. holding a valid commission Issued by the National Board 01 Boiler and Pressure Vessellnapeators and the Slale or Province of ~ and employed by-..Lt';I::oII-->o"'----------________--t of c:z-.

have inspecled the components described in this Owner's Report during the nod

___~?a~~"a----- to

/2::::.$

.and state that to the best of my knowledge and belief. the Owne rformed examinations and take£l'Co~;;tlve measures described In this Owner's Report in accordance with the requirements of the ASME Code,Section XI.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described In this Owner's Fleport. Furthermore. neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss 01 any kind arising from or connected with this inspeclloo.

Commls5ions:..IJ~~~~~~~7~1!J:iJ~~-~~----~

Dale:

FORM NIS-2 OWNER'S REPORT FOR REPAIAiREPLACEMENT ACTIVITY

. As Required by the Provisions of the ASME Code,Section XI

1. Owner.

Southem Nuclear Operating Co.

Date:

December 13.2010 Name 40 Invemess Center Parkway; Birmingham. Al 35242 Sheet.

of 2

Address*

2. Plant.

Joseph M. Farley Nuclear Plant (FNP)

Unit FNP Unit 1


~----~N~ame~----~------~

7388 North Stata Hwy 95; Columbia. Al3S319 Work Order No:; Pia -1000942025 AddrBss RepsldReplscement Organization PO No, Job No, etc.

3. Work Performed By:

FNP Maintenance Department Type Coda Symbol Stamp:

NJA N8m8 7388 North Slate Hwy 95; Columbia, AL 36319 Authorlza11on No.:

NlA Address Elq)frallon Date:

NfA 4, IdentillcatiOn of System:

TPNS: Q1P16V2160 - HCC-29 SW Ratumlrom lC CTMT Coolar Drain (ASME Class 3)

5. (a) Applicable Construction Code:

Section '"

  • 1971 Edillon. Winter 1971 Addenda.

NlA Coda Case

~

(b) ApplIcable EdltJon of SectIon XI Used for AepalrIAeplacement Activity:

2001 Addenda:

2003

--~YI~~-r---

(0) Applicable Section XI Code Case(sr, N/A

6. ldentllk:atlonof Components:

Name of Component Name 01 Manufacturer Manufacturar Sellal No.

National Board No.

Other ldentillcatlon Year Built Corrected.

Removed, or Installed ASME Code Stamped (Yes or No)

PIPE McJunkin L65803 NlA 7047-0-62574 1973 Removed No PIPE TIOGA 285192 NlA OP*1674 1987 Removed No ELBOW HUB R95R N/A OP-2030 1987 Removed No VALVE KEROTEST GSI*8 N/A FNp*295 1974 Removed YES PIPE Sandvik 519775 NlA PO: QP09740 2007 Installed No ELBOW BONNEY FORGE 44013 NlA PO: OPI00I57 2007 Installed No VALVE BNl A070809*1-40 NlA PO: OP070775 2008 Inslalled YES

7. Description of Work:

SW Valve and PiPe Replacement

8. Tests Conducted;;

Hydrostatic [J Pneumatic [J Exempt [J Other[J Pl8SSura:*

Test Temp.r OF

--~-psI NOTE: Supplemental sheets In form of Iis~ sketches, or drawings may be used. provided (1) site Is ~1121n,)( 11 ini~ (2) information In items 1 throtljjl6 on this report Is Included OIl eadl sheet,. and (3) each sheet Is numben:!d and number 01 sheets Is recorded at the top of this form.

FORM NIS--2 (Back)

9. Rem8.lks Reference MOC 1000942001 lor reconciliation of malerial difference APii/bi&\\i~DIIli /fOiiifiii /0& ~&di/;ti..

. Valve Code 01 contruction and replacement valve code is ASME sec. III. 1971 edillon. winter 1971 Addenda wI para NOOll1.1C of Winter 1972 Addenda. class 3 Replacement pipe Is A5ME Sec. II & III. Subsection ND. 1986 Edition no addenda. class 3 Replacement Elbow pipe is ASME Sec. II & III. Subsection ND. 1983 Edition no addenda. class 3 FNP Piping SpecUicalion S511 0902 allows a construction Code of ASME Section III. 1971 Editfon ttiru 2000 Edition Addenda VT-2 completed Sat.

Transaction II's: 190050 CERTIFICATE OF COMPLIANCE I certify tIlat the statements made In the report are correct and that this conforms 10 the requirements of the ASME Code.Section XI.

Type Code Symbol Stamp:

NJA Certiffcate of Au1horlzallon No.:

NlA Expiration Date:

NiA Signed:

~J

~

Asia O. Jelf<ins, Maintenance Bpt, Support Date:

f rf"'wner orOwners Designee, Title CERTIFICATE OF INSERVICE INSPECTION I, the und&rsigled, holding a valid commission Issued by the National Board of Boner and PressUID Vessellnspecton; and the State or Province of ~

and empIoYedby--t.;.&M::=-__--.;CJT'..:;....______________....

of

~

q hall8lnspected the components described in this Owne"sAeport~

6/30//1 to I~I

. and stata that 10 the best of my knowledge and belief. the Owner hiS P'ekSd examinatIonS and tak9f{~ measures desclibed In this Qwne(s Report ill accordance with the requirements altha ASME Code,Section XI.

By signing this cartillcate neither the Inspector nor his employer makes any warranty. elCPfGSSEld or Implied. concemlng the examlnsllons and corniCtlva measures described In this OWnec's Report. Furthennora. neither the Inspector nor his employer shall be liable in any manner for any personal Injury or property damage or 8 loss of any kind arising from or connected with this inspectlon.

Dm~ ____~~~~--____------__---

FORM NI5-2 OWNER'S REPORT FOR REPAJRlREPLACEMENT ACnVITY As Required b~ the Provisions of the ASME COde,Section XI.

1. Owner~

Southern Nuclear Operating Co.

Dale:

December 9, 2010 Hams 40 Invemess Centar Parkway; Birmingham, Al35242 of 2

Address

2. Plant JOseph M. Fai1ey Nuclear PlanI (FNP)

Unit.

FNP Unil1 Nam8 7388 North Stale Hwy 95; Columbia, Al36319 Work Order No.: P16* 1080942026 Address Repair/Replacement Organization PO No, Job No, etc,

3. WCfk Performed By:

FNP Maintenance Department.

Type Code Symbol SIalnp!

N1A Nams 7388 North Slate Hwy 95; Columbia, Al36319 Authorizalfon No.::

N1A AddfflSS NJA

4. ldentlficatton of System:

TPNS: Q1P16V216R* HCC~39 SW Return from 1C CTMT Cooler Drain (ASME Class 3) 5... (a) ApplIcable ConsIruCIion Code:

Section 11/

  • 1971 Edltloni' Winter 1971
Addenda, N/A Code Case

~

(b) Applicable Ecillon of Sectfon XI Used for Repair/Aapacement ActIvItr.

2001 Addenda:

2003 Year (c) ApplIcable Section XI Code Case(s}t:

NJA

$. IdenlillcatlOn of Components:

National Corrected.

ASMECode Name 01 Other Year Name of Component ManufactulW Serial No.

Board Removed. or Slalnped Manufacturer ldenllflcalion Built No.

Installed (Yes or No)

PIPE Mcjunkin L65S0S NlA 7047..0-62574 1973 Ramol/ed No VALVE KEROTEST GSI*9 N/A FNp*295 1975 Removed YES PIPE Sandvik 519775 NlA PO: QP090740 2009 Installed No VALVE BNl A070809*1*56 NlA PO: QP070775 2008 Installed YES 7; DeSCIfptioo of Wodc SW Valve and Pipe Replacement 8,. Tests Conducted:

HydroslaliC [J Pneumalic [J Nominal Operating Pressute li2I Exempt []

Pressure:* ____psi Tesl Temp.:~ _____ "1=

Other []

NOTE: Supplemental sheets In form of liSts, sketches; or drawings may be used. provided (1) size Is 8*.112 It\\; x 11 In** (2) informatIOn in Items 1 thl'OU\\1l6 on this report Is Included on each sheet. and (3) each sheet Is numbered and number of sheets is recorded al the top of this form.

FORM NIS.2 (Back)

9. RemlUks Reference MOC 10B0942001 for reconciliation of material diHerence

~~.D:at~iOlii.1iidiId -

"A*

Valve Code of contructlon and replacement valve cod& is ASME sec.. 1lI,_ 1971 edition, Wimer 1971 Addenda wI' _

para N8611'.1C of Winter 1972 Addenda, class 3 Replacement pipe Is ASME Sec. 1/ & III. Subsection ND. 1986 Edition no addenda. class 3 FNP Piping Specificallon SS110902 allows a construction Code of ASME Section III. 1971 Edition Ihru 2000 Edition Addenda VT*2 completed Sal.

Transaction #'1'1: 192950, 190020 CERTIFlCATE OF COMPLIANCE I certify that the statements made In the raport are correct and that this conforms to the requirements of the ASME Code. Sec1ion XI.

Type Code Symbol Stamp:

N/A Certificate of Authorization No.:

NiA Elq>iratlon Dale:

NlA Signed:

~ Z:

  • Asia O. Jerkins. Maintenance Spt, Support Date: --,;"-~-0-,-,,------t Own8r or Owner's Designee. Title CERTIFICATE OF INSERVICE INSPECTION I. the undersigned. holding a valid commission Issued by the National Board of Boller and Pressure Vessellnspactors and the Stale or Prov!nce of ~

and employed by...J.==-:..--==a-~__~__~_______~~-I of

~

4':

have lnspepted the components described in this Owners Report during lhe peri'

~/.a:Wf) 10

___ 1.};".'4/

.and state thalia the best of mv knOWledge and belief. the Owner~$rmed examloatlons and t!lktt'~ measures descl1bed In thiS Ownet"s Report In accordance with the requirements of the ASME Code.Section XI.

By signing this certificate neither the Inspector nor his employer makes any warranty. expressed Of implied, conoemIng the examinetlons and conectlve meesul'e$ deScribed In this Owner's Report. FurlhefmOl'8. neither the Inspeclor nor his employer shall be liable in any manner for any personal injury or property damage Of a foss of any kind arising from Of connected with this Inspection.

Dale: __-4~"';;'~WJ,-_____

FORMNIS-2 OWNER'S REPORT FOR REPAlRIREPLACEMENT ACTIVITY As Required by the Provisions of the AS~E Code,Section XI Southem Nuclear Operallng Co.

Date:

December 13, 2010 NturIt'I 40 Invemess Center Pamway; Birmingham, AL 35242 Sheet:

01 2

Address 2.* Plant*'

Joseph M.. farley Nuclear Plant (FNP)

Unit:

FNP Unit 1


~------M~~--~--~----------

7388 North Stale Hwy 95; Columbia, AL 38319 Work Order No.;~ P16* 1080942027 RepairlRepJaC9lTlfHlt Organization PO No, Job No, sir;.

3*. Work Performed By:

FNP Maintenance Departmen1 Type Code Symbol Stamp:

NlA Natn(J 7388 North State Hwy 95; Columbia, AL 36319 Authorization No.:

NlA Address Expiration Date:

NlA

4. Identification of System:

TPNS:!Q1Pl6V216S* HCC*29 SW Supply from 1G CTMT Cooler Drain (ASME Class 3)

5. (a) Applicable ConstnJcUon Code:

Section III

, 1971' Edition, Winter 1971 Addenda.

NlA Code Case


~

(b) Applicabl& EditIOn 01 Section XI Used for Aepalr/Replacement AclMty:

2001 Addenda:

2003

--~~~e8~r---

(c) Applicable Section XI Code Case(s)t N/A

6. Identification of Components.

National Corrected, ASMECode Name of Other Year Name of Componen1 Manufacturer Serial No.

Board Removed,or Stamped Manufacturer Identification Built No.

Inslalled (Yes or No)

PIPE TIOGA 285192 N/A QP-1674 1987 Removed No VALVE KEROTEST G51*10 NlA fNP*295 1975 Removed YES PIPE Sandvik 519775 N/A PO: QP090740 2009 Inslal/ed No VALVE 8NL A070809-1*19 NlA PO: QP070775 2008 Installed YES

7. Description of Worlc SW Valve and Pipe Replacement
8. Tests Cond.Ictedl Hydrostalla [J Pneumatic Cl Nominal Operatlng Pressure

&!I Exempt [J Othet[]

Test Temp..:

OF


psi NOTE: Supplemental sheets In form of lists, Sketches, or drawings may be used, provided (1) size Is 8-1/2 In. x 11 in., (2) information In items 1 through 6 on this report Is IhCIuded on each sheet, and (3) each sheet Is numbered and number of sheets Is IlICOfded at the top of this form*.

FORM NIS-2 (Back)

9. Ramruks Reference MOC 1080942001 for reconciliation of matenal difference

.~ X&iiUI.ICIiiI\\ilWIfjfPOl&I"bit~

Valve Codeotcontl1.lctlonandrepl~ment valv$code,is ASME sec. III. 1971 aditlon. winter 1971 Addenda wi para. NOO111.1C of Winter 1972 Addenda. class 3 Replacement pipe is ASME Sec. If & III, Subsection ND. 1986 Edition no addenda, class 3 FNP Piping Specification SS110902 allows a constl1.lction Code of ASME Section III. 1971 EdiUon thl1.l 2000 Edition Addenda.

VT*2 completed Sat.

Transaction #'s: 190027. 192951 CERTIFICATE OF COMPLIANCE I certify that the statements mads In the RIPOrt are correct and that this conforms to the requlrements 01 the ASME Code.Section XI.

Type Code Symbol Stamp:

N/A Certificate of Authorization No.:

N/A Expiration Dete; NlA Signed: 7."'7

\\

Asia O. Jerkins, Maintenance SP!. Support oate:,llJ/'II

--~~~---------1

~or Owners DeslgnI'J8, nUe

(

CERTIFICATE OF INSERVICE INSPECTION I, the underalgned, holding a valid commission issued by !he National Board of Boller and PItISSUr9 Vessellnspectora and the Slate or Province of ~N'..?-:

and emplOyedby_u:;;..u:::::;;-=ttf~*---------------1 01

~

cr have Inspected the components described In \\hls Owners Report during the &!riod

--if!/~/)

to....tk/a

.and slate that 10 1M best 01 my knowledge and bellet. the ~ri\\l4'p;tfOrmed examinations and t~rrectIve measures described In this Owner's Report In accordance with the requlrements 01 the ASME Code,Section XI.

By signing thls cer1lficate neither the Inspector nor his employer makes any warranty. expressed or Implied, concerning the examinations and conective measures described In this OWners Report. Furlhennore. neither the Inspector nor his employer shall be labia In any manner lor any peraonal injury or property damage or a loss 01 any kind arising from or connected will this inspection.

Signature Date: ----s.~¥-~---------

FORM NI5-2 OWNER'S REPORT FOR REPAIRIREPLACEMENT ACTIVITY

, As Required by lI\\e Provisions of !he ASME C~,Section XI

1. Owner:

Southern Nuclear Operating Co.

Dale:

December 9, 2010 NBmIJ 40 Inverness Canter Parkway; Birmingham, AL 35242 Sheet:

of Addf8SS 2., Plant Joseph M. Farley Nuclear Planl (FNP)

Unit FNP Unit 1


~----~Nam9~----------------

7388 North State Hwy 95; Columbia, AL 36319 Work Order No.:: P16* 1080942028 Addf8SS RepaJ~ Organization PO No,'JOb'NO,,ta.,

3. Work Performed By;:

FNP Malnlenance DepartlTlsnl Type Code Symbol Stamp:

NJA N81T/8 '

7388 North Stale Hwy 95; Columbia, AL 36319 NJA NJA

4. Identification of System:

TPNS: Q1P16V216T* HCC*39 SW Retum from 1C CTMT Cooler Drain (ASME Class 3) 5, (a) Applicable Construction Code:

Section III

, 1971 Edition, Winter 1971 Addenda.

N/A Code case


~

(b) Applicable Edillon of SectIon XI Used for RepaJrlRepla<:ement ActIviIy.

2001 Addenda; 2003

--~~~~~--

(c) Applicable Section XI COde Case(sr.

!IVA

6. Identification 01 Componen1S.i, National Correcled, ASMECode Nameo#,

OIhar Year Name of Component Manufacturer Serial No.

Board Removed, Of Stamped Manufactul'Gl' ldentiflcallon Built No.

InstaRed (Vas or No)

PIPE Mcjunkin L65803 N/A 7047-Q-62574 1973 Removed No VALVE KEROTEST OSI*11 N/A FNP*295 1974 Removed YES PIPE Sandvik 513912 NlA PO: QP080626 2007 Installed No VALVE BNL A070809-1*a NlA PO: QP070775 2007 Installed YES

7. Description of Work:

SW Valve and PIPe Replacement 8., Tests Conducted:

Hydrosta\\k: [J Pneumatic [J Nominal Operatfng Pf$S5ure li2I Exempl [J Other[J


psi NOTE: Supplemental sheets In form of lists, sketches, or drawIngS may be used. provided (1) size Is 8-1/210..)( 11 In., (2) Information in ilems 1thl'ClU{tl6 OIl this report Is Included on each sheel. and (3) each Sheetls numbered and numbel of Sheets is recorded at the top of this form.

FORM NIS*2 (Back) 9.* Rem8lks Reference MDC 1080942001 for reconclllation of material difference APPL/Ili ~rw; fWi&& III &r 1lIIiidIOd*

Valve Code of cootructlon andreptacament valve code is ASME sec. III, 1971 edition, Winter 1971 Addenda wI para. N8611101 Cof Winter 1972 Addenda, class 3 Replacement pipe is ASME Sec. II & III, Subsection ND, 1986 Edition no addenda, class 3 FNP Piping Speciflcatlon SS110902 allows a construction COde of ASME Section III, 1971 Edition thru 2000 Edition Addenda vr*2 completed Sat..

Transaction /#'s: 190169 CERTIFICATE OF COMPliANCE I certify that the statements made in the report are correct and that this conf0lTTl8 to the requirements of the ASME Code,Section XI.

Type Code Symbol Stamp:

NlA Certificate of Authorizatlon No.:

N/A Expiration Date:

NJA Signed:

A I

Date: ----------t Asia O. Jerkins, Maintenance Spt, Support (Mnfjr Of Owner's D8s1gnee, Title CERTIFICATE OF INSEAVICE INSPECTION Stale or Province of of have Inspected the components described In this Owner's Report wring Ihe period

'3, (J

10 ~~

,andslate that to the best of my knowledge and belief, the has rformed examinations and t co measures dascribed In thiS Owner's Report In accordance wflh the requirements oIlhe ASME Code,Section XI.

By Signing this certifioate neither the Inspector nor his employer makes any warranty. expressed Of implied. coneemlng the examinations and corrective measures described In this Owner's Report. Furthormore. neither the Inspector nor his empfoyer shall be liable In any manner for any personal injulY or property damage Of a toss of any kind arising from or connected Viith this inspection.

Dale:


~~~~---------------

FORM NI5-2 OWNER'S REPORT FOR REPAlRlREPLACEMENT ACTIVITY As A,UIre<lby the Provlstons 0/ the ASME Code,Section XI

1. Own8f~

Southem Nuclear Operallng Co.

Date::

Deeemoor 9. 2010 Nsme 40.101/91005$ Center ParkWay; Blrmingham.AL 35242.

Sheet of 2

Address 2*. Plant Joseph M. Farley Nuclear Plant (FNP):

Unit FNP Un1t 1


~Na~me------~---------

7388 North State H\\'j)' 95; C<lJumbla. AL 36319 Work Order No;i P16*1000942029 AddrtJ" RepaltlRe~t Orgahlzatlon PO No, JOb No, 6ta~

3. Work Performed By:

FNP Maintenance Department Type Code Symbol Slamp; NJA Name 7388 North Slate H\\'j)' 95; Columbia. AL 36319 Authorization No",

NtA Address Expiration Da1~

NlA

4. IdeI11flicalioo of System:>

TPNS: Q1P16V218U - HCC.29 SW Supply to lC CTMT Cooler Drain (ASME Class 3)

5. (a) Applicable Construction Code~

Section III

  • 1971 Edition. Winter 1971 Addenda; NJA Code Case

~

(b) AppliCable EdtIOn 01 Section XI Used for Repair/Replacement ActMty; 2001 Addenda:.

2003

--~Yi~M-r---

(c) Applicable section XI Code Case(s)l N/A

6. ldentilicaHOn of Components:

National Corrected.

ASMECode Name of Other Year Name of Component Manufacturer SEKial No.

Board Removed,or Stamped Manufacturer Identification Built No.

Installed (VesorNo)

PIPE Mcjunkin L65S0S NlA 7047.0-62574 1973 Remol/ed No PIPE TIOGA 285192 NlA QP*1674 1987 Removed No ELBOW HUB R95R N/A QP2030 1987 Removed No VALVE KEROTEST OSI-12 NJA FNP-295 1975 Removed YES PIPE SANDVIK 513912 N/A QP000626 2007 INSTALLED No ELBOW Bonney Forge 44012 NlA QP090059 2006 INSTALLED No VALVE BNl A070809-1*3 NlA QP070nS 2007 INSTALLED YES

7. DeS¢ptlon of Work:

sw Valve and Pipe Replacement 8, Tests CondtJcted:

Hydrostatfc []

Pneumatlq: []

Nominal Operating Pressure ra Exempt []

_____Psi Other[]

Pressure:

Test Temp.}':

Of NOTE: St4Jl)lementalsheets In form of USIS, sketches. 01 drawings may be used. provided (1) stZEI is a.ll2ln~x 11 in., (2) Information In Items 1 through 6 on this report Is included on each sheet. and (3) each sheef [s numbered and number 01 sheets Is recorded at 1he top of this form.

i

FORM NIS-2 (Back)

9. Rem!Uks Reference Moe 1080942001 lor reconciliation of material difference JWlIfiJ.lI&i ilili~ D.i& IfdI'J&& &i & oitic:lMa Valve Code of contruction and replacament valve code is ASME sec. III. 1971 edilion. Winter 1971 Addenda wi pam. NB6111.1C of Winter 1972 Addenda. class 3 Replacement plpe is ASME Sec. II & III. Subsection ND. 1986 Edition no addenda. class 3 Replacement Elbow is ASME Sec. II & III. Subsection ND. 1986 EdItion 110 addenda, class 3 FNP PIping Specification Ssll0902a1lows a construction Code of ASME Section III. 1971 Edition thru 2000 Edition Addenda VT*2 completed Sal.

Transaction Ifs: 190225 CERTIFICATE OF COMPUANCE I certify that the statements made In the report are correct and that this conforms to tha requirements of the ASME Code.Section XI.

~or Owner's DesIgnee. Titls Type Code Symbol Stamp:

NlA Certificate of Authorization NJ?

N/A Expirallon Date:

NlA Signed:.

~ ~

Asia O. Jerkins. Maintenance SpIt Support Date:

,,"'------1

__I:.J'~~'8,~~[..'

f CERTIFICATE OF INSERVICEINSPECTION I. tha undersigned. hokfll1g a valid commission Issued by the NatIonal Board 01 Boiler and Pressure Vessel Inspectors and the State or Province of

~k: and employed bV_u:::.~~_....;cr:::L..--:-____________-I 0'

~ if have inspected the components described In this Owner's RePOft{fUrlnQttlpZiod u~d()

10 J//~

,and state that to the best of mv knowledge and belief. the Owner r(as petlormed 8)(8fJ1inalions and tak~~ective measures described In thIS Owner's Report In accordenCe With the requirements of the ASME Code. Sectton XI.

BV signing this certlfk:ate neither the Inspector nor his employer makes any warranty. expressed or Implied, concerning the examinations and corrective measures described In \\hIs Owner's Report. Furthennore, neither the Inspector nor his employer shall be liable In any mSMer for any persona/Injury or property damage or a loss of any kind arising from or connected with this inspection.

Commissions: ~?..-7 A_ /' ~ ~ 4::f:1/J

~Slgnaturs NationBJ Board. State. Province, and EndorsemtiInts Date:

11t,tt I

FORM NIS-2 OWNER'S REPORT FOR REPAIR/REPLACEMENT ACTIVITY As Required by the Provisions of the ASME Code, Seclion XI

1. Owner:

Southem Nuclear Operatmg Co.

Dale:

December 9. 2010 Name 2

40.lIverness Callier Parkway; Birmingham. AL 35242 Shee!:

of Address

2. Plant:

Joseph M Farley Nuclear Plant (FNP)

Uni!:

FNP Unit 1 Name 7388 North Slale Hwy 95; Columbia. AL 36319 Work Order No.:

P16* 1080942030 Address RepalrlRepJacement Organization PO No, Job No, eto.

3. Work Performed By:

FNP Maintenance Depa,rtmenl Type Code Symbol Stamp:

NIA Name 7388 North State Hwy 95: Columbia. AL 36319 Aulhorizatlon No.:

NJA Address Expiration Dale:

N/A

4. Identification of System:

TPNS. Q1P16V216V* HCG-39 SW Supply 10 lC CTMT Cool", Drain (ASME Class 3)

5. (a) Applicable Construction Code:

Section II!

, 1971 Edition. Winler 1971 Addenda.

N/A Code Case


y;:-

(b) Applicable Edition of Section XI Used for Repair/Replacement Activity:

2001 Addenda:

2003 Year (c) Applicable Secllon XI Coda Case(s):

NlA

6. Identification of Components:

National Correcled, ASMECode Name of Other Year Name of Componenl Manufaclurer Serial No.

Board Removed, or Stamped MMufacturer IdenHflcation Built No.

Installed (Yes or No)

PIPE McJunkin L6580a NIA 7047*0-62574 1973 Removed No ELBOW unknown unknown IJnk unknown unk

\\mknown unk VALVE KEROTEST CS4-3 NIA FNP*295 1975 Removed YES Sockolst unknown P1e HBC -39 N/A unknown unk unknown unk Cap unknown PiS HBC* 39 N!A unknown unk unknown unk PIPE SANDVIK 513912 NfA QP080626 2007 INSTALLED No ELBOW Bonney Forge 44012 NlA QP090059 2006 INSTAllED No VALVE BNL A070B09*1 -15 WA QP070nS 2007 INSTALLED YES Sockolet WFI 4949ANB NiA QP101 074 2010 INSTALLED No Cap TFA 1118BD-9 NlA QP090606 2009 INSTALLED No

7. Description of Work:

SW Valve and Pipe Replacemenl

8. Tests CondUcted:

Hydrostallc 0 Pneumatic CJ Nominal Operating Pressure Ii!I Exempt 0 Other CJ Pressure:

psi Test Temp.: _____ oF NOTE: Supplemental sheets In form of Ilsls, sketches, or drawings may be used. provided (1) size is 8-1/2 In. )( 11 in** (2) Information in items 1 through 6 on thls report h. included on each sheet, and (3) each sheet is numbered and number of sheets is recorded al the top of this form.

FORM NIS-2 (Back)

9. Remai1<s Reference MOC 1080942001 for reconciliation 01 malerial difference Appkabis Miinu/UGfuIO?S 'tiala Reports fl) bii BIt/lClieo Valve Code of contftlclion and ree'acemenl valve code is ASME sec III 1971 edition. winter 1971 Addenda wI para. NB6111.1C of Winter 1972 Addenda, class 3 Replacement pipe is ASME Sec. II & III. SubSection ND, 1986 Edition no addenda, class:1 Replacemenl Elb¢w is ASME Sac, II & III. Subsecllon ND, 1983 Edition no addenda. class 3 Replacement Pipe Cap and Seekolst IS ASME sec 1/ & III Sub NC 1998 EdItion. no Addenda class;2; and 1998 Ed. TI1[U 2000 Ad.

FNP Piping Specification SS 110902 allows a construction Code or ASME SecflOnlll, 1971 Edition thrll 2000 Edition Addenda Transaction /I's: 1901157, 198618, VT*2 completed Sat.

CERTifiCATE OF COMPLIANCE I cenify tl1allhe statements made in the report are correcl and that this conforms to the requirements ollhe ASME Code,Section XI.

Type Code Symbol Stamp:

NiA Certificate 01 Authorization No.:

NiA Expiration Dale:

NfA Signed:

~-']

Asia O. Jerkins, Maintenance Spl. Suppon Dale: --,../.t-a-0-,-II-----I

~er or Owner's Designee, TIlle CERTIFICATE OF INSERVICE INSPECTION I. the undersigned. halding a valid commission Issued by the Nallonal Board of BoHer and Pressure Vessel Inspectors and the Slale or Province 01 ~.f= and employed bY_"-!l;~:::.-_=~--:-_~-_~:__---_ _:_:__:__:____:__I of 1tdt'l.!'lb1llJ c.r have Inspected Ihe components described in Ihis Owner's Report during the ~riod

' (,!Jc,,/0 10 Il.ie!Ll

' and stale that 10 the besl of my knowledge and belief, Ihe Owna has alformed examinaUons and taken lorractlva measures described In this Owner's Report In accordance with Ihe requirements of the ASME Code,Section XI.

By signing this certificale neilher the Inspeclor nor his employer makes any warranly, expressed or implied, concemlng the examinations and corrective measures dasorlbed in this Owner's Report Furthermore, neither Ihe Inspector nor hIs employer shall be liable in any manner tor any pel'1lonal injury or property damage ()( a Joss of any kind arising from or connected with Ihis Inspection.

Inspector's Signature Dale:

FORM'N/S-2 OWNER'S REPORT FOR REPAlRlREPLACEMENT ACTIVITY A~ Required ex the Provisions oitneASME Code, Sectlon XI (d

1, Owner:

.Southam NU<<::tear Operatlng Co.

Date~

December 9, 2010 Nams 40 Invemess Center ParKway; Birmingham. AL 35242 Sheet:

of 2


~

Addtrilss 2: Plant Joseph M. Farley Nuclear Plant (FNP)

Unit FNP Unit 1 Name 7388 North State Hwy 95; Columbia.AL 36319 Work Order No.;

P1S* 1080942031 AddtrilSs RapaifiRepJ8cement OrganiiatfM PO No, Job No, 8/0.

3, WOlle Performed By:

FNP Maintenance Department Type COde Symbol Stamp-:

NlA Name 7388 North State Hwy 95; Columbiai.AL 36319 Authorizatfon No.:

NlA

. Addta8S Expiration Date:

NlA 4, Identification 01 System~;

TPNS: Q1P16V216W* HCC"29 SW Retum from lC CTMT Cooler Drain (ASME Class 3) 5; (a) Applicable Construcllon Code=

Section III

, 1971 Edlnon, Winter 1971 Addenda.;

NiA Code Case


y;:-

(b) Appr&(;able EcHtion of Section XI Used lor Repair/Replacement ActMtyt; 2001 2003 Ysar (c) Applicable Section Xl Code Case{s),

NlA

6. IdentificatiOn 01 ComponentSI' National Corrected, ASMECode Name of Other Year Name of Component Manufacturer Senal No.

Boald Removed. Of Stamped Manufacturer ldenliflcallon Built No.

Installed (Yes or No)

PIPE McJunkin L65803 NlA 7047*Q-62574 1973 Removed No VALVE KEROTEST CS44 N/A FNP*295 1974 Removed YES PIPE Sandvik 519775 N/A PO: QP090740 2009 Installed No VALVE BNl A070s09-1-6 NlA PO: QP07077S 2007 Installed YES 7*. Description of walk:

8*. Tesl$ Conducted:

HydtOstallc

[]

Pneumallc []

sw Valve and Pipe Replacement Nominal Operating Pressure Ii!I Exempt []

Olher []

Pressure:"

psi Test Temp.:,

OF NOTE: Supplemental &heelS In form of lists,..sketclles. 01' dra¥lings may be used, provided (1) size Is 8-112 Iru x 11 In., (2) Information In items 1 through 6 on this report is Included on each sheet, and (3) eBCil sheet is numbered and number 01 sheets isreconSed at Itte top ot thiS form..

FORM NIS-2 (Back)

9. Remarks Reference MOC 1080942001 for ra<Xlnciliatlon of malerial difference JWIlbiliIif.~" nap;;;:; fa & &ciiOid Valve Code 0.1 contructi(m and r2Placemenl valve code Is ASME sac. 111,1971 editIon. winter 1971 Addenda wi para NB6111.1C of Winter 1972 Addenda, class 3 Replacement pipe is ASME Sac. II & III. Sub$ec1lon NO, 1986 Edition no addenda.. class 3 FNP Piping Specification 88110902 allows a construction Code of ASME Section III. 1971 Edition thru 2000 Edition Addenda VT*2 completed Sal..

Transaction #'5: 190023 CERTIFICATE OF COMPLIANCE I certlfy that H1& statements made in the report are correct and that this conforms to the requirements of the ASME Code.Section XI.

Type Code Symbol Stamp:

NtA Certificate of Authorization No.:

NJA Expfration Date:

NIA

~7" AsiaO. Jerkins, Maintenance Spt, Support Date: --IIc-~-'~-II--------I SIgned:

"'OWner orOWners Designee. Title

--r:

/7-,.:.!-------I CERTIFICATE OF INSERVICE INSPECTION I, the undersigned. holdng a valid commiSSion issued by tha National Board 01 Boller and PressUIliI Vessel Inspectors and the State or Province of ~

and employed by-.t:.t:::al~__er='______________-I of

~, cr have Inspected the components descrlled In lhIs Owner's Report during the peri6d

¥-~iJ to

<<i.!J?h

'and state that to the best of my knowledge and belief, the Qwnerha$fformed examinations and !ak.fk~ractlve measures dElSCflbed in this Owners Report In accordance with the It!lqulramenls of the ASME COOe.Section XI.

By signing this certlficete neIthEIr the Inspector nor his emplOyer makes any warranty. expressed or implied. conceming the examinations and corrective measullils described In this Owner's RepoI1. Furthermore. neither the Inspector nor his employer shall be Hable In any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

Commissions:

U.

NstfonBJ Bostd. State. Province. an(} Endofssments O~~ _______~~~~----__--------

fORM NI8-2 OWNER'S REPORT fOR REPAIR/REPLACEMENT ACTIVITY As Required by Ihe Provisions of 1M ASME Code. Stlcllon XI 1., OWner.

Southem Nuclear. Operating Co.

December 13, 2010 Name 40 Invemess Cenler ParkwaYiBirmingham, AL 35242 Sheet!

1 of 2

Addrass

2. Plant Joseph MJanell Nuclew Plant (FNP)

FNP Unit 1


~-----*~Ms~me~~~~--------

7388 North Slate Hwy 95; Columbia; AL 36319 Work Order NO',:: P16* 1080942032 Address RepslriRepll1CSment Organization PO No, Job NO,. etc.

l; Work Peffimned By::

. FNP Maintenance Department Type Code Symbol Siamp:

NfA Namfl 7388 North State Hwy 95: Columbia, AL 36319 Authorization No;:

NiA Address' Expiration DaI9~

NlA 4, ldentllk;atlOn of System!

TPNS:.Q1P16V216X ~ HCC*39 SW Retum from 1C CTMT Cooler Drain (ASME Class 3) 50 (a) ~ Construction Code.

Section III

'. 1971' EdlIlon.

Winter 1971 Addenda.

NlA

.Code 0ase


y;;;,.-

(b) Apprrcable Edliion of Section XI Used for Repalr/Aeplacement Aclivi1y::

2001 Addenda:

2003 Year (c) Applicable Section XI COde C8se(s)::

NfA 6;, ldiilntiflcalion of Components!.

Name 01 ComponElflt Name 01 ManufaClUl'8f Manufacturer Serial No.

NaUonai aoaro No.

Other IdentiflcaUon Year Built Corrected.

Removed,or Installed ASMECode Stamped (Yes or No)

PIPE McJunkin l65803 N/A 7047.0-62674 1973 Removed No VALVE KEROTEST CS4*S N/A FNp*295 1975 Removed YES PIPE Sandvik 513912 NiA PO; QP080626 2007 Installed No VALVE 8NL A070809-1-41 NlA PO: QP070775 2008 Installed YES 7, Description of Wooc SW Valve and Pipe Replacement

8. Tests Conducted<

HydrostatiC [J Pneumalk: [J Nominal Operating Pressure Ii1!I E)(EIII1pt IJ Othet' [J Pressure:

_______psl Test Temp;:

"F NOTE: Supplemental sheets In form 0/ lists. skelch6s. or drawings may be used. prOlilded (1) sIZe is 8*112 in, x11 in.* (2) information in items 1 thl'OlJ{tl6 on this report is Included on each sheet. and (3) each sheet Is numbered and number of sheets is recordad althe lop of this form.

FORM NIS.2 (Sack)

9. Aem8Iks Reference MDC 1080942001 IOf reconciliation of material difference

~~,"§iIOii'IIOS:; aa&a ValliE/Code of conlN,etlon and replacement vallie code Is ASME sec. III, 1971 edition, winter 1971 Addenda wI para NB6111.1C of Winter 1972 Addenda, class 3 Replacement pipe is ASME Sec. II & In. Subsection ND. 1980 Edlllon no addenda. class 3 FNP Piping Speciftcation SS 110902 allows a construction Code of ASME Secllon III. 1971 Edition thru 2000 Edition Addenda VT*2 completed Sal.

Transaction ii's: 190074 CERTIFICATE OF COMPLIANCE I certify Ihat the statements made In the report are correct and that this conforms to the requlremen19 of the ASME Code, SectIon Xl.

Type Code Symbol Stamp:

N/A Cartlflcate of Authorization No.:

NJA Elq)/ratlon Dale:

NlA

~ 7 Asia O. Jerkins. Maintenance Spt. Support h-,-';;-I-~-;"-'---I Date: --,-,

Signed:

"'-trwner or Owner's Desfgnee, TItle

-....:rr...:-:r:..:..----....

CERTIFICATE OF INSERV1Ce INSPECTION I. the undersigned, hoIdlng a valid commission Issued by the National Board of Baler and Pressure Vessel Inspectors and the Stale or Province of ~

and employedby..J.lt.::a.c..'-:.::'"'--______~---~---__f 01

~ ~ cr-have Inspected lhe components described In this Owner's A~period

~.;

to

!/.::1+h/

'and slate that to the basI 01 my knowledge and belli'll. the Owner iii§performed examinations and tak;;t;;;;:~e measures described In this Owner's Report In accordance with the requirements of the ASME Code,Section XI.

By signing thle cerlilicate neither the Inspector nor his employer makes any warranty. eJq::lRlSSSd or Implied. conceming the examinations and cormctive measUI8$ described in !his OMlar's Report. FUr1hermore. neither the Inspector JlOI' his employer sh8JI be liable in any manner lor any personal injury or property damage or a loss of any kind aJlslng from or COI'IIIGCted with this inspection.

Date:


~~~-----------------

FORM NIS*2 OWNER'S REPORT FOR REPAIR/REPLACEMENT ACTIVITY As Required by the Provisions of the ASME Code. SectionXI

=

1. Owner:

SOuthem Nuclear Operating Co.

