Letter Sequence RAI |
|---|
CAC:001029, (Approved, Closed) EPID:L-2023-LLA-0102, Transmittal Letter from Ahmad M. Al-Daouk (NNSA) to Ngarcia Santos (NRC) Related to the Application for Certificate of Compliance No. 9355, Revision 4, Model No. 435-B (Approved, Closed) |
Initiation
- Request, Request, Request, Request, Request, Request, Request, Request, Request, Request, Request, Request, Request, Request, Request, Request, Request, Request, Request
- Acceptance...
- Supplement
Results
Other: ML18206A311, ML18317A353, ML18317A355, ML22005A350, ML22006A352, ML22006A353, ML22006A356, ML22278A001, ML23003A046, ML23137A441, ML24204A233, ML24275A093, ML24289A207, ML24305A054
|
MONTHYEARML18156A4282018-05-30030 May 2018 Letter from J. Mccann/Columbiana Hi Tech to Document Control Desk Application for Revision of Certificate of Compliance No. 9291 for the Model No. Liqui-Rad (Lr) Transportation Unit Package, Docket No. 71-9291 Project stage: Request ML18206A3112018-07-25025 July 2018 Letter to Mccann Application for Amendment of Certificate of Compliance No. 9291 for the Model No. Liqui-Rad Transport Unit Package - Accepted for Review Project stage: Other ML18264A0022018-09-0707 September 2018 Columbiana Hi Tech, LLC - Certificate Holder Name and Address Change Project stage: Request ML18269A2732018-09-24024 September 2018 Package: Renewal of Certificate of Compliance No. 9291 for the Model No. Liqui-Rad Transport Unit Package Project stage: Request ML19015A3732019-01-10010 January 2019 Tn Americas, LLC - Application for Revision to Certificate of Compliance for USA/9291/B(U)F-96 for the Model No. Lr Transport Unit Project stage: Request ML18317A3522019-02-13013 February 2019 Package: Amendment and Renewal of Certificate of Compliance No. 9291 for the Model No. LIQUI-RAD (Lr) Transport Unit Package Project stage: Request ML18317A3532019-02-13013 February 2019 Enclosure 1: Certificate of Compliance No. 9291, Rev No. 11 (Letter to W. Edwards Amendment and Renewal of Certificate of Compliance No. 9291 for the Model No. LIQUI-RAD Transport Unit Package) Project stage: Other ML18317A3552019-02-13013 February 2019 Letter to W. Edwards Amendment and Renewal of Certificate of Compliance No. 9291 for the Model No. LIQUI-RAD Transport Unit Package (W/Enclosure 2) Project stage: Other ML20209A3722020-07-27027 July 2020 Notice of Partially Closed Third Pre-Application Meeting with Tn Ammericas LLC for Model No. TN-EAGLE Transportation Package Project stage: Meeting ML22005A3462021-12-14014 December 2021 Transmittal Letter from A. M. Al-Daouk to U.S. Nuclear Regulatory Commission, Renewal Request of the Certificate of Compliance No. 9329 for the Model No. S300 Package Project stage: Request ML22005A3502021-12-14014 December 2021 Email from D. Ortega (NNSA) to N. Garcia (U.S. NRC) Renewal of Certificate of Compliance (CoC) No. 9329 for the Model No. S300 Package Project stage: Other ML22006A3522021-12-27027 December 2021 Enclosure 3: Email Dated 12/27/21 from S. Burns (Nwp) to N. Garcia Santos (Nrc), Comments on Telephone Call Summary Dated 12/1/21, Model Nos. TRUPACT-II and Halfpact Packages Project stage: Other ML22006A3532021-12-27027 December 2021 Enclosure 2: Attachment to Email Dated 11-29-21, Responses to Follow Up Questions, Acceptance Tests for the Lead Ssield of the Shielded Canisters (Model Nos. TRUPACT-II and Halfpact Packages Project stage: Other ML22006A3562021-12-27027 December 2021 Enclosure 5: Clarification Regarding Testing Performed During the Shielded Container Prototype Testing (Drop Tests, Gamma Scans, Destructive Disassembly), Model Nos. TRUPACT-II and Halfpact Packages Project stage: Other ML22006A3552022-01-0606 January 2022 12/1/21-Conference Call Summary: Follow Up Questions Related to Shielding RAIs RAI-Sh-5 and -8 (Acceptance Tests, Shielded Canisters), Model Nos. TRUPACT-II and Halfpact Packages Project stage: RAI ML22020A1872022-01-25025 January 2022 Enclosure 2 - Safety Evaluation Report: Renewal for Certificate of Compliance, Revision 6, the Model No. S300 Package Project stage: Approval ML22278A0072022-09-0808 