Date:

December 13. 2010 Name 40 InvemessCenter Parkway; Birmingham, AL 35242 Sheet of 2

Addillss '

2*.. Plant Joseph M. Farley Nuclear Plant (FNP)

FNP Unit 1 NFinre 7388 No~h State Hwy 95; Columbia, AL 36319 Wolk Order No:,* P16* 1000942033 Address Repair/Replacement Organization PO No. Job No, etc"

3. Worl< Performed By:

FNP Malntenanca Department Type Coda Symbol Stamp!.

!lirA.

. NS1T16 7388 North State Hwy 95; Columbia. AL 36319 N/A.

AckIrBss EJ<plratfon Date:

NlA 4., IdenOOcatlon of Systeml" TPNS: Q1P16V21SA* HCC*29 SW Supply from 10 CTMT Cooler Drain (ASME Class 3) 5., (a) Applicable Construction Code:'

Section III

, 1971 Edtlon. Winter 1971 Addenda.

NlA Coda Case

~

(b) ApplIcable Edition of SectIon XI Used fOl' Repair/Replacement ActMty; 2001 2003 Yesr (0) Appl~ Section XI Code case(s);

N/A

6. ldentillcation of CompollElfltS!

Name of Component Name of Manufacturer Manufacturer Serial No.

National BoaJtI No.

Other ldentllloatlon Vear BuIlt Corrected.

Removed. 01' Installed ASMECoda Stamped (YesOl'No)

PIPE TIOGA 285192 N/A OP-1674 1987 Removed No PIPE' McJunkin L65803 N/A 7047..Q.62574 1973 Removed No ELBOW HUB R9SR NlA QP-2030 1987 Removed No VALVE KEROTEST DX1D-24 NfA FNP-295 1975 Removed YES PIPE Sandvik 513912 NlA PO: OPOB0626 2007 Installed No ELBOW BONNEY FORGE 44012 N/A PO: OP1091051 2006 Installed No VALVE BNl A070809-1-45 NJA PO: QP070nS 2008 Installed YES

7. Description of Walk:

SW Valve and PIpe Aeplaooment

8. Tests Conducted:

Hyc/roslalk: IJ Pneumatic [J Exempt [J Other[J Pressure:

Test Temp.: _____ OF


psi NOTE: Supplemental sheets In form of lists, sketdleS, or drawings maybe used, provided (1) size Is 8-112 In. x 11 in~ (2) information in Items 1 through 6 01'1 thIs report Is Included on each sheet; and (3) each sheet is numbered and number of sheetS Is recorded at the top ot this form.

FORM NI8-2 (Back)

9. Rem8lks Reference MOC 1080942001 fot reconclllaliOl'l of malerial difference
ypi&Qf Wii01iiCtiIImbiiil ~ 10 &i;ga;;a Valve Code of conlruellon and '
2Placement valve code Is ASME sec. 111, 1971 edition, winter 1971 Addenda wI '

para NB6111.1 C of Winter 1972 Addenda, class 3 Replacement pipe Is A5ME Sec. II & III, Subsection NO, 1986 Edltion no addenda, class 3 FNP Piping Speclflcatlon 55110902 allows a conslructlOl'l Code of ASME Section III, 1971 Edition thru 2000 Edition Addenda Vf-2 completed Sat, Transaction #'s: 190071 CERTIFICATE OF COMPLIANCE I certify that the statements made In the report are correct and that this conforms to the requirements of th8 ASME Code, 59C1fon XI.

Type Code Symbol Stamp:

NlA Certificate of Authorizallon No.:

N/A Elq]iration Dale:

N/A Signed:

~"7 Asia O. Jerkins, Maintenance Spl. Support Oal&: --,/-~I,!t-t,(-----I

-~r or Owoots Designee, Tltm CERTIFICATE OF INSERVICE INSPECTION I, the undersigned. holding a valk! commission Issued by the Na:IIonal Board of Boller and Pressure Vessel Inspectors and \\he Sialeor Province of ~

and empIoyedbY--"~-=-__=-_______________--I of

~.

q:

have inspected the components described In thts Owners Report during the Pined U$.k 0

-LiM/lI to

.and state that to the best 01 my knowtedge and belief. the OWner !lGp;;;j%;rmed examinations and takenlEO~measures described in this Owner's Report In accordance with the requirements of the ASME Code.Section XI.

By signIng this cel1iflcate neither the Inspector nor his employer makes any warranty. 8XpfEISSed or Implied, concemlng the examinatiOM and conectJve measures described In this Owner's Report. Furti'Kllmore. nelther Ihe Inspector nor his employer shall be liable,In any manner for any personal injury or property damage or a loss of any Idnd arlsIng from or connected with thl8lnspection.

Oal&: ______~~~~__-------------

FOAM NI5-2 OWNER'S REPORT FOR REPAIR/REPLACEMENT ACTIVrrv As Rl3Qulred by the Provisions of the ASME Code,Section XI Southern Nudear Operating Co.

Dale::

December 9, 2010 Name 40 Inverness Center Parkway; Birmingham, AL 35242 Sheet:

of 2

AddrBss

2. Plant, Joseph M. Farley Nuclear Planl (FNP)

Unit FNP Unit 1


~N~a-me------~--~------

7388 North State Hwy 95;'Columbia.AL 36319 Work Order No;:

P16* 1080942034 Address R8(1aif/RfJpfaci1ment Organization PO No, Job No, BIr:,

3, Work Performed By; FNP Maintenance Department Type Code Symbol Stamp:

NlA Nams 7388 North State Hwy 95; Columbia. AL 36319 Authorization No,,~

NlA Addf8SS Expiration Date; NlA

4. Identification of System:

TPNS:Q1P16V218B* HCC*39 SW Return from 10 CTMTCooler Drain (ASME Class 3)

5. (a) Applicable Cons1ruCtion Code~

Section III

, 1971 Edition.

Winter 1971 Addenda.

NlA Code Case

~

(b) Applicable Ecition of SectIon XI Used for Repair/Replacement Actlvlty:i 2001 Addenda:

2003

---"~~oo~,---

(c) Applicable Section Xl CodeCase(s);~

N/A

6. Identification of Components:

Name of Component Namedf Manufacturer Manufacturer Serial No, National Board No.

Other ldentiflcallon Year Built Corrected.

Removed. or Installed ASME C<xle S1amped (yes or No)

PIPE McJunkin L65S03 N/A 7047-0-62574 1973 Removed No VALVE KEROTEST DX12-14 N/A FNp*295 1975 Removed YES PIPE Sandvik 513912 N/A PO: QPOS0626 2007 Installed No VALVE 8NL A070809-1*79 N/A PO: QP070775 2008 Installed YES

7. Description of Work:

SW Valve and PTpe Replacement

8. Tests Conducted:

Hydrostatic 0 Pneumatic 0 Nominal Operatlng Pressure eJ Exempt 0 OtherC]

Test Temp;:

OF


pst NOTE: Supplemental sheets in form of Hsts. sketches, ot drawings may be used.. provided (1) size is 8-112 Ill; x 11 in., (2) information in items 1 through 6 on lhls report is included on each sheet. and (3) each sheet Is numbered and number of sheets is recorded at the lop of this form;.

FORM NIS-2 (Back)

9. Rematks Reference MDC 1080942001 for reconclUat1on of material diHemnoo

". AiiiEtbiltMdiCtufi?*&aAlPdiOSlfa:cJ.,:.-.---,

Valve Code of contruction and replacement valve co is ASME sac. 1'1. 1971 oortlon, winter 1971 Addenda wi para. NBa111.1C of Winter 1972 Addenda. class 3 Replacement pipe Is ASME Sec. /I & Ill, Subsecllon NO, 1986 Edition no addenda, claSs 3 FNP PipIng Specification SS110902 allows a conslructlon Code of ASME Section III.,1971 Edition Ihru 2000 Edition Addenda VT*2 compleled Sat.

Transaction #'s: 190178 CERTIFICATE OF COMPLIANCE I certify that the slatements made In the report are correct and that this conforms to lhe requirements of the ASME Code,Section XI.

Type Coda Symbol Stamp:

N/A Certificale of Aulhorlzatlon No.:

N/A Expiration Date:

NlA Signed:

~:z.'

Asia O. Jerkins, Maintenance Spl, Support Date: _""/'~~"::~I-~h.u...____--I Owner or Owner's Designee, TIlle CERTIFICATE OF INSERVICE INSPECTION I. the undersigned. holding a valid commission issued by the NatIonal Board of Boller and Pressure Vessel Inspectors and the Slate or Province of 6!t>4Itf-and employed bY-l.c::.=-_-=:z....___________~~~-..

of have inspected the components described In this Owner's Report during the pe to

~~I

' and state !hat to lhe best of my knowledge and belief, \\he Owner h ed examinations and tak~ measures described In this Owner's Report In eccon:1ance with \\he requirements of the ASME COde.Section XI.

By signing this certiftcate neither \\he Inspector nor his employer makes any wananty, 0!Cpressad or implied. concerning \\he examinations and c:orrective measures described in this Owner's RepoJt. Furthermore, neither the Inspector nor his employer shall be liable In any manner for any personal Injury or propefIy damage Of a loss 01 any kind arising from or connected with this Inspection.

Inspector's Signature Date: ___~c;.or::;;~L..--------

fORM NI&-2 OWNER'S REPORT FOR REPAIR/REPLACEMENT ACTIVITY As Required by the Pro\\/islons oltha ASME COde, SacHon XI L Owner..

Southern Nuclear Operating Co.:

December 9, 2010 N8JM 40 Inverness Center Parkway; Birmingham; AL 35242 Shee\\;.

t of 2

2. Plant Joseph M. Farley Nuclear Plant (FNP)

Unit:

FNP Unit 1


~------~N~8JM~----~~~----~

7388 North Slate Hwy 95; Columbia. AL 36319 Work Order No.: Pt6 - 1080942035 Address Repair/Replacement 6rgantzali00 PO No. Job No, 9~.

3. Work Performed By:;

FNP Maintenance Department Type Code Symbol Stamp:

NfA..

Name 7388 North*Stele Hwy 95; Columbia. AL 36319 Aulhorizatlon No.:

NJA Address Expiration Date:

NJA 4, ldenttileatioo of System~,

TPNS: Q1P16V218C - HCC-29 SWRelum from 10 CTMTCoolerDrain (ASME Class 3) 5, (a) Applicable Construction Code:

Section HI

  • 1971 Edition.

Winter 1971 Addenda.

N/A Code Case

~

(b) Applicable Edition 01 SectIon Xl Used for RepalrJReplacement ActMty:

2001 Addenda:-

2003 Year (e) AppIlcabIe Section Xl Code Case(s):

NJA

6. ldentiflcallon of ComponentS:.

Nallonal Corrected, ASMECode Name of Other Year Name of Component Manufaclurer Serial No.

Board Removed. or Stamped Manufacturer ldenliflcatlon Built No.

Installed (Yes or No)

PIPE Mcjunkin L65803 N/A 7047-0-62574 1973 Removed No VALVE KEROTEST J07*1 N/A FNP*295 1975 Removed YES PIPE Sandvik 519775 N/A PO: OP09074Q 2009 Installed No VALVE BNl A070009-1*1 S NlA PO: QP070775 2007 Installed YES

7. Description of Wooo, SW Valve and PIpe Replacement B._ Tasts Conducted:

Hydrostatic 0 Pneumatic 0 Nominal Operatll'l!J Pressure e

&Bmpt 0 OIherD Test Temp.:


psi OF NOTE: Supplemetllal sheets In loon oIlist~ sketd'teS,or drawings may be used. pro1Ilded (1) size Is B-112 In. x 11:

in.* (2) Informatlon In Items 11hrou(116 on this report is Incluc:fe<f on eaCh Sheet. and (3) each sheet Is numbered and numbat' 01 SheetS Is recorded at the top of !his loon.

FORM NI$-2 (Back) 9, Remarks Reference MDC 1080942001 for reconcillallon of material difference

w&tiiIJii/!UIJiCiiJIiibiI. R!IiiiI1i /(> &; IiiitidiIia Valve COde of contructlon and replacement valve code is ASME sec. IIi. 1971 edition. winter 1971 Addenda wI.

pam. NB6111.1C 01 Wlnler 1972 Addenda, class 3 Replacement pipe is ASME Sac. II &. 1If. SubsectionND, 1986 Edition no addenda. class 3 FNP Piping SpecIfication SS 11 0902 allows a construction Code of ASME Section III, 1971 Edition tllru 2000 Edition Addenda VT-2 completed Sat.

Transaction #'s: 190025, CERTIFICATE OF COMPLIANCE I certify that tha etatements made In the report are col'l'BCt and lhat this conforms 10 the requirements of the ASME Code.Section XI.

Type Code Symbol Stamp:

N/A Certificate of Authorization No.:

N/A Exphatlon Date: ____;.;;NI..:.;A:-__-I Signed:

It Asia O. Jerkins, Maintenance Spt, Support Date:

7.?

I hit/

(Owrfsr or Ownsr's Designee. Title

....::,.p;:,"I-!-.f------I CERTIFICATE OF INSERVICE INSPECTION State or Province of of have Inspected the components described In this Qwne(s Report during the period

/a 0 0

to

~

  • and slate that to the best of my knowledge and belief, the Owner rtarmed examinations and taken C6r

~&a8Ures descfibed in this owner's Report In accort\\ance with the requirements of the ASME Code. SecIlon XI.

By slgnlng this certificate neither the Inspector nor his employer makes any warranty. expressed or Implied. concemlng the examinations and corrective measures described In this Owner's Report. Furthermore. neither the Inspector nor his employer shall be liable In any manner tor any pen;onallnfury or property damage 01' a loss of any kind arising from or connected with thia inspection.

Commissions:

AJ NalionsJ Board, State. Province, and Endc
m;ements Oa~:
(~

FORM NI9-2 OWNER'S REPORT FOR REPAIR/REPLACEMENT ACTIVITY As Requirad Wthe Provisions of the ASME Code. Section Xl 1, Owner:

Southem Nuclear Operatlng Co; Date:

December 9, 2010 Name 40 Invemess Canter Parkwa~Blrmingham, AL 35242 Sheet:

of 2

Address*

2, Plant Joseph M; Farley Nuclear Plant (FNP)

Unit:


~------~N~8me------~------~~

7300 North Stale Hwy 95; Columbia, AL 363.19 Work Order No.:. P1a* 1080942036 Address*

RepairlReplacmnent Organization PO No, Jab No.. erc.

3., Work Performed B¢ FNP Maintenance Department Type Code Symbol Stamp:

NlA Name 738e North Slate Hwy 90; Columbia. AL 36319 Authoilmtlon No.:

NJA Address Expiration Dale:

NlA 4.* Identification of Systsm~

. TPNS:. 0lP16V218D

5. (a) Appllcable ConstructIOn Code:

Section 11\\

, 1971 Edition. Winter 1971

Addenda, NlA COde Case

YeM (b) App&cabIe Eottfon of SectIon Xl Used lor AepafrlRepiacement ActiVity;.

2001 Addenda:.,

2003

--~~~$U~--

(0) Applicable SectIon XI Code Case(S):

NlA

6. IdeIlllllcallon of Components:'

Name of Component Name of Manufacturer Manufacturer Serial No.

National Board No.

Other Idenllflcallon Year Built Corrected; Removed, or Installed ASMECode Stamped (YasorNo)

PIPE McJunkin L6SSOS N/A 7047*0*62574 1973 Removed No VALVE KEROTEST J07*2 N/A FNP*295 1975 Removed YES FIPE Sandvik 513912 N/A PO: OP070626 2007 Installed No VALVE BNL A070809*1*20 NlA PO: OP070775 2007 Installed YES

7. Description of WorIC SW Valve and Pipe Replacement
8. Tests Conducted:'

Hydrostatic []

Pneumatic [J Nominal Operating Pressure Ii!

ExemptC Other CJ psi Test Temp.:

"F NOTE; Supplemental sheets In Jonn ofUsts, skelclles;or drawings maybe used, prOVided (I) size IS 8*1/2111. x 11 in** (2) Information !n Items 1 Ihl'Ol.9l 8 on tbls report IS included on eaol'l sheet. and (3) each sheells numbered and number of ~IS Is recorded al the lop of this fonn*.

FORM NI5-2 (Back)

!t Remarks Reference MDC 1000942001 for reconciliation of material difference AIIP&iIIIt MlJlii&lii@i'iNoatin;;p;& to ¥it 1i1Iit'W-Valva Coda of conlructlon and replacement valve coda is ASME sec. Ill, 1971 edItIon, winter 1971 Addenda wI para NB611'.1C of Winter 1972 Addenda, class 3 Replacement pipe is A$ME See-II & III, Subsection NO, 1986 Edition no addenda, class 3 FNP Piping Specillcation SS110902 allows a conslructioo Code of ASME Section III, 1971 Edition Ihru 2000 Edillon Addenda Vf*2 completed Sat.

Transadion /#'5:190161 CERTIFICATE OF COMPLIANCE I certify that the statements made In the report are correct and that this confonns 10 the requirements of the ASME Code, SectiOn XI.

Type Code Symbol Stamp:

NlA Certificate of Authorizatloo No.:

NJA Expiration Dale:

NlA Signed:

fl"'7'"

Asia O. Jerkins, Maintenance Spt, Support Date: --"k-h-',-,_,------f CIINnJr orOwner's DesJgl189, T1tfe I,

CERTIFICATE OF INSERVICE INSPECTION the components de$critJed In this

_~..ij~~~L-:--~~_ to _~,&..:;.~~_____ ' and state lila! 10 the best of my knowledge and belief, the Owne has armed examinations and lake.

measures described in tills Owner's Report In accordance wt\\ti the requlrumenlS of the ASME Code, SectIon XI.

By signing this certificate neither the Inspector nor his employer makes any WSFTaJlty, expressed or implied, conceming the examinations and corrective measures descrtbed in this Qwne(s Report. Furthennore, neither Ihe Inspector nor his employer shall be Ilable in any manner for any personaIlnjtJry or property damage or a loss of any kind arising from or connectod with this inspection.

nspector's Signature Dam: ____~~~4-__--____---------

FORM NIs..2 OWNER'S REPORT FOR REPAIRiREPlACEMENT ACTIVITY As Required !:Iy the Provisions of the ASME Code,Section XI

II F.

1. Owner:

Southem NllClear Operating Co.

December 9,2010.

Name 40 Inverness Center Parkway; Birmingham, AL 35242 Sheet.,

of 2

Address

2. Plant::

Joseph M. Farley Nuclear Plant (FNP)

Unit:

FNP Unit 1 Nsme 7388 North Stale Hwy 95~ Columbia, AL 36319 Work Order NM P1S ~ 1080942037 Address RepalrlRepl£icemenl Organization PO No, JOb No, etc.

3. Work Pelfonned B~

FNP Maintenance Department Type Code Symbol Starnp:~

NlA

. Nam9 7388 North Siaia Hwy 95;.CoIumbla"AL36319 Authorization No.!

NlA Addrsss E lq)iration Dale,*;

NJA TPNS~ Q1P16V218E* HCC*29 SW Supply 1010 CTMT Cooler Draln (ASME Class 3)

5. (a) Applicable Construction Code:

SectiOn III

  • 1971 Edilloo,. Winter 1971
Addenda, NlA Code Case

y;;;r (b) Applicable Edltlon of Section XI Used lor RepalrlRepiacement ActMty:

2001 Addends:

2003 Year (c) ARJlli::abIe Section XI Code Case(s):

N/A

a. ldentiflcation of Components:

Name 01 Component Name of Manufacturer Manufacturer Serial No.

National Soan:!

No.

Other Identification Year Built Corrected, Removed,or Installed ASMECode Stamped (Yes or No)

PIPE Mcjunkin L65803 N/A 7047-0-62574 1973 Removed No PIPE TIOGA 285192 NlA QP*1674 1987 Removed No ELBOW HUB R95R N/A QP2030 1987 Removed No VALVE KEROTEST J07*3 N/A FNP*295 1975 Removed YES PIPE SANOVIK 513912 N/A QP080626 2007 INSTALLED No ELBOW Bonney Forge 44053 N/A QPloo157 2007 INSTALLED No VALVE BNL A070809*1*16 N/A QP070n5 2007 INSTALLED YES SW Valve and Pipe Replacement

8. Tests CofKtucted:

Hydrostatic 0 Nominal Operating Pressure Ia Exempt 0

____psi Test Temp.~ ____"F Other 0 Pressure:

NOTE: Supplemental sheets in form 01 lists. sketches.. or drawings may be 1l$8d. provided (1) size is ~112'ln, )( 11 in., (2) information In items 1 through 6 on this report Is Included on each sheet. and (3) each sheet Is numbered and number of sheets Is recorded at the lop of this form.

FORM NIS-2 (Back)

9. Aem8lks Reference MOe 1080942001 lor reCQnciHation of material difference AI$&ifQW JGffi&m;;;s; b.1ti ";PO;;1b S; :;t;;&Cf, Valve Code of contructlon and replacement valv9 code Is ASME sec. III, 1971 editiOn. winter 1971 J1.ddenda wI para. N88111.1C Of Winter 1972 Addenda, class 3 Replacement pipe is ASME Sec. II & III,SubSecllon NO, 1986 Edition no addenda, class 3 Replacement ElbOw is ASME Sec. II & III, Subseclion NO, 1983 Edition no addenda, class 3 FNP Piping Specification SS110902 allows a construction Code of ASME Section III, 1971 Edition thru 2000 Edition Addenda VT*2 completed Sal..

Transaction #'s: 190190 CERTIFICATE OF COMPLIANCE Icertify that the statemoots made In the report are correct and that thIS conforms to the requirements of lhe ASME Code,Section XI.

Type COO& Symbol Stamp:

NJA Cel1lficate of Authorization No.:

NfA El¢Iiration Date:

NJA

~ 0'"

Asia O. Jerkins, Malntenance Spt, Support Dale: --,-,1ct-tl.-,;,-,-,...;..-----1 Signed:

--~~~--------~

~(or Owners Dsslgnee, TIfIIJ CERTIFICATE OF INSEAVICe INSPECTION State or Province 01 of have Inspected the components described In this Owner's Report during the rlod to ~J

. and state !hat to lhe best 01 my knowledge and belief. the Owner s

/'formed examinationS and t~COllIe measures described in thIS Owners Report in accordance with the requirements of lhe ASME Code.Section XI.

By siglllng IhIs certificate nei1her the Inspe()tor nor his employer makes any warranty, elCpfessed or implied. conceming the examlnalions and corrective measures described In this Owner's Report. Furthermore, neither the Inspector nor his employer shall be lIabkt in any manner for any personal injulY or property damage or a loss 01 any kind arising !rom or connected with this inspection.

Cornmissions:!!A8~/P:~U~~~~~~-~~--_I NalionalBoard. State. Province. and Endorsements

~-

Date: -_-4~:,a2p~0:.::../___

FORM NIS-2 OWNER'S REPORT FOR REPAJRlREPLACEMENT ACTIVITY As Requimd bK the Provisions of the ASME Code. Seclion XI

1. Owner:

Southern Nuclear Operating Co.

Dale:

December 9. 2010 Nama 40 Inverness Center Parllway; Birmingham. AL 35242 Sheet:

ot 2

Addrass

2. Plant;.

Joseph M. Faney Nuclear Plant (FNP)

Unit; FNP Unit 1


~M~a-m&------~---------

7388 North State Hwy 95; Columbia, AL 36319 Work Ordar No,:

PIS* 1080942038 R8p8irIRep/Scement OrganiZationPO NQ, Job No, etc.

3. Work Pelfonned B~

FNP Maintenance Department Type Coda SymbOl Stamp?

NlA


~M~am&------------------

7388 North State Hwy 95; Columbia. AL 36319 Authorization No,:,

N1A Addrsss Expiration Dale, NlA

4. Identification of System:

TPNS: 01P16V218F - HCC*39 SW Return from 10 CTMT Cooler Drain (ASME Class 3)

5. (a) Applicable Construction cOd&;

Section III

  • 1971 Edition. Winter 1971
Addenda, NlA CotIe Case

.~

(b) ApplIcable E<itlon ot Section XI Used lor Repair/Replacement Activity; 2001 Addenda::

2003

--~Y.~~-r---

(e) Applicable Section XI Code Case{s):<

tWA

6. Identification of COmpooents:,

National Corrected.

ASMECode.'

Name of Other Year Name of Component Manufacturer Serial No.

Board Removed,or Stamped Manufacturer ldentillcatlon Built No.

Installed (Yes or No)

PIPE McJunkin L65803 NlA 7047-0-62574 1973 Removed No VALVE KEROTEST JOH N/A FNp*295 1975 Removed YES PIPE Sandvik 513912 N/A PO: QP080626 2007 Installed No VALVe BNL A07OS09*1-4 NlA PO: QP070nS 2007 Inslafled YES

7. Description of Work:

SW Valve and Pipe Replacement

8. Tests Conducted:

HydrostatIC 0 Pneumallc 0 Nominal Operating Pressure eI Exempt 0

____psi Test Temp.: ____"F Other [J Pressure:

NOTE; Supplemental sheets In form 01 USls. skelches, or drawings may be used. provided (1) size Is 8-1n:;ln. x 11 In** (2) informallon in Items 1 Ihroufjl 6 on this report Is InclUded on each sheet,. and (3) each sheet Is numbered and number of sheels Is recorded at the top 01 this torm.,

FORM NI5-2 (Back) 9; Atmal1<s Reference MDe 1000942001 for recooclnatioo of malerial difference i4PliG6It.~mUl mpo;u/(l&;iiiiiCIiIJlI*

Valve Cooe of contructiOn and replacement valva code Is ASME sec. III, 1971 edllron. winter 1~71 Addenda wi para. NB6111.1C of Winter 1972 Addenda. class 3 Replacement pipe is ASME Sec. II & III, Subsection NO; 1986 Edition no addenda, class 3 FNP PIping Specification S5110902 allows a constructIon Code of ASME Section 11/, 1971 Edition ttlru 2000 Edition Addenda VT-2 completed Sat Transaction It's:, 190197 CERTIFICATE OF COMPUANCE I cerllfy thai the stalements made in the report are cofT'eCt and that this conforms 10 the requirements oIttle ASME Code, S9C!fon XI.

Type Code Symbol Stamp:

NlA Cerlillcate 01 Authorization No.:

NJA Expfmllon Dale:

NJA Signed:

k7 Dale: --h-~-~ru------f Asia O. Jerkins. Maintenance Spt, Support

"'6If'ner Of Owners Designee. Tltls t

CERTIFICATE OF INSERVICE INSPECTION I. the undersigned. holdng a valkI commIsSion tssued by !he NatIonal Board 01 Boiler and Pressure Vesselinspeclors and the Slate or Province of ~

and employed by-u~___c..r';;":;"_______________-I of have inspected !fie components described In this Owner's Report during the nod d

10 ~M/tl

.and stale that fo the best of my knowledge and belief, the ().ome( as ormed examinations and ~rve measures described in this Qwne(s Report in accordance with the requirements of the ASME Code,Section XI.

By signing tills cel1iflcate neither the Inspector nor his employer makes any warranty. expressed or Implied. coocemlng the examinations and corrective measures described In ttlls Owner's Report. Furtllerm()f6. "aUher the Inspector nor his employer shall be liable!n any mannar for any personal injury or property damage or a loss of any kind ariSIng from Of connected with thislnspectlon.

Date:


~~~~---------------

FORM NI5-2 OWNER'S REPORT FOR REPAIRIREPLACEMENT ACTIVITY As Required by the Provisions of the ASME Code,Section XI

1. Owner.

Southern Nuclear Operating Co.

Date:

December 9, 2010 Nams 40 Inverness Center Parkway; Birmlogham. AL 35242 Sheet:

ot 2

c...._ _ _J_O_seph...;..._M a'_le.:.:

2. Plant

...._F... y _N_uc1_El_B_'P_Ia_O_I.;..(F_N_P;..)___

Unit:

FNP Unit 1

-Name 7388 North StatEi Hwy 95; Columbia. AL 36319 Work Order No;:' P16* 1080942039 Address RepalrlReplscsment OiQanlzation PO NO; Job No, etc..

3. Work Performed By:

FNP Maintenance Department Type Code Symbol Stamp:

NlA Name 7388 North State Hwy 95; Columbia, AL 38319 Authorization No.:

NlA E)(plratlon Date:

NlA 4., Identification 01 System~:,

TPNS: Q1P16V218G* HCG-39 SW Return from 10 CTMT Cooler Drain (ASME Class 3)

5. (8) ApplICable Construction Code:

Section III

. 1971 Edition, Winter 1971 Addenda.

NlA Code Case

~

(b) AppItc:ab18 Edition of Section XI Used for Repair/Replacement Activity:

2001 Addenda:

2003

--~y,~~----

(c) Applicable Section XI COde Case(s):

N/A

6. Identification 01 Componentlt:

National Com!c\\ed, ASMECode Name 01 Other Year Name of Component Manulacturef Serial No.

Board Removed. or Stamped Manufacturer Identification Built No.

Installed (yes or No)

PIPE McJunkin L65B03 N/A 7047*Q.62574 1973 Removed No VALVE KEROTEST J07*5 N/A FNP*295 1975 Removed YES PIPE Sandvik 519775 N/A PO: QP090740 2009 Installed No VALVE BNL A070809-1-48 N/A PO: QP07077S 2008 Installed YES 7, Description 01 Work:

SW Valve and Pipe Replacement

8. Tests Conducte<:b Hydrostatic Cl Pneumatic Cl Nominal ()pefatfng Pressure ra Exempt CJ OtherCJ Pressure: ____psi Test Temp;; _____ ~F NOTE: Supplemental sheets kI form 0111818, sketches,~ordrawings may be used, provided (1)s.lze Is 8-112 In. x 11; in., (2) Inlormation In ilems 1 through 6 on litis report Is included on each sheet. and (3) each sheet Is numbered and number of sheet$1s recorded at the lop oIlhis form*.

FORM NI&-2 (Back)

9. RemruXs Reference MOC 1080942001 for reconciliaUon of material difference

.APP!&Iii ~ta m;po;; SIliIlilMJiid Valve COOe.ot contruction and r:eelacement valve code Is ASME sec. III, 1971 edition, winter 1971 Addenda wI para. NOO111.1C 01 WInter 1972 Addenda, class 3 Replacement pipe Is ASME Sao. II & III, Subsection ND. 1986 Edition no a<ldenda. class 3 FNP Piping Specification S5 11 0902 allows a construction Coda of ASME Section III. 1971 Edition thru 2000 Edition Addenda VT*2 completed Sat.

Transaction 6's:192948, 190026 CERTIFICATE OF COMPLIANCE I certify that the statements matfa In the report are correct and that this conforms to the requfrements of the ASME Code, Sectloo XI.

VWOI"I7f '" Owner's Designee. Title t

TYP9 COde Symbol Stamp:

NtA Certllicate of Authorization "

NtA Expiration Date:

NtA Signed;

~, '7,.

Asia O. Jerkins, Maintenance Spt. Support Date:

I/.sk,

---+~~--------~

CERTIFICATE OF INSERVICE INSPECTION State or Pmv\\nCe of of have inspected the components described In this Owner's Report during the period I:)

0 to

/ ~~

, and state that to as p \\'formed examinations and '.;(00 measures described In this Owner's Report in accordance wilh !he requirements of the ASME Code. Sectlon XI.

By signing this ceftificats neither the Inspector nor his employer makes any warranty. expressed or Implied. concemlng the examinatIonS and corrective measures described In this Owner's Report. Furthennore. neither the Inspector nor his employer shall be liable in any manner for any personal Injury or property damage or a \\oss of any klnd arising from or connected with Ihfs inspection.

Dale:

(I¢I

FORM NIS-2 OWNER'S REPORT FOR REPAlRlREPLACEMENT ACTIVITY A$ ResUlrecI by the Prov.IsIons of \\he ASME Code,Section XI

1. Owner.;

Southern Nuclear Operating Co.

Date:

December 9,2010 Name 40 Invemess Center ParkWay; Birmingham. Al35242 of 2

AddlfJSS

2. Plant:'

Joseph M; Farley Nuclear Plant (FNP)

Unit:

FNP Unit 1

~------------~~~----~~------

7388 North State Hwy 95; Columbia. AL 36319 Wor1< Order No.,:, P16* 1080942040 AddlfJSS RepairIRepfacement Organizatron PO NO, Job Na. etc.

3.. Work Performed B~

FNP Maintenance Department Type Code Symbol Slemp:

NlA Name 7388 North State Hwy 95; Columbia, AL 36319 AUIhoifzatlon No;::

NlA Address

~---------------

EJIl)Iration Date:

NlA 4, identification of System; TPNS: Q1P16V218H*' HCC.39 SW Retum from 10 eTMT Cooler Drain (ASME Class 3) 5;: (8) Applicable Construction Codat Section III

  • 1971* Edtlon, Winter 1971
Addenda, N/A Code Case

~

(b~ Applicable Edlilon of SectIon XI Used for Repair/Replacement Activity:,

_--;-:200~1__ Addenda~ _________

2003 Yea' (c) AppUcabIe Section Xl Code C8S&(s);

NlA 6~ IdantifiCalion of Component!r:

Name of Component Nsmoof ManufacturSf Manufacturer Serial No.

Natlonal Board No.

Olber Iden!lfIcaIIon

'lear BuIll Corrected.

Removed. 01 Installed ASMECode Stamped (Yes or No)

PIPE Mcjunkin L6580S N/A 7047*0.62574 1973 Removed No VALVE.

KEROTEST J07-6 N/A FNP*295 1975 Removed YES PIPE Sandvik 513912 NlA PO: QP080026 2007 Installed No VALVE SNl A070809-1*54 NlA PO: QP070n5 2008 Installed YES

7. Descripl(On of Work:

SW Valve and Pipe Replacement So Tests Conducted:'

Hydrostalic 0 Pneumatic [J Nominal Operating Pressure Ii3 Exampt 0 psi Test Temp:;:

'1" NOTE:SUf)plemental sheets Infonn of lists. sketches. or drawings may be used. provided (1) size Is 8-1/2 In. )( 11 in.* (2) infoonation In items 1 through 6 on this report is Included on each sheet, and (3) each stlaet Is numbered and number 01 sheets Is recorded at the top of this lonn.

FORM NI8-2 (Back) 9" Remarks Reference MOC 1080942001 for recoociliatlon of material differen~

A/>PlICi& A1I.tIiiifIIaiIILilt Rli;XiI& sa4Ita<i&d....

Valve Code of contruclion and rAAlacemenl vatvecoda i$ ASME sec. III*. 1971 edltlon! winter 1971 Addenda wi para NB6111.1 c' of Winter 1972 Addenda> class 3 Replacement pipe Is ASME Sec. II & III. Subsection NO, 1986 Edition no addenda, class 3 FNP Piping Specification SS110902 allows a construction Code of ASME Section III, 1971 Edition Ihru 2000 Edition Addenda VT*2 completed Sat,..

Transaction #'s: 190204 CERTIFICATE OF COMPLIANCE I certify that the statements made In the report are correct and that thJs conforms to the requirements of the ASME Code,Section XI.

Type Code Symbol Stamp:

NlA Certificate of Authorlzatlon No.:

NlA Expiration Date:

NlA fi--J....

Dale: -/-"~-~-V-'I-J,---------I Asia O. Jerkins. MainlellMce Spt. Support Signed:

~wnef or OWner's Designee. Title

--'-,;p:.,r..::.a.....-----I CERTIACATE OF INSERVICE INSPECTION I. the W'ldersigned, holding a valid commission issued by the National Board of Boller and Pressure Vessel Inspectors and the Stale or Province of.fj:tJlQ!..t:'

and employed bV_u;:;.::;::::;....;c"r_________________-I of tltfte?ErA!e c:r-have inspected the components described In this Owner's Report during ~period k,/3olLf!>

10 --L.P.:f//1

.and state thai to lhe best of my knowledge and belief. the OWner haS p81formed examinations and t8i<8'lt correCtiVe measures described In this Owner's Report In accordance 'lllilh the requll'9ments of the ASME Code. Secdon XI.

By signing this certIflcate neither the Inspector nor his employer makes any warranty. expressed or Implied. concemlng the examinations and COl'I'EICIive measures described In this OWner's Report. Furthermore, nefther the Inspector nor his employer shall be liable in any manner fOf any pel$Ol18l injury or proj:lefty damage or a loss of any kind aIfsIng !rom or connected with this Inspection.

Inspector'S Slgnatura Date: ____~~~~-------------------

FORM NI8-2 OWNER'S REPORT FOR REPAlRIREPLACEMEN'r ACTIVITY As Requll'55l by the Pl'OI!isioos of the ASME COde. SectJorl XI Southem Nuclear Operating Co.

Date:

November 11. 2010 Name 4Q Inverness Center Parkway; Birmingham; Al35242 Sheet of 2

Address 2; Plant, Joseph M.; Farley NucleElf' Planl (FNP)

Unit:

FNP Unit 1


~--~--N.~8-me--~--~--~-----

7388 North Slate Hwy 95; Columbia, Al36319 Work Order No;:

1082115101,

Address Re(J81riReplscemsnt Organization PO No. Jab No, etc,

3. Work Performed By:

FNP Main,tenance Department Type Code Symbol Stamp:-

NlA Nems 7388 North State Hwy 95: Columbia. Al 36319 Authorization No.!

NlA Address' Expirallon Date; NlA

4. Identification of System!'

Q1P16F021 SlfIlNlET TO 18 EDG AlA COOLANT HX

5. (a) Applicable Construction Code:'

Saetion 11\\

  • 1971 Edition, 1971 Winter Addenda> lln-7 & 1330-3 Code Case

-y;;,:

(h) AppilcableE<ilIon of Section XI Used for RepaJrlAepiooement ActMty:'

2001 Addenda:

2003 Year (c) Appftcable Section XI Code Caae(s):

NlA

6. Iden~lIon of Components:,

National Corrected, ASME Code Name of Other Year Name 01 Component ManufactUl9r Serial No.

Board Removed, or Stamped Manufacturer Idenlificatlon Built No.

Installed (Yes or No)

(8'Y'EXPANSION JOINT TubeTums 47292 NlA FNP359 1974 REMOVED YES STAY ROO NUTS (16)

Unk. Senior Flex.

MTCN: TOllS7 N/A QP081064 2009 REMOVED NO STAY RODS (4)

Unk. Senior Ffel<.

MTCN: TOl167 NlA QP081 064 2009 REMOVED NO MOUNTING STUDS (16)

Unknown Unknown NlA Unknown Unk REMOVED NO MOUNTING NUTS (32)

Unknown Unknown NlA Unknown Unk REMOVED NO EXPANSION JOINT Senior Flexonics K82580-1*4 NfA QP081064 2009 INSTALLED YES STAY RODS (4)

Wean Threaded Pro HT# 10005750 NlA QPOStl01 2009 INSTALLED NO STAYAOD NUTS (32)

Unytil& Inc.

HT'S44035 NlA QP0902B9 2001 INSTAllED NO SPACERS (2)

NUCOR HTII 9103524 N/A QP090737 2009 INSTALLED NO STUDS (16) lulean Threaded Pro HT# 10005750 NlA QPOS1101 2009 INSTALLED NO Mounting Nuts (32)

Nova Machine HT# 241436 NfA QP091144 2009 INSTAlLED NO

7. DescrIpUon of Work:

REPLACED EXPANSION JOINT Ik Tests Conducted:

Hydrostatic 0 Pneuma\\lc 0 Nominal Operating Pressure Ea Exempt [J Other [J P/9SSUr&:

Test Temp.:* ____ '1=


psi NOTE: Supplemental sheets In form 0' lists. sketches. or drawings may be used; provided (1) size is 8-112 In; x 11 in., (2) Information in Items 1 through 6 on this report Is included on each sheet;,and (3) each sheet Is numbered and number of sheets IS recorded at the top of Ihl$ fOlll'L.

FORM NI&-2 (Back)

9. Remruks Jli#'ilSI6iiiIG/iUf.octur;>.- m& mp;;;; 10 &0 aiGl!Ji(j(j Construction code is ASME SEC. Ill, 1971 ED. Thru Winter 1971 Addenda CL 3 Replacement Expansion Joint is ASME SEC. III. 1980 ED. Thru Summer 1982 Addenda, wi Cooo case N*369 CL 3 Expansion Joint reconCiled under ED 1101016501 ED.

Spacer Constructloo is ASME SEC 111.1980 EDITION thru 1982 Addenda cl3 Nuts, Stay Rods Construction Code is ASME SEC III. 1971 Edition thru :WOO Edition/Addenda Replacement Code years are reconciled per FNP PIping Specification 881109-02 VT*2 Perlormed. Sat CERTIFICATE OF COMPLIANCE I certify lhatlhe slatements made in the report are correct and that this conforms 10 the requirements 01 the ASME Code, Section Xl.

Type Code Symbol Stamp:

N/A Expiratlon Date: ____Nl....;.:..;A___-I Certificate of Authorization No.:

MIA Signed:

--f??

Asia O. Jerkins. Maintenance Spl. Support Oala:

I~/',

--4U/~#~~--------~

uwner-uruwners Designee. Title CERTIFICATE OF INSEAVICE INSPECTION I. the undersigned. holding a valid commission issued by the Natlonal Board of Boller and Pressure Vessel Inspectors and the State or Province of

~t= and employed by..Lar.i::k::-...=:L-_________________--I of J/;llq7bi./l cr:

have Inspected the components described in this v

Owner's Report during 1I1e~od

z
aD 10 hjl

'and stale thatla the best of my knowledge and belief. the Owne;t;i'performed 9lC81T'1inations and take~live measures described in this Owner's Report In accoo:Iance with !he requirements 01 the ASME Code.Section XI.

By signing this certillcate neither the InspectOl' nor his employer makes any warranty. expressed 01' implied, conceming the lI)CaIIlinatlons and correcllllQ measures described In this Owner's Report. Furihennore. neither the Inspector not his employer shall be Rabie in any manner fOl' any personal Injury or propet1y damage 01' a lOSS of any kind arising from 01' connected with this Inspection.

O&e: ______~~~__--__----------

FORM NI5-2 OWNER'S REPORT FOR REPAIR/REPLACEMENT ACTIVITY As Required by the ProvlsfOOs of the ASME Code,Section XI 1.1 "e

1. Owner:

Southern Nuclear Operating Co.

November 30, 2010 Name 40 Inverne$S Center Parkway; Birmingham, AL 35242 Sheett t

of Addr&$S*

2. Plant.

Joseph M.Farley Nuclear Plant (FNP)

Unit:

FNP Unill


~N~am~e----------------

7388 North Stale Hwy 95; Columbia, AL 36319 Wort Order No.:

WO 1082120801 Address Repair/Replacement Organization PO No, Job No, etc.

3.. Wort< Pelformed By::

FNP Maintenance Department Type Code Symbol Stamp~

NfA Nal7l6 7388 North State Hwy 95; Columbia, AL 36319 Alilttorizalion No.:

NfA ExpiratfOO Dale:

NfA 4*. ldentiflcatlon of Systent~

TPNS :,01P16F025 SERVICE WATER INLET TO 1C EOG AIR COOLANT HX (code class 3)

5. (a) Applicable ConSlructlon Cod~

Section III

, 19BO Edillon;, 1982 Summer Addenda.

N/A COde Case

~

(b) Applicable Edition of SectIon XI Used for RepalrlReplacement ActiVity:'

2001 Addenda:

2003

--~y.~&V----

(0) Applicable Section XI Code Case(s)J N/A

6. Identification of Component~

Name of Component Name 01 ManufactulUf Manulacturer Serial No.

National Board No.

Other IdenlltJcatlon Year Built Corrected, RemOVed. or Installed ASMECode' Stamped (Yes or No)

Expansion Joint al1<er Metal Bellow.

001 N/A QP7464 1992 REMOVED YES Stay Rod Nuts (32)

Unk. (5r FI&xonICS) unknown N/A (OPOS1064) 2009 REMOVED NO Stay Rods (4)

Unk. (Sr flexonlcs) unknown NfA (OP081064) 2009 REMOVED NO Expansion Joint Senior Flexonics K82S80*2*4 N/A OP081064 2009 INSTALLED YES Slay Rod Nuts (32)

Trust Mfg.

HT#459810 N/A QP090279 2007 INSTALLED NO Stay Rod Nuts (1 )

Nova Machine HT# S67159 NfA QP060613 2004 INSTALLED NO Stay Rods (4)

Nova Machine HT#3001306 N/A OPQ90837 2008 INSTALLED NO 7, Dascripllon 01 Work:"

REPLACEMENT OF EXPANSION JOINT 8, Tests COnducted:

HydrostatIC [J PneumaUC; [J Nominal Operating Pressure Ii!

Exempt

[J

_____Psi Pressure:

Test Temp.: -----

"F Nore: Supplem8nlal sheets In form of lists, sketches. or dlawlngs may be used. provided (1) size Is 8-1/210.. x 11 in., (2) Infonnatlonln Items 1 throu{jl6 on this repo/tls Included on each sheet, and (3) each sheet Isnumbered apd numbel of sheets Is recorded at the top ~ this fonn.*

FORM NIS-2 (Back) 9, Remarks Raplacemam Expansion Joint code Is ASME Sec. III. 1980 Edition Ihru Summer 1982 Addernta class 3 with cc N*369 J1ilj:iIiC&~bIiIii.m;;o;; 10 6i~

Replacement 91f!nsion joint approve/reconciled under EO,1 092202301 EO Stay Rod Nuts are ASME Section III. 1989 edition class 1 (ref. FNP PIpIng Specillcatlon 551109*02 Stay Rods are ASME Section III, 1983 edition class 2 (reI. FNP PIping SpecifICation 851109-02 VT*2 compleled Transaction II's are: 171213.. 171227 CERTIFICATE OF COMPLIANCE I certify that the statements made in the report 31'e correct and that this confonns to the requirements of the ASME Code,Section XI.

Type Code SymbOl Stamp:

NlA Certificate of Authorization No,:

NlA Exp/ralloo Date: ____Nl_A___-I Signed:

~""7.-"..

Asia O. Jerkins, Maintenance Spt, Support Data:

II,;',

--~~---------I' ClWner or Owner's Desif}f166. Title CERTIFICATE OF INSERVICE INSPECTION I, the underSIgned, holding a valid commission Issued by the National Board of Boiler and Pl'essure VassellnspectolS and the State or Province of

~4:: and empioyed by_L..lIOO.a...!~~I--_~_____________"

of haVe Inspected the components deSCribed in this Oooers Report wring the palled

~

to

-d/,,:./JI

.and state thalIa the beSt of my knowledge and bellel, the OWner h s rformed examinations end taketrOO~ive measures descnbed In ItlIS OMier's Report in accordance with the requirements of the ASME Code.Section XI.

By signing Itlls certificate neither Itle Inspector I'lOf his employer makes any warranty, expressed or implied, concerning the examfnatioos and col'I'IIClive measures described In this OWner's Report. Furthennora, neither the Inspector nor his employer shall be liable In any manner lor any personal injury or property damage or a loss 04 any klod arising lrom or connected with this Inspeclioo, Date: -*4ol~-----------

FORM NI8-2 OWNER'S REPORT FOR REPAIR/REPLACEMENT ACTIVITY As Required by the.Provlsioru:l of the A$ME Code,Section XI

1. Owner.

Southern Nuclear Operating Co.

Dale:

November 11,2010 NSffl6 40 Inverness Center Parkway; Birmingham. AL 35242 Sheet of 2

Addmss 2.* Plant:

Joseph M. Farley Nuclear Plant (FNP)

Unit:

FNP Unit 1

-<'---.;....-.-~-:-----.;.......;---

NSffl6

. 7388 North Slate Hwy 95; Columbia, AL 36319 Work Order No.:

1082121101 Address.

Repair/Replacement OtgSflizatiOn PO Nc, Job No. etc...

3. Work Petformed By; FNP Maintenance Department Type Code Symbol Stamrr.

NlA NSffl6 7388 North State Hwy 95; Columbia, AL 36319 Authorization No.~

NlA AddfS8S EKPiration Date:

NlA 4, Identification of System!

01 P16F0513 SW OUTlET FROM lC EDG JACKET COOLANT HX

5. (a) Apf:lIIcabIe Construetlon COde!

Section 111

  • 1980 Ealtlon, 1982 Summer Acidemia, N*369 Code Case YeM (b) Applicable Edition of Section XI Used fot RepairlRepiacement Activity:

2001 Addenda:

2003 Year (c) AppIIcabIa SectIon XI Code Case(s}:

NlA

6. Idenlifleatioo of Components; National Corrected, ASMECode Name 01 Other Year Name ot Component Manufacturer Serial No, Board Removed.ot Stemped Manufacturer ldenllltcation Built No.

Installed (Yes or No)

EXPANSION JOINT Parker Metal Bellow.

.Jm..

N/A OP93*124S 1993 REMOVED YES STAY ROD NUTS (32)

Unk. Senior Flex.

Unknown N/A QP081 064 2009 REMOVED NO STAY RODS (4)

Un!<. Senior Flex.

Unknown NlA QPQa1064 2009 REMOVED NO NUTS (a)

Unknown Unknown N/A Unknown Unk REMOVED NO STUDS (9)

Unknown Unknown N/A Unknown Unk REMOVED NO EXPANSION JOINT Senior F1exonics K82580*2*1 N/A QP081064 2009 INSTALLED YES STAYAOO NUTS (32)

Trust MFg.

HT# 459810 NlA QP090279 2007 INSTALLED NO STAY RODS (4)

Nova Machine HTlt3001306 N/A QP090837 2008 INSTALLED NO NUTS (8)

Nova Machine HT#241436 NlA QP090992 2008 INSTALLED NO STUDS (9) iUlcan Threaded Pro HT#731381 N/A QP090766 2004 INSTALLED NO

7. Description of Work:.

REPLACED EXPANSION JOINT 8~ Tests Conducte<t Hydrostatic CJ Pneumalia []

Nominal Opemting Pressure Ea E)(6mpt [J 0Iher[J Pressure:

Test Temp:: ____"1=


psi NOTE: Supplemental sheets In form 01 lists, sketcheS, 0.- drawings may be used. prollided (1) Size Is EJ,.1flln. x 1.1 In., (2) Informallon In items 1 through 6 on this report is Incfuded OIl each sheet, and (3) each sheet is rn.mbered and number of sheets Is recorded at the top of this form.*

I

FORM NIS-2 (Back)

9. Remruka Al$IiIIIiIII WIl&ClIIIQ>. biJllm;:;o;1;1O/lO ii&diid Construction code is ASME SEC. III. 1980 ED. Thru Summer 1982 Addenda Cl3 Replacement Expansion Joint is ASME SEC. III. 1980 ED. Thru Summer 1982 Addenda. wI CO<I6 case N*369 CL 3 Expansion Joint reconciled under ED 1092202301 ED~

Nuts, Stay Rods Construction Code Is ASME SEC 111,'1971 Edition Ihru 2000 EditionlA~da Replacement Code years are reconciled par FNP Piping Specification SSl109*02 VT-2 Performed. Sat CERTIFICATE OF COMPUANCE I certify that the statements made In the report are correct and that thls conforms to the requirements of the ASME Code,Section XI.

Type Code Symbol Stamp:

NlA Certificate of Authorizallon No.:

NJA Signed:

Date: I/!0 hi owner or Owners /J6signee. TItle I

CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, hOlcflng a valid commIsSion Issued by the NaUonal Board of Boiler and Pressure Vessel Inspectors and the Slale or Province of

~1":

'::,.".;....;::cr;;:....

and employed by_UliiI:.~'iIi:'

______~-_-___:'-~~~_I of

.~. ~ '..

have Ill$PeCted the<<Hllponents described in this OMler's Report during the t1:riod uGh

.to J.h4h,

.and Slate thaI to the best of my knowledge and belief*, the o~performed examinations and taken ~e measures descnbed In this OMler's Report In accordance with the requirements of the ASME Code. section XI.

By signing this certificate neither Ihe Inspector nor his employer makes any warranty. expmssed or Implied, concerning the examlnalions and corrective measures described In this Owner's Report. Furthermore. neither the Inspector nor his employer shall be liable In any manner for any persona/Injury or property damage or a loss of any kind arising from or connected with Ihls Inspection.

COmmiSslons;i JtQJ1kM-,;-'........... hAl NalfonalBoatd. State, Province. and Endotsemenl$

0_

jLtfi.

FORM NIS-2 OWNER'S REPORT FOR REPAJRlREPLACEMENT ACTIVITY Ali Reqg'red by the Provisions of the ASME Code, SecliQn XI

1. Owner.

Southern Nuclear Operating Co.

November 22. 2010 Name 40 Inverness CenterParkwayj Blnnin{jlam. AL 35242 Sheet:

01 2

Addtess

2. Plant: ____

..,_Fa_t1_ey~N-u-c-Ie-ar-P-lan-t<;..F_NP...;)_---

Unit!

FNP Unit 1 J_O_Seph..;..._M_

Name 7388 North Slate Hwy 95; Columbia, AL36319 Wad< Order No.:

1082121201 RepaJrlRePlBCI!NTI8nt Organization PO No, Job No, etc.

a WOI1< Performed By:'

FNP Maintenance Department NarmI 7388 North State Hwy95; eolumbla, AL 36319 AuthOl'lzatlon No;:

N1A AddteSS Elq)Iratlon Date:

NlA

4. IdentIflcatIon of System; Q1P16F0504
5. (a) Applrcable Construction Coda:

Section III i

1971 Edition.

1971

Addenda, 11n*7&133003 C()(jaCase

..... ~.....--------

(b) Applicable Edition of Section XI Used tor Repalr/Replacement ActIvity:

2001 Addenda:

2003 Year (c) Applicable SectIon XI Code Case(s)!'

NlA 6, Identification of Cornponen~

National eo~ed.

ASME Code Name of Other Year Name ot Component Manufacturer Serial No.

Board Removed,Of Stamped Manufaclul8l' Identification Built No.

Installed (Yes or No)

Expansion Joint Moore Handley 47295 NJA PO; FNP359 1974 REMOVED YES Stay Rod Nuts (16)

Moore Handley 47295 NJA PO: FNP359 1974 AEMOVED YES Stay Rods (4)

Moore Handley 47295 NJA PO: FNP359 1974 REMOVED YES Mounting Studs (16)

UNKNOWN UNKNOWN NJA UNKNOWN UNK REMOVED No Mounting Nuts (32)

UNKNOWN UNKNOWN NJA UNKNOWN UNK REMOVED No Expansion Joint Senior Flexonics K82580*2*1 !hru 2*4 NJA PO: QP081064 2009 INSTALLED YES Stay Rod Nuts (32)

NOVA MACHINE 5092414 NJA PO; OP1oo580 2010 INSTALLED No Stay Rods (4)

~ID SOUTH Noolea 10005750 N/A PO: QP091101 2009 INSTALLED No Mounting Nuts (32)

NOVA MACHINE 5092414 N/A PO; QP100560 2010 INSTALLED No Mounting Studs (16)

~ID SOUTH Nuclea 10005750 N/A PO: OPQ91101 2009 INSTALLED No Spacer MID SOUTH Nooles 9100524 NIA PO: QP0907S7 2009 INSTALLED No

7. Description of Work::

REPLACE 6" EXPANSION JOINT

8. Tests Concitcted:

HydrOstatfc [J Pneumatic C Nominal Operating Pressure &!I Exempt C Other[J psi NOTE: Supplemenjal sheetslri form of 1Is1s. sketches; or drawings may be used; provided (1) size Is 8-112 In.. x 11 In.*.(2) Information In hems 1 through 6 on Ihls report Is Included on each sheet. and (3) each sheet Is numbered and number of sheets Is mcorded at the top of Ihls form.

FORM NIS-2 (Back) 9< Aamarl/d

'and slale that to the best of my knowledge and belief. the Owner ~pQrforrned examinations and tak~ective measures descnbed In this Owner's Report In accordance with the requirements 01 the ASME Code,Section XI, By signing this certiflcete nelllter the Inspector nor his employer makes any warranty, expressed or implied, concemiflg the examinations and corrective measures described in thiS Owner's Report. Furthermore, neither the Inspector nor hiS employer shall be liable in any manner for any personal Injury or pmpeny damage or a loSs of any kind arising from or connected with this Inspection.

Commissions:Ili3~,""7..L-

.. n........ d:;t:A)

National Board. State. Provlncs. and Endorsements Date:

I~h


~/~~,~-----------------

FORM NI8-2 OWNER'S REPORT FOR REPAlRJREPLACEMENT ACTIVITY As Required lit the Provisions of the ASME Code. SectIon XI

1. Owner:

SolJlhem Nl.Icle8J' Operating Co.

Dal&!-

November 11, 2010 Name 40 Inverness Camet Parkway: Binnlngham. AL 35242 Sheet of

2

.2. Plant Joseph M. Farley Nucls8J' Plant (FNP)

Unit; FNP Unit 1


N~a-me------~~-------

7388 North Stale Hwy 95i Columbia. AL 36319 WOffr. Order No.:

1090170301 Addmss RepaJrlRepilicement Orgsnlzalfcn PO No; Job No. etc; 3*. Work Porformed By:;

FNP Mainlenance Department Type Code Symbol Stamp:.

NlA Hems 7388 North State Hwy 95; Columbia. AL 36319 Authort2:8lion No;:

N/A Address Explmtlon Dale:

NlA

4. IdenllficallOn of System~

01P16F0508 SERVICE WATER OUTLET FROM 19 EDG LUBE OIL HX 5; (a) Applicable Construction ~,

Section III

, 1971 EditkIn, Ihru 2000 Addenda; Nla Code Case

~

(b) Applicable Edition 01 Section XI Used for RepalrlReplacement AclIvfty:

2001 Addenda!

2003

--~Y.~8.~*--

(e) Applicable SectIon XI Code Case(S)i NlA

6. ldent!ficallon of Componern&

National Corrected, ASMECode Nemeof Oth8l Ye8J' Nsme of Component Manufacturer Serial No.

Board Removed. or Slamped Manufacturer ldentlflcallon Built No.

Installed (Yes or No) 3/4" STAY ROD NUTS (16 Unytlte. Inc.

HTfS44035 N/A OP090289 2001 INSTALLED NO

7. Description of Work:

ADDEO 16 STAY ROO NUTS FOR EXPANSION JOINT

8. Tests Conducted:

Hydrostatic Cl Pneumatic []

Exempt S2I Other Cl Pressure:

psi Test Temp.:.

of NOTE:StJA)lemenlai sheets In form of Hsts,sketches, or drawings may be used. provided (1) size Is a.1i2ln. x 11 In., (2) Informatlon In items 1 Ihroogh 6 on Ihls report IS Included on eacIl sheet; and (3) each sheet Is {lumbered and.numbat of sheets Is recorded at the lop of this form.

FORM NIS-2 (Back)

9. Remal1ts
J.iiiiiG&Ijj ~&ii"",*, /0 S; lRiCIiIOd Construction code Is ASME SEC. III. 1971ED. ThN Summar, 2000 Addenda CL3

. Replacement code Is ASME SEC. III, 1989 Edition cllI Reference FNP Piping Specilieallon 881109*02 allows a Construction Code ASME Sec. III, 1971 Edition IhN 2000 Edition/Addenda Per design Drawing Flexonlcs Expansion Joint requires addiUonaJ Nuts (16) on inside 01 alllhreads as well as outside Transaction /f:,173753 CERTIFICATE OF COMPLIANCE I certify that 1M statements made In the report are correct and that Ihls conforms to the requirements 01 the ASME Code. SecHon XI.

Type Code Symbol Stamp:

N/A Certificate of Aulhortzallon~

NlA ExpiraHon Date:

NlA S~ed:

~. ~.....

Asia O. Jerldns. MaIntenance Spt, Support Date:

I/,of"

--~~r-~------~

'Owr7Ifr or Owners DesigrlBtl. Tdle CERTIFICATE OF INSERVICE INSPECTION I, the undersIgnad. holdng a valid commission Issued by the Nalional Boan:I 01 Boller and Pressure VessaiinspectOfS and the Stale or Province of q~.f:: and employed by--'-=:;::.....<!..~r~____________~-:---:--I of haw inspected the COI'Ilf)OflEKIts described in this Owner's AepoI'I during the period D

to 1~4/II

. and state that 10 Ihe best of my knowledge and betief. the Owner.6as rformed examinations and taken ~~easures described In this Owner's AepoI'I in accoldance with the requirements of the A8t.tE Code,Section XI.

By signing this certilicate nellher the Inspector nor his employer makes any warranty. eXJlressed or Implied. concerning !he examinatiOns and corractIve measures described In this Ownar's Report. Furthermore. neItheI the Inspector nor his employer shall be liable In anV manner lor any personal Injury or property damage or a loss of any kind arising (rom or connected with \\his Inspection.

Date:

~¥I

2 FORM NIS-2 OWNER'S REPORT FOR REPAIR/REPLACEMENT ACTIVITY As l1e~ulred by the Provisions 01 the ASME Code,Section XI

1. OWner:

Soutllern Nuclear Operating Co Dale:

December 14. 2010 Name 40 Inverness Center Parkway; Birmingham, AL 35242 Sheet:

ot Address

2. Plant Joseph M Farley Nuclear PlanI (FNP)

Unit:

FNP Umll


~----~N~S-m-e------~--~------

7388 North Slatt! Hwy 95; Columbia. AL 36319 Work Order No.:

PIS-1090017402 Address RepairiReplSCfJment Organization PO No, Job No, etc.

3. Work Perlormed By:

FNP Maintenance Department Type Code Symbol Stamp:

NIA Name 7388 North Stale Hwy 95; Columbia. AL 36319 Authorization No.:

N/A Address Expiration Date:

N/A

4. ldantilicatiorl of System:

TPNS 01PI6*HBC*201 MOC 109067740228 DIESEL GENERATOR SW SUPP FROM (ASME Class 3)

5. (a) Applicable Construction Code:

Section /1/

. 1971 Edillon.

Ihru 2000 Addenda.

N/A Code Case Year (b) Applicable Edition ot Section XI Used for Repair/Replacement Activity:

2001 Addenda:

2003 Year (c) Applicable Section XI Code Case{s):

NA 6 Identification of Components' National Corrected, ASME Code Name of Other Year Name of Component Manutacturer Serial No.

Board RemOVed. or Stamped Manufacturer Identification Built No.

Installed (Yea or No)

Concentric Aed 12,,8 In Grinnel ZAT N/A FNP-21O 1973 Removoo No 8" sch 40 pipe(JF4-1008)

In Grinnel 29859 NlA FNp*210 1973 Removed No S" sch 40 Elbows(JF4-1oo ITT Grinnel UR3N NIA FNP*210 19'13 Removoo No S" sch 40 pipe{JF4*1008)

In Grinnel 25374 NfA FNP*21O 1973 Removed No 8" sch 40 Elbow(JF4-1009 tnGrinne' AMCL NfA FNp*210 1973 Removed No 8" scll 40 pipe(JF4.1009)

In Grlnnel 29859 NlA FNP*21O 1973 Removed No 2*8" WN Flange(JF4-1010 ITT Glinnel UR3N N/A FNp-21O 1973 Removed No 3/4" studs (24)

Unk Unk N/A Unk Unk Removed No 3/4" Nuts (40)

Unk Unk N/A Unk Unk Removed No S" WN Ffange(JF4.779)

ITT Grinnel G8CB N/A FNP2*26 1974 Removed No 8" sch 40 plpe(JF4* 779}

ITT Grinnel 24607 NfA FNP2*27 1974 Removed No 314" Nuts (8)

Unk Unk N/A Unk Unk Removed No Concentric Red 12)(8 Taylor Forge MUUS*1 NlA QP100384 2010 Installed No 8" sch 40 pipe INa/sin 30926 N/A QP1Q0384 2009 Installed No 8" sch 40 Elbow(4)

Taylor Forge MVUN*l N/A QPloo384 2010 Installed No 8' WN Flar.ge(3) t-/ewman FlangetFit!

H585 NlA QP100384 2010 Installed No 3/4' studs (8)

T&T 414880 N/A QP080239 2008 Installed No 314' Nuts. (8)

NOVA 5092414 N/A QP100560 2010 Installed No 3(4" stud!; (16)

NOVA 7800104 N/A QP090495 2009 Inslalled No 8' WN Flange(l)

Newman Flange/Fl11 H585 N/A QP100384 2010 Installed No 8' sch 40 pipe Walstn 30926 N/A QP100384 2009 Installed No 3/4' studs (24)

NOVA 5092414 NfA QPI00560 2010 InSlalled No W4Xl3 Beam Nucor 1901315 N/A QP090376 2009 Installed No Spectacle Flange Tioga 0460X4CB*2 N/A QP1 00560 2010 Installed No

7. Description of Work:

SW Pipe Replacement/Installation per MOe 1090677402

8. T esls Conducted:

Hydrostatic 0 Pneumatic 0 Nominal Operating Pressure

~

Exempt D Other 0 Pressure:

psi Test Temp.:

OF NOTE: Supplemental sheets in form of lists. sketches. or drawings may be uSed. provided (1) size is 8*1/2 in. )( 11 In.* (2) information in items 1 through 6 on this report is Included on each sheet, and (3) each sheet Is numbered and number of sheets is recorded at the top of this form.

FORM NIS-2 (Back)

9. Remarks Reference MOe 1080942001 for reconciliation of materia/paIll drHelence
appi&6i8 ManutBcWte?9 bats Repott. to be attaChed All Replacmen! pip!. fiUlngs, are reconciled through MOe 1080942001 and FNP PIping Speclficallon S511 0902 FNP Piping SpecificatIon SS110902 allows a construction Code of ASME Section III. 1971 EdrliOflthru 2000 Edition Addenda Strucillral Beam component IS per AISC 1969 code class 3 VT*2 completed Sal.

Transaction II's: 191446. 192722. 196334 CERTIFICATE OF COMPLIANCE rcertify that the stalements made in the report are correct and that this conlorms 10 the requirements of the ASME Code. Secllon Xl.

Type Code Symbol Stamp:

NJA CertHlcate of Aull1orizallon N~

NIA ExpIration Date:

NIA Signed:

0 /"}

Asia 0 Jerkills. Maintenance Spl. Support Dale:

A 1/'81/'/

~~~~~------------i OWner or owner'S Designee, Tiffs CERTIFICATE OF INSERVICE INSPECTION I. the undersigned, holding a valid commission issued by Ihe National Board of Boiler and Pressure Vessel Inspectors and the State or Province 01 ~/.k and employed by__"""'='--......;;;;;.L._-:-____"':"'":'_____-:--~~~~_I of I,#O?;IJGC2 Q::

have inspected lI1e components described In this Owner's Rep6rt during' the peri~

!l./;.;/t 0 to

..u7-2//1

. and stale that to the beSt of my knowledge and belief. the Owner hal;;eFotmad examlnalions and taken (Iof(ecti6e measures described in this Owner's Report in accordance With the requirements of the ASME COde.Section XI.