September 2022 Email from T.E. Sellmer (Nwp) to N. Garcia Santos (NRC) Acknowledgement of Application for CoC, Revision 27, Model No. TRUPACT-II and CoC, Revision 11, Model No. Halfpact Packages Project stage: Request ML22278A0012022-10-0404 October 2022 Email from T. Sellmer (Nwp) to N. Garcia Santos (NRC) Et Al., Delay of RAI Response-CoC, Revision 27, Model No. TRUPACT-II and CoC, Revision 11, Model No. Halfpact CoCs Project stage: Other ML23046A4542023-02-15015 February 2023 Request for Authorization of One-Time Shipment of Model No. Halfpact Crediting the Outer Confinement Vessel as the Containment Boundary Project stage: Request ML23089A2582023-03-29029 March 2023 Email Attachment, Staggered Request for Additional Information (Structural Evaluation and Operating Procedures), Model No. Halfpact - One-time Letter Authorization Project stage: RAI ML23003A0462023-03-29029 March 2023 Response to Request for Reviewing a Position Paper from Nuclear Fuel Services, Inc. Related to Applicability of 10 CFR 71.15(C) to Shipment(S) Project stage: Other ML23333A0332023-05-30030 May 2023 Email Dated 5-30-23 from T Holly (NFS) to Ngarcia Santos (Nrc), Transmittal of Affidavit Related to Fissile Material Exemption (10 CFR 71.15 (C), Follow Up Questions and Additional Comments (Docket No. 70-143) Project stage: Request ML23137A4412023-06-0202 June 2023 Authorization for Shipment of the Model No. Halfpact Package - Inner Containment Vessel No. 506 Project stage: Other ML23220A1552023-07-21021 July 2023 Email Dated 7-21-23 from J Mumma (NNSA) to Ngarcia Santos (NRC) Transmittal Letter and Changes Roadmap CoC No. 71-9355, Revision 4, Model No. 435-B Project stage: Other ML23220A1562023-07-21021 July 2023 Road Map for Changes to the Safety Analysis Report Related for Certificate of Compliance No. 9355, Revision 4, Model No 435-B Project stage: Other ML23220A1572023-07-21021 July 2023 Transmittal Letter from Ahmad M. Al-Daouk (NNSA) to Ngarcia Santos (NRC) Related to the Application for Certificate of Compliance No. 9355, Revision 4, Model No. 435-B Project stage: Request ML23263A1022023-09-20020 September 2023 Email Dated 9-20-23 from N. Garcia Santos (NRC) to J. Mumma (Nnsa), Subject: Package Model No. 453-B--Need Clarification on Submittals Project stage: Approval ML24072A0022024-03-0505 March 2024 Revision of Model No. 435-B Package’S Certificate of Compliance (CoC) Number 9355 for the 435-B Package Project stage: Request ML24150A4092024-06-14014 June 2024 Conversation Record -- Clarification Call with NNSA Regarding NRC Staffs Observations Pertaining to Amendment Request for Certificate of Compliance (CoC) No. 9355 for the 435-B Package, Submitted Via Letters Dated July 3, 2023 and March 5, Project stage: Approval ML24295A1602024-06-30030 June 2024 Redacted, Industrial Nuclear Company - Application for Certificate of Compliance for the Inc IR1 00ST, Revision 0, Docket No. 71-9385 Project stage: Request ML24204A2332024-08-0808 August 2024 Acceptance Determination Letter with Observation, Certificate of Compliance No. 9355, Model No. 435-B Project stage: Other ML24248A2532024-09-20020 September 2024 Request for Additional Information, Certificate of Compliance No. 9355, Revision 4, Model No. 435-B Packaging, EPID L-2023-LLA-0102, CAC 001029 Project stage: RAI ML24281A1762024-09-25025 September 2024 9/25/2024 Conference Call Summary - Supplemental Information to Proposed RAI Responses Related to the Criticality Safety Review of the Model No. Castor geo69 Transport and Storage Systems (Docket Nos. 71-9383 and 72-1052, Respectively) Project stage: Supplement ML24312A2212024-10-0101 October 2024 Extension Request - Robatel Technologies’ Response to U.S. NRC Request for Additional Information for Review of the Robatel Technologies, LLC Model No. RT-200 Type B(U) Cask - Cac/Epid Numbers: 001029/L-2024-NEW-0003 Project stage: Request ML24275A0932024-10-11011 October 2024 Transmittal Letter - Certificate of Compliance No. 9310, Revision No. 8, for the Model No. F-431 Transport Package Project stage: Other ML24289A2072024-10-28028 October 