By slgnlng this certificate nalther the Inspector nor his employer makes any watranty, expressed or implied, conceming the examinations and corrective measures describOO In this Owner's Report. Furthermore. neither the Inspector nor his employer shall be liable in any manner for any personallnjllry or property damage or a loss of any kind arising from or connected with this Inspection.

Dale: ---4&'~:,.::...'-L..---------

FORM NIS-2 OWNER'S REPORT FOR REPAIR/REPLACEMENT ACTIVITY As Required by the Prollisions ollile ASME Code,Section XI d fe

1. OWner:

Southern Nuclear Operating Co.

Date:,

December 1, 2010 Name 40 Inverness Cenler Parkway: Birmingham. AL 35242 Sheet:

of 2

Addtess

2. Plant Joseph M. Farley Nuclear Plant (FNP)

Unit FNP Unit 1 Name 7388 North State Hwy 95: Columbia, AL 36319 Work Order NQ.: WO 1090805801 AddteSs Repair/Replacement OfYanlzatlon PO No, Job No, etc.

a Work Performed By:

FNP Maintenance Department Type Code Symbol Starnp:,;

NJA Name 7388 Norlh Slate Hwy 95; Columbia, AL 36319 AuII1ori:zalion No,~

NJA AddleSS Expiration Dale:

NlA TPNS ; 18 STEAM GENERATOR PRIMARY MANWAY (code class 1).

5., (a) Applicable Construction Code~

Seclion III

, 1989 Edition, no Addenda.

NlA Code*Csse

~

(b) Applicable Edition of Section XI Used lor R&pai(/Fiep/acement ActMty:

2001 AddendlJ:,;

2003

--~y,~&U----

(c) ApplIcable Seclion XI Code Case(s),

NlA 6: l,def1IlfIcallon of Components!,

National Corr8Cted, ASMECode Name 01 Other Year Name of Component Manufacturer Serial No.

Boald Removed,or Stamped Manufacturer Identification Built No.

Installed (Yes or No)

Primary Manway Stud (1)

Westinghouse unknown N/A unknown unk Unknown NO Primruy Manway Stud (1)

Westinghouse 8967428H5968 N/A QP040919 2005 INSTALLED NO REPLACEMENT STUD

8. Tests Conducted:

Hydrostatic [J Pneumatic CJ Nominal Opemting Pressure iI Exempt [J Other [J Pressure:

psi TeSI Temp.' ____ "F NOTE: Supplemental sheets in form ~ nsts. sketches, or drawings may be used. provided (1) sizl) is 8,112 in. x 11 in" (2) Information In items 1 Ihrough 6 on IIlls report Is Included 00 each sheet. and (3) each sheet Is numbered and number of sheets is recorded at the top of thIs lorm.

01 FORM NI$-2 (Back) 9.- Remarks Replacement 01 Stud per ASME Section III. 1989 EDITION. no acidemia class 1 Transaction It: 197431 VT*2 Completed Sal, VT*1 Completed Sat CERTIFICATE OF COMPLIANCE I certify that lhe statements made in the report are ctlrrect and that this conloims 10 the requirements of the ASME Code.Section XI.

Type Code Symbol Stamp:

NlA Certificate of Aulhorlzauo~.;

N/A Expiration Date:

NlA Signed:

~f ~

~

ror O AsiaO. Jerkins. Maintenance Spl, Support wner's Designee, Title Dale:

~ IIA/;'

~rc.J~,t.l------I CERTIFICATE OF INSERVICE INSPECTION I. the undersigned. hokling a valid commission Issued by the Nallonal Board of Boiler and Pressure Vessel Inspectors and !he State or Province of 4'P7ftt/,f:

and employed by....J.:u:J~-!=:L_______________--f, have Inspected the componenlS descttled In this

'I 10

.and slate Ihat to

,/H/II the best of my knowledge and belief. the Owner h donned examinations and taken ~ measures described In this Owner's Report in accordanCe with the requirements of the ASME Code.Section XI.

By signing this certificate neiiher the Inspector nor his employer makes any warranty. elqJfeSS9d or implied. concerning the examinations and conective measures descnbed in Ihls Owner's Report. Furlhennore. neither the Inspector nor his employer shall be Hable in any manner for any personal Injury or property damage or a loss 01 any kind arising from Of connected with tills Inspection.

Date: _~&-;;...;c...~=.:::#J________

/7

FORM 1'115-2 OWNER'S REPORT FOR REPAlRJREPLACEMENT ACTIVITY As Required by the Provisions 01 the ASME Coda,Section XI Ii

1. Owner.

Southern Nuclear Operating Co" Date:

December 1, 2010 Name 40 Inverness Center Parkway; Biimingham, AL 35242 Sheet:

01 2

2. Plant Joseph M, Farley Nuclear Plant (FNP)

Unit:

FNP Unit 1


~----~N~ame~-¥--------------

.7388 North State Hwy 95; Columbia, AL 36319 Wort<. Order No.:

1090839501 Address RspslrIReplSC6ment OrgenizatfOn PO NO, JOb No; em;

3. WOI1C PEllfonned By; FNP Maintenance Department Type Code Symbol Stamp:

NlA


~N~a~m6~**~*~'~~~---------

7388 North Stale Hwy 95; Columbia, AL 36319 Authorization No.,;

N/A Expiration Date:

NlA

4. ldenllficallon d System:

TPNS: 01E11VOOl5AA RHR PMP SUeT RELIEF VALVE (00de class 2)

S. (a) ApplIcable Constructloo Code:

Saelion III

, 1968 Edition, 1970 Addenda.

NiA Code Case


-:y;;;;-

(b) Applicable Edtlon of Section XI Used for AepaJr/Replacement ActMty; 2001 Addenda:

2003

--~Y,~8a-r--

(0) Applicable Section XI Code Case(s):

N/A

6. Identification of Components:

National Corrected, ASMECoda Named Other Year Name of Component Manufacturer Serial No.

Board Removed,or Stamped Manufacturer fdentfflca!lon Built No.

Installed (yes or No) 3 x 4" Relief ValVe Crosby VIv & Gage N55222*00.oooS Nia 38068 1986 REMOVED NO 3 x 4" Relief Valva Anderson Gmwd C N55222*00*0012 Nia OP091152 2010 REMOVED NO

7. Descrlptlon of Work:

REPLACEMENT RELIEF VALVE

8. Tests COnducted:

Hydrostatic []

Pneumalic [J Nominal Operating Pressure iii Exempt CJ other CJ

____psi Test Temp;*:* ____"F NOTE:.SuppJemerl.lal stleets in fann oltists. sketche&. or drawings may be used, provided (1) size is 8-11210. x 1 t in., (2) Infonnationln Items f through 6 on this report is Included on. each sheet. and (3) each sheet Is numbered and number of sheetS is recorded at the tOP of this fonn.*

FORM NIS-2 (Sack)

9. Remarks Replacement valve construction Is.ASME.Sec. III 1968 Editian*. thru 1970 Addenda COde class 2..

Reference:

ED C102798601 lor material grade changes btw replacamenl valves vr*2 Completed Sat.

Transaction #'5: 35852 CERTIFICATE OF COMPLIANCE I cenlfy that the statements made in the report are correct and that this COOfOffilS to the requirements of the ASME Code, SecHoo XL Type Code Symbol Slemp:

N/A Certificate of AutholfzaOOn No.:

N/A E>eplralion Date: ____.:.;NI:,.:.A.:.....__-a Signed:

~7 Asia 0, Jerkins, Maintenance Spt. Support Date:,/;h

"""'Owner orOwnets Des/gnell, TiUe

-~

,'::.f-~------f CERTIFICATE OF INSERVICE INSPECTION have Inspected the components described In this riod to ~~

, and stale that.o Ihe best of my knowledge and belief. the Owner s

onned examinations and n

e measuteS descnbed In thiS Owner's Report In accordance with the requirements 01 the ASME Code.Section XI.

By signing this celtlficate neither the Inspector nor his employer makes any wananty. expressed or implied. concerning the examinations and oomlCtlve measures described in lhIs Owners Report. Furthermore. neither the Inspector nor his employer shall be liable In any manner for any personal Injury or property damage or a loss of any kind arising from or connected wi1h this Inspection.

~-

ome: ____~~~~-----------------

FORM NIS-2 OWNER'S REPORT FOR REPAlRlREPlACEMENT ACTIVITY As Required by the Provisions ollhe ASME Code,Section XI

1. Owner.

Southem Nuclear Operating Co*..

Date; December 1. 2010 NSm9*

40 Inverness Center Parkway; Birmingham, AL 35242 Sheet ot 2

Address

2. Plant:

Joseph M*. Farley Nuclear Plant (FNP)

Urilt:

FNP Unit 1


~----~M~~--------~~------

7388 North State Hwy 95; Columbia. AL 36319 WOfk Order No.:' 1090839502 Address.

RepalrlReplsc9m8nt Organization PO No. Job NlJ. Sic".

3*. *WOfk Performed By:

FNP Maintenance Department Type Code Symbol Stamp:

NlA Name 7388 North Slate Hwy 95; Columbia, AL 36319..

Authorization No.:

NlA Address EXpiration Date:

N/A 4, Identification of SystenK TPNS:.Q1El1VOO15B B RHR PMP SUCT AELlEFVLV (code class 2)

5. (a) Applicable Construction Code:

SectfOn III

, 1968 Edition.

thN 1970

Addenda, Nla Code Case

~

(b) Applicable Edition of Seclion XI Used for Repair/Replacement ActiiIity; 2001 Addenda:

2003 Year (c) ApptlcabIe Section XI Code Cass{s):

N/A

6. Identification of Components:>

Nalional Corrected, ASMECode Name of Other Year Name of Component

~aclurar Serial No.

BoaJd Removed,or Stamped Manufaclul8l' IdenlilicaUon Built No.

Installed (Yes or No) 3" )( 4',11 Relief Valve Crosby VIva &GaQE N55222-QO'()()10 Nla QP155 1986 REMOVED NO 3' x 4',11 Relief Valve Anderson Grnwd C N55222'()()'OO13 Wa QP091152 2010 INSTALLED NO 7; DesCi1p1ion of Work!'

REPLACEMENT RELIEF VALVE

8. Tests ConducIBt:t HydtOstalic [J Pl19tIfI1stic D Nominal Operating Pressura &!I Exempt [J Other [J Pressura: ____psi Test Temp,; ____ Of' NOTE~ Supplemental sheets In form of Usts:, sketcheS; or drawings may be used, provided (1) size Is 8-412 In; )( 11 in., (2) Information In Items 1 througll6 on this report Is Included on ~ sheet. and (3) each sheells numbered and number of sheets Is recorded al the top of thls form."

FORM NI5-2 (Back)

/

9. Rem8lks Replacement valve change in material Is reconciled through ED 0102798601 APili!& XLliiiIiCiiiIWi W.n;;;&& toJ>>1I/£ICt;;;&

Replacement valVe construction is ASME Sec. III 1968 Edillon. lhru 1970 addenda, code class 2 VT*2 Completed Sat.

Transaction #'5: 35852 CERTIFICATE OF COMPLIANCE I certify that the statements made In the report are cOfTElCt and that this confonns to the requirements of the ASME Code,Section XI.

Type Code Symbol Stamp:

NlA Certificate of Authorlzation No.:

NfA ExpiraHon Date:

NtA Signed:

~0 Asia O. Jerkins, Maintenance Spl. Support Date: -IJ-'11-"-f;'-1{,-----..

cJwMra OWner'ti DesIgnee, T1tls I

CERTIFICATE OF INSERVICE INSPECTION I. the Ullderslgned. holding a valid commission issued by the National Board of Boller and Pressulll VesseilnspecloJS and the Slate or Province 01 <<£9'1=

and employed by....r..r.:=::;:::..-_c;-=-_~___~____~~___...

of have inspected the compenents described In this owners Report during period

..s; to -Ll/4J9I

.and state that to the best of my knowledge and belief. the Own h

jlerforrned examinatIonS and t~ective measures descnbed in this 0Wner's Report in accordance with the requirements of the ASME Code,Section XI.

By signing this certificate neither the Inspector nor his employer makes any warranty. expressed or Implied. concemlng the examinations and corrective measuras described In this Ovmer"s Report. Furlhennore. nellhet the Inspector nor his employer shall be liable in any manner for any peJSOnal Inturv or property damage or a loss of any kind arising from or connected with this Inspection.

~Slgnatu/'8 Oms: ____~~~--------------------

FORM NI8-2 OWNER'S REPORT FOR REPAlRIREPLACEMENT ACTIVITY As Required by the Provisions of the ASME Code,Section XI

1. Owner:

Southern Nuclear Operating Co.

Date:

December 2. 2010 NamtJ 40 Inverness Cenler Parkway; Birmingham, AL 35242 of 2

Addl'lJS8

2. Plant Joseph M. Farley Nuclear Plant (FNP)

Unit FNP Unit 1


~----~~~----~~------

7388 North State Hwy 95; Columbia. AL 36319 Work Order No.~. 1090844201 Ac1dr8ss RepairlRe;JIaC6fT16nt OfUl1nlzatiO~ PO No, Job No, etc.

3. Work Performed By.j FNP MainlenElllce Department Type Code Symbol StamP:

NlA NBmB 7388 North Stale Hwy 95; Columbia. AL 36319 Authorization No.:.

NlA Expiration Date:

NlA 4., ldantiftcallon of System:

Q1P117V0126B* CCW FROM AHR HEATEXCHANGEA 16 RELIEF VALVE (code class 3)

5. (a) Applicable Construction COde:

Section 111

  • 1968 Edition.

thru 1970 Addenda.

NlA Code Case


y;;;;-

(b) Awllcable Edition of Section XIIJsed for Repair/Replacement AcIIvIty.

2001 Addendai 2003

--~~~eM~--

(c) Awlicable section Xl Code Case(s)l:

NlA 6? Identification of Components:

NalIonal Conacted.

ASMECode Name of 0Ittet Year Name of Component Manufacturer Sellal No.

Board Removed. 01' Stamped Manufacturer ldentlllcallon Buill No.

Installed (Yes or No) 1 112" )( 2" Reliel Valve Lonergan 1313434-1-3 NlA QP931675 1994 REMOVED YES 1 1/2" x 2' Relief Vallie Andrsn Grwnwood N99846*00-0010 N/A QP090757 2010 INSTALLED YES

1. Description d Worki REPLACE RELIEF VALVE
8. Tests Conducted:

Hydrostatic []

Pneumatic CJ Nominal Operaling Pressure Iii!I Exempt CJ OtherCJ Pressure:

Test Temp.:

OF


psi NOTE: Supplemental sheets in form of USIS, sketches, OI'drawings may be used, provided (1) size is 8-112 in. x 11 in., (2) Informallon in items 1 through 6 on this report 18 Included on each sheet. and (3) each sheet Is numbered and numbel' d sheets Is recorded at the top of thiS fonn.

FOAM NI$-.2 (Back)

Replacement Valve is ASME Sec. III. 1968 Edition, Ihru 1970 addenda code class 3

Reference:

EDSc'()5-S*0040 for valve applicability VT*2 completed Sat Transaction #'9: 195264 CERTIFICATE OF COMPLIANCE I certify that the statements made In the !9pOrt are correct and that this conforms 10 Ihe requirements of the ASME Code. SectIon Xl.

Type Code Symbol Stamp:

N/A Certlflcate of AUihoriialion No.:

N/A expiration Date:

N/A Signed:

-~

AsIa O. Jerklns, Maintenance Spl. Support

/.,~-,/,,-,-----1 7

Dale: --,

-ownerOf' Owners Designee. 11tm f

"7 CERTIFICATE OF INSERVICE INSPECTION

, I. the undersigned. holding a valid commission Issued by the National Board 01 Boliel and PressUI9 Vessel Inspectors and the State or Province of and employed by

~~~~--

~==~--~----------------------------~

of have Inspected Ihe components described In this 0Wnets Report during the period

()

to

/ ~?',fi>

.and state thalto the best of my knowledge and belief. the Owner s

iformed examinations and tak~easures deSClIbed In thIs Owner's Report in accordance with the n!qUlrementa of the ASME Code. SectIon XI.

By signIng this certlfIoate nellherthe Inspector nor hIs employer makes any warranty. elCJll'&SSed or implied. concerning lhe examinations and corrective measures described In this Owner's Report. Furthermore. neither the Inspector nor his employer shall be liable In any manner for any personallnjuty or property damage or a loss of any kind arising from 01' connected with this Inspection.

Date:

  1. P

FORM NIs..2 OWNER'S REPORT FOR REPAlRIREPLACEMENT ACTIVITY As R=lred Wthe Provisions 01 the ASME Code*.Secllon XI

1. Owner::

Southern Nuclear Operatlhg Co.

Date:

December 1. 2010 Name 40 Inverness Center Parkway; 8imtingham. Al3524%

SIIooI.

of 2

2. Plant:

Joseph M. Farley Nuclear Plant (FNP) unit FNP Unit 1


~~--------~------

7388 North Siale Hwy 95; Columbia. AL 36319 Work Order No.:

1090939901 Address RepaJriReplSC8m8nt Organl';'tIOn PO No. Job No. etC1.;

3. Work Perfomted By:

FNP Maintenance Department Type COde Symbol Stamp:

NlA Nsme 7388 North Stale Hwy 95; Columbia. AL 36319 Authot1zallon No.:

NfA

. NfA

.; ldentlflcalion of System:

TPNS:Q1P16V0208D CTMT COOLER 10 SV'f RETURN RELIEF VLV(code class 2) 5> (a) AwHcabIe ConstruCtiOn COOe:i Section III

  • 1971 Elition. wM/tr"1971 Addenda.

1555&1574 CoOOCase


Y8iU (b) App/kabIa Elitlon of Section XI Used for Repalr/Replaoomeot ActtviIy.

2001 Adderida!'

2003

--~Y;~&U----

(c) Applicable Section XI Code Case(s):

NfA

6. IdentiflcaUon of Components~*

o*

National Con'ected.

ASME Code Name of Other Year Name of Component Manufacturer Serial No.

Board Removed. or Stamped Manufacturer ldentlflcatlon Built No.

Installed (Yes or No)

Relief Valve Lonergan LCT*2O 210130-4*4 Nla FNp*2*51 1975 REMOVED YES Relief Valve Anderson Gmwd C N99904*0().(l()10 N/a QP090757 2010 INSTALLED YES 7*. DescrIption of Worle:

REPLACEMENT RELIEF VALVE

8. Tests Conducted:

Hydrostatic [J Pneumatic [J Nominal Operating Pnlssure ta Exempt [J OUler [J Pressure:

Test Temp,:

'OF


psi NOTE! StJR)lementai sheetS In fonn of IIsls; sketches*. or dtawings may be used, provided (1) size Is 8"1'12 ini x 11 In.. (2) Information In items 1 through 6 on this report Is Included orieach sheet. and (3) each sheet is m.mbered and number of sheets III recorded at the lop of this form.*

FORM NIS.2 (Back) 9, Remarits Replacement valve Is reconclled through EO C051731401 and ASME sec. XI for later code year editionon and addenda

~MI1i/IiiICiII'idIiI.i"16& iiiii2&d RS2!acemenl valve construction is ASME Sec. III 1974 Edition, w/Summer 1975 Addenda code class 2 VT*2 Completed Sal.

Tmnsacllon 11'8: 194912 CEATIFICATE OF COMPLIANCE I cartIfy that the statements made in the report are correct and that Ihf8 conforms to the requirements of Ihe ASME Code.Section XI.

Type Code Symbol Stamp:

N/A Certificate of Authorization No.:

NlA Expiralloo Dale: _____N_/A___.--..

Signed: A '2 <'

Asia O. Jerkins, Maintenance Bpt. Support Date: _--:'~ _______."

/tt._I t

wneror Owfl9f's D88ignse. TitIB CERTIFICATE OF INSERVICE INSPECTION I. the undersigned; hoking a valid commission Issued by the Nallonal Board of BoSar and Pressure Vessel Inspectors and the Srataor ProvInce of

~/+=:

and employed bY,_.......=__a--.:....______________--t of have Inspected the components described In this a' ". l?

10 1//3/i/

. and stale that to lhe best of my knowledge and belief, theh Performed examinations and laken ~tIVe measures described In this Ovmer's Report In accordance with the requirements of the ASME Code, Sec!lon XI.,

By signing this C9fIIficate neither the Inspector nor his empfoyer makes any wananty. 8lCP1'essed or Imp/led., concerning the examinations and COI'I'liIOtlVe measu!8S described In this OWner's Report., Furth&rmore. neither the Inspector nor his employer shall be liable In any manner 'or any personal injury or property damage or a loss of any kind arising 'rom or connected with 1h1S1nspectIon, Date:

)/1ZJ/tl

/,

FORM NI8-2 OWNER'S REPORT FOR REPAIR/REPLACEMENT ACTIVITY As Required by the Provisions of the ASME Code, Sscllon XI Southem Nuclear Operating Co, Dale:

December 6,2010 Name 40 Inverness Center Parkway; Birmingham, Al35242 Sheet:

of 2

Address

2. Pfanl:~

Joseph M. Farley Nuclear Planl (FNP)

Unit:

FNP Unill


~----~N.~s-me-----------------

7388 North Slate Hwy 95; Columbia, AL 36319 Work Order No.: WO 1091054301 RepatdR6pfscement Organization PO No, JoII NO, etc.

3. Work Performed By!'

FNP Maintenance Department Type Code Symbol Stamp:

NJA Nam9 7388 North Slate Hwy 95; Columbia. Al36319 Authorization No.:.

NJA EJqJ!ralion Date:

N/A 4., ldentlflcatlon of System:*

TPNS: Q1E11POO1B IS AHA PUMP (code class 2)

5. (a) Applicable Construction Code:

Section 11/

, 1986 Ecfrtlon;*

No

Addenda, Nla Code Case

~ ---------

(b) Applicable Edition 01 Section XI Used lor RepairlReplacement Activity; 2001 Addenda:

2003 Year (c) AppliCable Section XI Coda Case(sy.

N/A 6; Identification of Components:

National Corrected, ASMECode Name of 0theI' Year Name of Component Manufactuier Serial No.

Board Removed. or Stamped Manufacturer Identification Built No.

Installed (yes or No)

Pump Mach. Seal Ingersoll-Oresser QP950841 1026 QP950841 1996 REMOVED YES Pump Mach. Seal Flow Serve RLSA13079*1 N/A QP09QOO3 2009 INSTALLED YES

~ ~olWooo _____________________

A_E_P_~_C_E_M_E_N_T_M_~_~ S_eal~(~~a_nd ri~~)____________________

a. Tests Conducted:

Hydrostatic []

Pneumatic []

Nominal ()pe!all~ Pressure iii Exampte Other Cl Pressure:

Test Temp.:

OF psi NOTE:Supplementat sheets in form 0# lists, sketcheS, or drawings may be US8(\\;. provided (1) size Is 8*112 Ii\\; x 11 in,; (2)lnformallon in items 1 through 6 on this report Is Included on each sheet, and (3) each sheet is numbered and number 01 sheets is recorded at the top of this form,

FORM NI&-2 (Back) 9., Remarks

.Relerenca: EgulValenct Oel&nTIlnatlon C081191401

. Replacement Seal ASME Sec. 1111986, No Addenda code class 2 VT*2 completed Sat.

Transaction #'$; 193332 CERTIFICATE OF COMPUANCE I certffy that the statements made In the report are correct and that this conforms 10 the requirements of the ASME Code,Section XI.

Type Code Symbol Stamp:

N/A Certlflcate of Authorizallon No.:

NlA Exptratlon Dale:

NiA SIgned:

.~ ~~

....Asia O. Jerklns, Maintenanca Spt, Support Dale: -IJ-,A-',,-,,"'-"-----..

Ow,.......,....,..,ners Designee, rifle

......"1

/~/~L-____-I CERTIFICATE OF INSERVICE INSPECTION I, the undersigned. holding a valid commission Issued by the National BoaJd of Boller and Prassura Vessel Inspectors and the Slate or Province of and employed by c:r

~~~--~------------------------------..

of have Inspected the components described in this Owner's Report during lhe period

?-~

to I/trj!I

' and slate that to tha beSt of my knowledge and belief. the Owner has erlormed examinations and taken borrecHve measures descrlbed In this Owner's Report In accordance with the requirements 01 the ASME Code. Section Xl.

By signing this ceJtiflcate neither the Inspector nor his employer makes any warranty. expressed or Implied. concerning the examinations and correcllve measures described in.thls OWner's Report. Furthermore, neither the Inspector nor his employer shalt be liable In any manner for any personsIlnJury or property damage 01' a loSS of any Idnd arlsIng from or connected with this Inspection.

Date:

--~~~----------------

FORM NI5-2 OWNER'S REPORT FOR REPAIR/REPLACEMENT ACTIVITY As Required by the Provisions of the ASME Code, Sectlon XI

1. Owner:.

Southern Nuclear Operallng Co.

Date; November 8, 2010 Name 40 Inverness Center Parkway; 61rmlngwn, AL 35242 Sheet:

of 2

Address

2. Plant Joseph M. Farley Nuclear Plant (FNP)

Unit:

FNPUnlt 1


M~B-~--------~-------

7388 North Slate Hv.y 95; ColumbIa, AL 36319 Worl<OrderNo.:

E21*1091194201 Address Repair/Replacement otganizauon PO No, Job No, etc,..

3. WorI< Performed By; FNP MaIntenance Department Type Code Symbol Stamp:

NlA Name 7388 North Slate Hwy 95; Columbia, AL 36319 Authorizallon No.:

NlA Expiration Dale:

NlA

4. Identlflcatlon of System:

TPNSt Q1E21SNU8BSS2676 'CHEMICAL VOLUME CONTROL SYSTEM. ASME Class 1

5. (a) Applicable Construction Code:

See RemarkS

,NlA Edition, NlA Addenda.

NlA Code Case

'""YeaI (b) Applicable Edition of Section Xl Used for RepalrlReplacement Activity:

2001 Addenda:

2003 Year (c) AppUcable SectIon Xl COde Case(s}:

N/A

6. IdenUf!catlon of Components:

National Correoted, ASMECOde Name of Other Year Name of COmponent Manufacturer Serial No.

Board Removed,or Stamped Manufacturer Identllicallon Built No.

Installed (Yes or No)

Pivot PIn Pacific-Scientific UNKNOWN NlA QP-1536 1983 Removed NO Load Stud Grinnell QP31295201 NlA QP3129 1989 Installed NO Load Stud Nuts Anvil NUT03701GHBN NlA QP060972 2006 Installed NO

7. Description of Work:

Plivot Pin 1ns1811ed on pipe end was replaced wilt! approved load stud and nuts (MIF 1198787)

8. Tests Conducted:,

Hydrostatic GIl. Pneumatic Ell Nominal Operating Pressure SIl Exempt a Pressure:

Test Temp.:

OF


psi NOTEfSupplemenlal shSels in fonTI of llsis, sketches. or drawfngs may be used. provided (1) size Is 8-112 In. l( 11 In., (2) informa1fon In Items 1 thr0l.916 on this report Is Included on each sheet, and (3) each sheet is numbered and number of sheets Is recorded at the top of this form.

FORM NlSo2 (Back) 9, Remarks SURX)rts Designed 10 AISC.1969 and welded to AWS 01.1-86.

Ref: Transaction 1# 191701 VT*3 Conducted CERTIFICATE OF COMPLIANCE I certify that the statements made In the report are cormet and that this confol'ms to the requirements of the ASME Code, Section Xl.

Type Code Symbol Stamp~.

NlA Certificate of Authorization No.:

NIA 8cplration Date:

N/A Signed:

~'2 Asia O. Jerkins. Sup!. Support Date: --'-/11-';,-'-4'-----1 0Wn8l' or OWners Designe6. TItle CERTIFICATE OF INSEAVICE INSPECTION I, the undersigned, hoIdng a valid commission Issued by ltIe National Board of Boller and Pressure Vessel Inspectors and the State or Province of ~H:: and employed by'"""=""--------~-----~___:___t of

~ cr have Inspected the components described In this OWner's R;p;;;:t(IUfiIlj.;;t;od

¢dpt to -.i/~A/

.and state that to the best of my knowledge and belief. the Owner i;7r)erformed examinations and Jan~e measures described In thIs OYmElr's Report In accordance with the requlrement8 of the ASME Code.Section XI.

By signing this certificate neither the Inspector nor his employer makes any warranty. expressed or Implied. concemlng the examinallons and corrective measures described In this Owner's Report. Furthermore, neith9l' the Inspectof' nor his employer shall be liable In any mlWlElf for any peraonaIlnjury or property damage or a loss of any kind arising from or connected with this Inspectloo.

Date: __~~~~-----------------

FORM NIS-2 OWNER'S REPORT FOR REPAJRJREPlACEMENT ACTIVITY As Required by Ihe Provisions 01 the ASME Code,Section XI 1, Owner:

Southern Nuclear Operating Co.

Dale:

Oecember 6,2010 Name 40 Inverness Center Parkway; Birmingham, AL 35242 Sheet:

of 2

Address

2. Plant:

Joseph M. Farley Nuclear Plant (FNP)

Unit FNP Unit 1


....--------~N~8-~-------------------

731)0 North Siale Hwy 95; Columbia. AL 36319 Work Order No.:

WO 1091199502 Address RepairlRepiacement Organization PO No, Job No, etc.

3. Work Performed By; FNP Maintenance Department Type Code Symbol Stamp:

NIA Nama 7388 Nonh Slate Hwy 95; Columbia, AL 38319 Authorization No.:

NIA Address Expiration Dale:

NIA

4. Identification of System:

TPNS: 01E21P002A 1A CHG PUMP (code class 2)

5. (a) Appffcable Construction Code:

Section III

, 1968 Edillon, No Addenda.

Nla Code Case

~

(b) Applicable Edition of Section XI Used for RapairIReplacement ActMty:

2001 Addenda:

2003 Year (c) Applicable Section )(1 Code Casels):

NIA

6. Idenllficallon of Components; Nallonal Corrected, ASMECode Name of Other Year Name of Component Manufacturer Serial No.

Soard Removed. or Stamped Manufacturer Identification Built No.

Installed (Yes or No)

Charging Pump Casing PadlicPump SIN 46354 Nfa FNP*2 1972 REMOVED YES Charging Pump Casing HydfOAire 5477-01 N/a QP060948 2010 INSTALLED YES

7. Description of Work:

REPLACEMENT Pump Casing

8. Tests Conducted:

Hydrostatic CI Pneumatic 0 Nominal Operating Pressure Ii!!

Exempt 0 Other 0 Pressure:

psi Test Temp.:

OF NOTE: Supplemental sheets in form of /ists, sketches, or drawings may be used. provIded (1) size Is 8*112 in. x 11 in., (2) information in items 1 through 6 on this report is included on each sheet, and (3) each sheet is numbered and number of sheets is recorded at thEltop of this form.

FORM NIS*2 (Back)

9. RemarllS Difference in code/milterial is reconciled through MOe 1091199501 APpl!CiiJJl.. M.anulacturq'f'$ DOIll R.potfs (0 b. a/fBC/i.d Appltcabla pipe sur,ports per 581629 were removed and reinstalled Transaction #'5: 191667 VT*2 completed Sal.: VT*3 completed Sal. on supports; P(e*SerJice Examll1a('on per Manlllatunng Process was Sat CERTIFICATE OF COMPLIANCE rcertify Ihalthe statements made in the report are correct and thaI this conforms to the requirements of the ASME Code. Seelion XI.

Type Code Symlxll Stamp:

NiA Certiftcate of Authorizallon N~

NlA Expiration Dale: _____N_IA____.....

Signed:

. ~ ~~...

Asia O. Jerkins, Maintenance Sp!. Support Date: _c.,l'u!tt~s.+r!t....1/.s......I____-1 O'Imt!ror Ownsr's DesignsB, Title

.7 CERTIFICATE OF INSERVICE INSPECTION have Inspected the components described in this Owner's Report during the p od tJ to*b~

,and state that to the best of my knowledge and belief. the Owner as eriormed Elxamlnalions and tak;?corl& measures described in this Owner's Report In accordance with the requirements of the ASME Coda.Section XI.

By signing this certificate nelt/Jerthe Inspector nor his employer makes any warranty, expressed or implied. conceming the examinations and corrective measures described In this Owner's Report. Furlhermore. neithar the Inspector nor his employer shall be liable in any manner lor any personal Injury or property damage or a loss 01 any kind arising from or connected with this Inspection.

commisstons:*Atz.;.t.;~~~~tl1..e;~:Ui~_______-I Nationsl8oam. State, Province. and Endorsements Data: - __4L_I'-':J:..__________

FORM NI5-2 OWNER'S REPORT FOR REPAIRIREPLACEMENT ACTIVITY As Required by the Provisions of lhe ASME Code.Section XI 1; Owner:

Southern Nuclear Operating Co.

Dale:

December 6. 2010 40 Inverness Center Parkway; Birmingham. AL 35242

Sheet, of 2

--~--- --------

Addmss 2., Plane

. Joseph M, Farley Nuclear Plant (FNP)

Unit FNP Unll1


~--------~~-----------------

7388 North State Hwy 95; Columbia; AL 36319 Wolf< Order NO:i WO 1091223802 Address RBp8ir1R~t Olplinlzatlon PO No. JCI6 No, eta)

3. Work Performed By:

FNP Maintenance Department Type Code Symbol Stamp:

NJA Narrt6

.7388 North Stale.Hwy 95; Columbia, AL 36319 Authoitmllon No;:

NJA Expiration Dale:

NlA

~. Identification of System:

TPNS: 01P16PIPEHCCDZD CTMT COOLER INLET FLEXIBLE UNE (code clas!!:3).

5., (8) Applicable Construction Code:

Section H1

  • 1980 Edition. thru Sum 1982 Addenda, N*192-2 Code case

~

(h) ApplIcable Edition of Sectkln XI Used for RepalrfReplacement ActlVtty:

2001 Addenda:

2003 Year (c) Applicable SeCtIon XI COOe Case(s);

NlA

6. Identification of components:

National Corrected.

ASMECode Nameo!

Other Yeal Name of Component Manufacturer Serial No.

Board Removed. or Stamped Manufacturer Identification Built No.

Installed (Yes or No)

Braided Flex Hose ali<er Hannifln COil 86405-1 N/A OP*I845 1988 REMOVED YES Braided Flax Hose Senior Flexonics TCH674 NlA QP090802 2010 INSTALLED YES 7,* Desclfptlon of Work:

REPLACEMENT OF FLEX HOSE

8. Tests Conducted:

Hydrosta/lc [].

PneumallC C Nominal Operating Pressure Ii!

Exel'TlJlt []

Test Temp.; ____ oF OIher[]

Pressure:

pst NOTE: Supplemental sheets ItI form ellists, skelches. or drawings may be used; provided (1) size Is 8-112 In. )( 11 iii** (2) Information In Items 1 throug, 6 on this report Is Included on each sheet,.and (3) each sheet Is numbered and number el sheets Is recorded al the top of this form.

FORM NIS-2 (Back)

9. Remarks Temp; Mod. Per WO 109.1 ~23801 installed Blind Flan!! in 1R22 Braided Hose PliOI' to the Installation of Temp. Mod. Was QP*1845 VT-2 cOl'npleled Sat.

Transaction #'$:'198572 CERTIFICATE OF COMPliANCE I certify that the statemenla made in the report are correct and that this conforms to the raqulrements of the ASME Code,Section XI.

Type Code Symbol Stamp:

N/A Certificate 01 Authorlzallon No.:

NlA expiration Date:

N/A Signed:

~'---::I Asia O. Jerkins. Maintenance Spt. Support Af-~;,-,-,,-----1 Date: --,

-UWIl6I'orOWners DssIgnee. nus CERTIFICATE OF INSERVICE INSPECTION I. the undersigned. holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State 01 Province of ~

and employed bv-IJI.50::::;:;;;.._...;;;;.t.-_______________-I of

~] ~

have Inspected the components described In this Owner's Report during tile period/

05:Id?

to

.J..!~/;/

.and stale that to the best of my knowledge and belief. t;;;;-~rformed examinations and taken £~;;;m~asures described In this Owner's Report in accordance wiItIlhe requirements ollhe ASME Code.Section XI.

By signing IflIs certJllcate neither the Inspector nor his employer makes any warranty. elqll'6ssed or implied. concerning the examinations and corrective measures desCribed In this Owner's Report. Furthermore. neithar the Inspector nor his employer shafl be liable in any manner for any personal inJury or property damage or a loss of any kind arising Irom or connected Yoith this inspec!lon.

~: --~~~~----------------

FORM NI8-2 OWNER'S REPORT FOR AEPAlRIREPLACEMENT ACTIVITY As A?lred, the ProvIsions of \\he ASME Code, SectIon XI

1. Owner:

Southern Nuclear Operating Co.

Date:.

December 2. 2010 NatT16 40 Inverness Center Parkway; Birmingham. AL 85242 Sheet of 2

Addff1SS 2: Plant Joseph M. Farley Nuclear Plant (FNP)

Unlr.

FNP Unl11


~~------~Nwoo~------~~-----

7388 North State Hwy 95; Columbia. AL 36319 Work Order No.:.

1091290901 Ar:ldtsss R9PaJtIRepiacemsnt Organlzatfon PO No, Job No, etc.

3. Work Pedonned By:

. FNP Maintenance Department..

Type Code Symbof SIa.Inpc NlA Nsme*

7388 North State Hwy 95; Columbla. Al36319 Authoriza\\lOO No~:

NlA ElqJ/ralion Date:*

NlA

4. ldentlllcailon Of Syslem~.

Q1E21V412A.cHG PUMP AECIAC TO 1A RCS HOT lEG TEST CONN ROOT (code class 1) 5, (a) Applicable Construction Code:.

Section III

Addenda, N1A CodeGase Teat (b) ApplIcable Edllion of SecUon XI Used for Repair/Replacement AotMty:'

2001 A~:

2003 Yesr (0) Applicable SGCllon XI Code Case(s).

NlA

6. ldentlficallon of Components:

NaUonaJ Corrected.

ASMECocIe Nemeot Other Year Name of Component Manufacturer SerIaJ Ne.

Board Removed,or Stamped Manufacturer IdenHflcalion Built No.

IIl$IaIIed (Yes or No)

Bonnet Kerotest UP*99-15-8-( 1 )

N/A FNP295 1974 REMOVED YES Bonnet Flowserve 3J19*1 NJA QP090864 2009 INSTALLED YES REPLACED VALVE BONNET 8, Tests Conducted:

Hydrostalfc []

Pneumatic []

Exempt []

Other[J


psi Test Temp.:

OF NOTE: Supplemental sheels In form Of "&fa. sketches. or drawfngs may be used. provided (1) size is 8-11210. x 11*

In.* (2) lnfonnallon 10 items 1 through 6 on thiS repOrt Is Included on each sheet,.and (3) each sheet is numbered and number of sheets Is recorded allhe top of this fonn.

FORM NI5-2 (Back)

9. Rem8il<s Aaplacement Bonnet code is ASME Sac. III. 1971.Wllh W'71 code class 1 VT*2 completed Sat Transaction Ii for new valve Bonnet 196956 CERTIFICATE OF COMPLIANCE I certify that the statements made In Ifle report are correct and that this conforms to the requirements of the ASME Code, SectIoIl XI.

Type Code Symbol Stamp:

N/A Certificate of Authorization No.:

NlA Expiration Date:

N/A SIgned:

.Asia O. Jerkins. Maintenance Spt, Support 7."'7 Date: --,-,1-'1'1h.-#"......;;~----I C1tfIItT6r or Owner's Designee. TItle CERTIFICATE OF INSERVICE INSPECTION I. tha undersigned. holding a valid commission Issued by the Natlonal Board of Boiler and Pressure Vesse/lnspectors and !he State 01' Province 01 and employed by 0-1

~~~~~--------------------------~

of have Inspected the components described in this to 103/11

,andstalalhatto the best of my knowledge and belief. -the-Owne-"';:r:;'has~~oO::;rm"ed-e-xam-'-na-tJ-on-s and taken 60rreclJve measures described In this OWner's Report In accordance with the requirements of Iha ASME Code. Sootion XI.

8y signing this certtlicate neither the Inspector nor his employer makes any warranty. expressed or implied. concemIng the examinations and cotrecllve measures described In this OWner's Report. Furthermore. neither the Inspector nor his employer shall be liable In any manner for any personal injury or property damage or a loss of any klnd arising from or connected with this inspecUon.

~$Slgnstul8 D

e t

~

~

~

FORM NI5-2 OWNER'S REPORT FOR REPAlRlREPLACEMENT ACTIVITY As Requimd by the Provisions of the. ASME Code. Sectlon XI

1. Owner::

Southem Nuclear Operating Co.

Date:

December 2. 2010

--~!~.---------N~ruoo--~~~~--------

40 Inverness Center Parkway: Birmingham. Al35242 Sheet' 01 2

Addmss

2. Plant

.JOseph M. Farley Nuclear Plant (FNP)

Unit:

FNP Unit 1


~N~mng---*---------------

7388 North Stale Hwy95; Columbia. Al36319 Work Order No;;, 1091291301.

Addf8ss RepsirlRepiacement Organization PO NO. Job No. sic;..

3. Work Performed Byr FNP Maintanance Department Type Code Symbol Stamp:

NJA NalTl9 7388 North Stale Hwy95~ Columbia. Al 36319 Authorization No.:

NfA expiration Dalel N1A

4. Identification of System, Q1E21V412D -CHG PUMP RECIRG TO 1A ReS HOT LEG TEST CONN ISO (code class 1)
5. (a) Applicable Construction Code:

Section III Addenda.

N/A CodeCasa YSSr (b) Applicable EdlilOn of Sectfon XI Used for RepaIrlReplacement ActMty:

2001 Addenda::*

2003 YeSt (e) Applicable Section XI Code case(s):

NlA

6. ldentUlcatlon of COmponents:

National Corrected, ASMECode Name of Other Year Name of Component Manufacturer Serial No.

Board Removed, or Stamped Manufacturer ldenttftcatlon Built No.

Installed (Yes or No)

Bon nat Kerotest UP*99*15-3*(1)

N/A FNP295 1974 REMOVED YES Bonnet Flowserve 3J19-2 NlA QP090364 2009 INSTALLED YES 7.' Description of Wodc.

REPLACED VALVE BONNET

8. TesIs Conductedl Hydrostatic 0 Nominal Operatlng Pressure Ea Exempt [J Other [J Test Temp.:

"F


psi NOTE! SI4lPlemMIai sheets In form of Hsls. sketches. ordra~may be used. provided (1) size is 8-:112 In. x 1t in.. (2) Information in items 1 through 6 on this report Is Included on each sheet. and (3) each sheet Is numbered and number of sheets Is recorded at the lop of 1Il1s form.

FORM NI5-a (Back)

9. Remari aniiC&ld Relief valve is reconiled through ED 1103283101 Replacement of Studs are per ASME Section III, NC 1983 no addenda class 1 Aeplacement of Nuts are per ASME Section III. NC 1989 no addenda class 2 FNP Piping Specification SSll0902 allows a construction Code of ASME Section III. 1971 Edition thru 2000 Edillon Addenda The specification require the material to be SA 194 Gr. 2H or SA 194 Gr. 7 for studs and nuts VT*2 completed Sal.

Transaction /I's: 195333, 198328 CERTIFICATE OF COMPLIANCE I certify that the statements made in the report are correct and that this conforms 10 the requiremenls of the ASME Code,Section XI.

Type Code Symbol Stamp:

N/A Certificate of Authorization No.:

N/A Explral/on Dale: _____

N/_A____-I Signed:

/.--,

Asia O. Jerkins. Maintenance Spt, Support Date:

,faitr

-+-'"

(,~'------I O~or Owner's Designee, Title CERTIFICATE OF INSEAVICE INSPECTION I, the undersigned, holding a valid commission Issued by the National Board of Boller and Pressure Vessel Inspectors and the State or Province 01

~t1:: and employed by..,t:l._IoL._..-=:::r....... __--:__~_:__----_:____:__:-:___I of

~

if have Inspected the components described in this Owner's R;;;;tdUIiflQlhi-6eriod

...~OA to

,k/;{)

,and state that to the best of my knowledge and belief, the Owner has~rmed examinations and taken~live measures described in this Owner's Report In accordance with the requirements of the ASME Code,Section XI.

By signing this cartl/icate neither the Inspector nor his employer makes any warranty, expressed or Implied, conceming the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shaD be liable in any manner for any personalln]ury or property damage or a loss of any kind arising from or connected wifh this Inspectton.

~Signatufe Date: ---;F.....~.:...---------

FORM.NI8-2 OWNER'S REPORT FOR REPAlRlREPLACEMENT ACTIVITY As ReqUired by the Provisklns of the ASME COde,Section XI

1. Owner.

Southam Nuclear Operatlng Co.

Date:

October 21, 2010 Name 40 Inverness Center Parkway; Bhmlngham, Al 35242 Sheet of 2

Address

2. Plant:

Joseph M. Farley Nuclear Plant (FNP)

Unit:

FNP Unit 1


~--~------N~wne------------------

7388 North Slate Hwy 95; Columbia, Al36319 Work Order No.:

Nl1* 1101166902 Addmss Repair/Replacement Organizstlon PO No, Job No, elC;.

3. Work Performed By:

FNP Maintenance Department Type Code SymbOl Stamp:

NlA Name 7388 North Slate Hwy 95; Columbia, AL 36319 AuthoI1zaIion No.:

NlA Addmss Expiration Date:

NlA

4. IdenIlficatkln of System:

TPNS: Q1N11SNUBBMSR221 MAIN STEAM SYSTEM, ASME CLASS 2

5. (a) Applicable Conslruction Code:

See Remarks NlA Edition, NlA Addenda.

NlA Code Case y;;;-

(b) Applicable Edltion of SectIon XI Used lor RepalrlReplacement AcIIvlty:

2001 Addenda:

2003 Year (e) Applicable Section XI Code Case(s):

NlA

6. Identification ot Components:

NatJonal Corrected, ASMECOde Name of Other Yeer Name of Component Manufacturer Serial No.

Board Removed, or Stamped Manufacturer IderttlfIeation BUilt No.

Installed (Yes or No)

Hydraulic Snubber ITT GRINNElL 17011 NlA FNP*222 1972 Removed NO ControlBloek Hydraulic Snubber ANVIL 38139 NlA OP100486 2010 Installed NO UpgradeKlt

7. Oescripllon of Woo\\::

Snubber MSR*221 was replaced as 8 scheduled upgrade Ref: Transaction tt 191731

8. Tesls Conducted:

Hydrostatic gjl Pneumatic GB1 NomInal OperatIng Pressure ~

Test Tamp.: ____ P'F Pressure: ----psi NOTE: Supplemental sheets In form of 11s1B, sketches. ordl'awklgs may be used. provided (1) slzels 8-112 In. x 11 In., (2) Information In Ilems 1 through 6 on this report Is Included on each sheet. and (3) each sheet Is numbered and number of sheets is recooIed at the top of thls form.

FORM NI8-2 (Back)

9. Aemarl<s Supports Designed to AISC-1969 and welded to AWS 01.1-86.

Reference equivalancy determination C092165101 Ref: Transaction # 191731 VT-3 Conducted CERTIACATEOFCOMPUANCE I certify that the statements made In !he report are correct and that !his conforms to the requlrements of the ASME Code, SecIIM Xl.

Type Code SymboJ Stamp:

NlA CeI1IIIcate of Authorlzatloo No.:

NlA Expiration Date:

NlA Signed:

~::2. <<"

Asia (); JeJldns. Supt StJPPClI1 Date: --,-rj-.". ~-,,-,----""'

Owner Of" Owners DesIgnee, TIlle CERTIACATE OF INSEAVICE INSPECTION I, the undersigned. holding a valid commission issued by the Nallonal Board of Boller and Pressure Vessel Inspectors and the Slate or Province of ~

and employed by.....u.::;.-~....;;;..t::::T'"'--_____________-...

of

~~

have Inspected the components described In this Owner's Report during the period ~ Mho to sfy.4

'and state lhat 10 the best of my knowledge and belief, the Ownerfui7performed examlnallons and taken co;;:;;{ive measures descllbed In this Owner's Report In accordanc& \\\\flh the requirements of the ASME Code,Section XI.

By signing this certificate neither the Inspector nor IVs employer makes any warramy, expressed or Implied, concemIng !he 6lUVTlinatlons and corrective measures described In this Owners Report. Furthermore, neither the Inspector nor his employer shall be liable In any manner for any personallojury or property damage or a loss of any Idnd arlslng from or connooted wItIllhfs Inspection.,

Date:

!¥U

FORM NI5-2 OWNER'S REPORT FOR REPAlRIREPLACEMENT ACTIVITY As Required by lhe Provisions of lhe ASME Code.Section XI

1. Ov'iner:

SOUIhem Nuclear Operating CO.

Date:

10/1&2010 Name 40 tn\\/efTle5S Center Parkway: Blrmi1gt1am. AL 35242 Sheet:

a 2

Address

2. Plant:

Joseph M. Farley Nuclear Plant (FNP)

Unit FNPUnil1


~----~N.~a-me--------~-------

7388 North State Hwy 95; Columbia, Al36319 WorkOtderNo.:

N12*1101192101 Address RepafrlRep/acement Orgsn/zatlan PO No. Job No, etc,

3. Worl< Perlonned By.

FNP Malntenance Department T~ Code Symbol Stamp:

NlA Neme 7388 North Slate Hwy 95; Columbia, Al36319 AU1hortzatkln No.:

NlA ExpIraIIonDate:

NlA

4. IdEllIlflcalloo of System;.

TPNS:Q1N12SNUBBASH386X AUXILIARY STEAM SYSTEM. ASME CLASS 3

5. (a) AppIlcab!e Construction Code:

See Remarks

  • NlA Edition.

NlA

Addenda, NlA Code Case Yeal (b) Applicable editIOn 01 Sectloo XI Used for AepalrlRepIa;ement ActMty.:

2001 Addenda:

2003 Year (e) Applicable SecIfon XI Code case(s):

N/A

6. Identification of Oxnponents:

Corrected.

ASMECoda Narnea NatklnaI Olher Year Name of Ccmponent Manufacturer Serial No.

Removed, or Stamped Manufacturer Board No.

IdentifICation Built Installed (Vas or No)

Hydraulic Snubber ITT GRINNELL 11725 NlA FNP*2*29 19n Rema\\led NO Hydraulic Snubber ANVIL 3nV N/A QP09069B 2009 Inslalled NO

7. Description of Work:

SnubberASH*386X was replaced as a scheduled upgrade Ref: Transection # 191795

8. Tests Conducted:

Exempt..

Other 'II Pressure:

Test Temp.:

OF


pSI NOTE: SUpplemental sheets In rorm of liSts. sketches. or drawings maybe used. proIIided {1) size Is 8-1121n.)( 11111.*

(2) Information In Items 1through 6 on lhls report Is Included on each sheet. and (3) each sheet Is nllTlbered and number ~ sheela IS recorded at the top of !his form.

FORM NI8-2 (Back)

9. Remarks Supports Designed to AI5C-1 009 and welded to AWS 01.1-86, Reference equivalency delemtfnation C091569201 EO Ref: Transacllon /I 191795 vr*3 Conducted CERTIFICATE OF COMPUANCE I certffy that the statements made In the raport are correct and that this coolorms to the requlrema'lts of the ASME Code.Section XI.

Type Code S)mboI Stamp:

NlA Certillcats of AUIhQrizaIIon No.:

NlA.

ElqlIratIoo Date:

NlA Signed:

_ ~i7="..

Asia O. Jerklns. Supt. SlWQrt Dale: I J., I" OM'IIN~S Designee, TiIJIi

,;.£...-------1

.t..f-CERTIFICATE OF INSERVICE INSPECTION I. the UIlderSIgIed, holding a vaIld CMlmlsslOn issued by 111& NaIlonaI BoalO of BolI!Ir and Presstn VesseilnspectDrs and the Slate or Province of

~/t CT and employed by-<.>=____...._______________-t of

~

Cd.

ad the canponenl9 descrbed In this Own91's Report dumgthe perk;6 gy~o to

  • and slate that to the best of my knowledge and belief, the Owner ;

P41ff0l1ilecJ examinations <W1d taken;;;;t;;.~~;;;;;;=-;;::;;:;u:~

Owner's Report In oocorttance with the requirements of the ASME Code. Sectlon XI.

By SVifnQ this ceftiflcate neither the Inspector nor his employer makes any warranty. expressed or implied. concerning the examInatiOns and correctlw measures descrbed In this Owner's Report. Ft.uthermore, neither the Inspector nor his emr:*lYar shal be nabla In 81l'J manner lor any personailniLIY or proper1y damage or a loss of any kind arising from or coonected with this Inspec1loo.

Dme: ____~~~~+---__----------

FORM NI8-2 OWNER'S REPORT FOR REPAlRlREPLACEMENT ACTIVITY As Requll9d by the ProvfeJons of the ASME Code.Section XI

1. Owner.

Southem Nuclear Operating Co.

Date::

December 6.2010 Nama 40 Inverness Center Parkway; Birmingham, AL 35242 Sheet cl 2

2*. Plant:

Joseph M. FarleV Nuclear Plant (FNP)

Unit*:

FNP Unit 1


~N~a-ms~*----------------

7388 NDrth Slate Hwy 95; Columbia, AL36319

. Work OrderN().: WO 1101205502 Address RapairlReplac6I7!Snt Organization PO No.*Job No. etc..

3. Work Perfooned By:

FNP Maintenance Department Type Code Symbol StamP:;

NlA Nama 7388 North State Hwy 95: ColUmbia, AL36319 Authorization No.:

. N/A Address Expiration Date;-.

N/A 4*. idenlfflcatlon of System; TPNS: 01P16V2530 (OIP1MfBC*39) SW Return from 10 CTMT HOR Drain (code class 3) 5, (a) Applicable Construction Codal Section III

,1971 EtItlon, thru 2000 Addenda.

Nla Code Case

~

--~------

(b) Applicable EdIIIon of Section XI Used for RepalrlAeplacement Activity; 2001 Addenda!

Yeer (c) Applicable Section Xl Code Case(s):'

NlA

6. Identification or Components:

National Corrected.

ASME Code Other Year Name of Component Name 0' Manufacluref Serial No.

Boafd Removed. or Stamped Manufacturer ldentillcatian Built No.

Installed (Yes or No) 2" Seckolet WFI HT#4949ANB Nla QPl00316 2009 INSTAllED NO 2" X I" Reducing Insert CapitOl Mig Comp.

HTI#19H N/a QPOOO344 1992 INSTALLED NO

7. Description of Work:

INSTALLATION of SOckQlet and Reducer

8. Tests Conducted:'

Hydrostatic [J Pneumatic [J Nominal Operating Pressure iI Exempt [J Test Temp.~.____"F Other.[J Pressure: ----psi NOTE. Supplemental sheets In form or lists; sketChes, Of drawfngs may be used, provided (1) size Is Q..112 il1.;.lC 11 in** (2) Information in items 1 through 6 on this report is Included on each sheel, and (3) each sheet Is numbered and numbel' of sheets Is recorded at the top of this form.

FORM NIS-2 (Back) 9*. Remarks Installed Sockolel. reducer I~ ASME sec. III, 1989 Edition FNP Piping Speciflcation S5110902 allows a construction Code 01 ASME Section III, 1971 Edillon Ihru 2000 Edition Addenda VT*2 compleled Sat.

CERTIFICATE OF COMPLIANCE I certify that the stalemenlS made In the report 819 correct and thallhls conforms 10 the requlremenlS of the ASME Code, Section Xl.

Type Code Symbol Stamp:

N/A Certillcale 01 Authoriza1iOn No.:

NJA expiration Dale:

NJA Signed:

~.,

Asia O. Jerkins, Maintenance Spl. Support Date:

1/'"I"

-i~r-=------I

""'e!I1i8f or OWners DesIgnee. Title CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, hoking 8 valid commission issued by the NatIonal Board ot Boiler and Pressure Vessel Inspectors and the Stale 01' Province of

~(A: and employed by...&!i~~~______________-I of

~

c:r::

have Inspected the components described in this Owner's Report during ih;(periOd

.&Y~

10.J. k 1.

.and state thet 10

!he best of my knowledge and belief. the Owner ~p;;;;&med examinations and taka;;~ measut'es described In this Ownlill's Report In accordance with the requirements ollhe ASME Code.Section XI.

By signing this certificate neither the Inspector nor his employer makes any warranty. expressed or Implied. concerning the examinations and corrective measures described In this Own91's Report. Furthermore. neither the Inspector nor hiS employer shall be liable In any manner for any personallnlury or property damage or 8 loss of any kind arising from or connected with this Inspection.

Dme: __~~~~_____________________

FORM NI5-2 OWNER'S REPORT FOR REPAIR/REPLACEMENT ACTIVITY As Required by thaProvislons ofthe ASME Code. Sootlon XI

1. Owner.

Southern Nuclear OpeJallhg Co.

Dale; January 4. 2011 NBft'19 40 Inverness Cenler Parl<way; Birmingham. AL 35242 Sheet:'

of 2

2. Plant Joseph M. Farley Nuclear Plant (FNP)

Unit FNP Unit 1

--"'--......;-~-~N..,..am-9..--------*

7388 North Siale Hwy 95; Columbia. AL 36319 Work Order No;;

WO 1101631601 Address RepalriReplacement OrganizatiOn PO No, Job No. 811::;

3. Work Performed By; FNP Maintenance Department Type Code Symbol Stamp:

NlA NBft'19 7388 North State Hwy 95; Co/umbla, AL 36319 Authorizallon No.:

NJA ElCpiJallon Dat&~

NlA

.4~ Identification of System:

TPNS ~ 01 P16F0502C 10 SERVICE WATER PUMP DISCHARGE EXPANSION JOINT (code class 3)

5.: (a) Applicable Construction Code:

Section III

  • 1971 Edillon, 1971 WInter Addenda, 1177*7 & 1330*3 CodeCase

-y;;

(b) ApplIcable Edition of S&ctIon XI Used for Aepair/RepIac&men1 Actlvityl 2001 2003 Yesr (e) Applicable Section XI Code Case(s):

NlA

6. Identification of Components:

National Corrected, ASMECode Name of Other Year Name 01 Component Manufacturer Serial No.

Board Removed. or Stamped Manufacturer ldenliflcatlon Built No.

Installed (YesOf' No)

Expansion Joint Tube Turns 46185 N/A FNp*359 1973 REMOVED YES Expansi()n Joint

~enlot OpeJation. In K77500*1*3 N/A QPOS0649 2008 INSTALLED YES

7. Desclipllon of WOrk:

REPLACEMENT OF SW EXPANSION JOINT

8. Tests Conducted<

Hydrostatic []

Pneumatic [J Nominal Operating Pressure B ElC8mpt []

r Other []

Test Tamp.:c ____ ~F Pressur~* ----psi NOTE: Supplemental sheets In form of Itsts. sketcnes. or dJawings may be used, provided (1) size Is 8-11210. x 11 In., (2) Information In Items 1 through 6 on this report Is Included on each sheet.. and (3) each sheells numbered and number of sheels is recorded alllle lop of this 'oon.

FORM Nt$-2 (Back)

9. Remarks Equivalency Delennlnalion ED1101631601 reconciles the differences In fonn, fit. and function

~ AZtiiUi.ICliM1ilWtm;;;&!(IS; iiI&&J Replacement ElqlaIlsion Joint Is of ASME Sec. III. 1980 Edition thru Summer 1982 Addenda with Code Csse N*369 code class 3 VT*2 Comp. Sat Transaction # 1st 185881 CERTIFICATE OF COMPLIANCE I certify mat the statements made in the report are correct and that this conforms to the requlrements of lhe ASME Code.Section XI.

Type Code Symbol Slamp:

N/A Certificate of Authori.zatlon No.:

N/A Expiration Date:

NlA Signed:

~ --:J...

Asia O. Jelkins, Maintenance Spl. Support Dale: rl-'1/-",------t

~~~~---------t oWrrtfforOwnst's Designee. TItle

(

CEATIFICATE OF INSERVIGE INSPECTION I, the undersigned, holding a valid commission Issued by the National Board 01 Boiler and Pressure Vessel Inspectors and the Stale or Province 01

~IJ-and employed by_*~i!:IioI:....-._.=::t__~____----_:_-:__~_:_:"'_I of have Inspected the components described In this Owner's Report during the tiod

()

to

-'./I?'fll

.. and stale that to the best of my knowledge and belief. the Owner s

rformed examinationS and take~;;;;;measures described In this Owner's RepOrt in accordance with the requirements of the ASME Code.Section XI.

By signing this certilicale neither the Inspector nor his employel' makes any warranty, expressed or Implied. concerning the examinations and corrective measures described in this Owner's Report. Furthermore. neilher the Inspector nor his employer shall be liable in any manner for any personal Injury or property damage or a loss of any kind arising from or connected with this inspection.