2024 Transmittal Letter and Enclosure, Requests for Supplemental Information and Observations for Revision 0 of CoC No. 9385 for the Model No. IR 100ST Project stage: Other ML24305A0542024-10-31031 October 2024 Email Dated 10-31-24 from Ngarcia Santos (NRC) to Mrose (Inc), Final Signed Letter with Requests for Supplemental Information for the Model No. IR 100ST Project stage: Other ML25086A0382024-12-0606 December 2024 Letter Dated 12/6/24 from Kschwendenman (NNSA) to Ngarcia Santos (Nrc), Response to Request for Additional Information on Preshipment Leakage Rate Test (Model No. 435-B, Docket No. 71-9355) Project stage: Request ML25086A0322024-12-0606 December 2024, 9 January 2025, 4 February 2025, 21 February 2025 Responses to Requests for Additional Information for CoC No. 9355, Revision 4, Model No. 435-B (Docket No. 71-9355) Project stage: Request ML25142A1582025-05-21021 May 2025 Email Dated 5/21/2025 from Mrose (Inc) to Ngarcia Santos (Nrc), Request to Stop Work Related to Certificate of Compliance No. 9385, Revision 0, Model No. IR100ST (Docket No. 71-9385) Project stage: Request PMNS20250901, Meeting with Tn Americas LLC2025-07-11011 July 2025 Meeting with Tn Americas LLC Project stage: Request ML25178C6732025-08-0101 August 2025 Enclosure 1 - Request for Supplemental Information for HI-STAR 330 Transportation Cask, CoC No. 9397 (Redacted Public Version) Project stage: Request ML25213A1502025-08-0707 August 2025 Memo and Enclosures 1 and 3 Re Summary of July 23, 2025, Pre-Application Meeting with Tn Americas Project stage: Meeting ML25253A4892025-09-11011 September 2025 Additional Observation for HI-STAR 330 for CoC No. 9397, Model Number HI-STAR 330 Project stage: Request 2023-07-21
[Table View] |
Text
UNITED STATES NUCLEAR REGULATORY COMMISSION WASHINGTON, D.C. 20555-0001 Ahmad M. Al-Daouk, Director Office of Packaging and Transportation U.S. Department of Energy National Nuclear Security Administration P.O. Box 5400 Albuquerque, NM 87185
SUBJECT:
REQUEST FOR ADDITIONAL INFORMATION FOR REVIEW OF THE CERTIFICATE OF COMPLIANCE NO. 9355, REVISION 4, FOR THE MODEL NO. 435-B PACKAGING - COST ACTIVITY CODE/ENTERPRISE PROJECT IDENTIFICATION NUMBER 001029/L-2023-LLA-0102
Dear Ahmad Al-Daouk:
By letter dated March 5, 2024 [Agencywide Documents Access and Management System (ADAMS) Package Accession No. ML24072A001], the U.S. Department of Energy, National Nuclear Security Administration (NNSA or the applicant), requested a revision to the Certificate of Compliance (CoC) for the Model No. 435-B packaging. In summary, the March 5th letter states that the applicant is requesting approval of the changes depicted in the July 2023 submittal (ML23220A071).
In connection with our review, we need the information identified in the enclosure to this letter.
To assist us in scheduling the NRC staffs review of your response, we request that you provide this information 60 calendar days from the date of this letter. Inform us at your earliest convenience, but no later than 30 calendar days from the date of this letter, if you are not able to provide the information by that time frame. If you are unable to provide a response by then, our review may be delayed.
Please reference Docket No. 71-9355 and CAC/EPID Nos. 001029/L-2023-LLA-0102 in future correspondence related to this request. The NRC staff is available to clarify these questions, and, if necessary, to meet and discuss your proposed responses.
In accordance with Title 10 of the Code of Federal Regulations, Part 2 Agency Rules of Practice and Procedure, a copy of this communication will be available electronically available for public inspection in the NRC Public Document Room (PDR) or from the Publicly Available Records component of the NRCs ADAMS. ADAMS is accessible from the NRC website at http://www.nrc.gov/reading-rm/adams.html. The PDR is open by appointment. To make an appointment to visit the PDR, please send an email to PDR.Resource@nrc.gov or call 1-800-397-4209 or 301-415-4737, between 8 a.m. and 4 p.m. eastern time (ET), Monday through Friday, except Federal holidays.