Date:


~~~~-----------------

FORM NIs..2 OWNER'S REPORT FOR REPAIR/REPLACEMENT ACTIVITY As Requlred&y the Provisions 01 tile ASME Code,Section XI.

1. Owner.

Southern Nuclear Operating COi'.

Date:

December 1. 2010 Nams 40 Inverness Cenfer Parkway; BirmIngham. AL 35242 Sheet of 2

Addrsss

2. Plant:

Joseph M. Farley Nuclear Plant (FNP)

Unit:

FNP Unit 1


~--~N.~ams--------~~------

7388 North State Hwy 95; Columbia. AL 36319 Wol1< Order No.,' 1102430901 RepaJrlRePltfCeTTl6nt Organization PO No. Job No, etc.

3. Work Performed By:'

FNP Maintenance Department Type Code Symbol Stampr NlA

--w---~N.~tf-me------~---------

~88 North State Hwy 95: Columbia. AL 36319 Authorizatlon No.:

NlA Expiration Date:

N/A 4, Identlflca!lon of System:

01P16VOO5F:'lC CCW HX SW INLET TUBE SIDE DRN (code class 3)

5. (a) AppIlcabfa ConsIruc:tlon Code:

Section III

Addenda, NlA Code Case y;s,.-

(b) ApplICable EcItIOn 01 SectIon XI Used for RepairlRep!acement Activity:

2001 Addenda:

2003 Year (e) ApplICable Section XI Code Case(s):

N/A

6. IdentlfrcatiOn of Componenl~

Name of Component Name of Manufaclurer Manufacturer Serial No.

Natlooal Board No.

Other Identification Year Built Corrected.

Removed. or Installed ASMECode Stamped (Yes or No) 2" Valve (Bonnel)

BNL Ind.

93A*1 N/A OP()1017S 2008 REMOVED YES Disc BNL Ind.

129A NlA QP010175 2008 REMOVED Body BNL Ind.

126A*2 N/A QP070175 2008 REMOVED 2' Valve BNL Ind.

A070a09-1*31 N/A QP07017S 2008 INSTALLED YES

7. Description of Work:

REPLACED VALVE

8. Tests Conducted; Hydrostatic [J Pneumatic []

Nominal OPeratIng PI'8SSUr8 Ii!

Exampt[J PI'8SSUI'8:

psi Test Temp,: _____OF NOTE: Supplemental sheeIs In form 011lsl5. sketches,Ofdm.wIilgs may be used. provided (1) size Is 8-1.12 Ii'l. x 11 in" (2) Inlonnation In items 1 through 6 on It!Is report Is Included on each sileet. and (3) each sheet is numbered and number of sheets is recorded at the top of this form,.

FORM NIS:-2 (Back)

9. Remarks Replacement Valve is ASME Sec. III. Winter 1971 w/w'1971 edllfon, Md para NB6111.1C of w' 72 class 3 Transaction #: 196419 VT*2 Completed Sal.

CERTIFICATE OF COMPlIANCE I certify that the statements mad91n Ih9 report are correct and that this conforms 10 the requirements of the ASME Code.Section XI.

~/~~~--------~

Type Code Symbol Stamp:

NlA Cel1lfk:ate of Authorization No.:

N/A Expiration Date: _____Nl...A___--I Signed:

~~ /

Asia O. Jerkins, Maintenance Spt. Support Date:

f IfII,

_"'~nsror OwtW's Designee. rills CERTIFICATE OF INSERVICE iNSPECTION

i. the undersigned, holding a valid commission Issued by the Nallonal Board of Boller and Pressure VessellnspectOl'S and the State or Province of ~t.andemptoyad by...;...r....;;;.::.=..__""-______________--I of

~ cz:

have inspected the components described in this Owner's Report durirlQiife period

--::rh...3.b,0 to

~I!/

'and slate that to the best of my knowledge and belief, the ow;r~ormed examinations and taKan c6rrective measures described In this Ovwlers Report in accordance with the requirements of the ASME Code. Section Xl.

By signing this certificate neither the Inspector nor his employer makes any warranty. expressed or Implied. concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner lor any pefSOflaIlnjury or property damage or a loss 01 any kind arISIng from or COI1fI6CIed with this Inspec!kln.

Date: --4~~..:..I.----------

FORM NI8-2 OWNER'S REPORT FOR REPAlRlAEPLACEMENT ACTIVITY As Required by the Provisions of the ASME Code, SectIOn XI

1. owner:

SoU!hem Nuclear Operating Co.

Dale:

1013012010 Nams 4() Inverness Center ParkWay; Blnnlnsttamj AL 35242 Sheet of 2

Addmss

2. Plant:

Joseph M. Farley Nuclear Plant (FNP)

Unit FNP Unit 1


~----Mmw~~-------------

7388 North State Hwy95: Columbia, AL 36319 Work Order No.: 613-1103111801 Address RejjliJrlRsplacsment Organizalion PO No, Job No, me.

3. Work Performed By:

FNP Malnl<<lance OeparIment Type Code Symbol Stamp:

N/A Name 7388 North State Hwy 95; CoIumbfa, AL 36319 Au1hOrization No.:

NlA Address E.xp!mtlon Data:

NJA

4. Identification of System:

TPNS: Qt613SNUBBRCR11 REACTOR COOLANT SYSTEM. ASME CLASS 1

5. (a) Applicable Construction Code:

See Remarks

,NlA Edltlon, NlA

Addenda, NJA Code Case

~ --------

(b) ApplJcable EdlUon of SectIon XI USed for RepaJrlAeplacement ActIvity:

2001 Addenda:

2003 Year (e) Applicable Section XI Code Case{s):

NlA

6. Identlflcatlon of Components:

National Correctad, ASMECode Name of Other Year Name of Component Manufacturer sertal No.

Board Removed,or Stamped Manufacturer IdenlJflcatlon Buill No.

Installed (Yes or No)

Hydraulic Snubber ITT GRINNELL 13763 NlA FNP*222 1975 Removed NO Hydraulic Snubber ANVIL 37717 NlA QP090698 2009 Installed NO

7. Descrlptlon of Work:

Snubber RC-A11 was raplaced as a scheduled upgmde RetTransactlon 1# 197313 8" TeslS Conducted:.

Hydrostatic mJ' Pneumatic §JI Nominal Opemtlng Pressure a.tJ.

Exempt G1I Pressure:

psi Test Temp.:

OF NOTEo Supp/emenu. sheets In fonn of lists, sketd1es, or drawlflf:J$ may be used, provided (1) size is 8-1f2 In. x 11 in** (2) Infonnallon in items 1 through 6 on this report Is included on each sheet. and (3) each sheet is numbered and number of sheets Is recorded al the top of this form.

FORM NIS.2 (Back)

9. Remarlcs Supporta Designed to AISC*1969 and welded to AWS 01.1*86.

Reference eqillvalency determination C092313201 Ref: Transactlon #197313 VT-3 Conducted CERTlACATE OF COMPLIANCE I certify !hat the statements made In the report are correct and that this conforms to the requIrements of the ASME Code, Sedfon XL Type Code Symbol Stamp; NlA CerUllcala of Authorization No.:

N1A expiration Date:

NlA Signed:

.A~'"

Date: -.:."J~1J,

..../;.a"I AsIaO.Jed<Ins.Supt.Support

_____-I O~8r'$ Designee, T1tJ8 CERTIFICATE OF INSERVICE INSPECTION I. the undersigned. holding a valid commission Issued by the National Board of Boiler and Pressure Vessel Inspectors and the Smteor Province of ~

anti employed by--,~::.&_.-;:;;_________________~

of

.'.?

have Inspected the components described In Ihls Owner's Aeportdurlng the peri

___-.l~'I..~.,.~.~___ to ~ *and state that to the bast of my knowledge and belief, the O'Mler has rf examinations and takEH7"correclive measures described In this Owner's Report in accordance with the requirements of the ASME Code,Section XI.

By Signing this certificate neither the Inspector nor his employer makes any warranty. expressed or Implied. concerning the examinations and corrective measures described In this Owner's Report. Fwthermore, neither the Inspector nor his employer shall be nable In any manner for any personallnju/y or propertY damage or a loss of any kind arising from or connected with this inspection; nspectots SIgnature Oef~ ____~~~~_______________

FORM NI5-2 OWNER'S REPORT FOR REPAlRJREPLACEMENT ACTIVITY As Required by the Provislons of the ASME Code.Section XI

1. 0M1er.

Southam Nuclear Operatlng Co.

Date:

1013Ofl010 Nst716 40 Inverness Center Parkway; BirmIngham, Al35242 Sheet.

of 2

Addmss

2. Plant Joseph M. Farley Nuclear Plant (FNP)

Unit FNPUnlt 1


~M~a-m8--------~-------

7388 North Slate Hwy 95; Columbia, Al36319 Work Order No.: B13-1103111901 AddlSSfJ RepslrlReplacemMt Organization PO No, Job No, etc.,

3. Work Pet10rmed By:

FNP Maintenance Department Type Code Symbol Stamp:

N/A Nam8 7388 North Slate Hwy 95; Colwnbia, Al 36319 Aulhorlza1lon No.:

NlA Address El<plratlon Data:

NlA

4. IdEll11fflcatlon of System; TPNS: Q1Bl3SNUBBRCR212 REACTOR COOLANT SYSTEM. ASME CLASS 1
5. (al Applicable Construction Code:

See Remarks

,NlA Edition.

NlA

Addenda, NlA Code Case Yiiii'"

(b) Applicable Edition of Section XI Used for Repair/Replacement ActIvIty:

2001 Addenda:

2003

--~y,~~~--

(c) Applicable Sectlon XI Code Case(s):

NlA

6. IdenUflcat!on of Componenl8:

NaUonal Corrected.

ASMECode Nemeot OIher Year Name of Component ManufacbJrar Serial No.

Board Removed, Of Slamped Manu\\acbJrer Identification Built No.

Installed (Yes 01' No)

Hydraullo Snubber ITT GRINNEll RCR*R212 NlA FNp*222 1975 Removed NO HydrauDc Snubber ANVIL

~5 NlA QP090698 2009 Installed NO

7. Description of Work:

Snubber RC-R212 was replaced as a scheduled upgrade Ref: Transacllon" 197310

8. Tests Conducted:

Hydrostadc Nominal Operallng PressUf9

~I Exempt OIher §it Pressure:

Teal Temp.:

OF


psi NOTE: Supplemental sheel8ln form of lists, sketches, or drawings may be used. provided (1) s/zels 8-1/2 In. II 11 In., (2) informaUon In Items 1 throuttJ 6 OIllhis report Is included on each sheet, and (3) each sheet Is nwnberad and number of sheets Is recorded at the top of this form.

FORM NIS*2 (Back)

9. Remarks Supports Designed 10 AI6o.1969 and welded 10 AWS 01.1*86.

Reference equivalency detennlnation C092313201 Ret Transac!lon t 197310 VT-3 Cooducted CERTIFICATE OF COMPLIANCE I certffy that the statements made In the report are correct and that this conforms to the requirements 01 the ASME Code,Section XI.

~s 06s/gflfHl, Titfe

--+--+..0.&..-----1 Type Code Symbol Stamp:

NJA Certificate of AuthorlZallon No.:

NJA Elql!ratlon Date:

N/A Signed:

~~

Asia O. Jerkins. Supt Support Date:

1/-U11 CERTIFICATE OF INSERVICE INSPECTION of have Inspected the componeots described In this OWrlEll"s Report during the pe to

.and state that to

/.b-P the best of my knowledge and beUef.1I1--e--,:...;r..c::;..::;"'p,ge~rform--ed-e-JI8ITI-I-natlons-- and taken~ectIVe measuros described In this OWnets Report In accordance with the requirements of the ASME Code, SecIion XI.

By slgnill{J this certificate neither the Inspector nor his employer makes any warranty, expressed Of ImpHed. concerning the examinations and correcIive measures described In this OWners Report. Furthermore, neI1her the Inspector nor his employer shall be liable In any manner for any pamonallnjury or p~ damage Of a loss of any kind arising from or connected with this Inspection.

Data: ______~~~~-------------

FORM NIS-2 OWNER'S REPORT FOR REPAIR/REPLACEMENT ACTIVITY As Required W!he Provisions of the ASME Code. Secdoo XI

1. Owner:

Southem Nudear Operating Co.

Date:

December 1, 2010 NBIT/f1..

. 40 Invemess Center Parkway; Birmingham, AL 35242 Sheet:

of 2

2, Plant Joseph M. Farley Nuclear Plant (FNP)

Un":

FNPUoit 1


~------~N~BITIf1~*~---------------

7388 North State Hwy 95; Columbia. AL 36319 Work Older No.~ 1103184001 Addrsss RepaJrlFl~t OrgsnizatJcn PO No, Job No. etc;. *

3. Work Perfonned By:;

FNP Maintenance Department Type Code Symbol Stamp:,

NlA Name 738e Nonh State Hwy 95; Columbia. AL 36319 Authorizalion No.:

N1A Address E)(!llrallon Date:'

NJA 4, Identiflcallon of System:

Q1Pl6V005E* 1C CCW HX SW OUTLET TUBE SIDE DRN (COde class 3) 5.. (a) Applicable Construction Code:

Section III

  • 1971 Edition, W' 1972 Addenda.*

N/A Code Case Year (b) Applicable Edition of Section XI Used fO( RepwrlReplacement ActMty;:

2001 2003 Yesr (e) ApplIcable Section XI Code Case(s)r NlA

6. ldentlflcation of GOfnponents:

Natlonal COrrected, ASMECode Name of OIher Year Name of Component Manufacturer Sarial No.

Board Removed,or Stamped Manufacturer ldenliflcallon Built No.

Installed (Yes or No) 2" Valve (Bonnet)

BNllnd.

93A NfA QP070nS 2008 REMOVED YES DIsc BNllnd.

126A NfA QP070n5 2008 REMOVED YES Body BNllnd.

126A-1 NfA QP070nS 2008 REMOVED YES 2" Valve BNLlnd.

A070809-1-61 NlA QP070nS 2008 INSTAllED YES

7. Description of Work:

REPLACED VALVE 8, Tests Conducted:

Hydrostattc [J Pneumatic, []

Nominal Operallng Pressure fa Exempt [J Other[J Pressure:

_~_.......psf Test Temp.!.

Of NOTE: Supplemental sheets In fonn of liSts. sketches, ordraWings maybe used. provided (1) size is 8-112 fn.x 11 in.. (2) information in items 1 through 6 on this report is Included on each sheet. and (3) each $heet Is numbered end number 01 shOOts Is recorded at the top of this form.

FORM NI8-2 (Back)

9. Remarks Replacement Valve Is ASME Sec. III, Wrnter 1971 w/w'1971 edition. and para NB811'.1C of w' 72 class 3 Transaction II: 196419 VT*2 Completed Sat.

CERTIFICATE OF COMPLIANCE I certify that the statements made In the report are correct and that this conforms to the requfrements of tlla ASME Coda,Section XI.

Type Coda Symbol Stamp:

NlA Carlifioate of Authorfzalfon NO~

N/A Expiration Date:

NlA Signed:

~(I ~

Asia O. Jerkins. Maintenance Spl. Support Dale: 1/"/,,

O~f Ownet"s Designee. TiUe

~(~,f-.!.L------I CERTIFrCATE OF INSERvrCE INSPECTION I. the undersigned. hofdlng a valid commission Issued by the National Board of Boller and Pressure Vesselinspectora and the State Of Province of ~//f=": and employed by.,;,..r.J:l,;;iIIioI,--,"'Cl';:;:'-;";'___~"""'_________-I of have Inspected the components described In this r,

I:)

10

/U/II

'and slate that to armed examinations and tak"~e measures descrbed In this Owner's Report in accordance with lhe requirements of the ASME Code,Section XI.

By signing this certlflcete neither the lnapectornor his employer makes any warranty, elq)l'essed or Impled, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspeclor nor his employet' shall be llableln any manner for any personal Injury or property damage or a loss of any kfnd arising from or connected with this inspection; Date::, --.r,.r:o:;;;;r,.~,",,"---------'

FORM NIS-2 OWNER'S REPORT FOR REPAIRIREPLACEMENT ACTIVITY As Required by \\119 Pruvlslons of \\I1e ASME Code, section Xl

1. OWner.

SouIhem Nuclear Operating Co.

Date:

1(112712010 Name 40 Inverness Center Parkway; Birmingham, AL 35242 Sheet of 2

AckJrsss

2. Plant:

Joseph M. Farley Nuclear Plant (FNP)

Unit FNPUnlt 1 Name 7388 Norltl State Hwy 95; Columbia, AL 36319 Work Order No.: N21* 1103223901 Address RepsJrlRepkwsmfJIJt Drgsntzstion PO No, Job No, etc..

3. Work P9Iformed By:

FNP Maintenance Department Type Code Symbol Slamp; NlA 7388 North Stats Hwy 95; Columbia, AL 36319 Aultlorizatlon No.:

NlA Addmss ExpIration Oate:

NlA

4. ldenllllcation cI System:

TPNS: Q1N21SNUBBFWR46B FEED WATER SYSTEM, ASME ClASS 2

5. (a) ApplJcable Construction Code:

See Remarks

,NJA Edition, N/A Addenda.

NJA Code Case

'"Ve6r' (b) Applicable Edition of Secllon Xl Used for RepairlReplacemenl Activity:

2001 Addenda:

2003 Year (0) AppUcable SectJon Xl Code Case(s):

NlA

6. Iden1Iflcatlon of Components:

National Corrected, ASMECode Name of Other Year Name of Component Manufacturer Serial No.

Board Removed,or Stan'l>ed Manufacturer ldenllflcatkln Built No.

Installed (Yes or No)

Hydraulic Snubber ITT GRINNEll 24189 NlA FNP*2*29 19n Removed NO Hydraulic Snubber ANVIL 38271 NlA QP101007 2010 Installed NO

7. Oe:scripllon of Work:

Snubber FW*A46B was replaced 8$ a schedUled upgrade Rei: Transaction # 197535

8. Tasts ConWctsd:

Hydrostallc fII Pneumatic til NominaL OperatIng Pressure §II Exampt tal Pressure:

psi Tesl Temp.:

OF NOTE: Supplemental shee1s In form of IislS. sketcheS. or draWIngs may be used. proIIided (1) size Is 8-112 In. x 11 l/t., (2) Informa.tioO in Iterns 1 through 6 on this report IS Included on each sheet, and (3) each sheet Is numbered and number of sheets Is recorded at the lop of this form.

FORM NI8-2 (Sack)

9. Remarks Supports Designed to A1SG-1969 and welded to AWS 01.1-00.

Reference equivalency determination C102466701 Ref: Transaction' 197535 VT-3 Conducted CERTIFICATE OF COMPlIANCE I certify IIlat the statements made In the report are correct and that this COfIfo!ll1S to the requirements of the ASME Code,Section XI.

Type Code Symbol Stamp:

NlA Certlflcate of Authorization No.:

N/A Expiration Date:

N/A Signed:

. A

~." Asla 0. JerlIlns, Supt Support Date:

, / If /"

DwnSfor~ Designee, Title....!..J,~-----I CEArIACATE OF INSERVICE INSPECTION I. the undersigned. holding a valid commission Issued by the NaUonaI Board of Boller and Pressure Vessel Inspectors and the State Of Province of ~t and employed by.....tJ==::;.._...:::::l-~______________-I of

~ fL-have inspected the components described In this OWners Report durfngthei)l;'rtJi ::= ~//O to 1.1!:z.II/

' and stale that to the best of my knowledge and belief. the owner hal~ed examinations and taken k~ measures described In this Owner'e Report In accordance wittllhe requirements of the ASME Code,Section XI.

By s/lJIlng this cenlftcale neilher the Inspector nor his employer makes any warranty, expressed 01' implied. concerning the examlnattons and correctlve measW'ss d9SClil:led In this OWner's Report. Furthemlore. neither the Inspector nor his employer shaD be liable In any manner for any persona/Injury 01' propelty damage or a loss of any kind arising from or connected with this Inspection.

Oa~: ______~~~__-----------

SHARED

.. *;;/24110 13:29:45 FNP-O-GMP-0.2 F'

1 FORM NIS-2 OWNER'S REPORT FOW'K~PAIRJREPLACEMENT ACTIVITY As Required By The Provislona Of The ASME Code Seelion XI

1.

Owner Southem MIc/ur Oeeral!ng Comp!l1Y Date NOWImber 24, 2010 Name 40 In~ CtmIW partway Blrmlnghsm, AlsbMn.35242 (l1li afl!l!t forAlalNtma Power Company) 1 Add.....

.2.

Plant

'Brlg Nue""" PfIInt Unit 1

Name Highway 95 South Co/umbra, Ahlbllma 38319 P16 - WOI 109133441J3 Addres.

Repair/Replacement Organization P.O. No., Job No., etc.

3.

Wor1c Pelionned by Southern NueltlSf Opertltfng Type Cod. Symbol Stamp (IVA Company / ES

  • McdIficationa Name Authorlmlon No.

NlA E~~D" ________________________~~~_______________

FBrley NuC'ltlar P/ent Addnt8.

4.

Identification of System P16/ SttrvlCtl WlJter

5.

(e) Applicable Construction Code ASME Section Ilf

Edition, 1980 Addenda.

1982 (b) Applicable EditIon of Section XI Used for RepairlReplacement Activity 2001 Addenda,~

(c) AppIloabie Section XI Code Caae(a)

NlA

6.

identification Of Components National ASMECode Name of Name of

. Manufacturer Other Vear SerIal No.

No.

Built (Yes or No)

JOINT KT/1i06-1-2 NlA P.O. QP080649 21H1B REMOVED YES AI IOPS::::':" INC JOINT IOP~:'NC KBIlB6IJ.1-1 NlA P.O. QPtI90329 2009 INSTALLED YES

7.

DMCription of Woric The ultJtJng sxptll7Blon }oInI.... not dHlJllHld with l1li ofIHt ReplIICIId with lin tlxplllllillon joint with II dtNIlgn!d offsetper AIDC 1091394401 tJnd W(W 1091334<<13 for Unit 1, SW Pump Q1P16POO1E.

ENpMaion Joint TPNS Q1P16FD502E.

a.

Teat Conducted:

HydroatAtlic 0 PneumattcD Nominal Operating PI'1II88UnIOO ExemplD Other 0 P....aure psi Tnt Temp. _____ "F Page 1 of 2 Version 22

.~

SHARED 11/2411008:18:19 FNP-Q-GMP-O.2 Figure 1 FORM NI6-2 (Back)

9.

Remarks


~~~I~~~M~~~~~~~~a~D~~R~~~~w~b-.~a~~h-~~-------------------

CERTIFICATE OF COMPLIANCE We certify that the.statements made In the report are correct and that this Replacement conforms to the rules of the ASME Code,Section XI.

repair or replacement Type Code Symbol Stamp ______________......:.N!...:.;:4-=---____________---i Certificate of Authorization No.

NlA Expiration Date _______....;N!....;;.;...;:4_____--I Signed C2"'J~L "'. /£.L~k..A~.,.,.

Date

'UOwner or Owner's Design ** Title CERTIFICATE OF INSERVICE INSPECTION I. the undersigned, holding a vall~sion issued by the National Board of Boile~d Pressure Vessel InsPect9~ and the state or Province of ~

and employed by H$S

~

of 4t1'flC'l ftftD. "b('

have Inspected~e components described In thlB Owner'B Report during the period

't/'~"

to 1~lk l/)

and state that to the best of my knowledge and I

belief, the Owner has performed examinations lid ken corrective measures described In this OWner's Report In accordance with the requirements of the ASME Code, Section XJ.

By signing this certificate neither the Inspactor nor his employer makes any warranty. expressed or implied.

conceming the examinations and corrective measures described in this Owner's Report. Furthermore. neither the Inspector nor hie employer shall be liable in any manner for any personal injury or property damage or a loes of any kind arising from or connected with this inspection.

________~_~~~~A~~~~______----Commi8Slon8~4~~~~7~~--~~--~~_._----~__

In8~

National Board, State. Province and Endorsements Page 2 of 2 Version 22

FORM NI9-2 OWNER'S REPORT FOR REPAlRlREPLACEMENT ACTIVITY As ReqUIred by the ProviSions of the ASME Code,Section XI

\\.......

1. Owner:

Southam Nuclear Operallng Co.

Date:

July 9, 2010 NsmB 40 Inverness Center partcway; Birmingham, AL 35242 Sheet:

of 2

AcJdmss

2. Plant:

Joseph M. Farley Nuclear Plant (FNP)

Unit:

FNP Unll1 NsmB 7388 North Stata Hwy 95; Columbia, AL 36319 Work Order No.: E11-1091560501 Address Repair/Replacement Orpanlzatlon PO No, Job No, etc.

3. Work Performed By:

FNP Maintenance Department Type Code Symbol Stamp:

NlA 7388 North State Hwy 95; Columbia. AL 36319 AuthoJizatlon No.:

NlA Address Expiration Date:

NlA

4. Identification of System:

TPNS: Q1E11SNUe8RHR10R46 RESIDUAL HEAT REMOVAL SVSTEM. ASME CLASS 2

5. (a) Applicable Construction Code:

See Remarl<s

  • NlA Ec:Itlon.

N/A Addenda.

NJA Code Case Yiiiif (b) Applicable Edition of SectIon Xl Used for RepafrlReplaooment ActI\\IIty:

.2001 2003 Ysaf (c) Applicable Soolloo XI Code Case(s):

NlA

6. k:lenllflcallon of Components:

Name of Component Name of Manufacturer Manufacturer Seria/ No.

NaHonai Board No.

Other Identiflca1lon Vear Bunt Corrected, Removed. or Installed ASMECode Stamped (Yes or No)

Hydraulic Snubber ITT GRINNELL 24183 NlA FNP-2-29 1981 Removed NO HydrauDc Snubber ANVil 37760 NlA QP090698 2009 Installed NO

7. Descrlptfon of WOIk:

Snubber RHR,10A46 was replaced as a scheduled upgrade Ref: Transacllon /I 187668

8. Tests Conducted:

Hydrostatic. Pneumatic 1.1 NomInal Operating Pressure SI' Exempt ~

Other III Pressure: ____psi Test Temp.: ____ oF NOTElSupplementaJ sheets In form of liSts. sketches. or dreWings may be used, provided (1) siZe Is 8-112 In. x 1 t In., (2) Informatloo in items 1 through 6 on this report is Included on each sheet, and (3) each sheet Is numbered and number of sheets is recorded at the top of this form.

FORM NI$-2 (Back)

9. Remarks Supports Designed to AlSC-1969 and welded to AWS 01.1-00.

Reference equivalency determlnatlon C092533401 Ref: Transaction 1# 187668 VT*3 Conducted CERTIFICATE OF COMPUANCE I certify thai the statements made In the report are correct and that this conforms to the requirements of the ASME Code. Sactlon Xl.

Type Coda Symbol Stamp:

NlA Certlllcate of AuthOrization No.:

NlA ExpIration Date:

NlA Signed:

_ ~... AsIa O. Jerldns. Supt. Support Oats: --,-

/"'1-,/--.;;1'..::..;.----1 Owne~sr'S Des/iJI766. ntte CERTIFICATE OF INSERVICE INSPECTION I. tha undersigned, holding a vaJld commIssIon issued by the Natlonal Board of Boller and Pressure Vesseilnspectol'S and the Slate or Province of and employed by cr

~~~~--~----~------~~--~

of a.:

have Inspected the components dElSClibed In this Owner's Report during the Period

~

to. ~~I

  • and state that to the bast of my knowledge and belief. the owner nned 9wninatlOns and tak~~e measures descrlbed In this Owner's Report in accordance with the requirements of the ASME Code, Section Xl.

By signing this certificate neither the Inspector nor his employer makes any warranty. elqll'sssed or implied. concerning the examinations and corrective measures described In this OWners Report. Furthermore. neither the Inspector nor his employer shall be liable In any manner for any personal Injury or property damage or a loss of any kind arising from or connected wtth this Inspectioo*.

~or'SSlgnature Date:

'l"z¢'

FORM NIS.2 OWNER'S REPORT FOR REPAIRIREPLACEMENT ACTIVITY As Required by the ProvIsIoos 0/ the ASME Coda, Section xr Southern NU()laar Operating CO; Date::

November 11, 2010 I

Nsrne 40 Invemess Center ParkWay;8Irmingham. AL35242 of 2

Address 2; Planl:

.Joseph M. Farley Nuclear Plant (FNP)..

Unit:

FNP Unit 1


~----------N~/J~me------~--~-----

7388 North State Hwy 95; Columbia, At 36319 Wor!( Order NO'.:

10916744{)2 AddfS58 RepalriReP1scertlf!1nt Organizatfon PO f\\/(1;' Job No. etc..

3. Work Performed By:

FNP Maintenance Department Type Code Symbol Stamp:

NlA Name 7388 North Slate Hwy 95; Columbia, AL36319 Aulhorlzalibn No" NlA Expiration Dale:;,

N/A

4. ldentlficalion of Systamf

. TPNS: "01 E21V173LTDNCATION BED DEMIN INLET ISO VALVE (Code class 3)

5. (a) AW!lcable Construction Code,

.Section III

  • 1971 Edition. 1971 Summer Addenda, NlA Coda Case

~~---- ~

(b) AWJitabie Edition of SectIon XI Used for Repalr/Replacement Activity:.

2001 2003 Year

.(<:) AppliCable Section XI Code Case(s)t~

NlA 6., ldentffication 01 Components, NatIonal Cortected, ASME Code Name 01 Other Year Name of Component Manufacturer Serial No.

Board Removed,or Stamped Manufacturer ldentiflcatlon Buill No.

Installed (Yes or No) 2' Dlaphram Valve GRINNELL 73*2761*4-4a Nla FNp*SB4 1974 REMOVED YES 2" PIPE ITT GRINNEll JG*19(D)*510 Nla FNP*365 1975 REMOVED NO 2'Elow ITT GRINNELL JG*19(D)-511 Nla FNP*386 1976 REMOVED NO 2" Dlaphram Valve BNL Industries A100608*1*2 Nla QP100602 2009 INSTALLED YES 2* PIPE SANDVIK 519775 Nla QP090652 2007 INSTALLED NO 2'Elow Bonney Forge 44013 N/a QP090485 2007 INSTALLED NO REPLACEMENT OF:t* DIAPHRAM VALVE

8. Tesls Conducted:.

Hydrostatic []

Pneumatic [J Nominal Operating Pressure &!I ExamplCl Other[]

Pressure;*

Test Temp.; ____ "F


psi NOTE: S\\.WIemenlal sheets In form of,_ sketches. ordrewlngs may be used.*Pfovided (1) size is 8-112 In. x 11 in.* (2) information in items 1 throudl 600 this report ts Included on each sheet, and (3) each sheet Is numbered and number 0/ sheets Is recorded al !he lop of this fonTl.

FORM NIS.2 (Back) 9, Remalks Reconciliation 01 component dilterence Is per MDC 1091674401

wGtiIIt~lDiI,i."il"IlIlOliuL
ii<ld*

Replacement valveconst.fUelion Is.A8ME Sec. III 1971 Edition. Winter 1971 Addenda code class 3 Replacment Pipe and Elbow is ASME Sec-III Subsection NC 1983 Edition. Winter 1983 Addenda

Reference:

FNP Piping SpecificatIon 85110902 allows a construction Code 01 ASME Section 111, 1971 Edition thru 2000 Eartlon Addenda VT*2 Completed Sat.

Transaction #'s: 194008. 195298 CERTIFICATE OF COMPLIANCE I certify Ihatthe statements made In the report are correct and that this conforms to the requirements of the ASME Code,Section XI.

Type Code Symbol Stamp:

NlA Certificate of Authorization No.:

NlA Expiration Date:

NlA SIgned:

~/

Asia O. Jerkins, Maintenance Spl, Support Date: --,-,A-,-,/J-,-,,-----I

~ror Owners Designee. Titls CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission Issued by the National Board of Boller and Preasuro VessaIlnspectolS and the State or Province of

~/.t:

andem~by.....=i;;:;.._.;;e~________________t of Owners Report during the nod

.to have Inspected the components described In this

~~.h

'and s.tale that 10 as "ormed examinations and taken~e measures descnbed in this OWners Report In accordance with the requirements of the ASME Code,Section XI.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied. conceming the e)(Qn1inalions and corrective measures described In this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable In any manner for any personaJ InjUly or properly damage or a loss of any kind arising from 01 coonooted with ItlIs InspecIIon.

~SignatUf8 Date: f,¥

11/11/1013:22:11 FNP-O~GMP..().2 FORMNIS..2OWNER'S REPORT F6WW~~AIRJREPLACEMENTAcnvrrv As Required By TM Provlalona Of The ASYE Code Section XI

1.

OWllIN' SOUTHERN NUCI.EAR OPERATING 00.

Date 06116110 Name 2

40 INVERNESS CENTER PARKWA Y BIRMINGHAM AL. 35242 Adrhu

2.

Plant JOSEPH M. FARLEY NUCLEAR PLANT UnIt FNPUNlT1 Nama 7388 NORTH STATE HWY. 96 E2t 1091921503 COLUMBIA AL 36319 RapairlRepfaoement Organization P.O. No., Job No., etc.

3.

Work Pedormed by WILUAMS POWER GROUP TVJ)e Colill Symbd SbIII1p NlA NIVM Aulltodzatlon No.

NlA FARLEY NUCLEAR PLANT

~Q~D" ________________~~~~___________

Addr...

4.

IdenUficatlon of System TPNS: Q1E21V0026 (RWST SUCTION CHARGING PUMPS SUCTION CHECK VALVE) ASME CLASS 2 8" HCB-42 PIPINt3

5.

(8) ApplIcable Construction Code ASM! SEcnON In Edition, __;,;;;1968=-__ Addenda, WINTER 70 Code Case (b) Appllaabfe edition of SectIon XI Used for RepalrlReplaoement Activity ____

(0) Applicable SectIon XI Code C8t1e(s) _____

8.

Identification Of Components Nat/onat Corrected.

ASMECode Nam.of Nan14Jof Manufacturer Board Other Ve.

Removed, 01 Stamped ComDOnent Manufacturer Serial No.

No.

ldentlflcatlon Built Installed JV8aorNo)

VALVE COPES-VULCAN 1973 REMOVED YES BONNET BONNET VALVE SPX 1tJ50.170331-1*

NlA Hr' 5152ANE4 2Of()

INSTALLED NO BONNET CORPORATION 1(1(J..2l BONNET 7110-95182*5-3

7.

Ducrlptlon of Work REPLACED BONNET WITH VENT VALVE INSTALLED

8. rest Conduc18d:

HydrostatIc 0 PnaumatioO Nominal OperatIng Preesural!l ExemptD Other 0 Pressure psi Test Temp. ____ "F Page 1 012

06/2311013:21:32 FNP*O-GMP-O.2 Figure 1 FORM NIS-2 (Back)

9. Remarks REPLACEMENT BONNET HAD MANUFACTURER TO DRILL HOLE IN BONNET TO ALLOW INSTALUNG Applicable Manufaoturet'. Data AepoI1a to be attached

~.. VENT VALVE CERTIFICATE OF COMPUANCE We certify that the statementa made In the report are correct and that this conforms to the rules of the ASME Code,Section XI.

repair or replacement T~CodeS~bol~mp __________________________~m~~~.....______________________~

Certificate of Authorization No.

NlA Expiration Date ______m~~~_____i Slgn~ 04-:::sr:vlI,J, S...t\\h&:tc Date Ii/~

~wner or Owner's Desigllee. Title INSPECTION I, the undersigned, holding a valid commission issued by the National Board~oiler and Pressure lLnslpel!:JOlI'$ and the state or Province of

~t4It:

and employed by

'~ ~,...

of

'W"&II1-n.~

C;;("

insp ct the components described In this Owner's Report during

'U""""JU-l~"A'~____....,..._to and state that to the best of my knowledge has performed examlnatio s nd taken corrective measures described In this Owner's Report laeetu'dall1tlA with the requirements of the ASME Code,Section XI.

By signing this certHlcate neither the Inspector nor his employer makes any warranty, expressed or imr:J11iec:lI,1 Icoin~!Jmilng the examinations and corrective measures described in thIs Owner's Report. Furthermore, neither IInl!;pec~tor nor his employer shalt be liable in any manner for any personal Injury or property damage or a loas of arising from or connected with this inspection.

~.J Commissions 12M-~ 6f1l:,-z...1

~nspectorts Signature Nallonsl Board, ~e, Province and Endorsements Date 11-11-/0 Page 20f 2

FORM NI8-2 OWNER'S REPORT FOR REPAIR/REPLACEMENT ACTIVITY As Requ'red by the Provisions of the ASME Code. SeclJCII Xl Southern Nuclear Operating Co.

Date:

October 23. 2010 Name 40 In'o'eJlle9S Center Parkway. Blrmln\\tlam. AL 36242 Sheet of 2

Acfdn1ss

2. Plant:

Joseph M. Farley Nuclear Plant (FNP)

Unit:

FNP Unit1


~Nam~-Q----------------

7388 North State Hwy 95; Cdumbla. AL 36319 Work Order No.:

E21* 1092221201 Adclress RepakfReplacement Orgsnlzatbn PO No, Job No, etc.

3. Work Perlormed By:

FNP Mai'ltenance Department T)1J6 Code S~boI Stamp:

NJA Name 7388 North State Hwy 95; CoILITlbia, AL 36319 AuthorlzatIoo No.:

NlA Adclr6SS Elq)Iratlon Date:

NlA

4. IdaJUlIcatIal of System:

TPNS# Q1B2tSNUBBFT425A STEAM GENERATOR SVSTEM, ASME Class 2

5. (3) Applicable Coostructlon Code:

See Remarks

,NlA Edition.

N/A

Addenda, N/A Code Case

'""Ye8r"'

(b) AppDcabIe EdtIoo of SectJon Xl Used for RepairlAepiacement Activity:

2001 Addenda:

2000 Year (0) AppIJeablEl Section Xl Code Case(s):

N/A

6. Identification 01 Components:

Corrected.

ASMECode Name of Nallonai Other VfW Name 01 COmptnen!

Manufacturer SeJtal No.

Removed, or Stamped Manufacturer Board No.

Identification Buill Installed

{Yes or No)

Mechanlcat Snlilber Pacific* Scientific 37958 NlA QP*1470 1987 Removed NO Hydraullic SnulXler Usega 309003721021.

NlA QP100469

2009, Installed NO
7. Description ofWOfk:

SnlAlber FT 425A was replaced as a scheduled upgrade Ref: Transaction It 191701

8. Tes1S Conducted:

Hydrostatic II Pneurnalic III' Nominal Operaling Pressure II Other

  • Pressure: ____psi TestTemp.: ----

OF NOTE: Supplemental sheela In form dlists. sketches, or draM1gs may be used. provided (1) size Is &-112111. x 11 In.,

(2) information in iIems 1 through 6 on this report is Included on each sheet. and (3) each sheet Is numbered and number of sheets Is recorded at the top d thls form.

FORM NI5-2 (Back)

9. Remarks Supports Designed to AIsc.1969and wek:led to AWS 01.1-86.

Reference equivalency determination (EO) 96-().(}225 Rev 1 Ref: Transaction jj 191101 VT-3 Conducted CERTIACATE OF COMPLIANCE I certify that the statements made In the report are correct and that this conforms to the requirements of the ASME Code, SectIon XI.

~r's DSS{gn68. TIlI9

_-I-',~...l.-____-I TWJ9 Code Symbol Slamp:

NlA Certificate d AuthoriZatIon No.:

N/A EJCpiraIIon Date:

NlA


1 SIgned:

~~ Asia O. Jerldns. Supt Support Date:

I/"J;"

CERTIFICATE OF INSERVICE INSPECTION I. the unders/fJled. ho<<li1g a vaUd cunmlsaloo Issued by lfIe National Board d Boler and Pressure Vessellnspectm and lfIe State or Province af ~ and employed bv-llliiooalolC-...lifc...___________--I of

~

cr-have Inspected the COOlponents described In IhI8 OYmer's R~~

dlll1JIJ to J/~I

.andstatelhat to the best at my knoWledge and belief, tile OWner ~PJrOfmed examinations and takI!Ilt~.:neasures descrbed in this Qwne(s Report In accordance wiIh (he requirema'lts d lfIe ASME Qxfe, SectIon XI.

By signing lfIis cer1iflcale neilher !he Inspector nor his employer makes any warranty. 8lq)fe5S8d or Implied. coocemlng the examinations and carrectiwl meastIIlIII described In this OWners Report. Furthermore, neither the Inspector nor his employer shall be liable In art'f manner for any personaIlnjory or prq:lGI1y c:Iamage<< a loss d any kind arising fran << ccnnected with thls Inspection.

Date: __~~~~-__-----------

FORM NIS*2 OWNER'S REPORT FOR REPAIR/REPLACEMENT ACTIVITY As Required by the Provisions ollhe ASME Coda,Section XI

1. Owner:

Southern Nuclear Operating ~o..

Date:

October 20.2010 Name 40 Inwmess Cenler Parkway: Birmingham. AL 35242' Sheet 2

2.. Plant:

Joseph M. Farley Nuclear Plant (FNP)

FNP Unltl Name nas Notlh Slate Hwy 95; Columbia. AL 36319 Work Order NO.1 G24-1092222101 Address" RepajrlFi'eplscemsnt Drri8nlzatJon PO NO; Job No, etc.:**

3. Work Performed By; FNP Maintenance Department Type Code Symbol Stamp:

NlA NBJfIII*

7388 North Stale Hv.y 95; Columbia. AL 36319 AuthorizatIOn No.;

NJA Address Expiration Date:

NlA

4. IdenIlfIcalfon of System; TPNS, a1G24SNUeBSS4580 'STEAM GENERATOR BLOWDOWN SYSTEM, ASME Class 2
5. (e) AA'lk:abIe Construction Code:

See Remarks NlA Edition.

N/A Addenda.

NlA Code Case y;a;:-

(b) AWUcable Edition of Section XI Used lor Rep8Jr/Repla~ent Activltr.

2001 2003 Year (cl Applicable Section XI Code Case(s):

NlA

6. IdentifIcation of Components:

National Col1'llCted, ASMECode Nama of Other Year Nama of Component Manufacturer Serial No.

Board Removed. or Stamped Manufacturer ldentiftcallon Built No.

Installed (yes or No)

Mechanical Snubber Pacific-Scianliflc 324 N/A FNP*222 1976 Removed NO Hex Bolls (4)

Pacific* Scientific UnK NlA FNp*222 1976 Removed NO Hydraullic Snubber Usega 30700491/111 N/A QP080176 2007 Installed NO Hex Bolts (4)

Nova MachIne 8092338 NlA QP000347 2000 Installed NO 7, Description of Work:

.Snubber SS-458O was replaced as a scheduled upgrade Ret Transacllonl! 191723 B. Tests Conducted:

Hydrostatic []

Pneumatic [J Nominal Operating Prassure [J Exempt

(;!I OthQl[J PrElSSl.lf8t _____ psi Test Temp;;

"F NOTE: SUpplementaf sheets in form of lisls, skaIdles, or drawings maybe used. provided (1) size is 8-112 In. x 11 in;, (2) informatlon In items 1 through 6 on this report Is included on each sheet, and (3) each sheet is numbered and number 01 sheets.js recorded at the top of this form.

FORM NIS-2 (Back) 9; Aemad<a Supports Designed to AtSC*1969 and welded to AWS D1.1.aa Reference equivalency determination (ED) 96*(}..()225 Rev 1 Rel:*TransacIiOO /I's 191723.196397 VT*3 Conducted CERTIFICATE OF COMPliANCE I certify thallhe statements made In the report al'$ correct and that this conforms to the requtrements of the ASME Code,Section XI.

Type Gode Symbol S!amp:

NlA

""_"'_Y NlA NlA Signed:

~'2...

Asia O. Jendns, Sup\\. Support Date: --';;'-{_~t-"-h',,--,r___-t Owner or Ownets DBSignee, TitI6 CERTIFICATE OF INSEAVICE INSPECTION I, the undersigned, holding a valid commission issued by lhe National BoaId of BoIIBf and Pressure Vessallnspectors and the State or Province of

~1.It:: and employed by--.t.:'=;""'"_=_~__________~~-:-:--I of haw Inspected the components described 10 this OWner's Report during the peiiod b

10 Ikml

.and state that 10 the best of my knowledge and belief. the Owner rIormed examinations and taketi'co;(ectiYa measures described In this Owner's Report In accoo:Janoo wilh the requirements of the ASME Code.Section XI.

By signing this certllicate nelIher the Inspector nor his employer mllk68 any walT8llly. expressed or implied. concerning the examinations and corrective measures described In this Owners Report. Furthermore. neither the Inspeclor nor his employer shall be liable In any manl18l' for any personal Injury or property damage or a loss of any kind artsIng from or connected with this Inspection.

Date:

-~~~----------------------

FORM NI8-2 OWNER'S REPORT FOR REPAlRlREPLACEMENT ACTIVITY As Requir:!d by the Provisions d the ASME Code, Sectloo XI

1. Owner:

Southem Nuclear Operating Co.

Date:

0ctI2312010

. Name 40 Inverness Center Parkway; Birmingham. AL 35242 Sheet:

of 2

Address

2. Plant Jooep, M. Farley Nuclear Ptanl (FNP)

Unit FNPUnltl


~------N.~~----------~------

7388 Norlh State Hwy 95; Columbia; AL 38319 wort< Order No.:

E21* 1092222201 Ack:Jms Repa,lRep/scement OrgE1lllzatlon PO NO, Job No, etJ:;.

3. WOI1< Performed By.:

FNP MaIntenance Department Type Code Symbol Stamp:

NJA Name 7388 North State Hwy 95; CoIIJrnbla, AL 36319 Authorization No.:

NlA Address Elq:llratlon Date:

NlA

4. ldentlf!catfon d System!

TPNSi 01E21SNUBB8S4743 'CHEMICAL VOLUME CONTROl SYSTEM, ASME Class 1 5.. (a) ApplIcable Construction Code:

See Remarks

,NJA Edllloo.

NlA

Addenda, NlA Code case

--y;;;;

(b) Appbble Edmon of SectIon XI Used for RepairlRepiacement Activity:

2001 Addenda:

2003

--~~~~~--

(e) AppticabIe Sectioo Xl Code casa(s):

NlA

6. ldootlflcallon d Components:

Corrected.

ASMECode Nameot NatIcoaI Other YIIISl Name of Con1ponent Manufacturer Serfal No.

Removed,or Stamped Manufacll.ll'a' Board No.

Identification BuIlt Installed (Yes or No)

Mechanical Snubber Pacific-Scientific 26169 NJA OP-1470 1987 Removed NO Hydraulic Snubber Lisega 30900372/015 NlA OP100469 2009 Installed NO

7. Descriltioo of Wa1c Snubber 88-4743 was replaced as a scheduled upgrade Ref: Transaction It 191700
8. Tests Cooducted:

HydroStatIc II PneumaIIc III NOOlinal 0peraIi'9 Pressure III Pressure:

Test Temp.:

OF


psi NOTE: SupplBmentai sheets In form d lists, sketches. or drawings may be used, provided (1) size Is 8-1/2 In. x 11 In.,

(2) information In ItemS 1U'I/OUttI6 on IhIB repc.rt 16 ilcluded on each sheet. and (3) each sheet is ntIIlbered and number of sheets Is recxwded at the top of this fam.

FORM NI&-2 (Back)

9. Ranarks Supports Designed 10 AISC*1969 and welded 10 AWS D1.l-8&,

Referlll1ce equivalency detenTllnatlon (ED) 96-0-0225 Rev 1 Ref: TransOOlla'l If 191700 VT*3 Conducted CERTIFICATE OF COMPlIANCE I cenlfy that the stalBmen1S made In the report are correct and that tilts conforms to tile requirements of the ASME Code,Section XI.

Type Code Symbol Stamp:

NlA CSltifIcal9 of Authorlzallon No.:

NlA ExpiratIon Dale:

NlA SIgned:

~'::L..

Asia O. Jerl<lns. Sup!. SuPPort Date: --,-* h;

/.,-1'.1;,.;;.;..;..----1 Owner or~Deslgnaa. 77tIa 7

CERTIFICATE OF INSERVICE INSPECTION I. Iha undersigned, hokfng a valid commission bsued by the NaIIonaI Board of Boller and Pressure Ves&eIlnSpectors and the StateOf' Provi'lceof 6H.Jti!IkJ4=

and employed by~:'-lii::.--::cr~_____________-I of

~! cr:

have Inspected the components described In this Ownar's Repat~

AiJJAIJ 10

~I

. and state lhatto the best of my k.rIcMtedge and betIef. 1he OvinThasj5;fooned exami1aIions and Iakoo c.rmeasures described In this Owner'1I Rapat In accordance wiltt the requi'ementII 01 the ASME Code.Section XI.

By signing lhis certificate neither the InspecIQr nor his employer makes any warranty. expressed or implied, concemi'lg the examinations and corrective measures described In this Owner's Report. Furthermore. neither the Inspector nor his employer shall be liable In any manner for any personal injwyor property damage or a loss of any kind arising from or connected wiltt this 1r'lspec1Ioo.

~: --4'~~-------------------

FORM NIS-2 OWNER'S REPORT FOR REPAlRlREPLACEMENT ACTIVITY As Required by the ProvisIOns of the ASME Code, Sectlon XI

1. Owner.

Southam Nuclear Operating Co.

Date:

1012712010 NSlIl6 40 Inverness Center Parkway; Blrmlnglam, AL 35242 Sheet:

of 2

Addr8SS

2. Plant Joseph M. Farley Nuclear Plant (FNP)

Unit:

FNP Unit 1


~------N.~a~ffl9~---------------

7388 North State Hwy 95; Columbia. AL 36319 Work Order No.:

N21 -1092225101 RepalrlReplscement OrganizatiOn PO No, JcJJ NO; eta.

3. Worl< Performed By:

FNP MaIntenance Oeparlment Type Code Symbol Stamp:

NlA Name 7388 North State Hwy 95; Cobnbla, AL 36319 Authorizalloo No.:

NlA Address Expiration Date:

NlA.

4~ Identification of System:

TPNS: 01 N21SNUBBFWR46A FEED WATER SYSTEM, ASME CLASS 2 55 (a) Applicable Construction Code:

See Remarks

  • N/A Edition.

NlA

Addenda, NlA Coda Case y;-

(b) ApplIcable Edition of Section }(J Used for RepalrlAeplacement AcIMty:

2001 AcIdMda:

2003

---T,~~~~(---

(e) AppUcable Sectlon XI Code Gase(s):

NlA

6. lden!lficatlon of ComfXll'len1sr National Corrected, ASMECode Name of Other Year Name of Component Manufacturer SerIal No.

Board Removed, or Stamped Manufacturer IdenUlfcadon BUilt No; Installed (Ve9or No)

Hydraulic Snubber ITT GRINNELL 2-C&.R310 NlA FNP-2-29 1977 Removed NO HydraulIc Snubber ANVil 37754 NlA OP090696 2009 Installed NO

7. Description of Work:

Snubber FW*A46A was replaced as a sche<lJled upgrade Ret'Transaction 11191693

8. Tests Conducted:

Hydrostatic SI Pneumatic IfJI Nominal Operating Pressure mI Test Temp.: ______oF Pressure:

psi NOTE: Supplemental sheets In form of lists, sketches, or drawings may be used, provided (1) size Is 8-112 In. )( 11 In.* (2) Information In Items 1 through 6 on this report Is Included on each Sheet. and (3) each sheelis numbered and number of sheets Is recolded at !he top of this form.

FORM NIS-2 (Back)

9. Remarks Supports Designed to AISC*1969 and welded to AWS 01.1*86.

Reference equlvaJoocy determination C102466701 Ret Transact/on II 191693 VT*3 Conducted CERTIFICATE OF COMPLIANCe I CSftify that !he statements made In the report are correct and that Ihls confonns to the requirements of !he ASME Code, Section XL Type Code Symbol Stamp:

NlA Certlflcals of Authorization No.:

NlA expiration Date:

N/A SIgled:

& ~ <.

Asia 0; Jerkins, Supt. Support Date: ---'/-".,-l,;,-,,-,----1 OWner I

--;#i;:;,ers Designee, TIlle CEATIFICATE OF INSERVICE INSPECTION I. !he ooderalgned. holding a valid commission Issued by the National Board of Boller and Pressure Vessel Inspectors and !he State or Province 01 ~

andemployadby...f,J....::O:::"_';:;"'O:~______________~....

of

~

CT"'

have inspected !he components described In this OMIe!'s Report during the j5eI1od S'AViJ to

  1. z.d4

.and staIB that to the best of my knowtedge and belief, !he OwneTMlP9rlormed examinations and take6 co~ measures descrlbed In this OIo.ner's Report In accordance wllhlhe requirements of the ASME Code, Section Xl.

By signing this certificate neither the Inspector nor his employer makes any warranty. expressed or implied, COOOOITing the exami'latloos and corrective measures descrlbed in this Owner's Report. Furthermore, neither the Inspector not his employer shall be liable In any manner for any personal Injury or property damage or a loss of any kind arising from Of comected with this Inspection.

~Signatuf8

FORM NlSo2 OWNER'S REPORT FOR REPAIR/REPLACEMENT ACTIVITY As RequIred by the ProvislOOs Ii tha ASME Code, Seclioo XI

1. OWner:

Southern Nuclear Operating Co.

Data:

Octcber 23, 2010 Name 40 Inverness CeI1!er Parkway. BIrmingham, AL 35242 Sheet:

of 2

Address

2. Plant Joseph M. Farley Nuclear Plant (FNP)

Unit:

FNPUnit1


~~~---------------

7388 North State Hwy 95; Columbia, Al36319 wort< Order No.:

EtH092225801 RepairiRepiacement organization PO No, Jab No, etc.

3. Work Pertormed By:

FNP MaIntenance Department Type Code Symbol Stamp:

NJA Name 7388 NorIh State Hwy 95; CoIUrnbla. AL 36319 AlJthorizatlon No.:

N/A Elcplrallon Date:

N/A

4. Iderllffication of System:

TPNS: Q1E11SNUBBRHR6R65 RESIDUAL HEAT REMOVAL SYSTEM ASME CLASS 2

5. (a) ApplIcable Coostruction Code:

See RemarlcJ NJA Editioo.

NlA

Addenda, NJA Code Case y;;

(b) Applicable EdItIon of SectIon XI Used for RepalrlRepiacement Activity.

2001 Addenda:

2003

-~~~~~--

(c) Applicable Sec1lon Xl Code case(s);

N/A

6. IderltiflcaIIon of Components; Corrected, ASMECode Named Na1IonaI Other Year Name of Component Manufacturer Serial No.

Removed,or Stamped Manufactlnr Board No.

IderltiflOation Built Installed (Yes or No)

Hydraulic Snubber ITT GRINNELL 17003 NlA.

FNP*222 1976 R~

NO Hydraulic Snubber ANVIL 37753 NlA QP090698 2009 Ins1al1ed NO

.;~~t~
7. Oescr1;)tlon of WOI1c Sn~ RHR6-R65 was replaced as a scheduled upgrade Ref: Transactlon /I 191681
8. Tesls Conducted:

ii!iM

~ Nanlnal ~ Pressure iiiBI' Hydros1atlC.. Pneumatic I!!!a'

~

Pressl.ll9:

Test Temp.:

OF


psi NOTE: Supplemental sheets Inform of lisIS, sketches. adlawings maybe used. proIIided (1) size Is 8*112 In. x 11 in.*

(2) information In ilerns, 1tlrough 6 on this report 19 Included on each sheet. and (3) each sheet Is numbered and m.mber of Sheets Is recorded at !he ~ of this form.

FOAM NI8-2 (Back)

9. Remarks Suwort& Designed to AI8C-1969 and wekfed 10 AWS 01.1-86.

Reference equlval6ncy determlnatloo C092533401 Ref: Transaction It 191681 vr-3 Conducted CERTIFICATE OF COMPLIANCE I certify that the statements made In the report are carect and that IhIs coolorms to the requlremenla of the ASME Code. Section Xl, Type Code Symbol Stamp:

NlA Certificate of Aulhorlzatlon No.:

N/A EJcpIratlon Date: ___......:.Nl:,:A":""__-4 Signed:

.L.~..

Asia O. Jerkins, Supt. Support Date:

1/4/',

O~1H's Deslgnse, TIIJe

--'l7~II-f.J'-----I CERTIRCATE OF INSERVICE INSPECTION I, the lI'ldersl!1led, hoIdlng a valid commission Issued by the National Boan:I 01 Boller and Pressure Vessel Inspectors and the SlateorProvilceof

~;f: and employed by_~~:z=;:;.."......:o--::::;t.._____________-I d

'~ cr have Inspected the COOlpooerns described In this Owner'sReportdurtngtheP~,

~)OtJ to

......L~/t,

.andstatelhatto the best d my knowledge and belief. the Ovmer ~e;;examinations and Iaksn ~1!iaIll1Im described in this OWner's Report In accon:Iance with the requirementS oItha ASME Code. Sectlon XI.

By slgnilg this certificate neither the Inspector na his ernpiooJer makes any wanmty. ~ a inplJed. concerning the ~

and coaectt-le meaBlIIQ8 desCriled In this Owner's Report. Furthermore, neilhet the Inspector nor his emplayer shall be liable In ffl';I manner fa any persooa/ InjUry a property damage or a loss 01 any kind ariStig from a coonected WIth this inspection.

Commlssloos: AJ:51!; ~

J 4nA-:6!:J,;H:";U Natlooa/Boarfi, State, ProvilCe, and EndorsemB/1ts

FORM NI$-2 OWNER'S REPORT FOR REPAlRlREPLACEMENT ACTIVITY As Required by Itte Provisions of the ASME COOe,Section XI

1. Oi.ner:

Sou1hem Nuclear Operatilg Co.

Date:

Octobef 22, 2010 Name 40 Inverness Center Parkway. Birmingham, AL 35242 Sheet:

of 2

Address

2. Plant:

Joseph M. Farley Nuclear Plant (FNP)

Unit:

FNPUnlt 1 Name 7388 North Stae Hwy 95; Columbia, AL 36319 Work Order No.:

E11-1092225901 Repa1fIRepiacement OrganlzatkX'l PO No, Job No, otc.

3. Work Pertamed By:

FNP Malntenance Depar1ment Twa Code Symbol Stamp:

N/A Name 7388 North State Hwy 95; Columbia, AL 36319 Authorization No.:

NlA Elcplratlon Date:

N/A

4. ldentiflcalfon of System:

TPNS: 01 E11SNUBBRHRaR67B RESIDUAL HEAT REMOVAL SYSTEM ASME CLASS 2

5. (a) Applicable Con&tItlCtia1 Code:

SEe Remarks

  • NlA Edillon.

NfA Addenda.

N/A COdeCas&

~ -------

(b) Applk:abIe Edition of Section Xl Used for RepalrlReplacement ActMty:

2001 Addenda:

Year (c) Applicable Section XI COde CUe(s):

NlA

6. (dentiflCatial of Compon8nlll:

Corrected, ASMEC0d6 Name of NatIonal Other Year Name of Component Manufacturer Serial No.

R6fIlOIIed. or Stamped Manufacturer Board No.

IdenIlIlcatIon Built Installed

{Yes or No)

Hydraulic Snubber ITT GRINNELL 14748 NlA FNP-222 1977 Removed NO' Hydraulic Snubber ANVIL 37740 NlA QP090698 2009 Installed NO

7. Descr1ltlOn of W0I1c Snubber AHA6-R67B was replaced lIS a scheduled upg!ade Ref: Transaction It 191672
8. Jests Conducted:

Hydrostalic.. Pneumatic II Nominal Opellillklg Pressure II Exempt III Pressure:

Test Temp.:

OF


psi NOTE: Supplemental sheets in form of lists. sk&tches, or drawings may be used, provided (1) size Is 8-112 In. x 11 In.*

(2) Informatlon In Items 1 through e on this report Is InCluded 011 eacI'I sheet. and (3) each sIlee11s nll11bered and number of sheets is recorded at !he ~ of this foon.

FORM NI5-2 (Back)

9. ReI'fI8I'ks Supports Designed to AISC.1969 and welded 10 AWS 01.1-86.

Refert!lOC9 equlvalencydetefmlnation C092533401 Ref: Transaction It 191672 VT*3 Calducled CERTIFICATE OF COMPLIANCE Icertify that 1he statements made In the report are correct and that this conforms to the requlremen1s of the ASME Code,Section XI.*

Type Code Symbol Stamp:

N/A CertiflcaIa of Authaization No.:

N/A ExpIration Date:

NlA SIgned:

.A/'],

Asia O. Jet1dns, Supt. Support Date: --/r-~.,-j'-J

/.-.

"1..;....;.,.;----1 j

~er's Designee, Title

.I CERTIFICATE OF INSERVICE INSPECTION I. the undersigned. holding a valid commlsslOO Issued by lila Natia1al Board of 6oi1er and Presst1'6 Vessellnspec10rs and the StatecrProvInceof ~

and employed by-'-'!ioI:C:;;......_C7=...-._.____________--1 of

~ cz:=

have Inspected the COOlPQ1<<lI8 descrl:led In this Owner's R~

~.ao;J to u/uJq

.and state that to the best 0/ my knO'Medge and belief, the C>Mler has I'f~ed examinations and taken ~tI}imeastxes descrlJed In this Owner's RepoI1ln accordance with the requirements of the AS ME Code, Sectfon XI.

By signing this certificate neither the Inspector nor his emplater makes anywarranty, eJqlI'essed Of bnpied, cmcemlng the examinations and correctfIIe measures descrlled In this Owner's Report. FurlhentlOl'e, neither !he Inspector nor his ElI'I1!)IOyQr shall be liable In any manner for any personaIlnjlJy cr p!oper\\y damage or a loss of any kind arising Iran or cameclBd't1.i1h this ~tion.

D~ __..-~~~~____..-__..-__..-__

FORM NIS-2 OWNER'S REPORT FOR REPAIRfREPLACEMENT ACTIVITY As Aequlred by the Provisloos of the ASME Code, SectIon XI

1. Owner.

Southern Nuclear Operating Co.

Date:

0ct00er 22, 2010 NBJ'(I(J 40 Inverness Cooter Parkway: Birminfl1am, AL 35242 Sheet:

of 2

At:k!Iass

2. Plant:

Joseph M. Farfey Nuclear Plant (FNP)

Unit; FNPUnit 1


~------N~am--e----~--~------

7388 North State HWV 95; Columbia. AL 36:319 WOI1tOrderNo.:

E11*1092226001 RepairlR8P/acement Otganizatbn PO No, Job No, etl:.

3. Wot1< Perlormed By:

FNP MahtErlanC9 Department Type Code Sl'm~ Stamp:

N/A Name 7388 NOI1tI State HWV 95; Columbia, Al36319 Authorlzation No.:

N/A N/A

4. Identification of System:

TPNS; Q1E11SNUBBAHAA105 RESIDUAL HEAT REMOVAL SYSTEM ASME CLASS 1

5. (a) Applicable ConstructIOn Code:

See Remarks

,NlA Edition, NlA

Addenda, NlA CodaGase y;

(b) Applicable Edition 01 S6c1lon XI Used lor RepairIReplacement Activity:

2001 Addenda:

2003

--~~~&V~--

(c) Applicable SectIon XI Coda Case{s):

N/A

6. IdantIfIcatIon of Components:

Com!cted, ASMECode Name of National Other Year Name 01 Component Manufacturer Serial No.

Ret'TICMld, 01 Stanped ManufactJJrer Board No.

Idenliflcallan Built Installed (Yes 01 No)

Hydroollc Snubber ITT GRINNELL 14592 NlA FNP-222 1977 Removed NO H~raullc Snubber ANVIL 37761 NlA QP090698 2009 Installed NO

7. Oasc~tlon of W~

Snubil<< RHR-R105 was replaced as a scheduled upgrade Rei: TnYlsactiOn' 191682 Pressure:

Test Temp.:

OF

--_--_psi NOTE: Supplemental sheets In form d lists, sketches, Of drawilgs may be used, prcMded (1) Size Is 8-112 in. x 11 in.,

(2)Infonnallon In Items 1through 6 on this report islnclud<<! on each sI'Ieet, and (3) each shoot IS nll1'lb8red and number of sheeIs IS rec:m:Ied at the top of this larm.

FORM NIS-2 (Back)

9. RemarlIs Supports Designed to AISC*19B9 and welded to AWS 01.1-8&

Reference equivalency detemiinatfon C092533401 Ref: Transaction' 191682 VT*3 Cooducled CERTIFICATE OF COMPlIANCE I certify that !he statements mOOe In the report are correct and that this coofonns 10 the requiremEnts of the ASME Code. Sectloo XI.

Type Code ~1xlI Stamp; N/A CertIfIcate of Authorization No.:

NJA Expiration Date:

NlA Signed:

~~

Asia O. Jer1dIlfl.Supl Support Date: --,/'-_41ir#-.;-.-----I OMlf18f or'rJ;;,ets Designee. TitI8 7

7 CeRTIFICATE OF INSeRVlCE INSFECTION I. the undelSlgned. holding a vaild commission IssUed by1Jle NatIonal Board 01 Boller and PlBSsure Vessel Inspectors and the State or Province of 4't!1!'gH-and employed by~~~==::-_..::cr=-____________-...I of

~

e:r' have inspec1ed the compooents desCrlbed In IIlls 0Wner'$ Report~ioC?

jyjO)fo 10 IAo..4

.and state that to lIle best of my knowledge and beIlef. the Owner h~ examinallons and taken &:r;;;;t:measUIBS descrl;,ed In IIlIs owner's Report In accoo:fance wiIh the requirements of the ASME Code. Secllon XI.,

By slgnk'lg this cllf1iflcate neither the Inspector nor his empJa,w makes any warranty. expressed or implied. concerning the examinations and correctlve measures described In this Qv.ner's Report. FU1'IheITnOre. nelll\\er the Inspector nor his employer shatl be I~e in any manner for any personal Injury or property damage or a loss of any kind arising from or connected with IIlIs inspection.

Commissions: N&#;~ f- " -0'l1J1:1J

spectOr; Signstu/lf NatJonsl Boald. State, ProviJce, and EtIdcmuIments

~e: __~J~~~~_____________

/

/

FORM NI8-2 OWNER'S REPORT FOR REPAlRIREPLACEMENT ACTIVITY As Required by \\he Provisions of the ASME COOe, Sectloo Xl

1. Owner:

Southem Nuclear 0peraIing Co.

Dale:

October 22, 2010 Name 40 Inverness Canter Parkway. 8inningham, AL 35242 Sheet:

of 2

Attitess

2. Piant:

Joseph M. Fartey Nuclear Plant (FNP)

Unit:

FNPUnlt 1


~----~N~a-m-e--------~------

7388 NorItl State Hwy 95; Co/I6llbia. AL 36319 WOO< Order No.:

E11-1092226101 RepalrlReplacement OrganIZation PO No, Jab No. etc.

3. Work Performed By:

FNP MaIntenance Department Type COde Symbol Stamp:

NlA Name 7388 NorItl State Hwy96; Columbia. AL 36319 AU1ttOrizaIIon No.:

NlA E)(j:lIratlon Date:

NlA

4. Identlfblt10n 01 System:

TPNS: 01E11SNUBBRHRR95 RESIDUAL HEAT REMOVAL SYSTEM ASME CLASS 1

5. (a} Applicable Construction Code; See Aemarlcs NlA Edllloo.

NlA Ac:kIenda, NlA Code Case

--y;a; (b) Applicable EdlIbI of Section XI Used to!' RepalTlReplacernent Activity:

2001 Addenda:

2003

--~Y.~~-r---

(e) Applicable Section XI Code Case(s):

N/A

6. ldentlflcatlon of Components:

Corrected.

ASMECcde Name of NatIooaI Other Year Name d Canponent Manufacturer Serial No.

REII'I1OV9d. or Stlnped Manufacturer Board No.

Identlflcatlon Bull Installed (Yes or No)

Hydraulic Snubber ITT GRINNELL 13952 N/A FNP'222 19n Removed NO Hydraulic Snubber ANVil an56 NlA OP090098 2009 Installed NO

7. DescJ1ilcn of WOOc Snubber RHR*R95 was replaced as a scheduled upgrade Rei: Transaction # 191680
8. Tesls Conducted:

______llSi TestTemp.: _____"F Pressure:

NOTE: Supplemental sheets In form of IIsIs. skeIches. or drawings may be used, prOYkled (1) size Is 8-1/2 In. x 11 In.,

(2) Inforrnaifon In ItemS 111'1r<ltq16 00 this report Is included Ql each sheet, and (3) eactI sheet Is numbered and m.mbar of sheel9ls recorded at the top d this form.

FORM NIS-2 (Back)

9. Remarks supports Designed to AISC*1969 and welded IoAWS 01.1-86, ReferEllce equivalency delermk1ation C092533401 Ref: Transaction # 191680 vr*3 Cmducted CERTIFICATE OF COMPLIANCE I cartify IhaIthe statements made In !he report are correct and 1hat this conforms to the requirements of the ASME Coda, Sectlon XI.

Type COOe Symbol Stamp:

NlA Crilcate of Au1horI2alIcJ1 No.:

N/A Elcplrallon Date:

Wit Signed:

AsIaO.Jerkins.Supt. Support Data: --,.

....cf?:2.d=

j,'.-.;.,hl,..;....----t allmer or OIIm6f's Designee, TLtIe I

CERTIFICATE OF INSERVICE INSPECTION I. the undersigned. hoIdilg a vaIld commlssb'llsSuad by1he NatIooal6oard of Baler and Pressure Vessel Jnspectom and the Sta\\eor Pmvilceof

~,#= and emplOyed by~;;::C::"-'...::;,(._~_______~___--I of

~ Cz:..

havelnspeqted the compooents descriled In this CNmer's Reputdumgthe pilfIod

.~

~b to -.L/;th

,andsta\\elhalto

!he best of my knowledge and belief. lha Owner tJa("~ 6lC8Illinatioos and taken ~Wl8sutes descrilecf In this Owner's Report In accordenCe with the requiremenlB of the ASME Code,Section XI.

By signing this certificate neither the Inspector nor his employer makes any warranty. spressed or mplled. concerning the mcamJnalion8 and corrective measures deScribed In this Ovmar's RepcIt Furthermore. neither the Inspector nor his employer shall be liable In arry manner for any personallnjlJ'y or property damage or a loss of ant Idnd arising from or coonacted with Ihi9 i'lspec!Ioo.

Date: #J

FORM NIS.2 OWNER'S REPORT FOR REPAlRlREPLACEMENT ACTIVITY As Required by the Provfskm ci the ASME Code, Sectlon XI

1. Owner.

Southern Nuclear OperaIlng Co.