September 20, 2024
A. Al-Daouk If you have any questions regarding this matter, you can contact me at Norma.GarciaSantos@nrc.gov.
Sincerely, Norma Garcia Santos, Project Manager Stotage and Transportation Licensing Branch Division of Fuel Management Office of Nuclear Material Safety and Safeguards Docket No. 71-9355 Certificate No. 9355
Enclosure:
Request for Additional Information cc:
71bn9355all@listmgr.nrc.gov Signed by Garcia Santos, Norma on 09/20/24
Enclosure Request for Additional Information U.S. Department of Energy National Nuclear Security Administration Docket No. 71-9355 Certificate of Compliance No. 9355 Revision 4 Model No. 435-B By letter dated March 5, 2024 [Agencywide Documents Access and Management System (ADAMS) Package Accession No. ML24072A001], the U.S. Department of Energy, National Nuclear Security Administration (NNSA or the applicant), requested a revision to the Certificate of Compliance (CoC) for the Model No. 435-B packaging.
This request for additional information (RAI) identifies information needed by the U.S. Nuclear Regulatory Commission staff (the staff) in connection with its review of the application.
NUREG-2216, Standard Review Plan for Transportation Packages for Spent Fuel and Radioactive Material," was used by the staff in its review of the application.
This RAI describes information needed by the staff for it to complete its review of the application and to determine whether the applicant has demonstrated compliance with the regulatory requirements of 10 CFR Part 71.
OPERATING PROCEDURES AND CONTAINMENT EVALUATION RAI-7-1 Clarify Section 7.1.3.1 step 10 of the application, related to:
1.
the shipment of Type B contents that has been preceded in shipment by Special Form, Type A contents, Low Specific Activity (LSA) material, or Surface Contaminated Objects (SCO) contents, specifically when the vent port plug cannot be verified as being closed for the Type B contents, and 2.
the performance of an ANSI N14.5 pre-shipment leakage rate test on seals that have been opened.
Section 7.1.3.1, step 10 of the application states the following:
10.
Pre-shipment leakage rate testing of the main containment O-ring seal and vent port sealing washer shall be performed according to the following criteria:
a.
If all of the radioactive material in the 435-B package is contained in sealed sources that have been qualified as special form according to the requirements of Section 7.1.6, Recognition of Special Form, no leakage rate test is required. NOTE: If this criterion is not met, a leakage rate test must be performed according to (b) or (c) of this step.
2 b.
If the main containment (upper) O-ring seal has been replaced or the corresponding sealing surface repaired, or if the vent port plug or sealing washer has been replaced or the mating sealing surface repaired, the leakage rate tests shall be performed according to Section 8.2.2, Maintenance/Periodic Leakage Rate Tests.
c.
If the criteria of step (b) above do not apply, as an option, pre-shipment leakage rate testing may be performed according to Section 7.4, Pre-shipment Leakage Rate Test.
For part 1 of the clarification, package users should consider the following (with underlining for emphasis) from NRC Information Notice (IN) 2016-04, ANSI N14.5-2014 Revision and Leakage Rate Testing Considerations (ML16063A287), which would also apply to special form material as well as Type A contents, LSA material, or SCO. The staff acknowledges that the circumstances described below could be unlikely.
Pre-shipment leakage rate test on Type B package containment boundary components that have been opened: Section 7.6 and Table 1 of ANSI N14.5-2014 address the pre-shipment leakage rate test on Type B package containment boundary components that have been opened. The pre-shipment leakage rate test is necessary to confirm that the containment system is properly assembled for each shipment. Type B packages containing a Type B quantity of material could have been used to transport Type A, LSA material, or SCO in a previous shipment. Containment boundary components (e.g., seals and valves) could have been opened during a previous shipment of Type A contents, LSA material, or SCO, but a pre-shipment leakage rate test might not have been performed at that time. A pre-shipment leakage rate test should be performed on the containment boundary components that cannot be verified as being closed to confirm that the containment system is properly assembled on packages containing a Type B quantity of material.
For part 2 of the clarification, ANSI N14.5 pre-shipment leakage rate testing should be performed on containment boundary seals that have been opened, unless a maintenance/periodic leakage rate test has been performed before each shipment, after the contents are loaded, and the containment system is assembled, in lieu of a pre-shipment leakage rate test. This is especially important for Type B contents in normal form.
This information is needed to determine compliance with 10 CFR 71.37(b),
71.51(a)(1) and (2), and 71.87(c).