Date:

October 23, 2010 Name 4() Inverness Center Parkway: Birmingham, AL 35242 Sheet:

0/

2 Address

2. Plant:

Joseph M. Farley Nuclear Plant (FNP)

Unit FNP Unit 1


~N~MM------------------

73S8 North Slate H~ 95; Columbia. AL 36319 Wad< Order No.:

P16* 1092226201 AddrlJSS RepallRepIacement OrganfZsi& PO No, JOb No, etc.

3. Wori< Performed By:

FNP Main1enance Department Type Code 5)m1Xll Stamp:

N/A Name 7388 North state H~ 95; Columbia. AL 36319 AulhoI'IzatIon No.:

NlA Expiration Date:

NlA

4. Identlflcafion ci System:

TPNS: Q1 P16SNUBBSW9R23 SERVICE WATER SYSTEM. ASME CLASS 3

5. (a) Applicable Coostructlon Code:

SeeRemarks

,N/A Edltlon, N/A

Addenda, N/A CodeCase YeaI (b) A~e EdItIon of Sectioo XI Used few Repair/Replacement AcIMty:

2001 Attlenda::

2003

--~YQU~--

(e) AppIicableSectkm XI Cade Case(s):

NlA

6. IdentificaUon 0/ Com~ents:

Corrocted.

ASMECode Named Na\\klna.I Other Year Name 0/ Component Manufacturer serial No.

Removed, or Stamped Manufacturer Board No.

Identification Buill Installed (Yes or No)

Hydraulic Snubber ITT GRINNELL 11n4 NJA FNP'222 1972 Removed NO Hydraulic Snubber ANVIL 37758 NJA OP090698 2009 Instaled NO

7. Dsscrlpllon of Waf<:

Snubber SW9-R23 was replaced as a scheduled upgrade Rei: Transaction. 191675

8. Tests Cooducted:

Exempt *.

Other

  • Pressure: --___ !lSI Test Temp.:

OF NOTE: SUpplemental sheel8ln form dllsts, sketches. or drawings maytleused. provfded (1) slzals 8*112 In. x 11m.*

(2) informatIOn In Items 1 throug/16 on this report is included on each sheet. and (3) each sheet is m.rllbered and I'IlII'Iber 0/ sheeIs Is recorded at tha klp d INs farn.

FORM NlS.2 (Back)

9. Rem.

Supports Designed to AISC-1969 and welded to AWS 01.1-86, Reference equivalency detem1fnatlon C092570501 Ref: Transaction # 191675 VT~3 Conducted CEATIFICATE OF COMPUANCE I certify that the statements made In the report are correct and that this conforms 10 the requ/nlm8n1s of Ihe ASME Code, Sectla1 )(1; T)'Ile Code Symbol Stamp:

NlA Certlftcate of AI.Itho!ization No,l NlA ExpIraIlon Date:

NlA Signed:

d

., ~...

Asia O. Ja1dns. Supt. Support Date: --,/-~"-';'-';/':':':'----I OImer~r'S Designee, Tille CERTIFICATE OF JNSERVICE INSPECTION I, the undersigned, hddIng a valid commission Issued by 1he NatIonal BoaJd of Boler and Pressure Vessel Inspectors and 1he State or Province of Gfl!::t!(i"'=

and emp\\o)'ed by.LJ.::.=~_cr;;';"______________-I of

~ c:r:

have ilspected Ihe components desclibed In this OY.fler'sRePOrt'dUl'klQ1 period

~..i:::?b to Jh;-.b/

'and state that 10

!he best of my kno¥.fedge and belief, Ihe Owner ~peIf&r;;ed examilations and taken c'"~res described illhls OWneI's Report In accadance with the requirements of Ihe ASME Code, Sectim XI.

By signing !hJs certlflca1e neither Ihe Inspector nor his employer makes any warnvrty. eJCpfeSSed or inpIed. COlCemilg Ihe exami1a1Ions and corrective measures described In this 0Wner'8 Report. Fur1hemIore, neIIhef Ihe Inspector nor his employer shall be liable In any manner for any personal InJury or property damage or a loss of any kind arising frOm or connected with this Inspection.

National Board, StaIB, ProviJce, and Endorsements

~~ ----~~~~-----------------

FORM NIS-2 OWNER'S REPORT FOR REPAIRIREPLACEMENT ACTIVITY As AGqt.tlred by lhe Provisions of the ASME Code,Section XI

1. Owner:

Southern Nuclear Operating Co.

Dale:

December 2,2010 Nams 40 Invernel3s Center Parkway; Birmingham. Al35242 Sheet:

ot 2

AddlfilSS.

2. Plant Joseph M; Farley Nuclear Planl (FNP)

Unit:'

FNP Unill


N~a~ms~----~--~-----

7388 North Stale Hwy 95; Columbia. AL 36319 Work Ordef No.: 1092714401 Addrsss RepairIReplacement Organization PO No. Job No. etc.

3.. Work Performed By:

FNP Maintenance Department.

Type COde Symbol Stamp:

NlA Name 7388 North State Hwy 95: Columbia. AL 36319 N/A Explratlo~ Date:

N/A

4. Identification of SystemI.

Q1P16V0584-2" CHECK VlV (code class 3)

5. (a) Applicable Construction Code;,

Section III

  • 1971 EcIItIon.

W' 1971 Addenda.

NlA Code Case


Y84f (b) AppDcable Edition of Section XI Used for Repair/Replacement Ac1IvIty:

2001 Addenda:.

2003 Year (e) Applicable SectIon Xl Code Case(s):

NlA

6. Identification of Componentst National Corrected, ASMECcda Name of Other Year Name of Component Manufacturer Serial No.

Board Removed. or Stamped Manufacturer ldenllflcatlon Built No.

Installed (Yes or No)

Z' Check Valve Kerotest DX3-3 NlA FNP295 1975 REMOVED YES 2" Pipe Daniel Construcllon HBC-2()()'E4191 NlA FNP295

. len AEMOVED YES 2" Check Valve Flowserve 53BEK N/A QP050547 2006 INSTALLED YES 2" Pipe Kerotest OOA054337 N/A QP080236 2006 INSTAlLED NO REPLACE 2~'CHECK VALVE AND PIPE 8_ TestsConductIKt Hydrostallc []

Pneumallc []

Nominal Operating Pressure Ii!

Exempt []

Other!:]

Pressure: ----psi Test Temp.;

~F NOTE:, Supplemental sheets In form of liSts. sketches, or drawings may be used, provided (1) size iI 8-112 In. x 11 In" (2) information in Hems 1 th~ 6 on this report Is Included on each sheet, and (3) each sheet Is numbered and numbel of sheets/s recorded at the top of this form.

FORM NIS.2 (Back)

9. Remarks Replacement Valve is ASME Soo. III. 1971 EdRlon. Wintef.1971 with para.. NB6111C of Winter 1972 code class 2 Replac8menl Pipe is ASME Sec. III. 1977 Eclition.wtthWlnter 1977 addenda code claSs 2 FNP Piping specification SSl109IJ1Hiliows a conslrualon rnide of 7ttlME*SiCtion III. 19J.lEditiOn lhi'iilRlOO Edinon Ad&iMli VT*2 completed Sat Transaction 1I's: 192902 CERTIFICATE OF COMPUANCE

, certlfy that the statementli made in the report are conect and thai this conforms to the requirements of the ASME Code,Section XI.

~~,~~------~

"'OWner or Owners Des(gnee. Tills Type Code Symbol Stamp:

N/A Certlflcale of AuthorizatIOn No.:

N/A ExPIration Date: ____N_'_A___-I Signed:

~.. '7 Asia O. Jerkins, Maintenance Spt. Support Date:

,"j" CERTIFICATE OF INSERVICE INSPECTION I, the undersigned. holding a valid commission Issued by the Nallonal Board of Boiler and PressUre Vessel Inspectors and the stale or Province of

~H;-

and empJoyedby-"_I101::-__= _________________ --t of have In~ the components described In this Ownel's Report during the period

'I to

.and slate that to

/ 4$'It the besl 01 my knowledge and belief. the r h performed examinations and taken ~1i\\I9 measures described in this Owner's Report in IlCCQroance with the requirements of the ASME Code,Section XI.

By sigling this certificate neither the Inspector nor his employer makes any warranty. elCpf8SS<<lor bnplled, concerning the examlnallons and oorrective measures described in this Owner's Repott. Furthermore. neither \\he Inspector nor his employer shall be liable In any manner for any personal Injury or property damage or a loss 01 any kind arising from or connected \\\\tttI this fnspection.

~/gna'Ure Date: ----;,.r.1A":"~.:jIC.m,='1J----

/

7

FORM NIS*2 OWNER'S REPORT FOR REPAIRIREPLACEMENT ACTIVITY As Required by the Provisionll of the ASME Code. Sectlon XI Southem Nuclear Operallng Co..

Date!

January 4.2011 Nama 40 Inverness Center Parkway; 8lrmingham. AL 35242 of 2

Addllilss

2. Plar¢ ____J_o_se...;,p_h_M_,,_F_Sr1_90i0:Y_NU_cl_Ela_rP_,_an_t.;..;(F_N_P_)___

Unit:

FNP Unit 1 Name 7300 North State Hwy 95; Columbia. AL 36319.

Work Order No.:, WO 1092811301 Addllilss

.' A8psJrlR;;pJ8C6mant Organization PO No; Job No; etc.

FNP Maintenance Department Type Code Symbol Stamp:

NlA Nam6 7300 North Slate Hwy 95;Columbla, AL 36319 Authorizalfon No.:

NJA Addmss ElpIrat/on Dale~

NJA

4. Idenllllcatlol1 of System:

TPNS:Q1PI6*HNC*201-53 SERVICE WATER PIPE (code class 3) 5, (a) Awilcable Construclion cooe:

Section III

  • 1971 Edillon;.. 1971 Summer Addenda.

N/A Code Case

~

. (b) AppIIcabfe Edition of Section XI Used for Repair/Replacement ActMty;:

2001 Addenda:

Year (0) Applicable Section XI Code Case(sk NJA 6; Iden\\lll<:atlOn of Component&!

Nallonal Corrected.

ASMECode Name of Olher Year Name 01 Component Manufacturer Serial No.

Board Removed,or Stamped MlIII\\Jlacturet' Idsn\\fflcatloo Built No.

Installed (Yes or No)

S' Rflange (2)

SCSIGrinnell JF-4-1010 MIA P16-HBC-201*S3 1973 REMOVED YES 8" SCh. 40 Pipe SCSIGrinnell JF*4*1010 N/A PI6*HBC*201-53 1973 REMOVED YES Slud, 3/4R_10X4.S' (qty8)

Unkoown Unknown N/A Unknown Unk.

REMOVED NO Stud. 3I4'*10X7.25' (qty8)

Unknown Unknown NJA Unkoown Unk*.

REMOVED NO Nut. 314'-10 (qty32)

Unknown Unknown N/A Unknown Unk.

REMOVED NO S' RHange (1)

Westem Forge HT~217E078 N/A QP060469 2005 INSTALLED NO 8' Rflange (1)

Westem Forge HT#247K490 MIA QP091129 2009 INSTALLED NO S' Sell. 4() Pipe USSleel HTIiXQ4284 NlA QPQO.0914 1995 INSTALLED NO Stud, 314'*1 OX4.5* (qty8)

NOVA Machine HTII7BOOlO4 N/A QP090378 2005 INSTALLED NO Stud. 3I4'*lOX7.2S' (qty8)

NOVA Machine HT# 243163 NJA QPOS0595 2008 INSTALLED NO Nut. 314'*10 (qly32)

Unytlte. Inc.

HTIIS44035 NIA QP090289 2001 INSTALLED NO

7. DescriptIOn of Worli:

REPLACEMENT OF SW FLANGE. AND PIPE

a. Tests Conducted:'

HydrostatIc []

Pneumatic []

Nominal Operating Pressure fa Exempt [J OtherCl Test Temp.:

Of


pst NOTE: Supplemental sheets in foon of lists,. sketches, or drawings may be used, provided (1) size fs Ml2ln.)( 11 in., (2) irriormalion in ilems 1 through 6 on this report Is included on each sheet, and (3) each sheet is numbered and number of sheets Is recorded at the top of this form.

FORM NI8-2 (Back)

9. Aemasks Replacement Flan'gSs are P2r ASME Sec. III, 1983 Edition thru Summer 1984 Addenda, class 3 Replacement Pipes are per ASME ~ III, 1977 Edition, class 2 Replacement Studs and Nuts are per ASME Sec. m. 1989 Edition. class 1 Replacement Studs are per ASME Sec. JII, 1995 Edition. class 2 VT*2 and VT-3 Comp*. SaI.

FNP Piping SpeclllcaUon SS1109-02 allows a construction code 01 ASME Section III, 1971 Edition Ihru 2000 EdlHon/Addenda lor Piping class Hac; Transaction It's are: 172758. 172820. 172788.

CERTIFICATE OF COMPLIANCE I certify that the statements made In the repon are correct and that this conforms to the requirements of tf1e ASME Code, Sootion Xl.

Type Code Symbol Stamp:

NlA Certillcate 01 Authorization No.:

NlA Expiration Dale:

N/A


~

Signed:

/.~ /

Asia O. Jerkins. Maintenance Spt. Support Date:

Uwner or OWnets D9signss. Title CERTIFICATE OF INSERVICE INSPECTION I. the undersigned, hoking a valid commission Issued by the NatlonaJ Board of Boiler and Pressure VesseilnspectolS and the State 01' Province of

~ttt-:

and employed by t!T" of

~

c:r:

have InSpected the components described In tI1l8 Owner's Repo;t(flJrifIgiperiod

~

to

~

. and state that to the best of my knowledge and belief. the Owne~ ormed examinations and takefIciVe measures described ill this Owner's Report In accordarlce with the requil8fTlenls of the ASME Code. sectlon XI.

By signing INs cel1lflcate neither the Inspector nor his employer makes any wam1l11y. ~ or Implied. concemlng the examinations and coneclive measures described in Ihls Ownet's Report Furthermore. neither the Inspector nOl',hls empievet' shall be liable in any manner for any personal Injury Of property damage or a loss of any kind arising from or connected with this inspection.

Int!peCtor's SIgnature Date: --~~-r.e.:..._--------

FORM NIS-2 OWNER'S REPORT FOR REPAIR/REPLACEMENT ACTIVITY As Required by the ProYislons of the ASME Code, SacHon XI L Ownen Southern Nuclear Operating.Co, Datet' November 22.2010 Name 40 Invemess Center Parkway; Birmingham, AL 35242 Sheet.'

of 2

Address

2. Plant' Joseph M. Farley Nuclear Plant (FNP)

Unit.

FNP Unit 1


N~~------------------

7388 North Stal& Hwy 95; Columbia, AL 36319 Work Order No.:

1100371801 Address RspairIRepJac9fJ16llt Organi2allon PO No, Job No, ste.

3. Work Perionned By:

FNP Maintenance Department Type Coda Symbol Stamp:

N/A Hams 7388 North Stale Hwy 95: Columbia. AL 36319 Authorization No.:.

NlA Address Expliatlon Date:

NlA

4. IdentificatiOn of System:

01 P16V005A

5. (a) Applicable Construction Coda:'*

Sec:tkln III Addenda.

NlA Code Case

'"Y6M (b) Applicable EditiOn 01 &Ictkln XI Used for Repalr/Replacement ActMty:

2001 Addenda:

2003

--~Y~mu~--

(c) Applicable Section XI Code Case(s):

NJA

6. IdentJllcation of Components:,

National Corrected.

ASMECode Name 01 Other Year Name of Component.

Manufacturer Serial No.

Board Removed. or Stamped Manutacturer IdentiflcaUon BuiJt No.

InstaRed (Yes or No) 2" Valve SNLlnd.

A060102*1*8 NlA QP06003 2006 REMOVED YES 2' Valve BNLlnd.

A010809-H3 NlA QP070175 2001 INSTALLED YES

7. Description of Work:

REPLACED VALVE (LESS END CAPS)

8. Tests Conducted:

Hydrostallc CI Pneumallc 0 Nomfnal Operating Pressure E2I Exempt 0 Other 0 Pressure: ----psi Test Temp,: -----

Of NOTE: Supplemental sheets In form of IISIS, Sketches, ordrawtngs may be used, provided (1) size 198-1121n. x 11 in., (2) Information In items 1 through 6 on this report Is.1nc1uded on each sheet, and (3) each sheet fs numbeJed arid number of sheets Is recorded at the lop of Ihls formi

FORM NI5-2 (Back)

9. Remalks

.Transaction 4t lor new valve: 1.90924.

ASME Sec. III. Winter 1971. NB6t11.1C of w' 72 class 3 CERTIFICATE OF CQMPLIANCE Icertify that the statements made In the repol1 are correct and that this conforms to the requIrements of the ASME Code, SecHon XI.

Type Code Symbol Stamp:

N/A Cel1IIIcate of Authorization No.:

N/A Expiration Date: _____Nl_A____-I Signed:

~~...

Asia O. Jerkins. Maintenance Spt. Support Date:

OiJ1fr6r or OWner's Designee. TIt/9


~

CERTIFICATE OF INSERVICE INSPECTION I. the undemigned, holdIng a valid commission IsS4.led by the National Board 01 Boiler and Pressure Vessel Inspectors and the State or Province 01

~f::= and employed by_~==__c::r_~'_-:-__:-:-____:-:--:---:-::----:-:--t ot~ gr have inspected the components descn1led In this Owner's Report during thlperiod Ozkh to

-'-hA>}//

.and state that to the best of my knowledge and belief, the Owne7has~onned examlnallons and tal<~messurB$ described in Itlis Owner's Report in accordance with the requirements of the ASME Code, SectIon XI.

By signing this certificate neither the Inspector nor his employer makes any warranty. expressed or implied, concerning the examinations and corrective measures described In this Owner's Repol1. Furthermore. neither the Inspector nor hIs employer shall be liable in any manner for any personal Injury or property damage or a loss of any kind arising from or connected with this Inspection.

Commissions; AiJ#'I:h:!>7rl' t1:i4-8'Vl If:I;:IJ NatJonaJ Board, State, PlTJflince. and EfIdonIsments Date: _---II.+b'-¥--+ha.'JI______

/

/

FORM NI8-2 OWNER'S REPORT FOR REPAIRJREPLACEMENT ACTIVITY As Required bV the Provisions of !he ASME Code. Sec110n XI Southern Nuclear Operating,Co.

Date; November22~ 2010 NBm8 40 Invemess Cenler Parkway; Blnningham. AL 35242 Shoot!

of 2

Addmss

2. Plant:

Joseph M. Farley Nuclear Plant (FNP)

Unit:

FNP Unit 1


~----~N~Bm8--------~~------

7388 North Stale Hwy 95; Columbia, AL 3631~

Work Order No.~ 1100371901 Repafr/RePiaC6ment Orgsntzatfon PO NO. Job NO. elO*.

3. Work Perfonned By:

FNP Malnlenance Department Type Coda Symbol Stamp:

NlA Name 7388 North Slate Hwy 95; Cclumbia, AL 36319 Authorization No.:

NlA Expiration Dale:

NtA

4. Idenllffce1lon of System; Q1 P16VOO5B* 1A CCW HX SW INLET TUBE SIDE DRN code class 3
5. (a) Appll~e Construction CPde:.

Section III

  • 1971 Edition; W' 1972 Addenda.

NlA Code Case


""Ye8r (b) ApplICable Edition of SectIon Xl Used (or Repair/Replacement AclMty:,

2001 2003 YBat (c) Applicable Section XI Code Case(s)~

NJA

6. Identification of ComponentS'~

NallonaJ Corrected, ASMECode Name of 0Iher Year Name of Component Manufacturer Serial No.

BoaId Removed, or Stamped Manufacturer ldenliflcallon Built No.

Installed (Yes or No) 2" Stainless Ball Valva BNLlnd.

A060905*1*3 NtA QP080782 2006 REMOVED YES 2' Stainless Ball Valve BNL lod.

A070009-1.21 NfA QP08003 2010 INSTALLED YES

7. Description of Work:.

REPLACED BALL VALVE

8. Tests Condlcted:

Hydrostatic C PneumaiIC C NomfhatOperating Pressure

&!I Exempt C

____psi Other C Pressure:

Test Temp.: ----

Of' NOTE: Supplemental sheetS In fonn of 1i1l1S. sketches, or draWings may be usec:t.. provided (1) size Is B-1J21n. x 11 In**. (2) Infonnatlon In Items 1 Ihrough 6 on this report Is Included on eactl sheet. and (3) each sheet is numbered and number of sheets Is recorded altha top of this form:

FORM NIS*2 (Back) 9, Rematks TransacUon nfor new valve: 19101B ASME Sao. III. Winter 1971, NB8111.1C of w' 72 class 3 CERTIFICATE OF COMPLIANCE I certify that the statements made In the report are correct and that this conforms to the requirements 01 the ASME Code,Section XI.

Type Code Symbol Stamp:

N/A Certificate of AUlhorizatlon No.:

NIA ExpJra1fon Date:

NlA

~"7 Asia O. Jerkins, Maintenance Spl. Support Date: ----------1 SIgned:

"eI!IIfsror Ownet's Designee, Title CERTIFICATE OF INSERVICE INSPECTION I. the undersigned, holding a valid commISSion Issued by the Natlonai Board 01 Boiler and Pressure Vessel Inspectors and the Stale or Province of

~t:= and employed by...&..&.=;;;..-__cr--'-______________--t of C.

have Inspected the COfflponeflts descnbed in this Owner's Report during I period to II)4./1/

. and slate that to the best of my knowledge and belief, the Owner as ormed examinations and tak~. measures described in this OWner's Report in accocdance with the requirements of the ASME Code,Section XI.

By signing this certificate neithef the Inspector nor his employer makas any warranty. expressed or implied. concerning the examinatIOns and corrective measures described In this Owner's Report. Furthermore. neither the Inspector nor his employer shall be lIatJ1e In any manner lor any personal injury or property damage or a loss of any kind arising from or connected with \\his inspection.

FORM NI8-2 OWNER'S REPORT FOR REPAIR/REPLACEMENT ACTIVITY As Required by the Provisions of the ASME Code.Section XI

1. Owner:

Southern Nuclear OperalHlg Co.

Date; January 4. 2011 Name 40 Inverness Center Parkway; Birmingham. AL 35242 Sheet:

01 2

Address

2. Plant:

Joseph M. Farley Nuclear Plan1 (FNP)

Unit:

FNP Unil1


~N~s-m-e------------------

7388 North State Hwy 95; Columbia. AL 36319 Work Order No.:

WO 1101054401 Address Repair/Replacement Organizarion PO No. Job No. ere.

3. Work Performed By:

FNP Maintenance Department Type Code Symbol Stamp:

NA Name 7388 North Stale Hwy 95: Columbia. Al36319 Authorization No.:

NtA Address Expiration Date:

NIA

4. Identification of System:

TPNS, 01P16POO1C 1C SERVICE WATER PUMP (COde ctass 3)

5. (a) Applicable Construcllon Code:

Sechonlll

  • 1971 Edition. 1971 Summer Addenda, Nla Code Case Year (b) Applicable Edition of Section XI Used for Repair/Replacement Activity:

2001 Addenda:

2003

--~~~e-8r----

(e) Appllcable Section XI Code Case(s):

N/A

6. Identification of Components:

National Corrected.

ASMECode Name 01 Other Year Name of Component Manufacturer Serial No.

Board Removed,or Stamped Manufacturer Identiflcalion Buill No.

Installed (Yes or No)

Pump Upper Column Hyundai NP*95*034 2241 OP95*0628 1995 REMOVED YES Pump Intermediate corumr Hyufldai Np*95*035 2242 QP95*0628 1995 REMOVED YES Pump Lower Column Hyundai NP*95*036 2243 OP95*0628 1995 REMOVED YES Pump Bowl Assembly Byran Jackson 197282 NIA FNp*220 1973 REMOVED YES Pump(Less Dishcarge HOI Byren Jackson 721*E*0220 N/A FNp*220 1973 INSTALLED YES Weld Metal (EA70S*2)

ESAB Hn065915 N/A OP090526 2009 INSTALLED NO Weld Melal (ER7OS*2)

ESAB HTit065706 NiA OPQ40823 2004 INSTALLED NO

7. DeScription 01 Work:

REPLACEMENT OF SW PUMP (Less Head I

8. Tests Conducted:

Hydrostatic [J Pneumatic 0 Nominal Operating Pressure eJ Exempt [J other [J Pressure: _____psi Test Temp.: _____ oF NOTE; Supplemental sheets in form of lists. sketches. or drawings may be used. provided (1) size Is 8*112 in. x 11 in** (2) information In items 1 through aon this report is Included on each sheet, and (3) each sheet is numbered and number of sheets is recorded at the top of this form.

01 FORM NIS-2 (Back)

9. Remarks APP/@16 M8ff1.1l.c/U;;;(iQ m/8 h~s 10 b...tl~C/Jd Olscharge Head Iro01 eXisting pump was 191.lS00 Vl*2 and VT-3 Compo Sat Transacllon # i~: 185142. MIR 539()2 CERTIFICATE OF COMPLIANCE I eartHy Ihat the stalemenls made in tile report ara correct and thallhis conforms 10 the requirements of the ASME Coda,Section XI.

Type Code Symbol Stamp:

Certificate of AUlhorizatfOn~

N:A Expiration Dale:

N:A Signed:

~. ~..

ASia O. Jel'lIns. Malnlenance Spf. SupPOTl Oala:

Iju/,t.

---+----+-------------~

...........'_v Owners Designe6, Tille CERTIFICATE OF INSERVICE INSPECTION I. the undersigned. holding a valkl commission issued by the National Board of Boller and Pressure Vessel Inspectors and the Stale or Province of and employed by


~------~------------~~~~

have inspected the components described in this Owner's Report duling the period to

  • and state that to the best of my knowledge and belief. the Owner has pelformed e~mlnQlioos and taken correctiVe measures described In this Owner's Report In accordance with the requirements of the ASME Coda,Section XI.

By signing thIS certificate neither the Inspector nor his employer makes any warranly. elq)tessed or implied, concerning lhe e~inalioos and corrective maasuras described In this Owner's Report. Furthermore, neither tile Inspector nor his employer shall be liable In any manner for any personal Irtjury or property damage or a loss of any kind alislng from or connected with this insp!lCtion.

Commissions:

-~N.:':'a-:/i':"*ona--:/-:8':"08-rd-:-.5=ra:-:"III-,P-=rovI-':"nce-.-a-nd-:-':E:':"ndQ"':'""rs-e-me-n-:"rs--I Inspi1Ctor's Signaturs Date:

FORM NIS-2 OWNER'S REPORT FOR REPAIR/REPLACEMENT ACTIVITY As Required by the Provisions of the ASME Code, Secllon XI

1. Owner.

Southern Nuclear Oporating Co.

Date:

December 2, 2010 Nama 40 Inverness Center Parkway; Birmingham. AL 35242 Sheet:

01 2

Address

2. Plant:

Joseph M. Farley Nuclear Plant (FNP)

Unit:

FNP Unit 1


~N~B-m-e------~----------

7388 North Siale Hwy 95; Columbia. AL 36319 Work Order No.:

WO 1101055201 Address Repair/Replacement Organization PO No, Job No. etc.

3. Work Performed By:

FNP Maintenance Department Type Code Symbol Stamp:

N/A Name 7388 North Slale Hwy 95: Columbia. AL 36319 Authorization No.:

NIA Address EJq:>iralion Date:

N/A

4. Identification 01 System:

TPNS. Q1P16VOO11C CTMT COOLER 1C SW SUPPLY RELIEF VALVE (code class 3)

5. (a) Applicable Construction Code:

SectIon III

  • 1971 Edition, thill Wtr 1971 Addenda.

1555 and 1574 Code Case


y;;;;

(b) Applicable Edition of Section XI Used for Repair/Replacement AcUvity:

2001 Addenda:

2003

--~Y,~e-a-r---

(c) Applicable Section XI Code Case(s):

NlA

6. Identillcation of Components:

Name of Component Name 0' Manufactorer Manufacturer Sarial No.

National Board No.

Othar Identification Year Built Corrected, Removed,or Installed ASMECode Stamped (Yes or No) 1-1'2' X2" Relief Valve Lonergan Co, 2010130-5*3 NIA FNP-Z9S 1974 REMOVED YES 1.2' Studs (4) unknown unknown NIA unknown unk REMOVED NO 1/2-Nuts (8) unknown unknown NiA unknown unl<

REMOVEO NO 1*1/2' )(2" Ralief Valve Anderson Crosby N99904*00-oo09 NIA QP090757 2010 INSTALLED YES li2' Sruds (4)

Nova 750919 H2374 NIA QP100627 2010 INSTALLED NO li2' Nuts (8)

Nova 361170 NiA QP1(IOOB2 2010 INSTALLED NO

7. Description of Work:

REPLACEMENT OF RELIEF VALVE. STUDS AND NUTS B. Tests Conducted:

Hydrostatic D Pneumalic Cl Nominal Operaling Pressure 6!l Exempt 0 Other 0 Pressure:

psi Test Temp.:

OF NOTE: Supplemental sheets in form of lists, sketches, ordrawlngs may be used, plovided (1) size is 8-112 in. x 11 in.* (2) information In items 11hrough 6 onlhis report is included on each sheet. and (3) each sheet is numbered and number of sheets Is recorded allhe top of Ihis form.

FORM NIS-2 (Back)

9. Remarks Replacement of Relief Valve is 01 ASME Sec. III, 1974 Edition lhru Summer 1975 Addenda. ClilSS 2 APp),CBble Manu/Bcluro? Data RopOl/S to b. atlilcflaa Rellel valve is reeoniled lhrough ED 1103283101 Replacemenl 01 Siuds are per ASME Seelion III, NC 19133 no addenda class 1 Replacement 01 Nuts are per ASME Seclion III, NC 1989 no addenda class 2 FNP Piping Specltication S5110902 allows a conslrucllon Code of A5ME Seclion 111.1971 Edillon lhru 2000 Edition Addenda The specification reqUire lhe matenat to be SA 194 Gr. 2H or SA 193 Gr B 7 lor studs alld nuts VT*2 completed Sal.

Transaction #'5: 195334, 198183 CERTIFICATE OF COMPLIANCE I certify that the slalements made In the report are correct and that this conforms to the requirements of the ASME Code,Section XI.

Type Code Symbol Stamp:

NIA Cerlillcate of Authorization No.:

NiA Expiration Date: _____N_i_A____-I

--Po"':}

}\\

Signed:

ASia O. Jerkins. Maintenance Spl, Suppon cM7feror OWner's Designee, Title CERTIFICATE OF INSERVlCE INSPECTION I, the undersigned, holding a valid commission Issued by the National Board of BoHer and Pressure Vessel Inspectors and the State or Province 01 and employed by

-"~~~~~----------------------------__i of have inspected the components described in this to

, and state that to o


~~~~-------

the best of my knowledge and belief, the Owner h s pe ormed examinations and taken c Owner's Report in accordance with the requirements of the ASME Coda,Section XI.

By slgning this certificate neither the Inspector nor his employer makes any warranty, expressed or Implied, concerning the examinations and corrective measures described In this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arisIng from or connected with this Inspection.

c./fnsp9CtOf'SSignature Date:

FORM NIS-2 OWNER'S REPORT FOR REPAIR/REPLACEMENT ACTIVITY As Required by the Provisions 01 the ASME Code,Section XI

1. Owner:

Southern Nuclear Operating Co.

Date:

December I, 2010 Name 40 Inverness Cenler Parkway; Birmingham, AL 35242 Sheet:

of 2

Address

2. Plant:

Joseph M. Farley Nuclear Plant (FNP)

Unit:

FNP Unit 1


~N~8m-e------------------

7388 North State Hwy 95; Columbia, AL 36319 Work Order No.:

WO 1101055202 Address Repair/Replacement Organization PO No, Job No, etc.

3. Work Performed By:

FNP Malntenal1ce Department Type Code Symbol Stamp:

N/A Name 738S North Slate Hwy 95; Columbia, AL 36319 Authorization No.:

N/A Address Expiration Dale:

N/A

4. Identification 01 System:

TPNS; Q1P16VOOllD CTMT COOLER 10 SW SUPPLYAELIEF VALVE code class 3

5. (a) Applicable Construction Code:

Section III

, 1971 Edition. thruWtr1971 Addenda.

1555and1574 CodeCase Year (b) Applicable Edition of Section XI Used for Repair/Replacement Activity:

2001 Addenda:

2003 Year (c) Applicable Sectlon XI Code Case(s):

N/A

6. Identilication of Components:

Name of Component Name of Manufacl1Jrer Manufacturer Serial No.

National Board No.

Other Identification Year Built Correctad, Removed, or Installed ASMECode Stamped (Yes or No) 1*112' X2' Relief Valve Lonergan Co.

2010130*5*4 N/A FNP*296 1974 REMOVED YES 112' Studs (4) unknown unknown N/A unknown unk REMOVED NO 1/2" Nuts (8) unknown unknown N/A unknown unk REMOVED NO 1*1/2' X2' Aellef Valve Anderson Crosby N99904*QQ*Q007 N/A QP090757 2010 INSTALLED YES 112' Studs (4)

Nova 750919 H2374 N/A QP 100627 2010 INSTALLED NO 1/2" Nuts (S)

Nova 361170 NIA QP1000S2 2010 INSTALLED NO

7. Description 01 Work:

REPLACEMENT OF RELIEF VALVE. STUDS AND NUTS

8. Tests Conducted:

Hydrostatic 0 Pneumatic 0 Nominal Operating Pressure

&!I Exempt 0 Other 0 Pressure: ____psi Test Temp.:

OF NOTE: Supplemental sheets in fonn 01 lists. sketches. or drawings may be used, provided (1) size is 8*1/2 in. x 11 In.* (2) information in Items 1 through 6 on this report is Included on each sheet, and (3) each sheel is numbered and number of sheets is recorded althe top 01 this fonn.